| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC 369 KRISHNA BHAVAN DHARMSALA ROAD CINEMA CHURAHA HARDOI UTTAR PRADESH 241001 | HARDOI | UTTAR PRADESH | 241001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.5 L+₹64,205 (2.23%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.8 L+₹2.9 L (10.2%)Rejected-Finance 0 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹31.8 L+₹2.9 L (10.2%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹32.1 L+₹3.3 L (11.3%)Rejected-Finance 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L5 | Rejected-Finance Being L5 |
Tender Value
₹38.2 L
EMD Value
₹76,400
Closing Date
21 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF DEFICIENT STREET LIGHTS WITH POLES AND CONNECTED ITEMS ALONG CARIAPPA ROAD AND SUBHASH MARG UNDER GE E/M LUCKNOW
2024_MES_667887_1
GE/EM/LKO/EXT(ELECT)/T-59 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
7 documents required · 7 mandatory
₹0
₹76,400
Yes
29 Oct 2024
25 Jul 2024
23 Sept 2024
25 Jul 2024
21 Sept 2024
9 Aug 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning, filling in including spreading levelling watering and well ramming in layer n.exc 25 cm thick using excavated soil all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
M&L for laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed
M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
Material & Laying, for jointing and testing LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 4 core, complete all as specified laid in trenches / laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 8 above but cable of size 25 Sqmm 4 core.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply drawing, connecting and testing 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
Supply and errection 07 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450 mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendation and one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250 mm on bracket and 150 mm on pole's cap including all RCC work type (1:2:4) type B-1 including 04 Nos foundation nut bolt and plate as per pole manufacturer's drawing and earth work all as per requirement complete all as specified and directed. Note:- Cost of construction of RCC foundation including construction material, necessary earth work and excavaton as per manufacturer design for above pole complete all as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate.
Supply and fix 70 W pressure Die cast aluminium housing street light with system lumen of 9800 lm & system efficacy of 140 lm / W, IP66, IK10, Single piece die cast including spigot, dia 48-76 mm, LED Lifetime (L70B50) 75K Hrs with integrated optical cover, Street light should have standalone lighting control system with AUTO on / off based on Dusk / Dawn timings, preset time setting with monthly variation (Jan to Dec.), inbuilt Real time clock for switching, includes dimming profile for energy savings, drift not exceeding max 2 mins per year, clock retention upto five years, auto switching off secondary power for module, dimmable driver based on PWM control, dim to off with High / Low Voltage cut off with 440V protection for 8 hrs for complete luminaire including driver and Astro module, EMI / EMC complaint as per EN55015,IEC61547, surge protection as per IEC 61000-4-5,driver meeting IEC61347, complete luminaire meeting IEC60598-2-3-2002, Luminaire manufacture shall provide LM 79 report from NABL / UL accredited lab & LM80 report issued by LED manufacturer, both the fixture and Driver should be of same make & must have separate BIS approval complete all as specified & directed.
Prime power system (BID ID -3096106)
A S ENTERPRISES (BID ID -3089077)
abhinav enterprises (BID ID -3096063)
M/s Vatsh Raj and co (BID ID -3096258)
OM NAMAH SHIVAY ENTERPRISES (BID ID -3099523)
M/s A.K Construction (BID ID -3095894)
Ajanta Associates (BID ID -3096143)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .