Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹15.8 LAdmitted-Finance | -2.51% | ₹15.8 L | L1 | Admitted-Finance |
Tender Value
₹16.2 L
EMD Value
₹32,340
Closing Date
2 Apr 2026, 3:00 pmClosed
Executive Engineer (E)
21st floor Vikas Minar.
Sh-Providing and replacement of Mechanical Ventilation system in Basement Floor.
2026_DDA_902755_1
45/EE/ELD-8/DDA/2025-26
Open Tender
Electrical Works
Percentage
180 days
Vikas Minar
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹32,340
6 May 2026
16 Mar 2026
3 Apr 2026
16 Mar 2026
2 Apr 2026
16 Mar 2026
Dismantling of existing GSS duct and associated accessories in the basement as per site requirement and as directed by the Engineer-in-Charge
Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Reconditioning, repairing, dismantling and re-installation, testing & commissioning of ceiling suspended double skinned 5 HP Fresh Air/Exhaust Air Unit with casing made of 0.63 mm thick GI powder coated/pre-coated outer sheet and 0.63 mm thick GI inner sheet, insulated with 25 mm thick fireproof glass wool (density not less than 32 kg/m³). The unit consists of centrifugal forward curved DIDW blower with TEFC weatherproof motor (Class-F insulation, EFF-2) with direct/belt drive arrangement including pulley, belt guard and common base plate. The work includes cleaning/servicing of blower, motor, shaft and fan section, repair/replacement of worn-out parts. The scope also includes removing, servicing and reinstalling of 900 mm dia fans, including cleaning, tightening of wire connections, checking/replacement of damaged parts, and testing & commissioning, complete as required.
Reconditioning and repair/replacement of worn-out and defective parts of 5 HP Fresh Air Unit/Exhaust Air Unit starter, including repair/replacement of defective components, checking and replacement of worn-out wires and interconnections, including the cost of connection through bus bar/copper conductor flexible connection with all accessories so as to make the fans fully functional. The job also includes testing and commissioning of the same, complete in all respects.
Credit: Buyback of dismantled GSS Duct and associated accessories etc. complete as required.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.21 MB
TenderDoc45.pdf
Tender Documents • 2.49 MB
BOQ_948861.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .