| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-The Technical bid of M/s Hill Top Constructions is not in order as per NIT eligibility criteria. The EMD amount not as per the NIT requirement of Rs.6990/-. Hence, not admitted. |
Tender Value
₹3.5 L
EMD Value
₹6,990
Closing Date
9 Aug 2024, 6:00 pmClosed
THE EXECUTIVE ENGINEER CIVIL TENDER KTK CIRCLE
Room No 324 3rd Floor Office of CGMT Doorasamparka Bhavan No1 Swamy Vivekananda Road Bengaluru 560008
Maintenance and Repairs to BSNL Staff quarters at SQ campus Shettihalli Tumkur 2nd call
2024_BSNL_202948_1
05NITBSNLCDMYS202425
Open Tender
Civil Works - Buildings
Item Rate
60 days
TUMKUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL MYSORE TELECOM DISTRICT
₹6,990
13 Aug 2024
29 Jul 2024
12 Aug 2024
31 Jul 2024
9 Aug 2024
31 Jul 2024
31 Jul 2024 - 8 Aug 2024
Amount
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50
All kinds of soil.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto1.5 m.
All kinds of soil.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Sal wood
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing ISi marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete :
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Single rubber stopper
Providing and fixing to existing door frames.
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.
Marine plywood conforming to IS: 710
Taking out existing wooden door shutter, dismembering necessary styles, rails,panels and cutting/removing damaged parts of frame, panel etc. fixing of necessary new style, bottom rail, panel etc. And refixing of repaired door shutters to existing door frames, including replacement of hinges, required screws, nails & primer coat to new woodwork all complete as per the direction of the Engineer-in-charge.(Note:-New woodwork in frame & ply panels shall be paid separately.)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.
a) Single tee with door
b) Bend 87.5°
75 mm bend
110 mm bend
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:4 (1 cement: 4 fine sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
20 mm cement plaster
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand).
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Renewing glass panes, with wooden fillets wherever necessary:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10 litre capacity - White
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. A) Flexible pipe
40 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms.
Providing and fixing PVC trap of self cleansing design with top tile and strainer complete, including cost of cutting and making good the walls and floors :
100 mm inlet and 75 mm outlet
Providing and fixing on wall face unplasticised Rigid PVC (SWR grade) Soil, waste, vent pipes conforming to IS : 13592 Type A, including jointing with seal ring IS : 5382, leaving 10 mm gap for thermal expansion,conforming to IS : 13592: Single socketed pipes.
75 mm diametre
100 mm diametre
Cleaning of manholes by removing deposited silt and other waste material from drainage manholes and sewer lines including rodding and flushing with water as directed.(Rate is per one manhole and sewer line upto next manhole)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia. Pipes.
32 mm nominal outer dia. Pipes.
40 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work
32 mm nominal outer dia. Pipes.
40 mm nominal outer dia. Pipes.
50 mm nominal outer dia. Pipes.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal outer dia. Pipes.
32 mm nominal outer dia. Pipes.
40 mm nominal outer dia. Pipes.
Providing and fixing CPVC unions for CPVC pipe line including cutting and fixing.
40 mm dia
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT bib cock of approved quality and colour.
15 mm nominal bore, 122 mm long. Weighing not less than 99 gms.
Providing and fixing PTMT stop cock of approved quality and colour.
15 mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour .
15mm nominal bore, 125 mm long foam flow. Weighing not less than 120 gms.
Providing and fixing Stainless Steel grating 0.60mm thick grating for floor traps complete as directed.
100mm dia Circular
Providing and fixing PTMT swivelling shower, 15mm nominal bore. Weighing not less than 40 gms.
Providing and fixing uplasticised PVC connection pipe with brass unions : a) 45 cm length
15 mm nominal bore
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.
25mm nominal bore. Weighing not less than 62 gms.
Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)including disposal of malba.
Removing and refixing of wash basin for maintenance and repair works including fixing with new brackets, screws etc. complete as per the direction of Engineer-in-charge.
Removing grownup bush/any type of vegetation on building walls( at all Level ) / terraces including dismantling plaster, cutting bush, burning stem with acid or tar and patch plastering at all levels.
Cleaning of terrace/spouts/khurras/ anopy/Blocked Chajjas etc, by Removing leaves, grass,dust,Rubbish and other deposited/accumulated Materials etc including disposal of Rubbish to dumping ground up to a distance of 50m outside the periphery of building etc. cleaning of Terraces, accessible canopy ,chajjas & likes etc. complete as per the direction of the Engineer-in- charge
Filling cracks by making grove & using 'Dr. Fixit Crack - X powder or equivalent polymer crack filling material etc. complete and as per direction of Engineer-in-charge
Repairs to PVC flushing cistern of 5 to 10 Ltr capacity of any make and size including replacing defective part like ball valve, flushing knob etc. wherever required. Rate inclusive of all materials and labours only.
Cutting of tree branches in all floors and all heights mechanically with cutting mechine including stacking of wood pieces with in 50M lead etc complete as directed by the engineer in charge.
Easening of wooden doors/windows of any size and thickness by removing the doors /windows shutters making necessary repairs like plaining the edges as required so as to ensure smooth functional operation of the door/window and replacing the M.S.butt hinges wherever required etc,. all complete as directed by the Engineer-in-charge.
Door shutter
Window shutter
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .