| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.8 CrAccepted-AOC | ₹1.8 Cr | 1 | Accepted-AOC WORK AWARDED |
| 2 | 2₹1.9 Cr+₹5.6 L (3.07%)Rejected-AOC SAKTHI MAHAL 63 PERUNDURAI ROAD ERODE 638011 | ERODE | ERODE | TAMIL NADU | 638011 | ₹1.9 Cr+₹5.6 L (3.07%) | 2 | Rejected-AOC Second Lowest |
| 3 | 3₹1.9 Cr+₹6.2 L (3.40%)Rejected-AOC | ₹1.9 Cr+₹6.2 L (3.40%) | 3 | Rejected-AOC Third Lowest |
| Sl No | Description | Qty | Unit | SELVAMADHU DEVELOPERS PRIVATE LIMITED L1 | Vaakai Infra Private Limited L3 | R.R.THULASI BUILDERS (INDIA) PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | WALL PANELLING SYSTEMS –PPGL PANEL.
The inner surface wall panel should be fixed to the bricks wall with essential supports. There should be minimum possible cavity/gap in between the brick wall and Supplying and fixing of PPGL modular clean room 50mm thick wall panel both side PPGL filled with PUF. The distance between the inside and the outside surfaces of the operating room will be variable to suit the architect’s layout, but shall be sufficient for the flush mounting of equipment’s. Following BS1142 part 3 (British Standard). The panel to panel joint done it by inter connecting profiles / tongue and groove. The cavity between the inner and outer walls will be left with minimum obstruction for the possible addition of equipment’s, enabling services, pipes, conduits etc., to be run within the cavity. | 658 | Sq.m | 10,611 ₹69,82,038 Lowest | 11,000 ₹72,38,000 | 10,800 ₹71,06,400 |
| 2.00 | CEILING SYSTEM : PPGL PANEL.
The ceiling should be made up of PPGL modular clean room 50mm thick ceiling panel both side PPGL filled with PUF. The ceiling system should consist of support elements, suspension bracket with tension spring and material should be high quality galvanized or powder coated steel. Modular clean room 50mm thick ceiling panel filled with PUF both side PPGL. Aluminium profiles for reinforcement along the periphery With aluminium grid with supporting system like, tie rod, turnbuckle etc.,Room lighting, air supply inlet, ceiling service units; return air outlets, etc. should be integrated with PPGL modular clean room 50mm thick ceiling panel both side PPGL filled with PUF. The vendor shall be responsible to integrate then air conditioning duct of the ceiling system with the existing outlet of AHU and the individual panels except those at the edges should be removable individually. The all four corners should have return air duct outlets and grill and the same should be made for powder coated steel with the color choice to suit the hospitals choice. The ceiling material should be certified according to the EN (European standards). | 366.5 | Sq.m | 10,900 ₹39,94,850 | 10,800 ₹39,58,200 Lowest | 11,000 ₹40,31,500 |
| 3.00 | Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre ‘T’. The ‘T’ shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of ‘T’ section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of ‘T’ section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile ‘L’ Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look. | 92 | Sq.m | 3,200 ₹2,94,400 Lowest | 3,300 ₹3,03,600 | 3,500 ₹3,22,000 |
| 4.00 | SS SURGICAL SCRUB STATION:
Supplying and fixing of Wall mounted 3 Stationed Surgical Scrub of size 1800 x 500 x 450mm, made up of SS 304 grade 1.2mm thick stainless steel sheet with necessary CP waste coupling and drain pipe for Surgeons & O.T Staff to scrub their hands and arms before a surgical / invasive procedure, including transportaion charges and etc.,complete complying with standard specification. | 6 | Nos | 58,100 ₹3,48,600 Lowest | 65,000 ₹3,90,000 | 66,000 ₹3,96,000 |
| 5.00 | Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. | 280 | Cu.m | 110 ₹30,800 Lowest | 148 ₹41,440 | 150 ₹42,000 |
| 6.00 | Supplying and filling in foundation, basement, etc with filling Crushed Stone Sand (M-sand) and in layers of not more than 15cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 15 | Cu.m | 1,500 ₹22,500 Lowest | 1,750 ₹26,250 | 1,600 ₹24,000 |
| 7.00 | Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification. | 15 | Cu.m | 5,100 ₹76,500 Lowest | 5,300 ₹79,500 | 5,500 ₹82,500 |
| 8.00 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) | 19 | Sq.m | 900 ₹17,100 Lowest | 975 ₹18,525 | 950 ₹18,050 |
| 9.00Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) | ||||||
| 9.01 | For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. | 72 | Sq.m | 1,000 ₹72,000 Lowest | 1,000 ₹72,000 Lowest | 1,050 ₹75,600 |
Tender Value
₹1.8 Cr
EMD Value
₹1 L
Closing Date
30 May 2025, 3:00 pmClosed
The Superintending Engineer, PWD.,
The Superintending Engineer, PWD., Buildings Construction and Maintenance Circle,Tiruvannamalai-4.
Providing Modular Operation Theatre with Laminar Air flow for the Construction of District Head Quarters Hospital at Tindivanam in Villupuram District.
2025_PWD_560991_1
4/TVM-CLE/25-26/1/ Dt.05.05.2025
Open Tender
Civil Works
Lump-sum
Tindivanam
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1 L
Yes
2 Sept 2025
23 May 2025
30 May 2025
23 May 2025
30 May 2025
23 May 2025
Amount
WALL PANELLING SYSTEMS –PPGL PANEL. The inner surface wall panel should be fixed to the bricks wall with essential supports. There should be minimum possible cavity/gap in between the brick wall and Supplying and fixing of PPGL modular clean room 50mm thick wall panel both side PPGL filled with PUF. The distance between the inside and the outside surfaces of the operating room will be variable to suit the architect’s layout, but shall be sufficient for the flush mounting of equipment’s. Following BS1142 part 3 (British Standard). The panel to panel joint done it by inter connecting profiles / tongue and groove. The cavity between the inner and outer walls will be left with minimum obstruction for the possible addition of equipment’s, enabling services, pipes, conduits etc., to be run within the cavity.
CEILING SYSTEM : PPGL PANEL. The ceiling should be made up of PPGL modular clean room 50mm thick ceiling panel both side PPGL filled with PUF. The ceiling system should consist of support elements, suspension bracket with tension spring and material should be high quality galvanized or powder coated steel. Modular clean room 50mm thick ceiling panel filled with PUF both side PPGL. Aluminium profiles for reinforcement along the periphery With aluminium grid with supporting system like, tie rod, turnbuckle etc.,Room lighting, air supply inlet, ceiling service units; return air outlets, etc. should be integrated with PPGL modular clean room 50mm thick ceiling panel both side PPGL filled with PUF. The vendor shall be responsible to integrate then air conditioning duct of the ceiling system with the existing outlet of AHU and the individual panels except those at the edges should be removable individually. The all four corners should have return air duct outlets and grill and the same should be made for powder coated steel with the color choice to suit the hospitals choice. The ceiling material should be certified according to the EN (European standards).
Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre ‘T’. The ‘T’ shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of ‘T’ section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of ‘T’ section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile ‘L’ Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look.
SS SURGICAL SCRUB STATION: Supplying and fixing of Wall mounted 3 Stationed Surgical Scrub of size 1800 x 500 x 450mm, made up of SS 304 grade 1.2mm thick stainless steel sheet with necessary CP waste coupling and drain pipe for Surgeons & O.T Staff to scrub their hands and arms before a surgical / invasive procedure, including transportaion charges and etc.,complete complying with standard specification.
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling Crushed Stone Sand (M-sand) and in layers of not more than 15cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement
For Superstructure in Ground floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire)
Brick work in Cement Mortar 1:6 (One cement and Six M-sand) using best quality of Second Class Ground Moulded Chamber Burnt Bricks of size 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.
For Foundation and Basement
For Superstructure in Ground floor
Plastering with Cement Mortar 1:5 (One cement and Five P-sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:3 (One Cement and Three P-Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two M-sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) (For 40mm Thick)
Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
Supplying, fabricating and fixing in position factory made Stainless Steel Flush Door Shutter 35mm thick using SS 304 Grade 1.6 mm thick, Stainless Sheets on both sides (Equivalent to IS 6911-04 Cr. 19, Ni 9) minimum 8-8.5% nickel and 18% chromium sourced from original stainless steel manufacturer with view panel size 30mm x 45mm made up of 6mm thick clear toughened glass fitted with double side adhesive tape and finished with dowconing silicon sealant, floor spring for each shutter, consealed tower bolt, suitable stainless steel locking arrangement and other necessary furniture fittings of approved quality. The vertical styles and other frame members and cross stiffeners shall be of same quality stainless steel box section of suitable size and thickness with proper core material as prescribed by the Departmental Officers.
Supplying and fixing of rolling shutters shall be Gear operated type made of 18/Gx3" lath sections with gear box system with handle which consist of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below:Curtain shall be of 18/Gx3" lath sections cut to required size and filled with heavy cast iron / MS clips. For 8' 0" (2.45m) high rolling shutter lath sections provided shall be not less than 37 numbers. Lock plate shall be of 10 GMS sheet reinforced with 40mm x 6mm MS angles at the bottom and fitted with heavy latches and locking arrangements on either sides. There should be one handle on either sides. Guide channel pressed guide channels shall be 10GMS sheet and attached to the side brackets with 20mm square bar. Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high carbon soil spring 2 springs shall be supplied. Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high carbon coil springs - 2 springs shall be supplied. Hood cover shall be of 0.8mm CRCA sheet reinforced with 25mm x 25mm x 3 mm MS angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated on exposed area with heavy coat of red oxide primer. (Gear Operated Type)
Painting two coats of newly plastered wall surface with ready mixed Plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying and fixing by drilling holes and not by puching for Roofing with pre painted Galvalum sheet of 0.47mm thick of best approved quality with required size with curved shape and white ridge sheet with necessary bolts and nuts bitumen washers, including cutting the sheet to the required size found necessary during execution etc., Complete complying with standard specifications. [The sheet should be got approved by the Engineer incharge before use on works]
Supplying and fixing 5 HP / 3 Phase, 9 Stage sub mergible pump of approved make and quality with ISI mark with necessary accssories and fixed with delivery pipe erected in the borewell with necessary clamp etc., with following additional accssories. 1 No of 3 Phase Star Delta Starter of 63 AMPS of approved quality and make with ISI mark. 1 No of 3 Phase 63 AMPS Main Switch of approved quality and make with ISI mark. 1 No of priventor of approved quality and make with ISI mark. 1 No of pannel board of required size with indicator fuse unit voltmeter with necessary provision to accomodate the starter and mini starter etc. 1 No of capacitor with board as per standards of TNEB.
Supplying, laying and jointing 300mm dia RCC Hume Pipe of approved quality with spigot and socket ends and fixing them in dry condition using spun yarn and cement including petty masonry shoring and strutting wherever found necessary and laying the pipe line in the alignment at the specified gradient and testing with necessary tools and plants, etc., and re-filling the trench with excavated earth and levelling the ground etc., complete complying with standard specifications. (Earth work excavation, re-filling with excavated earth will be measured and paid separately).
R.R.THULASI BUILDERS (INDIA) PRIVATE LIMITED (BID ID -1350477)
Vaakai Infra Private Limited (BID ID -1355536)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .