CE OP Metro Zone
Mint Compound, Hyderabad
Bifurcation of 11KV Post Office Feeder emanating from 33/11KV HPS SS by erection of 1 No new 11KV outdoor breaker in the 33/11KV HPS SS, which includes laying of 1.4 KM of 11KV 3X300 Sq.mm of XLPE UG cable (Double run in Begumpet Section of Greenlands Sub-division of Greenlands Division and the work executed by the Construction wing of Banjara Hills division of Banjara Hills Circle under T and D Improvement works under General Category
738173
Chief Engineer/Operation/Metro Zone/TGSPDCL:eMZ-25/26-27
OPEN
Electrical Works
HYDERABAD, TELANGANA
1 document required · 1 mandatory
₹1,008
₹56,914
29 Sept 2026
29 Sept 2026
29 Sept 2026
Erection of pole in position, aligning and setting to work, fixing of cross arms and top clamps, earthing of supports, back filling with earth and stones properly ramming including transport of materials from road side to location excluding pit excavation, for RS Joist, Rail poles Supply & Fabrication of bottom plate with 6mm thichness and for Box poles Supply & Fabrication of Top & Bottom plate with 6mm thichness , Box pole 9/10/11 Mtr
Erection of pole in position, aligning and setting to work, fixing of cross arms and top clamps, earthing of supports, back filling with earth and stones properly ramming including transport of materials from road side to location excluding pit excavation, for RS Joist, Rail poles Supply & Fabrication of bottom plate with 6mm thichness and for Box poles Supply & Fabrication of Top & Bottom plate with 6mm thichness
Mass concreting of supports erected with CC (1:4:8) using 40 mm, HB G metal including the cost of metal, sand, Cement and curing etc.
Loading of R.S. Joists 175 x 85 mm
Un loading of R.S. Joists 175 x 85 mm
Fabrication of 175x85/150x75mm RS joist pieces upto 12.5 meters length by welding joint together by means of 50x6mm flat and MS channel on either side including the cost of consumable, Painting of RS Joist on inner phasing with red Oxide before Joining as box pole
Painting of R.S Joist,Box poles including cross arms and clamps with two coat of Al.paint including cost of paint and consumables.
Laying of XLPE UG cable including excavation of trench of size 450mm wide and 850mm for LT, 1050mm for 11 KV and 1200mm for 33 KV form road level, providing of DWC/GI pipes whereever required depth is not acquired as per the instructions of Engineer in Charge, the prorata basis rates to be adopted for 2 feet, 3feet depths and filling with sand 250mm above the cable and 50mm below the cable, laying of cable, placing 40mm shabad protective slabs, back filling the trench with earth, levelling and and removing the debris from the site inluding the cost of lead and lift etc.depth of the trench) LT -0.85 mts, 11 KV-1.05Mtrs & 33 KV - 1.20 mtrs, 11 KV 3x300 Sqmm Cable
Raising of cable on already erected support with wooden / MS clamps and connecting it to over head line with cable jumpers including cost of required wooden cleats, lugs and bolts and nuts through GI pipe (excluding the cost of GI pipe), 11 KV 3x300 Sqmm Cable
Making 11 KV 3x300 Sqmm Cable Out Door/Indoor end termination
Erection of 11KV 800A double throw AB Switches
Loading of 33KV 800 Amps AB Switch
Un loading of 33KV 800 Amps AB Switch
Erection of 11KV 400/200A Conventional type AB Switch including fixing of cross angles and alignment complete
Loading of 11KV AB Switch Conventional type
Un loading of 11KV AB Switch Conventional type
Wirring, commissioning and testing of Outdoor Sub-station switchgear duly conducting the pre commissioning test as per relevent standards & issue of certificate by CEIG authorised testing Engineer
Erection of 11 KV VCB with Control Panel
Con of Plinth for 11kv VCB 1.8x1.8x0.75m
Erection of 11 KV LAS line type including earthing
Loading of 11 KV VCBs along with Panel boards
Un loading of 11 KV VCBs along with Panel boards
11 Mtrs PSCC Poles/ Box poles 0.75 M x 0.9 M x 1.95 M (1.31 cum)
Painting of operating rods of 33kV, 11kV AB switches with post office red colour (including cost of paint)
Making of coil earthing pole with 8mm GI wireNut&Bolts for AB Switch
Supply of earthing pipe with material, GI wire No 8
Painting of feeder name on support including cost of paint
Laying of 4 core/10 core 2.5 sq. mm.Copper control cable in aready excavation trench including cost of providing single compress glands at both ends .
Supply of CI earth pipe 100 mm dia, 2.75 mt long thickness 10mm with flange as per specication
Providing of earthing with excavation of earth pit (0.6 x0.6x2.4Mts.) duly filling with bentonite, earth , running of earth wire etc., complete, including cost of bentonite and excluding cost of RCC collar of size 0.75M dia x 0.5 M height
Running of GI eartn flat of size 25X3mm from all metallic parts of channels, AB Switch, HG fuse set, DTr neutral and LT Distribution box and inter Connection of earth pits etc complete
Supply of earthing pipe with materials, GI Flat 25X3 mm
Providing of RCC Collar guarding to the existing earth pits with damaged masonry including dismantling and removing of existing masonry and fixing the RCC collar of 0.60 M dia X 0.50 M height
Supply of GI Bolts & Nuts etc
Alluminum alloy Pad clamps minimum 15 mm Thickness, 75 mm Width 150 Mm Length conforming to IS:5561-1970, IS 617,IS 2633-1964, IS 1363-1967, IS1367-1961), Six bolted with hot dip galvanized bolts and double nuts with spring and flat washers of size M10 x 65 i.e(3/8" x 21/2 ") minimum weight of 900 gms to suit for Panther ACSR Conductor of pad size 75 X75 X 15mm for carrying 600 A current.
Back clamps with 50 x 6 mm MS Flat
Earth work excavation of in all soils except hard rock requiring blasting.
Hoisting of Insulators and hardware, stretching the conductor and stringing of 11 kV bus comprising of three phases with Twin Zebra/Panther conductor to a tension of 900kgs including fixing of spacer clamps.(Bus section of 3.5mt)
Connection of equipment to bus and or another equipment with single zebra/Panther conductor including measuring, cutting,clamping and hoisting of suspension insulator assembly to support the conductor wherever necessary.
Coping of 1.5'x1.5'x1 with 1:8 slope Using form boxes (0.031Cumt.)
Laying of earth mat including excavation of trenches of depth 600mm, welding, connecting to equipment and connecting lightning shield to earth mat and earthing of fence posts, drilling and connecting earth rods including connecting cast iron pipes with the following sizes of MS Flats /GI Flats. including fabrication, 75x 8mm MS Flat / GI Flat.
Fabrication of Main and Auxiliary structures with welding using raw steel such as RS joist, M.S.Angles, Plates, Channels, including the supply and fabrication of 6mm base plate to the RS-Joist poles excluding cost of Mild Steel and transport charges to substation site, including erection.
Supply and Erection of Permanent Name Board of on 3'x4'steel sheetmounted on steel frame as described in Specification
Supply & spreading of 20mm machine crushed metal (HBG) including cost of conveneyance of all materials, labour charges etc complete for finished item of work and directed by the engineer incharge
Supply of U-Bolts 16 mm
Supply of Spacer T-Clamps with double dropper suitable for Zebra / Panther
Loading of M.S.Channels, Angles, Flats & Rods etc.,
Un loading of M.S.Channels, Angles, Flats & Rods etc.,
Transport of iron materials such as R.S. Joists, Rail Poles, fabricated supports, steel, iron, flat, M.S. Channels etc., by lorries. (excluding of loading & unloading ), TRANSPORT OF STEEL 10 TO 20KM
Transport of conductor drums, cable drums, fragile material such as kiosks, VCBs, control panels, Battery Chargers with Batteries, RMU, current transformers, boosters,lightning arrestors, insulators, transformers, meters (which are less in weight and occupy more space) (excluding of loading unloading), Transport of Cond Drum,VCBs upto 10Km
Hiring of Crane for 1st One Hour
Crane Charges over and above first hour
Cutting charges for MS Channel 100 x 50 mm
Erect-11KV Seating Channel
Fabrication of poles, 11KV Seating Channel
Erection of pole in position, aligning and setting to work, fixing of cross arms and top clamps, earthing of supports, back filling with earth and stones properly ramming including transport of materials from road side to location excluding pit excavation, for RS Joist, Rail poles Supply & Fabrication of bottom plate with 6mm thichness and for Box poles Supply & Fabrication of Top & Bottom plate with 6mm thichness, Box pole 9/10/11 Mtr
Loading of R.S. Joists 175 x 85 mm
Un loading of R.S. Joists 175 x 85 mm
Excavation of pits in hard rock requiring blasting. (other than SS), 11Mtrs PSCC Pole/ Box poles 0.75 M x 0.9 M x 1.95 M
Mass concreting of supports erected with CC (1:4:8) using 40 mm, HB G metal including the cost of metal, sand, Cement and curing etc.
Making 11 KV 3x300 Sqmm Cable Out Door/Indoor end termination
Making of Straight through joints, 11 KV 3x300 Sqmm Cable
Fabrication of 175x85/150x75mm RS joist pieces upto 12.5 meters length by welding joint together by means of 50x6mm flat and MS channel on either side including the cost of consumable, Painting of RS Joist on inner phasing with red Oxide before Joining as box pole
Along the CC / BT multi layer road requiring compressor, 11 KV 3x300 Sqmm Cable
Across the CC/ BT road crossing multi layer road requiring compressor (excluding the cost of Hume pipe) , 11 KV 3x300 Sqmm Cable
Across the CC/ BT road crossing multi layer road requiring compressor (excluding the cost of Hume pipe) Laying of 2nd Cable in Excavated Trench
Raising of double run cable on already erected support with wooden / MS clamps and connecting it to over head line with cable jumpers including cost of required wooden cleats, lugs and bolts and nuts through GI pipe (excluding the cost of GI pipe), 11 KV 3x300 Sqmm Cable
Supply of earthing pipe with materials, Supply of CI eath pipe with 80mm dia,2.0 M Length
Providing of earthing with excavation of earth pit (0.6 x0.6x2.4 Mts.) duly filling with bentonite, earth , running of earth wire etc., complete, including cost of bentonite and excluding cost of RCC collar of size 0.75M dia x 0.5 M height
Running of GI eartn flat of size 25X3mm from all metallic parts of channels, AB Switch, HG fuse set, DTr neutral and LT Distribution box and inter connection of earth pits etc complete
Supply of earthing pipe with materials, GI Flat 25X3 mm
Transport of iron materials such as R.S. Joists, Rail Poles, fabricated supports, steel, iron, flat, M.S. Channels etc., by lorries. (excluding of loading & unloading ) Above 10 KM and upto 20 KM
Back clamps with 50 x 6 mm MS Flat
Supply of 4" B Class GI Pipe 100 NB GI Pipe 4.50 mm thickness, 12.1 KG/Mtr
Loading of M.S.Channels, Angles, Flats & Rods etc.,
Un loading of M.S.Channels, Angles, Flats & Rods etc.,
Painting of feeder name on support including cost of paint
Loading of 11KV/33KV XLPE UG Cable for all sizes
Un loading of 11KV/33KV XLPE UG Cable for all sizes
Painting of R.S Joist,Box poles including cross arms and clamps with two coat of Al.paint including cost of paint and consumables.
Consultation charges for pursuing with various Departments for obtaining required permissions for Road cutting and submission of necessry Documents, Drawings etc.
Transport of conductor drums, cable drums, fragile material such as kiosks, VCBs, control panels, Battery Chargers with Batteries, RMU, current transformers, boosters, lightning arrestors, insulators, transformers, meters (which are less in weight and occupy more space) (excluding of loading unloading) Above 10 Km and upto 20 Km with Lorry for each trip
Excavatin of pit, Coping of 1.5'x1.5'x1 with 1:8 slope Using form boxes (0.031Cumt.)
Supply of RCC cable Joint markers/ Cable route markers of size 700 X 240 X 75 mm duly engraving with 5 mm thick letters , TGSPDCL 33000/11000 Cable/Cable joint fixing the 300mm below ground level and 400mm above ground level confirming to IS 5820 2001
Mass concreting of supports erected with CC (1:4:8) using 40 mm, HB G metal including the cost of metal, sand, Cement and curing etc.
supply of 4" DWC pipe
Including the cost of cement
Cutting charges for MS Channel 100 x 50 mm
Drilling of holes upto 20 mm dia using power drills,MS Channel, Angles and flat
"Providing of Base Concreting with 1:3:6 Concrete Mix including materials & curing with water
Erection of 11KV 400/200A Conventional type AB Switch including fixing of cross angles and alignment complete
Loading of 11KV AB Switch Conventional type
Un loading of 11KV AB Switch Conventional type
Making of coil earthing pole with 8mm GI wireNut&Bolts for AB Switch
Supply of earthing pipe with materials, GI wire No 8
Painting of operating rods of 33kV, 11kV AB switches with post office red colour (including cost of paint)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Bid - 11KV Post Office Feeder.doc
TENDER_DOCUMENT • 1.17 MB
BOQ.xls
TENDER_DOCUMENT • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .