Loading…
Loading…
Tender Value
₹14.8 Cr
EMD Value
₹29.6 L
Closing Date
22 Jul 2026, 3:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
S AND T
15 conditions · 3 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
For tenders having an advertised tender value exceeding 10 crore, the tenderer shall be required to satisfy the Bid Capacity criteria. The tenderer shall be qualified only if the Available Bid Capacity is equal to or greater than the value of the present tender. The tenderers shall submit requisite information as per Annexure-VI of GCC-2022 and up to date Correction slip of GCC 2022 to evaluate and decide bid capacity and financial eligibility.
10 conditions · 3 needing a document upload
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V and Annexure-V(A) of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
For tenders having an advertised tender value exceeding 10 crore, the tenderer shall be required to satisfy the Bid Capacity criteria. The tenderer shall be qualified only if the Available Bid Capacity is equal to or greater than the value of the present tender.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home page of IREPS portal for works tenders before submitting the e-tender. 1.General Instruction for E-Tenders on works contract--Chapter- I 2.Special Condition-General- Chapter-II
Opening of e-tender : 1. The e-tenders will be opened online using the IREPS portal anytime after tender closing time. No representative is required to be present for opening of e-tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders through the website after the opening of the tender. 2. The earnest money cost is to be paid through online banking facilities through the online portal and by giving the other details online on website www.ireps.gov.in. Note: For more details refer to Cl: 4 & 12 of General Instruction-Chapter-I for Submission of EMD, Cost of Tender Document and opening of e- tender.
Asansol Division: S&T Work i/c/w (1) Interlocking of LC Gates having TVU more than 10,000 in Andal -Sainthia, Deoghar - Dumka, Mohanpur Jn. - Handsiha sections of Asansol Division. (2) Interlocking of L. C. Gate having TVU more than 10000 in UDL- BBI, UDL/LC-BQT, MDP-GRD Sections.
28-SDSTE-ASN-2026-27
28-SDSTE-ASN-2026-27
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹29.6 L
22 Jul 2026
29 Jun 2026
8 Jul 2026
680 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 6,23,23,800.7 | ||
| — | 8.00 | — | — | ||
| Supply of Electrically operated Lifting Barrier complete set suitable for 110V AC / 24V DC / 110V DC. Supply of hand generator back up & motorized boom locking arrangements as per RDSO Spec. No. SPN/208/2012 Ver. 2.0 Amd.1 or with the latest amendment. One set consisting 02 No. of barriers of length 9.76 Mtrs. with stop boards, MS counterweights and 2 nos. of boom support, control panel, Spares & tool kit mentioned in RDSO Specification clause 10.1 & 10.2 mentioned below to be supplied with EOLB set : 10.1 Spares: (i) GI boom - 1 No. (ii) Belt - 1 No. (iii) Crank Handle - 1 No. (iv) Motor Contactor - 1 No. (v) Motor Protection MCB - 1 No. (vi) Push button complete - 2 Nos. (vii) Limit Switch - 3 Nos. (viii) Fuses used- 2 Sets. 10.2: Tool Kit as per RDSO specs. Warranty: Electric Lifting barrier shall be commissioned only if the installation is certified fit by the OEM. Electric Lifting Barrier complete including its sub-systems shall be under warranty for a period of 24 months date of commissioning, whichever is earlier. Inspection: RDSO. Payment: 80% on supply and balance 20% after commissioning. | — | — | — | 45,32,584 | |
| — | 8.00 | — | — | ||
| Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation (including supply of sand, stone, cement, bolt, plate, shuttering etc.) for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing / POLICY of ER, wiring etc. | — | — | — | 4,99,680 | |
| — | 16.00 | — | — | ||
| Supply of Dual Tone Bell/Buzzer with Flasher arrangement and 20 Watt horn working on 24 V DC/ 110 V AC for warning road users at LC gates. Inspection: Consignee | — | — | — | 96,656 | |
| — | 8.00 | — | — | ||
| Supply of electrical lifting barrier booms of 9.76 meter each as per DRG RDSO/S 11600. The material will be as per RDSO Spec. No. RDSO/SPN/208/2012 Ver.2.0 and Amendment.1 or latest. To be procured from RDSO approved sources. Inspection: RDSO. | — | — | — | 1,63,120 | |
| — | 8.00 | — | — | ||
| Supply of Motorised boom locking set (consisting of locking arrangement for two booms). The material will be as per RDSO Spec. No. RDSO/SPN/208/2012 Ver.2.0 and Amendment.1 or latest. To be procured from RDSO approved sources. Inspection: RDSO | — | — | — | 3,06,912 | |
| — | 8.00 | — | — | ||
| Supply of PMDC Motor 24V DC, 90W/1500 RPM. The material will be as per RDSO Spec. No. RDSO/SPN/208/2012 Ver.2.0 and Amendment.1 or latest. Warranty Certificate of OEM to be submitted. To be procured from RDSO approved sources. Inspection: RDSO | — | — | — | 1,18,448 | |
| — | 8.00 | — | — | ||
| Supply of boom lock PMDC motor 24V DC/40W/1500 RPM. The material will be as per RDSO Spec. No. RDSO/SPN/208/2012 Ver.2.0 and Amendment.1 or latest. Warranty Certificate of OEM to be submitted. To be procured from RDSO approved sources. Inspection: RDSO | — | — | — | 21,976 | |
| — | 8.00 | — | — | ||
| Supply of Friction Clutch Sub Assembly. The material will be as per RDSO Spec. No. RDSO/SPN/208/2012 Ver.2.0 and Amendment.1 or latest. To be procured from RDSO approved sources. Inspection:RDSO | — | — | — | 54,800 | |
| — | 8.00 | — | — | ||
| Supply of Control cum Indication panel Domino Type as per approved PFD at Mid- section interlocked LC Gate as per RDSO Specification No. RDSO/SPN/186/2004Rev. 2.0 or latest. Size of each Domino will be 54 x 34 mm2. Control Panel includes panel rest, front and side table, complete with switches, push button, termination of cables, painting and lettering as required. This also includes 10% spare of panel LED's, Dominos and button assemblies, counter, keys, buzzer etc. Inspection: RDSO | — | — | — | 4,84,912 | |
| — | 8.00 | — | — | ||
| Installation, fixing, complete wiring, testing , commissioning of the Control cum Indication panel domino type at Mid-section interlocked LC Gate as per approved interlocking plan, FPD, circuit diagram etc. This includes termination/ soldering of cables/wires, lettering. | — | — | — | 48,496 | |
| — | 8.00 | — | — | ||
| Supply of sliding boom gate as per eastern railway signal workshop/Howrah's drawing no. SW/SA/768 or Latest. This includes a supply of 6 nos. E-type lock with key as per IRS Spec. No. IRS:S-30/64 with latest amendment. Key lock 'e' type as per drawing no. SA-3376/M, SA- 3377/M with latest amendment or Latest. Ward no. To be decided by the site engineer. 'E' type lock to be on MS plate as mentioned in the drawing. Inspection:RITES Payment: 80% on supply and balance on commissioning. | — | — | — | 19,92,576 | |
| — | 8.00 | — | — | ||
| Casting, concreting & curing of foundation (1:3:6) for sliding boom gate as per drawing no. SGW-SDAH/SLIDING GATE FOUNDATION/2012 or Latest including supply & fixing of holding down bolts with washers and nuts, MS plates of size 350 mm. x 350 mm. x 8 mm., cement, sand, stone chips etc. For foundations required in each set of gate. | — | — | — | 5,36,248 | |
| — | 8.00 | — | — | ||
| Installation & commissioning of sliding boom gate. This includes levelling, fixing of sliding boom with fixing of E-type lock, etc. Note: all materials to be supplied by the contractor except sliding boom gate and E-type lock | — | — | — | 70,976 | |
| — | 8.00 | — | — | ||
| Supply of paint of approved quality (Asian, Berger, Nicholson) and painting of complete sliding boom arrangements and accessories (Rectangular boom movement stand, pillar supports, resting stand with one coat of red oxide and two coats of Yellow/black enamel paint & Yellow color retro reflective tape (HIP) with width of 12" and as directed by engineer in-charge at site. | — | — | — | 63,256 | |
| — | 2.00 | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines & TAN. It includes: Design and modification in existing Interface, Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel), CCIP (Control cum Indication Panel) if any, Maintenance terminal (MTPC), Data Logger, Relay rack wiring etc. The complete work should comply with the latest RDSO specifications, guidelines and as per approved SIP & circuit diagrams. All the material (Interface cards/ relays/ wiring material/ connectors/ fuses /communication devices etc.) shall be provided by the contractor. The work includes the supply of modified Selection table, Interface Circuits, VDU/LCP, CCIP diagram if any etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT or two rounds FAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on Auto CAD. Soft copy including Auto CAD copy has to be supplied in pen drive and 06 sets of hard copies also to be supplied as a completion drawing. | — | — | — | 36,56,562 | |
| — | 8.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Microprocessor based Networkable Analogue Addressable up to 64 nodes 1 Loop Fire Alarm Control panel with LCD display, the panel should be equipped with sufficient numbers of loop as per RDSO Specification No. RDSO/SPN/217/2025 Version No. 3.1 or latest. Each loop shall have capacity of 127 analogue addressable devices in 1 loop, the panel shall have sufficient No. of programmable relay control for controlling AHU's, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler & sealed lead acid batteries sufficient for 24 Hours normal working & then capable of operating the system for 24 Hours during Emergency conditions as required. The panel shall have provision of connectivity of BACNET/ MODBUS/ LONWOK/TCP-IP. The panel shall have dedicated RS232 serial port for direct PC or MODEM connection, optional remote printer as per RDSO Specification No. RDSO/SPN/217/2018 Ver.2.0 or latest. Inspection: RDSO. Payment: 70% on supply, balance on commissioning. | — | — | — | 5,61,272 | |
| — | 45.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of intelligent Analogue Addressable Multi-Sensor type smoke detector with inbuilt fault isolator and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air current. Detector should have a unique address for communication and be assigned through a panel with mounting base as required with the protection category of IP 40. All items as per RDSO Specification No. RDSO/SPN/217/2025 Version No.3.1 or latest. Inspection: RDSO. Payment: 70% on supply, balance on commissioning. Note- To be used in Ceiling at Relay Room, IPS room, OFC room. | — | — | — | 1,51,380 | |
| — | 8.00 | — | — | ||
| Supply, Installation, testing and commissioning of single channel laser or High-power LED based Aspiration detection unit with area covering 5000 sq. ft. with programmable 4 stage alarm generation and with 4 addressable modules. It should have an auto cleaning facility in the optical chamber, electronic discrimination of particle size, ultrasonic air flow sensing auto learn feature with TCP/IP network capability, the aspiration system shall also include external power supply unit with battery backup. Approval-UL/LPCB/VDS listed and shall comply with Specification No. RDSO/SPN/217/2025 Ver.-3 or latest. Spares cost is also included & to be supplied as per RDSO para no. 4.15. Inspection: RDSO. Payment: 70% on supply, balance on commissioning | — | — | — | 14,87,016 | |
| — | 500.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of UL/LPCB/VDS listed CPVC Pipe with suitable diameter as per requirements & pipe accessories for the Aspiration detection shall comply with RDSO/SPN/217/2025 Ver.3 or latest. Spares cost is also included & to be supplied as per RDSO para no. 4.15. Inspection: RDSO. | — | — | — | 1,89,500 | |
| — | 8.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Analogue Addressable Manual Call Point with integral short circuit isolator, Analogue addressable protocol having status LED for alarming & standby mode, Electronically addressed) as per RDSO Specification No. RDSO/SPN/217/2025 Version No.3.1 or latest. Inspection: RDSO. Payment: 70% on supply, balance on commissioning. Note- To be provided at a location diligently chosen. | — | — | — | 31,960 | |
| — | 8.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of intelligent Addressable Loop Powered Sounder cum beacon with base inbuilt fault isolator with protection category of IP42 and duly approved as per RDSO Specification No. RDSO/SPN/217/2025 Version No.3.1 or latest. Inspection: RDSO. Payment: 70% on supply, balance on commissioning. | — | — | — | 71,704 | |
| — | 600.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of FRLS unarmoured/armoured cable (2C x 1.5 sq. mm.) with all accessories for connection of all Fire Alarm devices as per RDSO Specification No. RDSO/SPN/217/2025 Version No. 3.1or latest. Inspection: RDSO. Payment for Supply Items: 70% on supply and balance on commissioning. | — | — | — | 75,000 | |
| — | 8.00 | — | — | ||
| Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI Mark IS: 15683 operating temperature (-30)°to (50)° for class 13 B type of fire with 1 mtr. Hose pipe fitted with PVC bend horn complete in all respect. Inspection: Consignee. | — | — | — | 48,072 | |
| — | 80.00 | — | — | ||
| Supply of Red/Yellow/Black Highlighter Reflective Tape (50 mm. width) of grade retro reflective tape conform to IS 14221 or latest, BIS marked, Grade 2, Pressure type bonding for (Grade 1) R1-P. Inspection- Consignee. | — | — | — | 9,200 | |
| — | 8.00 | — | — | ||
| Supply of Integrated power supply (IPS) system as per RDSO Spec. No. RDSO/SPN/165/2023 (Ver.4.0) Amdt.1 or latest and also as per ER letter no-S.42/2/Vol.-III dated- 26.11.2025 (Typical Application Auto/IB/LC Hut) along with 200AH Low maintenance Lead Acid (LMLA) or Valve Regulated Lead Acid (VRLA ) Battery Bank with complete accessories as per the drawing. Inspection: RDSO. Payment: 70% on supply and balance on installation and testing. | — | — | — | 98,22,320 | |
| — | 8.00 | — | — | ||
| Installation, grouting, Testing and Commissioning of Integrated Power Supply System as per Specification No. RDSO/SPN/165/2023 Ver.4.0, Amdt.1 or latest. It will include initial charging of Battery, Installation of SPD/LVD, Installation wiring of SM Monitoring Panel, Wiring of Alarms/SPDs to data logger, wiring between IPS to SPD, Installation shall be done as per RDSO TANs, with best installation practices and PCCL by the authorized competent Engineer of the OEM | — | — | — | 5,60,656 | |
| — | 8.00 | — | — | ||
| Supply of Remote Terminal Unit (RTU) with 128 digital input & 16 analog input as per RDSO Spec. No. IRS (S) 99/2006 with Amdt.3.0 or latest. Inspection: RDSO.Payment: 80% on supply and balance on installation and Testing/SAT. | — | — | — | 20,26,872 | |
| — | 8.00 | — | — | ||
| Installation, wiring, testing & commissioning of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input & 16 analog input. It covers complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, RDSO/CLS Panel output power supply monitoring arrangement & DG sets, ELD , IPS,UFSBI, Block Instruments, SPDs, Auto Changeover Equipments/Modems, TFBC Alarms, AFDAS Alarms, RDPMS Alarms, 48 Volts Telecom supply, and interlinking and networking of Data logger. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.08.12.2011 or latest guidelines of Railway Board/RDSO/Zonal Railway. Networking of data logger includes extraction of data reports from the Control room. Exceptional reports are to be generated by a computer connected to a datalogger at the station and at a central location in the Control Room. Datalogger software should be able to generate exceptional reports for maintenance, safety and operations as per latest guidelines of Railway Board/RDSO/Zonal Railway. Datalogger to be installed at Site by OEM For networking, required communication channel (Quad/ OFC cable) will be arranged/provided by Rly in the Relay Room or in OFC/AUTO/EI Huts. The final commissioning will be done after filling up the Pre-Commissioning checklist (circulated by RDSO) with the OEM representative. Datalogger to be validated and commissioned before simulation test / SAT and put in network validation statement should be jointly signed by railway engineer (open line), railway engineer (construction) & OEM'S engineer before simulation test with name, designation and date. Payment for this item will be released only after submission of duly signed pre-commissioning checklist of data logger in standard RDSO format, joint signature of validation statement. OEM'S engineer will also impart training to rly staff at site for proper functioning /working and applications of data logger. | — | — | — | 1,99,784 | |
| — | 80.00 | — | — | ||
| Fabrication, supply and fixing aluminum ladder of size 25 X 25 X 5 mm., 200 mm. width, arrangements for drawing various wires in the battery, equipment and relay rooms. Inspection: Consignee. | — | — | — | 55,680 | |
| — | 8.00 | — | — | ||
| Supply of Tag block 200 way/160 way with PVC covers as per IRS:S-77/2006 (Rev.1) or latest &Drg. No. SA-24751 & 52. Requirement of each type shall be specified by Engineer-in- charge. NOTE: In case ABB type relays are proposed to be used with 100 way block then Two 100 way Tag Block will be considered as one 200 way Tag Block. Inspection: RDSO | — | — | — | 12,184 | |
| — | 20.00 | — | — | ||
| Supply of Domino units with cover plate as per approved panel diagram, each of size 54 x 34 mm. completely wired up similar to Siemens or similar make. Each domino units should have all the 15 contact terminals wired up. Inspection: Consignee. | — | — | — | 22,800 | |
| — | 2500.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) in cable termination rack in relay room, station building etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by the contractor (Lugs, eyelets, Power cables should be terminated with suitable lugs/eyelets wherever applicable). | — | — | — | 15,000 | |
| — | 8.00 | — | — | ||
| Supply of Gate (slave) Telephone with voice recorder as per RDSO Spec. No. RDSO/SPN/TC/51/2011 Rev.4.0. Inspection: RDSO. | — | — | — | 46,352 | |
| — | 8.00 | — | — | ||
| Installation, testing and commissioning of slave gate telephone. This Includes testing and commissioning, all installation related material to be supplied by the contractor as per site requirement | — | — | — | 6,592 | |
| — | 36.00 | — | — | ||
| Supply of Track feed Battery Charger as per RDSO Spec. No. IRS: S-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery. Inspection: RDSO. | — | — | — | 2,06,100 | |
| — | 110.00 | — | — | ||
| Supply of 2V/80AH uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Spec. No. IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO. | — | — | — | 4,82,240 | |
| — | 110.00 | — | — | ||
| Charging of 2V/80AH lead acid cell (Secondary cell) of various capacities as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by consignee. This includes installation and commissioning of the battery in circuit. Battery to be kept on a wooden rack. | — | — | — | 50,820 | |
| — | 40.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No. SA-20161-66/M or latest. To be procured from RDSO Approved sources. Inspection: RDSO | — | — | — | 8,000 | |
| — | 75.00 | — | — | ||
| Supply of Track Lead Junction Box (TLJB) made from FRP material including brass bolts and hylam board sheet with 4 terminals as per ER drawing no- SI/TYP/0096& ER Technical circular policy no-118 (Modified). Inspection: RITES/CONSIGNEE. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg. with L- 262 mm. W-212 mm. and H-90 mm. and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakelite terminal block fitted horizontally: each bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50 mm. long. Along with each TLJB, nickel chrome plated brass links (two nos. of adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35 mm., 380 mm. long, along with two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB to be made of one meter long 30 mm. X 30 mm. X 4 mm. angle (2 nos.) and 300 mm. long 30 mm. X 30 mm. X 4 mm. angle (1 no.) fixed at 50 mm. from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come along with holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied along with TLJB. Inspection:Consignee. | — | — | — | 3,38,025 | |
| — | 40.00 | — | — | ||
| Supply of B Type Choke as per RDSO Spec. No. IRS:S-65/83 (Amnd.1) or latest. Inspection: RDSO. | — | — | — | 2,41,040 | |
| — | 5000.00 | — | — | ||
| Supply of Channel Pins MS (Galvanized) single groove, 7 mm. suitable for 4 mm. dia. bonding wire as per Spec. No. IRS S-17 & RDSO Drg. No. S-69/M. Inspection: Consignee. | — | — | — | 25,000 | |
| — | 2000.00 | — | — | ||
| Supply of GI wire 8 SWG (4 mm. dia.) suitable for track circuit rail bonding. Inspection: Consignee. | — | — | — | 16,000 | |
| — | 100.00 | — | — | ||
| SUPPLY OF POLYMER POSITIVE TEMPERATURE COEFFICIENT DEVICE (PPTC) Resettable Fuses, for outdoor circuits. 30V/2.5A for track feed and 60V/1.1A in place of 24V/2A fuse and 120V/1.1A for signal lighting. Make- RAYCHEM, BOURNS, LITTLE FUSE, FUZETEC or TYCO. Quantity as per site engineer. Note- PPTC fuses are to be connected with crimped ring type lugs. ". Inspection: Consignee | — | — | — | 10,000 | |
| — | 36.00 | — | — | ||
| Installation wiring, testing and commissioning of DC track circuit as per approved track circuiting plan. The work includes fixing of track bonding (double) with 8 SWG soft GI wire, rail connector with GI wire and fixing with bond pin with galvanised iron wire, track jumpers (double) with signalling cable. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box, including drilling of 9/32" hole on rails where required. Erection, fitting of Track Lead Junction Box on two supports. The work shall be done as per instructions of Rly engineer at site. GI wire, bond pin, TLJB, Track relay, Track resistance, Track feed charger, Choke, wire coil, fuses, terminal, signaling cable will be supplied by Railways | — | — | — | 1,47,240 | |
| — | 50.00 | — | — | ||
| Supply of color light signal post 4.5 mtr. as per RDSO Spec. No. IRS:S-6-81 (or latest) and Drg. No. SA-23156 (Adv.), Alt-1 (or latest). Inspection: Consignee | — | — | — | 5,67,850 | |
| — | 50.00 | — | — | ||
| Supply of 4.5 meter Ladder for Color Light Signal as per RDSO Drawing No. SA-23153 (Adv.) or latest and Stage with Ladder as per Drawing No. S-2033/M (IRS) or latest & as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection: Consignee. | — | — | — | 4,96,800 | |
| — | 50.00 | — | — | ||
| Supply of 140 mm diameter Cast Iron (Grade-20) Signal base as per Drawing No. S- 2011/M and as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection: Consignee. | — | — | — | 3,16,000 | |
| — | 50.00 | — | — | ||
| Casting, concreting & curing of foundation for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips, Foundation Bolts, PVC Pipe, shuttering etc. as per Drg. No. S&T/C-42(NKG). | — | — | — | 5,08,300 | |
| — | 27.00 | — | — | ||
| Supply of FRP type color light signal unit 3 aspect complete as per Drg. No. SA- 23002/AIM with Latest amendment and as per RDSO Spec. no. RDSO/SPN/194/2006 Rev. 2.0 or latest. Inspection: RITES | — | — | — | 9,42,192 | |
| — | 20.00 | — | — | ||
| Supply of FRP type color light signal unit 2 aspect complete as per Drg. No. SA- 23003/AIM with latest amendments and as per RDSO Spec. no. RDSO/SPN/194/2006 Rev. 2.0 or latest. Inspection: RITES | — | — | — | 6,47,480 | |
| — | 3.00 | — | — | ||
| Supply of FRP type color light signal unit 4 aspect complete as per Drg. No. SA 23001/NM with Latest amendments and as per RDSO Spec. no. RDSO/SPN/194/2006 Rev.2.0 or latest. Inspection:Consignee. | — | — | — | 1,18,338 | |
| — | 50.00 | — | — | ||
| Erection of surface base, signal post, mounting of Color Light Signal up to 4 aspects complete on signal post, offset bracket, LED fixing, plumbing of the signal through sealing gap between Surface base and signal post, fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, termination tail cables, wiring of signal unit, fixing of EWS locks, and painting of one coat of red oxide and two coats of aluminium/enamel paints , black paint on post, ladder, Platform, ladder shoe as per practice. When the aspect is fixed on an offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. Painting of Signal unit with two coats of white inside and Black outside (Supply of surface base, offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, LED aspects, and wire coils will be supplied by Railways). (through bolts and nuts, cement, stone jelly 20/25mm dia. river sand, Signal Color Rings, all fixing bolts and nuts, teak wood, paints PVC/Nylon sleeves and all other miscellaneous materials for the work shall be supplied by the contractor) | — | — | — | 6,65,700 | |
| — | 35.00 | — | — | ||
| Supply, Fabrication of Retro reflective Nomenclature Board of size 254 mm. x 358 mm. made of 2 mm. thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE-IV) including fixing arrangement for fixing them on existing post per SEM and as per standard practice. Details of station, signal type and number to be obtained before supply. Inspection: Consignee. | — | — | — | 16,450 | |
| — | 35.00 | — | — | ||
| Supply, Fabrication of Retro reflective P / C / G marker made of 2 mm. thick aluminium sheet & high intensity prismatic grade retro reflective sheet (TYPE-IV) including fixing arrangement for fixing them on existing post per IRSEM and as per standard practice. Inspection: Consignee. | — | — | — | 24,290 | |
| — | 35.00 | — | — | ||
| Supply of LED signal lamps for Main color light Signal RED Aspect, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Spec. No. RDSO/SPN/199/2025 Revision.1.2 with Amendment - 1 or latest. Inspection: RDSO. | — | — | — | 3,23,330 | |
| — | 35.00 | — | — | ||
| Supply of LED signal lamps for Main color light Signal YELLOW Aspect, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Spec. No. RDSO/SPN/199/2025 Revision.1.2 with Amendment - 1 or latest. Inspection: RDSO. | — | — | — | 3,30,890 | |
| — | 35.00 | — | — | ||
| Supply of LED signal lamps for Main color light Signal GREEN Aspect, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Spec. RDSO/SPN/199/2025 Revision.1.2 with Amendment - 1 or latest. Inspection: RDSO. | — | — | — | 3,64,490 | |
| — | 8.00 | — | — | ||
| Fabrication, Supply and fixing of goods warning board or any other board with engineering grade reflective sticker of size 600 X 1000 mm. GI sheet, with MS angle of 75 mm. X 75 mm. X 6 mm. with 6 meter length including paint, excavation of pit and concrete foundation etc. as per the instructions of sight in-charge. All necessary materials to be arranged by the contractor). Inspection: Consignee. | — | — | — | 58,136 | |
| — | 8.00 | — | — | ||
| Provision of foundation for the signal/goods warning boards/all types of boards. (A pit of size 400 mm. x 400 mm. x 1500 mm. is to be dug and cement concrete foundation in the pit in the ratio 1:3:6 to be casted. The rail post/MS angle is to be erected up right in the foundation. | — | — | — | 12,384 | |
| — | 4.00 | — | — | ||
| Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 Revision.3 With latest Amdt. Inspection: RDSO. | — | — | — | 11,016 | |
| — | 4.00 | — | — | ||
| Jointing of 4 / 6 quad Signaling cable with Heat Shrinkable straight through Jointing Kit. All the materials required for the work are to be arranged by the contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After joining the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with the Railway Engineer. If any defect or any damage is observed during jointing, the contractor has to redo the joint free of cost. | — | — | — | 4,820 | |
| — | 35.00 | — | — | ||
| Excavation of trench at a of Depth of 1200 mm. and width of 300 mm., including marking of cable alignment, clearing of jungle, roots of trees, bushes, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil. NOTE: In case 1.2 m. depth of the trench is not achievable due to site conditions approval of officer in charge is to be obtained and payment shall be made on a prorate basis | — | — | — | 34,23,770 | |
| — | 200.00 | — | — | ||
| Trenching under Rails for crossing the track (Track Crossing) and refilling of trenches. The track crossing shall be done at right angles. The depth of the cable trench shall be 1.2 meter below the rail flange. The ballast shall be stacked separately while making the trench and the earth soil shall be stacked separately. While re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. This work has to be done under supervision of the supervisor of S&T. | — | — | — | 2,25,600 | |
| — | 150.00 | — | — | ||
| Cutting of platform surface (tile/slab/concrete) for a depth of 20 cm. & width of 10 cm.& refilling /reconditioning/ repairing the platform after laying pipe & cable. Cutting should be done with marble cutting machine in proper manner & restore the same as before in such a manner that the aesthetic of PF is not disturbed. | — | — | — | 65,550 | |
| — | 55000.00 | — | — | ||
| Laying of S&T Cables of various cores/pairs/quads in trenches/GI pipes/RCC pipes/DWC pipes/Trunking | — | — | — | 3,85,000 | |
| — | 100.00 | — | — | ||
| Manual Track crossing/ Road Crossing by Horizontal Boring method at culverts/track/pucca road. This also includes insertion of HDPE pipe of 110 mm./G.l. Pipe of 100 mm. in the bore drilled (HDPE pipe/GI pipe is to be supplied by Railway). | — | — | — | 1,63,400 | |
| — | 35.00 | — | — | ||
| Supply of Double Walled Corrugated (DWC) HDPE duct of outer Diameter 250 mm. and inner Diameter 217 mm. length of 6m. as per Specification RDSO/SPN/204/2011 Ver.1.1 Amd.1 or latest. The duct shall be supplied along with push-fit type 0-ring coupler or end cap. Inspection:Consignee. | — | — | — | 2,27,465 | |
| — | 6000.00 | — | — | ||
| Supply and laying of split DWC pipe of 250/217 mm.diameter in already dug cable trenches as per Drawing No.SK.9/11. The unit of RMT means two split pipes of 1 Mtr. each. Inspection for supply :RITES | — | — | — | 45,24,000 | |
| — | 1200.00 | — | — | ||
| Supply of Light class GI pipes 100 mm. dia. (thickness 3.6 mm.) as per IS 1239 (Part- 1):2004 or Latest with socket & coupling. Inspection: RITES | — | — | — | 15,91,200 | |
| — | 300.00 | — | — | ||
| Laying & Fixing of GI pipes 50 mm./100 mm. as per IS 1239 (Part1):2004 with socket & coupling on culverts and bridges. It includes installation of all material required for fixing arrangement. The contractor will install a flexible/corrugated HDPE pipe at the end of the GI pipe along with any masonry work (if required) to protect the cables from sharp edges and sudden bends. | — | — | — | 1,08,000 | |
| — | 80.00 | — | — | ||
| Breaking of metal/tar road and refilling after laying the cables. Repair of pucca roads to original state in level crossing area after cable laying. | — | — | — | 23,600 | |
| — | 9.00 | — | — | ||
| Supply of 12 core Armoured Mono mode OFC cable as per latest TEC Specification or latest. Inspection:Consignee. | — | — | — | 2,97,162 | |
| — | 9.00 | — | — | ||
| Supply of 40 mm. dia. permanently lubricated HDPE telecom: ducts (with chord) as per RDSO Spec. No. RDSO/SPN/TC/45/2013 Rev.2.0 with latest amendments or Latest in length of 1000 mtrs./roll For each km. of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Color WILL be specified by Railways. Inspection:RITES | — | — | — | 7,16,364 | |
| — | 9.50 | — | — | ||
| Laying of HDPE/DWC/GI Pipes. | — | — | — | 72,105 | |
| — | 9.00 | — | — | ||
| Blowing of armoured optic fiber cable (OFC Cable supplied by Railways) into the HDPE duct by using a blowing machine and associated works. 10% of OFC length to be blown extra on both ends of Duct i.e. total 20% of Duct length. Before blowing the duct integrity shall be tested. The payment shall be made after ensuring duct integrity and corrective action wherever required at his own cost. Payment will be made as per the length of Duct from which OFC is Blown. | — | — | — | 1,25,550 | |
| — | 6.00 | — | — | ||
| Supply of 24 fiber optical fiber cable straight joint enclosure (SJC) complete with all accessories along with enclosures with heat shrinkable splice protection sleeve as per RDSO Spec. RDSO/SPN/TC68/2014 Revision 1.0, Amdt.1.0 or latest. Splice losses in no case should be more than 0.1 dB. Inspection: Consignee. | — | — | — | 33,032.7 | |
| — | 6.00 | — | — | ||
| Jointing, terminating & splicing of 24 fiber optic fiber cable and fixing of termination box/FDF/placing of joint closures in the pit required at various locations including transportation of all the jointing & terminating materials from railway store to the work site and returning leftover materials to the railway store. | — | — | — | 64,362 | |
| — | 6.00 | — | — | ||
| Excavation of the jointing pit and provision of RCC/FRP joint /Loop chambers of 90 cm. Inner dia. 60 cm. depth and 3mm thickness with two pieces of top cover with hooks each and bottom cover with hole for drainage and cable entry as per Drg. No. RAILTEL/SR/OFC/ 2009/12 and as directed by Engineer to be provided at every joint location and at every Kilometer loop etc., The chamber shall be filled with sand mixed with ariti-stermic power, back filling and ramming of trench after HDPE duct laying, splicing and commissioning | — | — | — | 1,52,880 | |
| — | 30.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1:3:6. Items include ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). | — | — | — | 1,35,990 | |
| — | 400.00 | — | — | ||
| Supply, transportation at site and Installation of RCC cable route marker engraved and painted on both side along the route at every 50 meter and at route diversion. The cable marker is to be fabricated as ER TECHNICAL POLICY CIRCULAR NO.108. Fixing work is to be done as per extant practice of E.Rly. and as per Railway site supervisor.50% payment will be done after supply of material. Material to be supplied at Site. | — | — | — | 3,52,800 | |
| — | 4.00 | — | — | ||
| Supply of Fiber Distribution Management system (FDMS)/LIU for 12 Fiber complete with all accessories such as patch cord & pigtail as per TEC Spec. GR/FDM/01/02 April '2007 or latest. This includes supply of installation accessories as per technical specification. Inspection: RITES/Consignee. | — | — | — | 10,392 | |
| — | 4.00 | — | — | ||
| Installation, splicing and commissioning of Fiber Distribution Management system (FDMS) for 12 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec. with the latest amendment. The sundry material if required any to be supplied by the contractor. | — | — | — | 8,344 | |
| — | 20.00 | — | — | ||
| Supply of OFC SC/SC Patch Cord 5 m Length. Inspection: Consignee. | — | — | — | 4,060 | |
| — | 75.00 | — | — | ||
| Supply of full size apparatus case (GKP type) (as per Drawing No. SW SK NO. 4/90 & other applicable GKP SW Drawing). This includes supply of a location box (GKP type) with 'E' type lock & key, fitted on the location door on both side, E Type lock (ward No. will be specified by Engineer-in Charge) as per RDSO Drg. No. SA-3376 and Key to Drg. No. SA-3377 as per RDSO Drawing No. S-11500. Inspection: RITES | — | — | — | 13,15,725 | |
| — | 75.00 | — | — | ||
| Casting, concreting and curing of concrete foundation (in ratio 1:3:6), erection and installation of full size apparatus case as per Drg. No. S&T/C-6/98(NKG). This includes the cost of all materials required for fixing holding down bolts, casting, concreting. Note: Bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation. This also includes the bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: Painting the apparatus case inside and outside with one coat of red oxide, two coats of aluminium paints outside and white paint inside | — | — | — | 10,27,875 | |
| — | 75.00 | — | — | ||
| Fixing by slotted angle, wiring of terminal strips, hylam strip, relays, fuses with base, fixing of HDHMR shelves for full size apparatus case with Termination & Earthing of cables and wiring with lettering both inside and outside as required including supply of slotted angles, ferrules for marking and miscellaneous materials per location to be supplied by contractor (all materials except Wires, relay, terminal strips, Bakelite strip, fuses with base and HDHMR shelves to be supplied by the contractor). It includes letter painting both inside and outside as per ER practice. NB- Multi strand cables and power cable to be terminated with proper lugs and required buss bar etc. to be supplied by the contractor. Inspection: Consignee. | — | — | — | 4,56,675 | |
| — | 5.00 | — | — | ||
| Alteration/modification in the existing location boxes (full size), fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same | — | — | — | 17,535 | |
| — | 20.00 | — | — | ||
| Supply of HDHMR (High Density, High Moisture Resistance) Shelf for Full Location Box Size 950 x 400 x 25 mm. Inspection: Consignee. | — | — | — | 16,500 | |
| — | 28.00 | — | — | ||
| Supply of Phenolic laminated Sheet/Hylam sheet, grade P3 in standard size of 1220 X 1220 x 10 mm. as per Spec. No. IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: Consignee. | — | — | — | 1,55,456 | |
| — | 3500.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) as per RDSO Spec. No. RDSO/SPN/189/2004 With latest amendments. The color will be decided by the Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) Inspection: RDSO | — | — | — | 2,41,500 | |
| — | 350.00 | — | — | ||
| Supply of End plate 2.5 mm./0.091 in thick RDSO/SPN/189/2004 With latest amendments. Inspection: RDSO. | — | — | — | 4,550 | |
| — | — | — | RDSO | ||
| — | — | — | Spec. | ||
| — | 350.00 | — | — | ||
| Supply of End Stopper 10 mm./0.0394 in width as per RDSO Spec. No. RDSO/SPN/189/2004 With latest amendments. Inspection: RDSO. | — | — | — | 4,550 | |
| — | 105.00 | — | — | ||
| Supply of Carrier Rails for above 35 mm. x 7.5 mm., 1 mm./0.039 in thickness un- slotted type as per site requirement. Inspection: Consignee. | — | — | — | 13,440 | |
| — | 8.00 | — | — | ||
| Supply of 8 channel Earth Leakage Detector (ELD) with configuration specified by Engineer In charge and as per specification RDSO/SPN/256/2025, Version 2.0 or latest with insulated tester, test probes, Mounting stand and Fuse board to isolate from distribution board as per requirement of channels. Inspection: RDSO. | — | — | — | 6,97,384 | |
| — | 8.00 | — | — | ||
| Installation, wiring, Calibration, testing and commissioning of Earth Leakage detector 8 channels as per specification RDSO/SPN/256/2025, Ver2.0 or latest and as per instructions of Rly. engineer in charge. | — | — | — | 92,712 | |
| — | 200.00 | — | — | ||
| Supply of Tinned Copper LUGs for fitting Cable Size: 10 Sq.mm., Barrel Inner Dia: 4.7 mm., Barrel Outer Dia: 7.10 mm., Barrel Length: 10mm., Stud Hole Center Dia: 9.9 mm., Palm Width: 12.6 mm., Thickness: 1.8 mm., Lug Length: 27 mm., Thimble Type : Ring. Inspection: Consignee. | — | — | — | 2,400 | |
| — | 100.00 | — | — | ||
| Supply of Tinned Copper LUGs for fitting in Cable Size : 16 Sq.mm., Barrel Inner Dia: 6.4 mm., Barrel Outer Dia 8.0 mm., Barrel Length: 12.2 mm., Stud Hole Center Dia: 10 mm., Palm Width: 12.6 mm., Thickness: 1.8 mm., Lug Length: 28-30 mm., Thimble Type: Ring. Inspection: Consignee. | — | — | — | 1,600 | |
| — | 100.00 | — | — | ||
| Supply of Tinned Copper LUGs for fitting in Cable Size : 35 sq. mm., Barrel Inner Dia :13 mm., Barrel Outer Dia: 17 mm., Barrel Length: 12.2 mm., Stud Hole Center Dia: 10 mm., Palm Width: 12.6 mm., Thickness: 1.8 mm., Lug Length: 28-30 mm., Thimble Type: Ring. Inspection: Consignee. | — | — | — | 3,500 | |
| — | 500.00 | — | — | ||
| Supply of 1 x 10 (140/0.3) Sq.mm. multi strand copper power wire as per RDSO Spec. No. IRS:S-76/89 (Amdt.3) or latest. The color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO. | — | — | — | 67,000 | |
| — | 300.00 | — | — | ||
| Supply of 1 x 16(126/0.3) Sq.mm. multi strand copper power wire as per RDSO Spec. No. IRS:S-76/89 (Amdt.3) or latest. The color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO. | — | — | — | 51,900 | |
| — | 70.00 | — | — | ||
| Supply of 1 x 35 (276/0.4) Sq.mm. multi strand copper power wire as per RDSO Spec .No. IRS:S-76/89 (Amdt.3) or latest. The color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO. | — | — | — | 14,980 | |
| — | 70.00 | — | — | ||
| Supply of Copper bonded steel electrode of 3.0 m. long, 17.2 mm. dia. with copper bonding thickness of minimum macrons and UL listed as per RDSO Spec. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO/RDSO/E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. Inspection: RDSO Note: These electrodes to be used in ring earth/ perimetric earth. | — | — | — | 3,40,060 | |
| — | 21.00 | — | — | ||
| Supply of Copper Strip 25 X 6 mm. as per specification No. IS:1897-2008. Inspection: Consignee. | — | — | — | 18,333 | |
| — | 280.00 | — | — | ||
| Supply of Copper tape for BRC(25 X 2) mm. as per specification No. IS:1897-2008. Inspection: Consignee. | — | — | — | 88,760 | |
| — | 6400.00 | — | — | ||
| Supply of Earth Enhancement material for use in earth and in ring/perimetric earth as per Specification No. RDSO/SPN/197/2016 Ver.1.0 or latest. Inspection: RDSO | — | — | — | 9,40,800 | |
| — | 70.00 | — | — | ||
| Installation of Unit Maintenance Free Earth as per RDSO Spec. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO/RDSO/E&B/001 or Latest. It includes (i) Digging the earth in normal soil to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compounds (Approx.30 Kg.) (iv) Supply, fixing of CC cover 1.5 ft. x 1.5 ft. 1 ft. wall thickness 2 inch with cover 3 inch thickness.(v) exothermic welding to connect with other Earth pit,MEEB. | — | — | — | 2,63,270 | |
| — | 480.00 | — | — | ||
| Supply of 50 mm. x 6 mm. GI tape as per specification IS:2629-1985 for interconnecting earth electrodes in ring / perimetric earth. Inspection: Consignee. | — | — | — | 2,59,680 | |
| — | 40.00 | — | — | ||
| Installation, laying of GI Tape (50 X 6 mm.) for connecting Main earth pit to other earth pit in case of loop/ring/perimetric earth as per RDSO TAN no. STS/E/TAN/3006 , Ver.3.1 by providing earth enhancement material alongwith GI Tape. Note: 'No' in the unit column indicates 'per pair of earth pit'. | — | — | — | 4,000 | |
| — | 16.00 | — | — | ||
| Supply and Execution of Exothermic Welds for more than 16 sq. mm. wire. This includes a Welding Kit, Welding Powder, Mould and other necessary materials. Note - No. in unit column indicates per welding. Inspection:Consignee | — | — | — | 7,968 | |
| — | 40.00 | — | — | ||
| Supply and Execution of Exothermic Welds for upto 16 sq.mm. wire. This includes a Welding Kit, Welding Powder, Mould and other necessary materials. Note- No. in the unit column indicates per welding. Inspection: Consignee. | — | — | — | 15,280 | |
| — | 105.00 | — | — | ||
| Installation of MEEB/SEEB/BRC with the insulators (As per the instruction of Site Engineer). Fitting materials & Insulator (Dough Moulding Compound Conical type of different Size) as per the site requirement to be supplied by the contractor. Note: 'No' in the unit column indicates 'per insulator'. | — | — | — | 3,360 | |
| — | 40.00 | — | — | ||
| Supply of Nut Bolts, Washer (Stainless Steel) as per the site requirement (One set consists of 1 Nut, 1Bolt, 2 washer & 2 spring washer) Note: Hex Nuts, bolts and washers of size 5/16". Inspection: Consignee. | — | — | — | 1,080 | |
| — | 160.00 | — | — | ||
| Supply of earth electrode (GI PIPE) as per CSTE/ER's (Drg. No. SI/TYP/0097 dated 25.03.25). Inspection: By RITES [for value of material above Rs.5.0 lakhs]. Inspection: Consignee. | — | — | — | 3,01,760 | |
| — | 800.00 | — | — | ||
| Supply of MS FLAT (Spec. No.226 STD or latest) of size 35 mm. x 6 mm. as per CSTE/ER'S DRG. NO. S&T-1/2007 (or latest). (STANDARD MINIMUM LENGTH OF 5M OR MULTIPLE OF 5M) Inspection:Consignee. | — | — | — | 1,84,000 | |
| — | 160.00 | — | — | ||
| Fixing of earth electrode including laying and installation of MS flat of size 35 mm. x 6 mm. with length 5 mtr. or as per extant practice of Eastern Railway. As per PCSTE/ER's Drg. No. SI/TYP/0097 dated 25.03.2025 or latest. For apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Where required necessary holes to be drilled on the MS Flat. Full threaded bolts of 10 mm. dia. and length 40 mm should be welded in the apparatus cases in such a way that the MS flat at the apparatus case end can be fixed from outside or from inside (bolts of 10 mm. dia. and length 40 mm. should be supplied by the contractor). Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Sig. Cable as provided by Railway is also to be laid and terminated on Earth Electrode and to GI Wire/GI Flat in Location Box. | — | — | — | 2,34,240 | |
| — | 160.00 | — | — | ||
| Provision of cement concrete enclosure for earth electrodes as per CSTE/ER's (Drg. No. SI/TYP/0097 dated 25.03.25).Inspection: Consignee. | — | — | — | 1,15,200 | |
| — | 8.00 | — | — | ||
| Supply and installation of "FRANKLIN ROD" as per NFPA-780 Standardsas per ER Drawing No.-SI/TYP/103. Installation to be done as per IEC standard. It also includes connection of down conductor with Franklin Rod and running of down conductor through PVC pipes and connecting the same to nearby earth electrode. All material required for installation to be supplied by the contractor. Inspection:Consignee. | — | — | — | 5,28,744 | |
| — | 80.00 | — | — | ||
| Supply of copper bonded steel conductor of size 50 Sq.mm. as per IEC/EN 62561-2 (VDE 0185-561-2) for connecting A-class LA to earth. Inspection: Consignee. | — | — | — | 25,600 | |
| — | 8.00 | — | — | ||
| Supply of Lightning Strike recorder LSC 6 digits shall be weather proof type. It should have a 6-digit event count & the capacity to count the smallest strike of intensity 3 KA. It should be a voltage sensing type counter so that it will register nearby strikes & static discharge due to induction effect as per IS 2309:1989 or latest. Make-Bakiral or better. Inspection:Consignee | — | — | — | 98,672 | |
| — | 8.00 | — | — | ||
| Fixing of Down Conductor through HDPE Pipe for A'- Class Surge Arrestor. HDPE pipe will be supplied by Rly. Note: No. in Unit column indicates per Arrestor. | — | — | — | 4,984 | |
| — | 72.00 | — | — | ||
| Supply of Class C, Type 2 Protection for 60-100V AC/DC/24-60V. Supply as per Clause No.3.11.2 of Specification No. RDSO/SPN/165/2023 Ver.4.0 or latest. The Class C SPD shall be with pluggable type, with indication and potential free contact. The supplier should submit an OEM certificate, KEMA, UL Certificate with the material, for connection between L1-L2, L1-E & L2-E. Inspection: RDSO | — | — | — | 63,720 | |
| — | 400.00 | — | — | ||
| Supply of Fuse terminal block with LED indication up to 2.5 sq. mm. screw type one in one out suitable for 400mA/630mA/1A/1.6A/2A/4A/6.3A/8A10A or as decided by Engineer in charge as per RDSO SPN/189/2004 or latest. Inspection: RDSO. | — | — | — | 27,200 | |
| — | 1500.00 | — | — | ||
| Supply of Fuse links of (400 mA, 630 mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A, 250mA as per RDSO Spec. No. RDSO/SPN/189/2004 With latest amendments Inspection: RDSO. | — | — | — | 84,000 | |
| — | 200.00 | — | — | ||
| Supply D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge. Inspection: RDSO. | — | — | — | 6,800 | |
| — | 500.00 | — | — | ||
| Supply of D type fuse link non indicating type low voltage non detonating, capacity 2A/6A/10A as per specification IRS:S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge.Inspection: RDSO. | — | — | — | 17,500 | |
| — | 8.00 | — | — | ||
| Supply of the following resistors/condensers/diodes. a) 50V, 470 pF electrolytic capacitor - 20 Nos. b) 50V, 1000 pF electrolytic capacitor - 20 Nos. c) 50V, 2200 pF electrolytic capacitor- 20 Nos. d) 100 Ohms, 10W wire wound resistance - 20 Nos. e) BY127 diode - 10 Nos. f) PVC Insulation tapes of 25m. length - 25 Nos. Inspection- Consignee. | — | — | — | 29,848 | |
| — | 95.00 | — | — | ||
| Supply of Q-Series LED ECR(Universal Type i.e.QECX-61),4F/4B complete with plug board (base plate), connectors, retaining clips etc. and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.1and RDSO Spec. No. IRS:S-34 & S-23 with Amdt. upto date as applicable or latest. Inspection: RDSO. | — | — | — | 6,08,570 | |
| — | 30.00 | — | — | ||
| Supply of Contactor Unit (QBCA1 Type), 24 V DC, 2F(HD)/4B complete with plug board (base plate), connectors, retaining clips etc. and conforming to BRS-943 and RDSO Spec. No. IRS:S-34 & S-23 with Amdt. upto date as applicable or latest. Inspection: RDSO. | — | — | — | 2,53,920 | |
| — | 45.00 | — | — | ||
| Supply of Q-Series Line Relay (QNA1 Type), AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS-931A and RDSO Spec. No. IRS:S-34 & S-23 and S-60 or latest.Inspection: RDSO. | — | — | — | 2,18,115 | |
| — | 250.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc. and conforming to BRS-930 and RDSO Spec. No. IRS:S-34 & S-23 with Amdt. upto date as applicable or latest. Inspection: RDSO. | — | — | — | 10,93,000 | |
| — | 30.00 | — | — | ||
| Supply of Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS- 935A and RDSO Spec .No. IRS:S-34 & S-23 with Amdt. upto date as applicable or latest. Inspection: RDSO. | — | — | — | 2,16,240 | |
| — | 36.00 | — | — | ||
| Supply of Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS:939A & 966(Appendix F2) and RDSO Spec No. IRS:S-34 & S-23 with Amdt. Upto date as applicable or latest. Inspection: RDSO. | — | — | — | 1,71,972 | |
| — | 36.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay(QSPA1 Type), 24V DC, 8F/4B along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS-933A and RDSO Spec. No. IRS:S-34 & S-23 & S 60 with Amdt. upto date as applicable or latest. Inspection: RDSO. | — | — | — | 2,34,288 | |
| — | 14.00 | — | — | ||
| Supply of Relay fail-safe electronic time delay device with fixed timing of 60 seconds and conforming to RDSO Spec. No. IRS:S-61/2000 with Amnd.1 or latest mounted on Q-series relay base & covered complete with connectors, retaining clip etc. Inspection: RDSO | — | — | — | 37,380 | |
| — | 14.00 | — | — | ||
| Supply of Fail safe electronic flasher RDSO/SPN/173/2002 Amdt.2 or latest. Inspection: RDSO. | — | — | — | 75,712 | |
| — | — | — | RDSO | ||
| — | — | — | Spec. | ||
| — | 8.00 | — | — | ||
| Preparation and Supply of new Signal Interlocking Plan (SIP) based on approved Engineering Scale Plan (ESP) for LC Gate Note: The contractor shall supply tentative SIP 2 Copy for checking in paper print and after correction if any, submit (04 copies) for approval of Railway along with AutoCad file. After getting approval on tentative SIP, the final SIP shall be submitted in tracing paper (01 copy). 6 Copies in paper print/Ammonia print of Final Approved SIP to be Submitted to railways. Scanned copy of approved SIP and the AutoCAD file final version to be shared as soft copy with Railway in a suitable storage device. Inspection: Consignee. | — | — | — | 2,26,096 | |
| — | 8.00 | — | — | ||
| Preparation and Supply of Gate working Rule Diagram (GWRD) based on approved Signal Interlocking Plan (SIP) for s LC Gate. Inspection: Consignee. Note: The contractor shall supply tentative GWRD in paper print (04 copies) for approval of Railway along with AutoCad file. After getting approval on tentative SWRD, the final SWRD/GWRD shall be submitted in tracing paper (01 copy). After getting approval, 6 copies in paper print/Ammonia print and scanned copy of approved SWRD and the AutoCAD file final version to be shared as soft copy with Railway in a suitable storage device | — | — | — | 1,28,448 | |
| — | 8.00 | — | — | ||
| Design in AUTOCAD and submission of two draft copies of Complete Outdoor Particular such as Cable Route Plan, Cable Corage Plan, Cable Termination Rack/Power Rack Particular, Track Bonding, and Location Box Particular along with NI wiring/NI Relay Disposition chart. One copy will be returned either duly approved or for resubmission for approval after incorporating the changes as required by Railways. After approval, one approved Tracing film copy & six copies (Ammonia Print or print as approved by Railway) of above drawings along with six copies of SIP and SWRD/GWRD in Plastic Covers. All above drawing to be scanned including SIP & SWRD, bound in 6 different booklet with Rexin Cover (Each booklet shall have minimum 10 spare plastic transparent sheet) and a soft copy to be submitted in a Pen Drive for following categories of Stations: Inspection: Consignee. | — | — | — | 3,28,600 | |
| — | 8.00 | — | — | ||
| Design of circuits and plans to suit layout as per Signalling Interlocking Plan of LC GATE. This will include supply of Control cum Indication panel diagram, wiring diagrams (Indoor and outdoor), Relay rack/Relay arrangements, Bus bar details, Fuse analysis, contact analysis, Relay room tag block analysis, panel tag block analysis, Power panel diagram, IPS wiring diagram, Auto change over diagram, Power equipment arrangement Axle counter wiring diagram and all other relevant drawings. Submission of Two sets of prints with all correction for Railway's approval. Approved copy (06 Sets) of all drawings in plastic folders along with the original tracings in spiral bound with editable AutoCAD file latest version. | — | — | — | 1,00,424 | |
| — | 8.00 | — | — | ||
| Testing and commissioning the entire signalling installations jointly with the Railway representative at site at LC gates covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. | — | — | — | 90,176 | |
| — | 300.00 | — | — | ||
| Lettering / Numbering of termination particulars, equipment names etc., legibly and neatly inside full size location boxes. This includes supply of paints of make Asian Paints/ Nerolac / Dulux / Berger or better. Note: Location boxes in sl. no. 86 of this schedule are excluded in this work. | — | — | — | 61,500 | |
| — | 215.00 | — | — | ||
| Painting of existing color light Signals as per standard practice. The work involves scraping of old paint and two coats of aluminium enamel paint on the Signals & White paint inside signal unit and X mark on signal unit backside with white paint, Painting of Signal Unit, ladder, platform etc. complete as instructed by Railway representative at site (Paint and all other miscellaneous materials required for the work shall be supplied by the Contractor).Note: Signals in sl. no. 52 of this schedule are excluded in this work. | — | — | — | 3,93,665 | |
| — | 300.00 | — | — | ||
| Painting of existing FULL SIZE apparatus cases without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying two coats of Aluminium paint outside & two coats of white paint inside apparatus cases, painting of termination, equipment and number particulars on apparatus cases as instructed by Railway representative at site (Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor). Note: Location boxes in sl. no. 85 of this schedule are excluded in this work. | — | — | — | 5,32,200 | |
| — | 300.00 | — | — | ||
| Painting of Point machine and ground connections by two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. ( Point machine by Black enamel and ground connection by Red oxide). | — | — | — | 87,900 | |
| — | 8.00 | — | — | ||
| Supply of Current Clamp Meter of Model Fluke 317 or similar with the following specification. 1. True RMS responding. 2. Voltage - DC 600V, AC 600V, DC accuracy - ±1% + 4 digit. 3. AC accuracy - ±1.5% + 5 digit. 4. Current - DC 600A, AC 600A, AC accuracy: - ±1.5% + 5 counts, AC / DC current measurement. 5. Unique 40A low frequency measurements capability with 0.O1A resolution. 6. Special filter circuit to enable accurate measurement of PWM output. 7. Additional measurement of resistance. 8. Continuity check feature. 9. Data hold features with large, easy to read backlight display. 10. Calibration certificate. 11. 1 year warranty. Inspection:Consignee. | — | — | — | 1,59,176 | |
| — | 8.00 | — | — | ||
| Supply of true RMS 5 digit 60000 counts Digital Multi Meter with the following specification. 1. Frequency range - 6Hz to 1MHz mV AC. 2. Bandwidth - 10kHz. 3. AC voltage range - 1 mV - 1000V, ± 0.5%. 4. DC voltage range - 1 micro V - 1000V, ±0.05%. 5. AC current range - I micro A - 10A, ± 0.5%. 6. DC current range - 1 nA - 10A, ± 0.2%. 7. Capacitance range - 1pF - 10000pF. 8. Data logging - 32000 Readings. 9. Dual display - Available. 10. Other features - Shall have temperature measurement, diode, continuity, duty cycle measurement, self battery voltage measurement, low pass filter, Mm, Max and average value recording, back light, bar graph, protective rubber holster. Inspection:Consignee. | — | — | — | 1,20,112 | |
| — | 60.00 | — | — | ||
| Supply of Hydrometer as per IS: 3104 (Part II) -1982 or latest. Inspection: Consignee. | — | — | — | 16,440 | |
| — | 20000.00 | — | — | ||
| Transportation of materials from any Stores to Site and vice-versa including loading and unloading , lead above 50 km. Note: in unit column Number means PTPK ( Per Trip Per Km) | — | — | — | 1,40,000 | |
| — | 7.00 | — | — | ||
| Supply of Steel Plain Almirah with 4 adjustable slaves. Size: 1980 mm. height, 915 mm. width and 485 mm. depth. Make: Godrej Storewel Plain Large or Better of reputed brand. Inspection: Consignee | — | — | — | 1,51,452 | |
| — | 7.00 | — | — | ||
| Supply of Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cm. X 68 cm. X 75 cm.) or Superior of reputed brand. Inspection: Consignee. | — | — | — | 1,13,708 | |
| — | 15.00 | — | — | ||
| — | 8.00 | — | — | ||
| — | 8.00 | — | — | ||
| — | 8.00 | — | — | ||
| — | 8.00 | — | — | ||
| — | 8.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Modified_Cable_cut_JPO_NO._94.pdf Annexure I
ATTACHMENT
AllAnnexure.pdf
ATTACHMENT
TENDERDOCUMENT.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
GCC correction slip 1
ATTACHMENT
GCC correction slip2
ATTACHMENT
mergedGCCCorrectionslip3456.pdf GCC correction slip3456
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf GCC correction slip78910
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14.07.2022.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
ATTACHMENT
mergedGCCCorrectionslip3456.pdf
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf
ATTACHMENT
2018-CE-I-CT-9dtd.pdf
ATTACHMENT
Annexure-C.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
GCCCorrectionslip11.pdf
ATTACHMENT
Modified_Cable_cut_JPO_NO._94.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .