Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC being lowest bidder | |
| 2 | L2₹27.9 L+₹2.5 L (9.77%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L2 | Rejected-Finance not become lowest bidder | |
| 3 | L3₹28.5 L+₹3.1 L (12.4%)Rejected-Finance S 170 B 192 VILLAGE JHARERA DELHI SOUTH WEST DELHI DELHI 110010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance not become lowest bidder | |
| 4 | L4₹29.3 L+₹4.0 L (15.6%)Rejected-Finance | L4 | Rejected-Finance not become lowest bidder | |
| 5 | L5₹30.3 L+₹4.9 L (19.4%)Rejected-Finance | L5 | Rejected-Finance not become lowest bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 May 2025, 6:00 pmClosed
Major Sunny Kumar Attri
Garrison Engineer Jhansi
REPAIR, MAINTENANCE RENEWALS TO VARIOUS SIZES OF GI PIPE LINES, GATE VALVES AND CONNECTED WORKS IN ZONE C AND D AT JHANSI CANTT UNDER AGE E/M AT GE JHANSI
2025_MES_705430_1
GE/JHA/TOK/35 OF 2025-26
Open Tender
Pipe Laying Works
Item Rate
180 days
GE Jhansi
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Jhansi
₹70,000
Yes
7 Jul 2025
25 Apr 2025
16 May 2025
25 Apr 2025
14 May 2025
8 May 2025
25 Apr 2025 - 7 May 2025
Amount
Excavation in trenches not exceeding 1.5M width and not exceeding 1.5M depth and getting out for laying of pipe etc in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Removing excavated surplus in hard/dense soil to a distance not exceeding 50M and depositing where directed and at a level not exceeding 1.5M above the starting point complete all as specified and directed by Engr-in-Charge.
Material & Labour for PCC 1: 3: 6 type C1, using 20mm graded crushed trap stone aggregate & grouting in cement mortar 1:4 for making good road cutting complete all as specified and directed by Engr-in-Charge.
Taking up or down old unserviceable GI pipe lines alongwith fittings from existing connections of size 100 mm nominal bore complete all as specified and directed.
All as per item No. 05 above but of size 80mm nominal bore
All as per item No. 05 above but of size 50mm nominal bore
All as per item No. 05 above but of size 40 mm nominal bore
All as per item No. 05 above but of size 25 mm nominal bore
All as per item No. 05 above but of size 20 mm nominal bore
All as per item No. 05 above but of size 15 mm nominal bore
Supply & Laying in trenches galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site of size 100 mm nominal bore complete all as specified and directed. Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe.
All as per item No. 12 above but of size 80 mm nominal bore
All as per item No. 12 above but of size 50 mm nominal bore
All as per item No. 12 above but of size 40 mm nominal bore
All as per item No. 12 above but of size 25 mm nominal bore
Supply & Fixing galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors all as directed of size 25 mm nominal bore complete. Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe.
All as per item No. 17 above but of size 20 mm nominal bore
All as per item No. 17 above but of size 15 mm nominal bore
S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location of Size 50 mm nominal bore complete all as specified and directed by Engr-in-Charge.
All as per item No. 20 above but of size 40 mm nominal bore
All as per item No. 20 above but of size 25 mm nominal bore
All as per item No. 20 above but of size 20 mm nominal bore
Supply and fix cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts including dismantling of old unserviceable sluice valve fixed at any location of size 300 mm nominal bore all as directed.
All as per item No. 24 above but of size 250 mm nominal bore
All as per item No. 24 above but of size 200 mm nominal bore
All as per item No. 24 above but of size 150 mm nominal bore
All as per item No. 24 above but of size 100 mm nominal bore
All as per item No. 24 above but of size 80 mm nominal bore
All as per item No. 24 above but of size 400 mm nominal bore
M&L for Construction of valve chambers of size 1.0 x1.0 x 1.0 internal dimentions with 150 mm thick PCC foundation 1:4:8 type D2 using 40 mm graded trap stone aggregate, 230 mm thick brick masonary wall with sub class 'B' bricks builts in cement mortar 1:4 10 mm thick plastering to brick masonary in cement mortar internally and externally upto 15 cm below ground level, 50 mm thick coping with PCC 1:2:4 type B1 using 20 mm graded crushed trap stone aggregate valve chamber having coller frame size 1.0 x 1.0 x 1.0 made of mild steel angles of size 50mm x 50mm x 6mm and cover made of 2.5 mm thick mild steel sheet framed by 40 x 40 x 5 mm MS angle having 02 nos cross 'X' supprt fixed with coller frame by mild steel hinges - 02 Nos, locking arrangements with provision of locks and painting the steel surfaces with two coats of alluminium enameled paint over a coat of zinc chromate primer including neccessary earth work, excavation, all as specified and directed by Engineer-in-Charge .
All as per item No. 31 above but of size 1.2 M x 1.2 M X 1.2 M (Internal Size)
Providing JCB Loader to manage the breakdown and otherwise Excavation, shifting of pipes,and balancing work at any time in round the clock as per the direction of Engineer in Charge. Note:- Minimum hiring time not less than 3 Hrs
M & L for rectification of joint leakage of CI/DI pipeline incl excavation, return filling, leadwool, lead pig, tyton Joint, 'D' Joint, MS Clamp and short piece of CI/DI pipes as required at site etc of size 300 to 400 mm nominal bore pipe all as required and directed at site. Note:- Contractor will have to make arrangement for T&P, drain out/ pump out water. cutting of road/ path/culvert shall be make good as per original existing without any extra cost.
All as per item No. 34 above but of size 200 to 250 mm nominal bore pipe.
All as per item No. 34 above but of size 100 to 150 mm nominal bore pipe.
All as per item No. 34 above but of size 80 mm nominal bore pipe.
Repair to leakage of existing GI pipe line 15 mm to 20 mm bore in any positions (joints, fittings etc) on wall ,roof, floor etc including replacement of GI fittings such as tee ,sockets elbows,unions nipples,reducers etc incl necessary excavation and earth work complete all as directed by Engineer in Charge. Note:- (i) GI Pipe off size and Earth work for replcement of GI Pipe shall be measured and Paid separately under relevant items of this schedule.
All as per item No 38 above but GI Pipe of dia 25 mm to 50 mm nominal bore
All as per item No 38 above but GI Pipe of dia 80 mm to 100 mm nominal bore
M & L for Taking out Sluice valve of size 250 to 300 mm nominal bore for Refacing, Regrinding, Opening all parts at site and replacement of UNSV parts like MS Spindle, U clamp check Nut, Brass Gate, gasket seel, glands, nut, bolts, washer etc and refixing complete after repair at site as directed by Engineer in Charge.
All as per item No. 41 above but Sluice valve of size 150 to 200 mm nominal bore
All as per item No. 41 above but Sluice valve of size 80 to100 mm nominal bore
S&F of CI Detachable joint with nut bolts complete suitable for CI/DI pipe line of 50mm bore size with and incl all jointing material complete all as specified and directed. Note:- The rate quoted by contractor deemed to be incl necessary earth works.
All as per item No. 44.00 here-in-before but of size 80 mm nominal bore
All as per item No. 44.00 here-in-before but of size 100 mm nominal bore
S&F of DI Mechanical joint (MJ) collar with rubber ring complete suitable for CI/DI pipe line of 80mm bore size with and incl all jointing material complete all as specified and directed. Note:- The rate quoted by contractor deemed to be incl necessary earth works.
All as per item No. 47.00 here-in-before but of size 100 mm nominal bore
S & F in repalcement of Bib tap standard of PTMT any colour high pressure screwed for iron pipe suitable for 15mm dia complete all as specified and directed.
All as per item No. 49.00 here-in-before but of size 20 mm dia
S & F in repalcement of Stop cock standard of PTMT any colour high pressure screwed for iron pipe suitable for 15mm dia complete all as specified and directed.
All as per item No. 51.00 here-in-before but of size 20 mm dia
M&L for ductile iron fittings suitable for CI/DI pipe of size 80mm to 400mm nominal bore and any type, class K-12, such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces (single branch, "Y" junction, double branch, cross etc), caps and plugs etc, complete all as specified and directed.
ROHIT ENTERPRISES (BID ID -3293995)
Ayush Enterprises (BID ID -3294702)
AGRASEN ENTERPRISES (BID ID -3297064)
Dhruv Enterprises (BID ID -3296539)
M/S ARVIND SINGH THEKEDAR (BID ID -3295941)
S.R ENGINEER WORKS (BID ID -3297107)
ADARSH ENTERPRISES (BID ID -3296976)
M/S Kumar Contractors (BID ID -3297027)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .