Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹6.6 L+₹38,360 (6.14%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT ADMITTED |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
3 Jul 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Budha Ram,IDSE
AGE I AF CHIMNEY HILLS,CHIKKABANAVARA,BANGALORE
REPAIR AND MAINTENANCE TO HT 11 KV SUPPLY NETWORK AT 58 AF STN CHIMNEY HILLS
2023_MES_602288_1
8632/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE I AF CHIMNEY HILLS BANGALORE
As per tender document
8 documents required · 8 mandatory
₹500
Yes
AGE I AF CHIMNEY HILLS BANGALOR
₹12,000
Yes
21 Nov 2023
9 Jun 2023
4 Jul 2023
9 Jun 2023
3 Jul 2023
19 Jun 2023
10 Jun 2023 - 14 Jun 2023
Amount
Supply, Laying and Testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 3 Core, 95 Sqmm.
Supply, Laying and Testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 3 Core, 185 Sqmm.
Supply, jointing and testing out door type HT cable end termination joint "straight through" heat shrinkable suitable for aluminum conductor XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, and over all PVC sheathed cable 11000 volts grade 3 core 95 sqmm nominal size all as directed.
Supply, jointing and testing out door type HT cable end termination joint "straight through" heat shrinkable suitable for aluminum conductor XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, and over all PVC sheathed cable 11000 volts grade 3 core 185 sqmm nominal size all as directed.
Taking out the transformer oil sample from distribution/isolation transformers, indoor/outdoor type and testing the oil for dielectric strength/moisture content complete all as specified and directed by the Engr-in-Charge.
Dehydration and Filtering the transformer oil having the dielectric strength below 40KV and testing of transformer oil after filtration as per IS-335-1972 and removing the moisture contents in the transformer cores/winding as directed by Engr-in-Charge.
Supply and filling top up new transformer oil in the transformer up to the marked level all as specified and directed by Engr-in-Charge.
Material and labour for lightning arresters for outdoor use expulsion type suitable for 11000 volts (HT) complete with all fittings, transmission class, discharge capacity 65 KA including taking down existing lightening arresters of any type and size complete all as specified and as directed.
Material and labour for fixing barrel fuse including fuse element suitable for HT 11 KV drop out fuse carrier up to 15 Amp rating all as directed after dismantling the exisiting out lived fuse barrel complete all as specified and as directed.
Material and labour for replacement of silica gel breather assembly for HT distribution transformers of 100 KVA to 200 KVA capacity including dismantling old one all as specified and as directed
Material and labour for replacement of silica gel breather assembly for HT distribution transformers of 400 KVA to 750 KVA capacity including dismantling old one all as specified and as directed
Cross arms,bracing bracet supports and back plate from structural steel sections including clamps,nut bolts washers welding,bending cold or hot drilling for bolts in any shape or size as indicated or directed and inclusive of one primer coat and two coat of aluminium paint all as specified and directed.
Supply and fix Electric rubber hand gloves in pair ,suitable for 11 KV ,ISI Mark all as directed by engineer in charge .
Supply and fix Fibre glass discharged rod ,Suitable for 11 KV all as per directed by engineer in charge and specified.
Repair / service / overhauling of gang operating devices 11000 volts upto 400 Amps including greasing all the moving parts and applying white petroleum jelly at the contact points, tightening all nuts and bolts and providing PG clamps, additional nut and bolts, commissioning and testing complete including dismantling and replacing all the unserviceable parts / spares all as specified and as directed. Note: Supply only of all the spares replaced shall be measured and paid separately.
Supply and fix moving contact blades suitable for 11 KV all as per directed by Engineer in charge .
Supply and fix contact jaw copper suitable for 11 KV all as specified and directed by engineer in charge .
Supply and fix Post insulator suitable for 11 KV all as per specified and directed by engineer in charge.
Locate and pin point faults in 11 kV Cable by fault locating instrument all as specified and directed by engineer in charge including following instruments:- (i) Impulse generator 0-33 KV. (ii) Acoustic fault locator to pin point the fault exactly at fault point (iii) Reflectometer (Laptop based) TDR set =input wave capturing (iv) High voltage Murray loop for % distance to constant leakage faults.
Material and labour for pin type, porcelain vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for 11000 volts grade all as specified and as directed.
Material and labour for disc type, porcelain vitreous, 145 mm height and 255 mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts grade complete all as specified and as directed.
Dismantling insulators of any type and size complete all as specified and as directed.
Material & Labour for GOD / Switches air break ,Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps including dismantling old all as per directed by engineer in charge.
Disconnection & Removing the unserviceable Aluminium conductor/jumper wires from the HT 4 Pole structure and M & L for New Aluminium overhead conductor jumpers sorrounded by PVC insulation sleeves with R,Y& B color code complete all as directed. Note : (1) All the jumper wires should be replaced with New jumper wires (2) Type of conductor used for jumper should be RABBIT. (3) Cost deemed to be include for all the misc work such as Nut,bolts, washers, welding etc. for satisfactory completion of job . (4) Min clearance should be maintained among the conductors as per the Electricity Regulations. (5) Zero percent Sag should be maintained for each jumper wire to avoid short ckts.
All as per item No.25 above but for 2 Pole structures.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as per directed and specified engineer in charge.
Supply and fix Danger notice plate of 1.6mm thick mild steel sheet with vitreouse name lled with letter figures and conventional skull and bones insignal red colour and fixed with MS clamps, bolts and nuts of approved size for HT, 25 x 20 cm all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in hard/dense soil for laying of cables all as specified and directed by engineer in charge.
Returning, filling in including spreading leveling, watering and well ramming in layers n. exc 25cms in hard/dense soil.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and spread dry vegetable Riddled soil in trenches for cable Cushioning.Note: for purpose of payment punned thickness only will be measured and paid.
Supply and lay burnt bricks, class 'B' designation 75 of size 230 mm x 115 mm x 70 mm for cable protection all as specified and directed by engineer in charge.
Supply and lay HDPE pipe ,Class PN10, 150 mm dia in trenches for road crossing/laid in floors etc.
Earth continuity conductor or main earthing lead fixed to pole on batten or recess or chases or buried inground or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. as required 25 X4 mm galvanised iron all as specified and directed.
M/L in repair providing earthing complete with galvanised steel earth plate electrode 6o CM x 60 CM X 6 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of back filling compound(BFC) & common salt Crystal and connected to galvanised earth strip 25 x4 mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 5 of SSR Part I of 1991 & testing complete including 40mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. ( Note1 :- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items ). Note 2: Qoted rate deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc.
Supply & fix Self powererd Relay ADR241S for VCB i.e. Overcurrent,Earth fault,under current,Thermal overload,Inrush blocking,Negative sequence,Broken conductor,auto reclose all as specified and directed .Make-Aashidha or equivalent
M & L for dismantling of existing poles from site with all accessories shifting the same from Main receiving station to MES store yard by using crane with safety measures complete all as specified and directed.
Supply and filling stone aggregates 40mm size for outdoor substation and around transformer / RMU upto 100 mm thick complete all as directed.
M&L Transformer Rubberized rubber Gasket suitable for 200 KVA Indoor ,oil coled Transformer all as specified and directed by engineer in charge .
Dismantling and removing the u/s earthing from the 4 Pole/3Pole/2 Pole structure all as specified and as directed
devan enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .