| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹45.0 L Quoted ₹45.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹47.0 L+₹1.8 L (4.03%)Rejected-Finance GROUND FLOOR MH ROAD UDHAMPUR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹47.0 L+₹1.8 L (4.03%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹47.3 L+₹2.1 L (4.62%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹47.3 L+₹2.1 L (4.62%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹49.9 L+₹4.7 L (10.3%)Rejected-Finance | ₹49.9 L+₹4.7 L (10.3%) | L4 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | VIRINDER SINGH L4 | M/S DHARAM & SONS ENTERPRISES L2 | M/S N K POWER SYSTEMS AND PROJECTS L1 | DAVINDER SINGH L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Lt control panel designing, fabrication, providing,installation,testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. The panel shall be dust and vermin proof fabricated out of 14/16 SWG CR Sheet supported on M.S angle of suitable size and provision for erection/ fixing it on the ground/wall.The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should have equipped with following components, complete all as specified and directed by Engr-in-Charge :- | 6 | Each | 5,00,000 ₹30,00,000 | 3,50,000 ₹21,00,000 Lowest | 4,60,073 ₹27,60,438 | 4,60,000 ₹27,60,000 |
| 1.01(a) Soft Stater suitable for 270 H.P induction motor. (i) The soft stater shall be designed, built and tested according to the lastest editions of application IEC standards,i.e EN60947-4-2. Soft stater shall be thyristor based with operation voltage: 208 - 600vac,50/60 Hz. (ii) The soft Stater shall have coated PCBAs to withstand harsh environments. (iii) The soft stater shall integrate motor and ,load protection, which shall under no cirsumstances be disabled when the integrated bypass is used, Motor overload Protection, Motor Underload Protection Underload protection over voltage & under voltage protection, single phase short circuit and thermal protection, Loacked Rotor Protection Manual or Automatic Reset,Thermal Memory, Thermal memory Thermal Capacity Reset Level, Phase Reversal. (b) To achieve type1 corrdination, MCCB for 270 HP induction motor, 4 Pole,50 KA,lcs=100% lcu. (c) To achieve type2 corrdination , semiconductor fuses of suitable rating. (d) Line Contactor of suitable rating equivalent to AF370. (e) Starter should consist of MPCB ( Motor Protection circuit breaker) of suitable capacity of the starter. (f) The panel should have ammeter digital type with CTs and selector seitch of suitable capapcity. (g) Voltmeter digital type with selector switch -01 No of suitable capacity. (h) Set of indicating lamp LED type -01 Set. (j) The auxiliary support of SPD (Surge protection device) Protected shall be provider. (Note: Lt panel board should be as per IS/IEC 61439-1:2011 & IS/IEC 61439-2:2011) | |||||||
| 2.00 | M&L for Lt control panel designing,fabrication,providing,installation,testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. The panel shall be dust and vermin proof fabricated out of 14/16 SWG CR Sheet supported on M.S angle of suitable size and provision for erection/ fixing it on the ground/wall.The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should have equipped with following components, complete all as specified and directed by Engr-in-Charge :- | 1 | Each | 4,00,000 ₹4,00,000 | 3,00,000 ₹3,00,000 Lowest | 3,70,073 ₹3,70,073 | 3,90,000 ₹3,90,000 |
| 2.01(a) Soft Stater suitable for 170 H.P induction motor. (i) The soft stater shall be designed, built and tested according to the lastest editions of application IEC standards,i.e EN60947-4-2. Soft stater shall be thyristor based with operation voltage: 208 - 600vac,50/60 Hz. (ii) The soft Stater shall have coated PCBAs to withstand harsh environments. (iii) The soft stater shall integrate motor and ,load protection, which shall under no cirsumstances be disabled when the integrated bypass is used, Motor overload Protection, Motor Underload Protection Loacked Rotor Protection Manual or Automatic Reset,Thermal Memory, Thermal memory Thermal Capacity Reset Level, Phase Reversal. (b) To achieve type1 corrdination, MCCB for 170 HP induction motor, 4 Pole,50 KA,lcs=100% lcu. (c) To achieve type2 corrdination , semiconductor fuses of suitable rating. (d) Line Contactor of suitable rating equivalent to AF370. (e) Starter should consist of MPCB ( Motor Protection circuit breaker) of suitable capacity of the starter. (f) The panel should have ammeter digital type with CTs and selector seitch of suitable capapcity. (g) Voltmeter digital type with selector switch -01 No of suitable capacity. (h) Set of indicating lamp LED type -01 Set. (j) The auxiliary support of SPD (Surge protection device) Protected shall be provder. (Note: Lt panel board should be as per IS/IEC 61439-1:2011 & IS/IEC 61439-2:2011) | |||||||
| 3.00 | Supply , fixing, commissining and testing in replacement of Fully automatic star delta motor starter in sheet steel enclosure type HGS series with single phase protection feature motor rating AC 3 phase 415 volts, 50 Hz for motor of capacity 100 HP . Make-Havells or equivalent in L&T/ABB/ Schneider, complete all as specified and directed by Engr-in-Charge. | 2 | Each | 52,000 ₹1,04,000 Lowest | 75,000 ₹1,50,000 | 73,000 ₹1,46,000 | 78,000 ₹1,56,000 |
| 4.00 | Description all as per serial item No 3.00 here-in- before but of size 75 HP, complete all as specified and directed by Engr-in-Charge | 3 | Each | 37,000 ₹1,11,000 Lowest | 65,000 ₹1,95,000 | 57,000 ₹1,71,000 | 48,000 ₹1,44,000 |
| 5.00 | Description all as per serial item No 3.00 here-in- before but of size 60 HP, complete all as specified and directed by Engr-in-Charge | 2 | Each | 30,000 ₹60,000 Lowest | 55,000 ₹1,10,000 | 42,000 ₹84,000 | 35,000 ₹70,000 |
| 6.00 | Description all as per serial item No 3.00 here-in- before but of size 50 HP, complete all as specified and directed by Engr-in-Charge | 3 | Each | 27,500 ₹82,500 | 55,000 ₹1,65,000 | 30,000 ₹90,000 | 25,000 ₹75,000 Lowest |
| 7.00 | Description all as per serial item No 3.00 here-in- before but of size 30 HP, complete all as specified and directed by Engr-in-Charge | 3 | Each | 13,000 ₹39,000 | 45,000 ₹1,35,000 | 22,000 ₹66,000 | 12,000 ₹36,000 Lowest |
| 8.00 | Description all as per serial item No 3.00 here-in- before but of size 20 HP, complete all as specified and directed by Engr-in-Charge | 2 | Each | 9,000 ₹18,000 Lowest | 28,000 ₹56,000 | 19,000 ₹38,000 | 9,000 ₹18,000 Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
8 Jul 2025, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur, Po-Garhi, Pin-182121
Repair/Maintenance of starter and control panels for pumping system in AOR of GE (U) Udhampur
2025_MES_713503_1
GE/U-34/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹98,000
22 Aug 2025
10 Jun 2025
10 Jul 2025
10 Jun 2025
8 Jul 2025
24 Jun 2025
Amount
M&L for Lt control panel designing, fabrication, providing,installation,testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. The panel shall be dust and vermin proof fabricated out of 14/16 SWG CR Sheet supported on M.S angle of suitable size and provision for erection/ fixing it on the ground/wall.The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should have equipped with following components, complete all as specified and directed by Engr-in-Charge :-
M&L for Lt control panel designing,fabrication,providing,installation,testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. The panel shall be dust and vermin proof fabricated out of 14/16 SWG CR Sheet supported on M.S angle of suitable size and provision for erection/ fixing it on the ground/wall.The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should have equipped with following components, complete all as specified and directed by Engr-in-Charge :-
Supply , fixing, commissining and testing in replacement of Fully automatic star delta motor starter in sheet steel enclosure type HGS series with single phase protection feature motor rating AC 3 phase 415 volts, 50 Hz for motor of capacity 100 HP . Make-Havells or equivalent in L&T/ABB/ Schneider, complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 3.00 here-in- before but of size 75 HP, complete all as specified and directed by Engr-in-Charge
Description all as per serial item No 3.00 here-in- before but of size 60 HP, complete all as specified and directed by Engr-in-Charge
Description all as per serial item No 3.00 here-in- before but of size 50 HP, complete all as specified and directed by Engr-in-Charge
Description all as per serial item No 3.00 here-in- before but of size 30 HP, complete all as specified and directed by Engr-in-Charge
Description all as per serial item No 3.00 here-in- before but of size 20 HP, complete all as specified and directed by Engr-in-Charge
Description all as per serial item No 3.00 here-in- before but of size 15 HP, complete all as specified and directed by Engr-in-Charge
S&F in replacement of DOL starter in sheet steel enclosure type for 1 to7.5 HP, complete all as specified and directed by Engr-in-Charge Make-Havells or equivalent in L&T/Indo Asian
M&L to repair soft starter of cap 270/250 HP mptor including replacement of master card,relay and other connected items for smooth functioning of starter repair should be carried out by the authorised dealer of soft starter and certificate will be provided by the cont from the dealer of soft starter, complete all as specified and directed by Engr-in-Charge
M&L to repair star delta starter of cap 100 HP motor including replacement of contactor,relay and other connected items for smooth functioning of starter repair should be carried out by the authorised dealer of star delta starter and certificate will be provided by the cont from the dealer of soft starter, complete all as specified and directed by Engr-in-Charge
M&L to repair star delta starter of cap 75 HP motor including replacement of contactor,relay and other connected items for smooth functioning of starter repair should be carried out by the authorised dealer of star delta starter and certificate will be provided by the cont from the dealer of soft starter, complete all as specified and directed by Engr-in-Charge
M&L to repair star delta starter of cap 50 HP motor including replacement of contactor,relay and other connected items for smooth functioning of starter repair should be carried out by the authorised dealer of star delta starter and certificate will be provided by the cont from the dealer of soft starter, complete all as specified and directed by Engr-in-Charge
Supply and laying DWC (Double wall corruguated) pipe 77/63 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing, complete all as specified and directed by Engr-in-Charge
Supply and laying DWC (Double wall corruguated) pipe 90/63 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing, complete all as specified and directed by Engr-in-charge
M&L in replacement of PVC insulated heavy duty industrial cables single core copper conductor(flexible) PVC insulated cable 1100 volt nominal area of conductor 185 sqmm inculding taking down existing old unserviceable cable of complete all as specified and directed by Engr-in-Charge
Description all as per serial item No 17.00 here-in- before but of size 120 sqmm, complete all as specified and directed by Engr-in-Charge
Description all as per serial item No 17.00 here-in- before but of size 50 sqmm, complete all as specified and directed by Engr-in-Charge
Description all as per serial item No 17.00 here-in- before but of size 30 sqmm, complete all as specified and directed by Engr-in-Charge
S&F in replacement of power contactor 4 pole with AC coil AC-3 duty rating at 415 Volts 50 Hz, frame size1 suitable for 270 HP centrifugal pump set as per Havells cat part No. IHPAC330400*, complete all as specified and directed by Engr-in-Charge
S&F in replacement of power contactor 4 pole with AC coil AC-3 duty rating at 415 Volts 50 Hz, frame size1 suitable for 170 HP centrifugal pump set as per Havells cat part No. IHPAC115100*, complete all as specified and directed by Engr-in-Charge
Excavation in trenches for Taking out / Laying HT/LT U/G Cable in any type of hard/ dense soil not exceeding 1.5 m wide and not exceeding 1.5m in depth and getting out, complete all as specified and directed by Engr-in-Charge.
M&L for dry sand cushioning to underground cable provided with layer of 8cms thick before laying the cable and 15cms thick after laying and stretching the cable and punned to 18 cm thick, complete all as specified and directed by Engr-in-Charge. Note: Only punned thickness shall be measured for payment purpose.
Supply and lay PCC cable cover class HV type 2 flat size 300 mm x 180 mm x 40 mm, complete all as specified and directed by Engr-in-Charge.
Returning, filling, levelling, spreading, watering and well ramming in layers not exc. 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing surplus soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing & testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 400 sqmm 3.5 core as laid in trenches, passing through pipes, ducts, complete all as specified and directed by Engr-in-Charge.
M/S DHARAM & SONS ENTERPRISES (BID ID -3351786)
DAVINDER SINGH (BID ID -3342597)
VIRINDER SINGH (BID ID -3343299)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .