Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Qualified | Qualified |
| 2 | Qualified | Qualified |
Tender Value
Refer Docs
EMD Value
₹5 Cr
Closing Date
21 Nov 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
KUMAR SIDDHANT DY MANAGER
Power Grid Corporation of India Limited Saudamini 3rd Floor Plot No 2 Sector 29 Gurgaon Haryana 122001
Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh.
CC/NT/W-TW/DOM/A06/23/07694
Open
Power/Energy Projects/Products
Works
LADAKH
₹5 Cr
23 Nov 2023
25 Aug 2023
23 Nov 2023
25 Aug 2023
21 Nov 2023
25 Aug 2023
1 Sept 2023
Package Name Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
Package Code Package: TL01 Bought-out
NIT/RFB No NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694
1 Fill up only green shaded cells in Schedule-1 and Schedule-2
2 All the cells in Schedule are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● Fill up applicable rate of Excise Duty. The amount of Excise Duty on the items mentioned as Direct in the mode of transaction in Schedule-1 shall be calculated automatically at the rate mentioned by the bidder here.
● Segregate and fill up the amount on which Sales Tax shall be applicable out of Ex-works supply items mentioned as direct in the mode of transaction in Schedule-1. Applicable Excise Duty on this amount will be calculated automatically at the rate mentioned by the bidder. Further, fill up the rate of applicable Sales Tax. Amount of Sales Tax shall be automatically calculated on the amount mentioned by the bidder as subjected to Sales Tax plus applicable Excise Duty at the rate mentioned by the Bidder.
● Difference of total amount quoted by the bidder as Direct Transaction and the amount mentioned by him subjected to Sales Tax shall be considered as the amount on which VAT shall become applicable and the same shall be calculated & displayed automatically. Applicable Excise Duty on this amount at the rate mentioned by the bidder shall also be calculated & displayed automatically. Fill up the rate of applicable VAT. The amount of VAT shall be calculated automatically on the amount considered to be subjected to VAT plus applicable Excise Duty at the rate mentioned by the bidder here.
● Amount as per details filled up by the bidder in the work sheets Entry Tax, Octroi and other Taxes & Duties shall be displayed in this work sheet Sch-5 but will not be added to the grand total and shall be considered as applicable.
● Click at the links to go to the work sheets Entry Tax, Octroi and other Taxes & Duties one by one.
● Fill the description, amount and rate of applicable Entry Tax. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Fill the description, amount and rate of applicable Octroi. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
Other Taxes & Duties :
● Fill the description, amount and rate of applicable Other Taxes & Duties. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid form 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694 Sole Bidder 1
JV (Joint Venture) Other Partner
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 1 0
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694 Schedule-1
Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED, 0
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon 0
Address : JOINT VENTURE OF 0 & 0
Supply of Plant (including Mandatory Spare Parts)
(All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Description Material Code GST payable on the price quoted if Contract is awarded (%) Description of Goods Unit Qty. Unit Ex- works price Total Ex-Works Price (excluding GST) Unit Price for inland transportation and other services required in India to convey the Goods to their final destination Total Price for inland transportation and other services required in India to convey the Goods to their final destination (excluding GST) GST payable on the price quoted if Contract is awarded Total Price per line item #REF!
Transmission Line Package TL01 GST on Ex works GST on F&I Total Ex works (exc GST) Total F&I (exc GST) Rounded off UnitPrice Total Corrected Price (excl. GST) GST rate GST @12% GST @18% GST @28% GST amount @12% GST amount @18% GST amount @28%
TL01 Pkg for 66kV Tangste-Phobrang 0 0 0.00 0.00 0 #REF! 0.00 0.00 #REF! 0.00 0.00 0.00 #REF! #REF! #REF! #REF! #REF! #REF! #REF!
1 7000024508 1130 STUB FAB SUPPLY 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 284 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
2 7000024508 1140 STUB FAB SUPPLY 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 378 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
3 7000024508 1150 STUB FAB SUPPLY 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 229 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
4 7000024508 1160 STUB FAB SUPPLY 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 205 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
5 7000024508 1170 STUB FAB SUPPLY 1000069039 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 4 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
6 7000024508 1180 STUB FAB SUPPLY 1000069040 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
7 7000024508 1190 STUB FAB SUPPLY 1000069041 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
8 7000024508 1200 STUB FAB SUPPLY 1000069043 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
9 7000024508 1210 STUB FAB SUPPLY 1000069044 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
10 7000024508 1220 STUB FAB SUPPLY 1000069045 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
11 7000024508 1230 EARTHING OF TOWERS 1000019718 18 Supply of Shieldwire EarthingincludingPG clamps, downlead clampsbutexcluding Earthwire bits for Pipetypeearthing EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
12 7000024508 1240 EARTHING OF TOWERS 1000045873 18 PIPE TYPE CHEMICAL EARTHING EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
13 7000024508 1250 EARTHING OF TOWERS 1000017587 18 Supply of Pipe Type Earthing EA 25 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
14 7000024508 1260 EARTHING OF TOWERS 1000057380 18 Supply of Shieldwire Earthing Counterpoise (4X30M) Type including PGclamps, downlead clamps but excluding Earthwire bits. EA 8 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
15 7000024508 1270 EARTHING OF TOWERS 1000048808 18 SUPPLY OF CHEMICAL EARTHING: COUNTERPOISE TYPE (120M LENGTH) EA 25 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
16 7000024508 1280 EARTHING OF TOWERS 1000010003 18 Supply of Counterpoise type (120 mlength) EA 224 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
17 7000024508 1290 EARTHING OF TOWERS 1000038340 18 ROD TYPE EARTHING EA 28 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
18 7000024508 1300 TOWER ACCESSORIES 1000017508 18 Phase Plate (Set of three) SET 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
19 7000024508 1310 TOWER ACCESSORIES 1000009119 18 Circuit Plate (Set of two) SET 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
20 7000024508 1320 TOWER ACCESSORIES 1000006779 18 Supply of Anti-Climbing Devices ofBarbedWire Type SET 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
21 7000024508 1330 TOWER ACCESSORIES 1000032563 18 DANGER PLATE FOR 66 KV EA 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
22 7000024508 1340 TOWER ACCESSORIES 1000034828 18 NUMBER PLATE FOR 66 KV TOWER EA 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
23 7000024508 1350 TOWER ACCESSORIES 1000007735 18 Bird Guard (Set of Three) SET 71 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
24 7000024508 1360 CONDUCTOR & Earthwire 1000030861 18 ACSR PANTHER CONDUCTOR KM 137 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
25 7000024508 1370 CONDUCTOR & Earthwire 1000030840 18 7/3.15 G.S. EARTHWIRE KM 46 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
26 7000024508 1380 INSULATOR 1000006183 18 90 KN AC Disc Insulator EA 27464 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
27 7000024508 1390 INSULATOR 1000005023 18 70 KN AC Disc Insulator EA 2151 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
28 7000024508 1400 HARDWARE FITTINGS 1000062512 18 HARDWARE FITTINGS FOR 66KV AC WITH ACSR PANTHERCONDUCTOR-DOUBLETENSION STRING SET 1236 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
29 7000024508 1410 HARDWARE FITTINGS 1000069346 18 HARDWARE FITTINGS FOR 66KV WITH SINGLE ACSR PANTHER-SINGLESUSPENSIONSTRING SET 213 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
30 7000024508 1420 CONDUCTOR & Earthwire ACCESSORIES 1000020990 18 Tension clamp -7/3.15mm Earth Wire EA 419 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
31 7000024508 1430 CONDUCTOR & Earthwire ACCESSORIES 1000020446 18 Suspension clamp -7/3.15mm Earth Wire EA 72 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
32 7000024508 1440 CONDUCTOR & Earthwire ACCESSORIES 1000022419 18 Vibration damper -7/3.15mm Earth Wire EA 980 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
33 7000024508 1450 CONDUCTOR & Earthwire ACCESSORIES 1000015517 18 Mid Span Compression Joint -7/3.15mm Earth Wire EA 26 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
34 7000024508 1460 CONDUCTOR & Earthwire ACCESSORIES 1000034136 18 FLEXIBLE ALUMUNIUM BOND EA 483 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
35 7000024508 1470 CONDUCTOR & Earthwire ACCESSORIES 1000022432 18 Vibration Damper for Conductor-ACSR Panther EA 2910 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
36 7000024508 1480 CONDUCTOR & Earthwire ACCESSORIES 1000018444 18 Repair Sleeve for Conductor-ACSR Panther EA 26 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
37 7000024508 1490 CONDUCTOR & Earthwire ACCESSORIES 1000015514 18 Mid Span Compression Joint for Conductor-ACSR Panther EA 84 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
38 7000024508 1500 SUPPLY OF AVIATION 1000016663 18 Supply of Obstruction Lights (as perIS5613)-1 Medium Intensity + 2LowIntensity SET 14 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
39 7000024508 1510 SUPPLY OF AVIATION 1000016664 18 Supply of Obstruction Lights (as per IS5613)-1 Medium Intensity + 4 LowIntensity SET 7 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
40 7000024508 1520 SUPPLY OF AVIATION 1000019903 18 Supply of Span Marker for Aviation EA 28 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
41 7000024508 1530 FAB SUPPLY TOWERS 1000069070 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 50 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
42 7000024508 1540 FAB SUPPLY TOWERS 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
43 7000024508 1550 FAB SUPPLY TOWERS 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 22 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
44 7000024508 1560 FAB SUPPLY TOWERS 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
45 7000024508 1570 FAB SUPPLY TOWERS 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 116 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
46 7000024508 1580 FAB SUPPLY TOWERS 1000069065 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 62 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
47 7000024508 1590 FAB SUPPLY TOWERS 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
48 7000024508 1600 FAB SUPPLY TOWERS 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 22 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
49 7000024508 1610 FAB SUPPLY TOWERS 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 31 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
50 7000024508 1620 FAB SUPPLY TOWERS 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 108 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
51 7000024508 1630 FAB SUPPLY TOWERS 1000069060 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
52 7000024508 1640 FAB SUPPLY TOWERS 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
53 7000024508 1650 FAB SUPPLY TOWERS 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 44 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
54 7000024508 1660 FAB SUPPLY TOWERS 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 45 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
55 7000024508 1670 FAB SUPPLY TOWERS 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 274 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
56 7000024508 1680 FAB SUPPLY TOWERS 1000069055 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 8 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
57 7000024508 1690 FAB SUPPLY TOWERS 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 100 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
58 7000024508 1700 FAB SUPPLY TOWERS 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 48 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
59 7000024508 1710 FAB SUPPLY TOWERS 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 60 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
60 7000024508 1720 FAB SUPPLY TOWERS 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 68 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
61 7000024508 1730 FAB SUPPLY TOWERS 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 52 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
62 7000024508 1740 FAB SUPPLY TOWERS 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 58 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
63 7000024508 1750 FAB SUPPLY TOWERS 1000069047 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 96 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
64 7000024508 1760 FAB SUPPLY TOWERS 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 71 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
Tl01 Pkg for 66kV Himya-Mudh Nyoma Part1
1 7000024508 380 STUB FAB SUPPLY 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 284 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
2 7000024508 390 STUB FAB SUPPLY 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 382 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
3 7000024508 400 STUB FAB SUPPLY 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 226 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
4 7000024508 410 STUB FAB SUPPLY 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 207 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
5 7000024508 420 STUB FAB SUPPLY 1000069039 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
6 7000024508 430 STUB FAB SUPPLY 1000069040 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
7 7000024508 440 STUB FAB SUPPLY 1000069041 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
8 7000024508 450 STUB FAB SUPPLY 1000069043 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
9 7000024508 460 STUB FAB SUPPLY 1000069044 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
10 7000024508 470 EARTHING OF TOWERS 1000019718 18 Supply of Shieldwire EarthingincludingPG clamps, downlead clampsbutexcluding Earthwire bits for Pipetypeearthing EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
11 7000024508 480 EARTHING OF TOWERS 1000045873 18 PIPE TYPE CHEMICAL EARTHING EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
12 7000024508 490 EARTHING OF TOWERS 1000017587 18 Supply of Pipe Type Earthing EA 25 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
13 7000024508 500 EARTHING OF TOWERS 1000057380 18 Supply of Shieldwire Earthing Counterpoise (4X30M) Type including PGclamps, downlead clamps but excluding Earthwire bits. EA 6 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
14 7000024508 510 EARTHING OF TOWERS 1000048808 18 SUPPLY OF CHEMICAL EARTHING: COUNTERPOISE TYPE (120M LENGTH) EA 25 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
15 7000024508 520 EARTHING OF TOWERS 1000010003 18 Supply of Counterpoise type (120 mlength) EA 225 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
16 7000024508 530 EARTHING OF TOWERS 1000038340 18 ROD TYPE EARTHING EA 27 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
17 7000024508 540 TOWER ACCESSORIES 1000017508 18 Phase Plate (Set of three) SET 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
18 7000024508 550 TOWER ACCESSORIES 1000009119 18 Circuit Plate (Set of two) SET 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
19 7000024508 560 TOWER ACCESSORIES 1000006779 18 Supply of Anti-Climbing Devices ofBarbedWire Type SET 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
20 7000024508 570 TOWER ACCESSORIES 1000032563 18 DANGER PLATE FOR 66 KV EA 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
21 7000024508 580 TOWER ACCESSORIES 1000034828 18 NUMBER PLATE FOR 66 KV TOWER EA 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
22 7000024508 590 TOWER ACCESSORIES 1000007735 18 Bird Guard (Set of Three) SET 71 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
23 7000024508 600 CONDUCTOR & Earthwire 1000030861 18 ACSR PANTHER CONDUCTOR KM 136 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
24 7000024508 610 CONDUCTOR & Earthwire 1000030840 18 7/3.15 G.S. EARTHWIRE KM 46 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
25 7000024508 620 INSULATOR 1000006183 18 90 KN AC Disc Insulator EA 27408 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
26 7000024508 630 INSULATOR 1000005023 18 70 KN AC Disc Insulator EA 2153 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
27 7000024508 640 HARDWARE FITTINGS 1000062512 18 HARDWARE FITTINGS FOR 66KV AC WITH ACSR PANTHERCONDUCTOR-DOUBLETENSION STRING SET 1233 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
28 7000024508 650 HARDWARE FITTINGS 1000069346 18 HARDWARE FITTINGS FOR 66KV WITH SINGLE ACSR PANTHER-SINGLESUSPENSIONSTRING SET 213 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
29 7000024508 660 CONDUCTOR & Earthwire ACCESSORIES 1000020990 18 Tension clamp -7/3.15mm Earth Wire EA 416 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
30 7000024508 670 CONDUCTOR & Earthwire ACCESSORIES 1000020446 18 Suspension clamp -7/3.15mm Earth Wire EA 72 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
31 7000024508 680 CONDUCTOR & Earthwire ACCESSORIES 1000022419 18 Vibration damper -7/3.15mm Earth Wire EA 1225 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
32 7000024508 690 CONDUCTOR & Earthwire ACCESSORIES 1000015517 18 Mid Span Compression Joint -7/3.15mm Earth Wire EA 26 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
33 7000024508 700 CONDUCTOR & Earthwire ACCESSORIES 1000034136 18 FLEXIBLE ALUMUNIUM BOND EA 482 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
34 7000024508 710 CONDUCTOR & Earthwire ACCESSORIES 1000022432 18 Vibration Damper for Conductor-ACSR Panther EA 2899 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
35 7000024508 720 CONDUCTOR & Earthwire ACCESSORIES 1000018444 18 Repair Sleeve for Conductor-ACSR Panther EA 25 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
36 7000024508 730 CONDUCTOR & Earthwire ACCESSORIES 1000015514 18 Mid Span Compression Joint for Conductor-ACSR Panther EA 83 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
37 7000024508 740 SUPPLY OF AVIATION 1000016663 18 Supply of Obstruction Lights (as perIS5613)-1 Medium Intensity + 2LowIntensity SET 14 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
38 7000024508 750 SUPPLY OF AVIATION 1000016664 18 Supply of Obstruction Lights (as per IS5613)-1 Medium Intensity + 4 LowIntensity SET 7 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
39 7000024508 760 SUPPLY OF AVIATION 1000019903 18 Supply of Span Marker for Aviation EA 27 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
40 7000024508 770 FAB SUPPLY TOWERS 1000069070 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 51 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
41 7000024508 780 FAB SUPPLY TOWERS 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
42 7000024508 790 FAB SUPPLY TOWERS 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
43 7000024508 800 FAB SUPPLY TOWERS 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
44 7000024508 810 FAB SUPPLY TOWERS 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 115 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
45 7000024508 820 FAB SUPPLY TOWERS 1000069065 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 61 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
46 7000024508 830 FAB SUPPLY TOWERS 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
47 7000024508 840 FAB SUPPLY TOWERS 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
48 7000024508 850 FAB SUPPLY TOWERS 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 31 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
49 7000024508 860 FAB SUPPLY TOWERS 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 106 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
50 7000024508 870 FAB SUPPLY TOWERS 1000069060 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
51 7000024508 880 FAB SUPPLY TOWERS 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
52 7000024508 890 FAB SUPPLY TOWERS 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 42 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
53 7000024508 900 FAB SUPPLY TOWERS 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 43 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
54 7000024508 910 FAB SUPPLY TOWERS 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
55 7000024508 920 FAB SUPPLY TOWERS 1000069055 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
56 7000024508 930 FAB SUPPLY TOWERS 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 99 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
57 7000024508 940 FAB SUPPLY TOWERS 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 49 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
58 7000024508 950 FAB SUPPLY TOWERS 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 59 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
59 7000024508 960 FAB SUPPLY TOWERS 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 68 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
60 7000024508 970 FAB SUPPLY TOWERS 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 52 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
61 7000024508 980 FAB SUPPLY TOWERS 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 57 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
62 7000024508 990 FAB SUPPLY TOWERS 1000069047 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 96 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
63 7000024508 1000 FAB SUPPLY TOWERS 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 71 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
Tl01 Package for 66 kV Kharu-Tangste 0 0 0.00 0.00 0 #REF! 0.00 0.00 #REF! 0.00 0.00 0.00 #REF! #REF! #REF! #REF! #REF! #REF! #REF!
1 7000024508 2650 STUB FAB SUPPLY 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 444 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
2 7000024508 2660 STUB FAB SUPPLY 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 587 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
3 7000024508 2670 STUB FAB SUPPLY 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 353 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
4 7000024508 2680 STUB FAB SUPPLY 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 330 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
5 7000024508 2690 STUB FAB SUPPLY 1000069039 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 4 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
6 7000024508 2700 STUB FAB SUPPLY 1000069040 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
7 7000024508 2710 STUB FAB SUPPLY 1000069041 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
8 7000024508 2720 STUB FAB SUPPLY 1000069043 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
9 7000024508 2730 STUB FAB SUPPLY 1000069044 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
10 7000024508 2740 STUB FAB SUPPLY 1000069045 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
11 7000024508 2750 EARTHING OF TOWERS 1000019718 18 Supply of Shieldwire EarthingincludingPG clamps, downlead clampsbutexcluding Earthwire bits for Pipetypeearthing EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
12 7000024508 2760 EARTHING OF TOWERS 1000045873 18 PIPE TYPE CHEMICAL EARTHING EA 4 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
13 7000024508 2770 EARTHING OF TOWERS 1000017587 18 Supply of Pipe Type Earthing EA 39 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
14 7000024508 2780 EARTHING OF TOWERS 1000057380 18 Supply of Shieldwire Earthing Counterpoise (4X30M) Type including PGclamps, downlead clamps but excluding Earthwire bits. EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
15 7000024508 2790 EARTHING OF TOWERS 1000048808 18 SUPPLY OF CHEMICAL EARTHING: COUNTERPOISE TYPE (120M LENGTH) EA 39 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
16 7000024508 2800 EARTHING OF TOWERS 1000010003 18 Supply of Counterpoise type (120 mlength) EA 349 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
17 7000024508 2810 EARTHING OF TOWERS 1000038340 18 ROD TYPE EARTHING EA 43 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
18 7000024508 2820 TOWER ACCESSORIES 1000017508 18 Phase Plate (Set of three) SET 431 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
19 7000024508 2830 TOWER ACCESSORIES 1000009119 18 Circuit Plate (Set of two) SET 431 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
20 7000024508 2840 TOWER ACCESSORIES 1000006779 18 Supply of Anti-Climbing Devices ofBarbedWire Type SET 431 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
21 7000024508 2850 TOWER ACCESSORIES 1000032563 18 DANGER PLATE FOR 66 KV EA 431 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
22 7000024508 2860 TOWER ACCESSORIES 1000034828 18 NUMBER PLATE FOR 66 KV TOWER EA 431 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
23 7000024508 2870 TOWER ACCESSORIES 1000007735 18 Bird Guard (Set of Three) SET 111 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
24 7000024508 2880 CONDUCTOR & Earthwire 1000030861 18 ACSR PANTHER CONDUCTOR KM 213 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
28 7000024508 2920 HARDWARE FITTINGS 1000062512 18 HARDWARE FITTINGS FOR 66KV AC WITH ACSR PANTHERCONDUCTOR-DOUBLETENSION STRING SET 1920 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
29 7000024508 10 HARDWARE FITTINGS 1000069346 18 HARDWARE FITTINGS FOR 66KV WITH SINGLE ACSR PANTHER-SINGLESUSPENSIONSTRING SET 333 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
30 7000024508 2930 CONDUCTOR & Earthwire ACCESSORIES 1000020990 18 Tension clamp -7/3.15mm Earth Wire EA 649 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
31 7000024508 2940 CONDUCTOR & Earthwire ACCESSORIES 1000020446 18 Suspension clamp -7/3.15mm Earth Wire EA 113 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
32 7000024508 2950 CONDUCTOR & Earthwire ACCESSORIES 1000022419 18 Vibration damper -7/3.15mm Earth Wire EA 1522 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
33 7000024508 2960 CONDUCTOR & Earthwire ACCESSORIES 1000015517 18 Mid Span Compression Joint -7/3.15mm Earth Wire EA 40 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
34 7000024508 2970 CONDUCTOR & Earthwire ACCESSORIES 1000034136 18 FLEXIBLE ALUMUNIUM BOND EA 751 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
35 7000024508 2980 CONDUCTOR & Earthwire ACCESSORIES 1000022432 18 Vibration Damper for Conductor-ACSR Panther EA 4518 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
36 7000024508 2990 CONDUCTOR & Earthwire ACCESSORIES 1000018444 18 Repair Sleeve for Conductor-ACSR Panther EA 40 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
37 7000024508 3000 CONDUCTOR & Earthwire ACCESSORIES 1000015514 18 Mid Span Compression Joint for Conductor-ACSR Panther EA 131 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
38 7000024508 3010 SUPPLY OF AVIATION 1000016663 18 Supply of Obstruction Lights (as perIS5613)-1 Medium Intensity + 2LowIntensity SET 22 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
39 7000024508 3020 SUPPLY OF AVIATION 1000016664 18 Supply of Obstruction Lights (as per IS5613)-1 Medium Intensity + 4 LowIntensity SET 11 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
40 7000024508 3030 SUPPLY OF AVIATION 1000019903 18 Supply of Span Marker for Aviation EA 43 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
41 7000024508 3040 FAB SUPPLY TOWERS 1000069070 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 78 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
42 7000024508 3050 FAB SUPPLY TOWERS 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
43 7000024508 3060 FAB SUPPLY TOWERS 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 35 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
44 7000024508 3070 FAB SUPPLY TOWERS 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 20 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
45 7000024508 3080 FAB SUPPLY TOWERS 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 181 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
46 7000024508 3090 FAB SUPPLY TOWERS 1000069065 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 94 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
47 7000024508 3100 FAB SUPPLY TOWERS 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
48 7000024508 3110 FAB SUPPLY TOWERS 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 35 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
49 7000024508 3120 FAB SUPPLY TOWERS 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 44 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
50 7000024508 3130 FAB SUPPLY TOWERS 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 165 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
51 7000024508 3140 FAB SUPPLY TOWERS 1000069060 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 20 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
52 7000024508 3150 FAB SUPPLY TOWERS 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 19 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
53 7000024508 3160 FAB SUPPLY TOWERS 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 62 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
54 7000024508 3170 FAB SUPPLY TOWERS 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 63 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
55 7000024508 3180 FAB SUPPLY TOWERS 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 428 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
56 7000024508 3190 FAB SUPPLY TOWERS 1000069055 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 16 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
57 7000024508 3200 FAB SUPPLY TOWERS 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 152 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
58 7000024508 3210 FAB SUPPLY TOWERS 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 76 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
59 7000024508 3220 FAB SUPPLY TOWERS 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 92 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
60 7000024508 3230 FAB SUPPLY TOWERS 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 108 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
61 7000024508 3240 FAB SUPPLY TOWERS 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 83 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
62 7000024508 3250 FAB SUPPLY TOWERS 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 89 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
63 7000024508 3260 FAB SUPPLY TOWERS 1000069047 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 148 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
64 7000024508 3270 FAB SUPPLY TOWERS 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 111 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
65 7000024508 140 TOWER STUB EXTENSION 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
66 7000024508 150 TOWER STUB EXTENSION 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
67 7000024508 160 TOWER STUB EXTENSION 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
68 7000024508 170 TOWER STUB EXTENSION 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
69 7000024508 180 TOWER STUB EXTENSION 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
70 7000024508 190 TOWER STUB EXTENSION 1000069047 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
71 7000024508 200 TOWER STUB EXTENSION 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
72 7000024508 210 TOWER STUB EXTENSION 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
73 7000024508 220 TOWER STUB EXTENSION 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
74 7000024508 230 TOWER STUB EXTENSION 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
75 7000024508 240 TOWER STUB EXTENSION 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 6 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
76 7000024508 250 TOWER STUB EXTENSION 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
77 7000024508 260 TOWER STUB EXTENSION 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
78 7000024508 270 TOWER STUB EXTENSION 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
79 7000024508 280 TOWER STUB EXTENSION 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
80 7000024508 290 TOWER STUB EXTENSION 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
81 7000024508 300 TOWER STUB EXTENSION 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
82 7000024508 310 TOWER STUB EXTENSION 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
83 7000024508 320 TOWER STUB EXTENSION 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
84 7000024508 330 TOWER STUB EXTENSION 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
85 7000024508 340 TOWER STUB EXTENSION 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
86 7000024508 350 TOWER STUB EXTENSION 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
87 7000024508 360 TOWER STUB EXTENSION 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
88 7000024508 370 TOWER STUB EXTENSION 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
TL01 Pkg for 66kV Tangste-Chushul 0 0 0.00 0.00 0 #REF! 0.00 0.00 #REF! 0.00 0.00 0.00 #REF! #REF! #REF! #REF! #REF! #REF! #REF!
1 7000024508 1890 STUB FAB SUPPLY 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 508 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
2 7000024508 1900 STUB FAB SUPPLY 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 668 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
3 7000024508 1910 STUB FAB SUPPLY 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 404 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
4 7000024508 1920 STUB FAB SUPPLY 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 370 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
5 7000024508 1930 STUB FAB SUPPLY 1000069039 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
6 7000024508 1940 STUB FAB SUPPLY 1000069040 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
7 7000024508 1950 STUB FAB SUPPLY 1000069041 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
8 7000024508 1960 STUB FAB SUPPLY 1000069043 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
9 7000024508 1970 STUB FAB SUPPLY 1000069044 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
10 7000024508 1980 STUB FAB SUPPLY 1000069045 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
11 7000024508 1990 EARTHING OF TOWERS 1000019718 18 Supply of Shieldwire EarthingincludingPG clamps, downlead clampsbutexcluding Earthwire bits for Pipetypeearthing EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
12 7000024508 2000 EARTHING OF TOWERS 1000045873 18 PIPE TYPE CHEMICAL EARTHING EA 5 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
13 7000024508 2010 EARTHING OF TOWERS 1000017587 18 Supply of Pipe Type Earthing EA 44 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
14 7000024508 2020 EARTHING OF TOWERS 1000057380 18 Supply of Shieldwire Earthing Counterpoise (4X30M) Type including PGclamps, downlead clamps but excluding Earthwire bits. EA 11 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
15 7000024508 2030 EARTHING OF TOWERS 1000048808 18 SUPPLY OF CHEMICAL EARTHING: COUNTERPOISE TYPE (120M LENGTH) EA 44 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
16 7000024508 2040 EARTHING OF TOWERS 1000010003 18 Supply of Counterpoise type (120 mlength) EA 397 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
17 7000024508 2050 EARTHING OF TOWERS 1000038340 18 ROD TYPE EARTHING EA 49 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
18 7000024508 2060 TOWER ACCESSORIES 1000017508 18 Phase Plate (Set of three) SET 490 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
19 7000024508 2070 TOWER ACCESSORIES 1000009119 18 Circuit Plate (Set of two) SET 490 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
20 7000024508 2080 TOWER ACCESSORIES 1000006779 18 Supply of Anti-Climbing Devices ofBarbedWire Type SET 490 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
21 7000024508 2090 TOWER ACCESSORIES 1000032563 18 DANGER PLATE FOR 66 KV EA 490 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
22 7000024508 2100 TOWER ACCESSORIES 1000034828 18 NUMBER PLATE FOR 66 KV TOWER EA 490 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
23 7000024508 2110 TOWER ACCESSORIES 1000007735 18 Bird Guard (Set of Three) SET 127 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
24 7000024508 2120 CONDUCTOR & Earthwire 1000030861 18 ACSR PANTHER CONDUCTOR KM 243 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
25 7000024508 2130 CONDUCTOR & Earthwire 1000030840 18 7/3.15 G.S. EARTHWIRE KM 82 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
26 7000024508 2140 INSULATOR 1000006183 18 90 KN AC Disc Insulator EA 48395 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
27 7000024508 2150 INSULATOR 1000005023 18 70 KN AC Disc Insulator EA 3848 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
28 7000024508 2160 HARDWARE FITTINGS 1000062512 18 HARDWARE FITTINGS FOR 66KV AC WITH ACSR PANTHERCONDUCTOR-DOUBLETENSION STRING SET 2178 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
29 7000024508 2170 HARDWARE FITTINGS 1000069346 18 HARDWARE FITTINGS FOR 66KV WITH SINGLE ACSR PANTHER-SINGLESUSPENSIONSTRING SET 381 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
30 7000024508 2180 CONDUCTOR & Earthwire ACCESSORIES 1000020990 18 Tension clamp -7/3.15mm Earth Wire EA 736 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
31 7000024508 2190 CONDUCTOR & Earthwire ACCESSORIES 1000020446 18 Suspension clamp -7/3.15mm Earth Wire EA 129 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
32 7000024508 2200 CONDUCTOR & Earthwire ACCESSORIES 1000022419 18 Vibration damper -7/3.15mm Earth Wire EA 1728 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
33 7000024508 2210 CONDUCTOR & Earthwire ACCESSORIES 1000015517 18 Mid Span Compression Joint -7/3.15mm Earth Wire EA 46 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
34 7000024508 2220 CONDUCTOR & Earthwire ACCESSORIES 1000034136 18 FLEXIBLE ALUMUNIUM BOND EA 853 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
35 7000024508 2230 CONDUCTOR & Earthwire ACCESSORIES 1000022432 18 Vibration Damper for Conductor-ACSR Panther EA 5130 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
36 7000024508 2240 CONDUCTOR & Earthwire ACCESSORIES 1000018444 18 Repair Sleeve for Conductor-ACSR Panther EA 45 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
37 7000024508 2250 CONDUCTOR & Earthwire ACCESSORIES 1000015514 18 Mid Span Compression Joint for Conductor-ACSR Panther EA 149 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
38 7000024508 2260 SUPPLY OF AVIATION 1000016663 18 Supply of Obstruction Lights (as perIS5613)-1 Medium Intensity + 2LowIntensity SET 25 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
39 7000024508 2270 SUPPLY OF AVIATION 1000016664 18 Supply of Obstruction Lights (as per IS5613)-1 Medium Intensity + 4 LowIntensity SET 13 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
40 7000024508 2280 SUPPLY OF AVIATION 1000019903 18 Supply of Span Marker for Aviation EA 49 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
41 7000024508 2290 FAB SUPPLY TOWERS 1000069070 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 91 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
42 7000024508 2300 FAB SUPPLY TOWERS 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
43 7000024508 2310 FAB SUPPLY TOWERS 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 40 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
44 7000024508 2320 FAB SUPPLY TOWERS 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
45 7000024508 2330 FAB SUPPLY TOWERS 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 202 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
46 7000024508 2340 FAB SUPPLY TOWERS 1000069065 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 107 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
47 7000024508 2350 FAB SUPPLY TOWERS 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
48 7000024508 2360 FAB SUPPLY TOWERS 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 40 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
49 7000024508 2370 FAB SUPPLY TOWERS 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 53 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
50 7000024508 2380 FAB SUPPLY TOWERS 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 190 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
51 7000024508 2390 FAB SUPPLY TOWERS 1000069060 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
52 7000024508 2400 FAB SUPPLY TOWERS 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 19 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
53 7000024508 2410 FAB SUPPLY TOWERS 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 70 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
54 7000024508 2420 FAB SUPPLY TOWERS 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 72 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
55 7000024508 2430 FAB SUPPLY TOWERS 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 490 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
56 7000024508 2440 FAB SUPPLY TOWERS 1000069055 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 16 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
57 7000024508 2450 FAB SUPPLY TOWERS 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 176 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
58 7000024508 2460 FAB SUPPLY TOWERS 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 88 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
59 7000024508 2470 FAB SUPPLY TOWERS 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 104 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
60 7000024508 2480 FAB SUPPLY TOWERS 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 124 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
61 7000024508 2490 FAB SUPPLY TOWERS 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 93 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
62 7000024508 2500 FAB SUPPLY TOWERS 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 102 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
63 7000024508 2510 FAB SUPPLY TOWERS 1000069047 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 168 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
64 7000024508 2520 FAB SUPPLY TOWERS 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 127 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
Total Ex-Works Price 0.00 0.00 0.00 0.00 0.00 #REF! #REF! #REF! #REF!
Total Price for inland transportation and other services required in India to convey the Goods to their final destination (excluding GST) 0.00
GST payable on the price quoted if Contract is awarded 0.00 #REF! #REF! #REF! #REF!
Total Ex-Works Price including GST 0.00
Date Printed Name
Place Designation
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694 Schedule - 2
Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Supply of Installation Services :
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘8’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable (in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit price GST payable on the price quoted if Contract is awarded (%) Total Price per line item (excluding GST) GST payable on the price quoted if Contract is awarded (Amount) Total Price per line item (including GST) GST Before Discount Discount Total Price after discount GST After Discount
Transmission Line Package TL01 Rounded off UnitPrice Total Corrected Price (excl. GST) GST rate GST Amount
Tl01 Package for 66 kV Kharu-Tangste 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
1 7000024508 20 100 10 SURVEY 100001243 Check survey KM 70 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
2 7000024508 20 100 20 SURVEY 100001242 Detailed survey including route alignment, profiling and tower spotting KM 70 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
3 7000024508 30 110 10 SOIL INVESTIGATION 100001244 Detailed soil investigation: All kinds of soils except fissured rock and hard rock EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
4 7000024508 30 110 20 SOIL INVESTIGATION 100001245 Detailed soil investigation: Fissured Rock EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
5 7000024508 30 110 30 SOIL INVESTIGATION 100001246 Detailed soil investigation: Hard Rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
6 7000024508 40 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100044200 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
7 7000024508 40 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100044199 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
8 7000024508 40 120 120 WORK ASSOCIATED WITH TOWER FOUNDATION 100044221 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
9 7000024508 40 120 130 WORK ASSOCIATED WITH TOWER FOUNDATION 100044220 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 24 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
10 7000024508 40 120 140 WORK ASSOCIATED WITH TOWER FOUNDATION 100044219 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
11 7000024508 40 120 150 WORK ASSOCIATED WITH TOWER FOUNDATION 100044218 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
12 7000024508 40 120 160 WORK ASSOCIATED WITH TOWER FOUNDATION 100044217 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
13 7000024508 40 120 180 WORK ASSOCIATED WITH TOWER FOUNDATION 100044215 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
14 7000024508 40 120 190 WORK ASSOCIATED WITH TOWER FOUNDATION 100044214 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
15 7000024508 40 120 200 WORK ASSOCIATED WITH TOWER FOUNDATION 100044213 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
16 7000024508 40 120 210 WORK ASSOCIATED WITH TOWER FOUNDATION 100044212 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
17 7000024508 40 120 230 WORK ASSOCIATED WITH TOWER FOUNDATION 100044202 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
18 7000024508 40 120 250 WORK ASSOCIATED WITH TOWER FOUNDATION 100044204 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
19 7000024508 40 120 260 WORK ASSOCIATED WITH TOWER FOUNDATION 100044205 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
20 7000024508 40 120 280 WORK ASSOCIATED WITH TOWER FOUNDATION 100044207 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
21 7000024508 40 120 290 WORK ASSOCIATED WITH TOWER FOUNDATION 100044208 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
22 7000024508 40 120 310 WORK ASSOCIATED WITH TOWER FOUNDATION 100044262 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.). EA 444 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
23 7000024508 40 120 320 WORK ASSOCIATED WITH TOWER FOUNDATION 100044263 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 587 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
24 7000024508 40 120 330 WORK ASSOCIATED WITH TOWER FOUNDATION 100044264 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 353 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
25 7000024508 40 120 340 WORK ASSOCIATED WITH TOWER FOUNDATION 100044265 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 330 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
26 7000024508 40 120 360 WORK ASSOCIATED WITH TOWER FOUNDATION 100044255 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
27 7000024508 40 120 370 WORK ASSOCIATED WITH TOWER FOUNDATION 100044256 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
28 7000024508 40 120 380 WORK ASSOCIATED WITH TOWER FOUNDATION 100044257 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
29 7000024508 40 120 400 WORK ASSOCIATED WITH TOWER FOUNDATION 100044259 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
30 7000024508 40 120 410 WORK ASSOCIATED WITH TOWER FOUNDATION 100044260 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
31 7000024508 40 120 420 WORK ASSOCIATED WITH TOWER FOUNDATION 100044261 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
32 7000024508 40 120 440 WORK ASSOCIATED WITH TOWER FOUNDATION 100044179 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
33 7000024508 40 120 450 WORK ASSOCIATED WITH TOWER FOUNDATION 100044180 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
34 7000024508 40 120 460 WORK ASSOCIATED WITH TOWER FOUNDATION 100044181 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
35 7000024508 40 120 470 WORK ASSOCIATED WITH TOWER FOUNDATION 100044182 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 48 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
36 7000024508 40 120 480 WORK ASSOCIATED WITH TOWER FOUNDATION 100044183 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
37 7000024508 40 120 490 WORK ASSOCIATED WITH TOWER FOUNDATION 100044184 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
38 7000024508 40 120 500 WORK ASSOCIATED WITH TOWER FOUNDATION 100044185 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 24 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
39 7000024508 40 120 510 WORK ASSOCIATED WITH TOWER FOUNDATION 100044186 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
40 7000024508 40 120 530 WORK ASSOCIATED WITH TOWER FOUNDATION 100044188 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 24 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
41 7000024508 40 120 540 WORK ASSOCIATED WITH TOWER FOUNDATION 100044189 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
42 7000024508 40 120 570 WORK ASSOCIATED WITH TOWER FOUNDATION 100044192 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
43 7000024508 40 120 590 WORK ASSOCIATED WITH TOWER FOUNDATION 100044194 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
44 7000024508 40 120 610 WORK ASSOCIATED WITH TOWER FOUNDATION 100044196 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
45 7000024508 40 120 640 WORK ASSOCIATED WITH TOWER FOUNDATION 100044211 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
46 7000024508 40 120 660 WORK ASSOCIATED WITH TOWER FOUNDATION 100044177 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
47 7000024508 40 120 680 WORK ASSOCIATED WITH TOWER FOUNDATION 100044175 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
48 7000024508 40 120 690 WORK ASSOCIATED WITH TOWER FOUNDATION 100044174 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
49 7000024508 40 120 700 WORK ASSOCIATED WITH TOWER FOUNDATION 100044173 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
50 7000024508 40 120 710 WORK ASSOCIATED WITH TOWER FOUNDATION 100044172 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
51 7000024508 40 120 740 WORK ASSOCIATED WITH TOWER FOUNDATION 100044169 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 56 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
52 7000024508 40 120 750 WORK ASSOCIATED WITH TOWER FOUNDATION 100044168 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 200 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
53 7000024508 40 120 760 WORK ASSOCIATED WITH TOWER FOUNDATION 100044167 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
54 7000024508 40 120 770 WORK ASSOCIATED WITH TOWER FOUNDATION 100044166 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 72 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
55 7000024508 40 120 780 WORK ASSOCIATED WITH TOWER FOUNDATION 100044165 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 204 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
56 7000024508 40 120 790 WORK ASSOCIATED WITH TOWER FOUNDATION 100044164 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
57 7000024508 40 120 800 WORK ASSOCIATED WITH TOWER FOUNDATION 100044163 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 100 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
58 7000024508 40 120 810 WORK ASSOCIATED WITH TOWER FOUNDATION 100044162 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 348 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
59 7000024508 40 120 820 WORK ASSOCIATED WITH TOWER FOUNDATION 100044161 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
60 7000024508 40 120 830 WORK ASSOCIATED WITH TOWER FOUNDATION 100044160 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 256 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
61 7000024508 40 120 840 WORK ASSOCIATED WITH TOWER FOUNDATION 100044159 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 100 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
62 7000024508 50 130 10 ERECTION 100044242 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 19 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
63 7000024508 50 130 20 ERECTION 100044243 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
64 7000024508 50 130 30 ERECTION 100044244 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 165 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
65 7000024508 50 130 40 ERECTION 100044245 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 44 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
66 7000024508 50 130 50 ERECTION 100044246 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 35 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
67 7000024508 50 130 60 ERECTION 100044247 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
68 7000024508 50 130 70 ERECTION 100044248 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 94 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
69 7000024508 50 130 80 ERECTION 100044249 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 181 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
70 7000024508 50 130 90 ERECTION 100044250 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
71 7000024508 50 130 100 ERECTION 100044251 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 35 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
72 7000024508 50 130 110 ERECTION 100044252 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
73 7000024508 50 130 120 ERECTION 100044253 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 78 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
74 7000024508 50 130 130 ERECTION 100044241 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 62 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
75 7000024508 50 130 140 ERECTION 100044240 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 63 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
76 7000024508 50 130 150 ERECTION 100044239 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 428 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
77 7000024508 50 130 160 ERECTION 100044238 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
78 7000024508 50 130 170 ERECTION 100044237 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 152 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
79 7000024508 50 130 180 ERECTION 100044236 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 76 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
80 7000024508 50 130 190 ERECTION 100044235 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 92 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
81 7000024508 50 130 200 ERECTION 100044234 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 108 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
82 7000024508 50 130 210 ERECTION 100044233 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DD (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DD . EA 83 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
83 7000024508 50 130 220 ERECTION 100044232 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DC . EA 89 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
84 7000024508 50 130 230 ERECTION 100044231 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DB . EA 148 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
85 7000024508 50 130 240 ERECTION 100044230 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DA . EA 111 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
86 7000024508 60 150 10 INSTALLATION OF EARTHING OF TOWERS 100002202 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/ counterpoisetype)-Pipe type EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
87 7000024508 60 150 20 INSTALLATION OF EARTHING OF TOWERS 170002471 Installation of Chemical earthing of towers: Pipe Type . EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
88 7000024508 60 150 30 INSTALLATION OF EARTHING OF TOWERS 100018257 Installation of Shieldwire Earthing Counterpoise (4X30M) type including PG clamps, Downlead clamps and Earthwire bits. Shieldwireearthing (Pipe Type/counterpoise type) shall be an in addition to Tower Earthing (Pipe type/counterpoise type) EA 10 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
89 7000024508 60 150 40 INSTALLATION OF EARTHING OF TOWERS 100008105 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 39 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
90 7000024508 60 150 50 INSTALLATION OF EARTHING OF TOWERS 100004928 ROD TYPE EARTHING EA 43 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
91 7000024508 60 150 60 INSTALLATION OF EARTHING OF TOWERS 100001270 Installation of earthing of towers: Counterpoise type (120 m length) EA 349 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
92 7000024508 60 150 70 INSTALLATION OF EARTHING OF TOWERS 100001269 Installation of earthing of towers: Pipe Type EA 39 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
93 7000024508 70 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 Installation of tower accessories : Danger Plate EA 431 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
94 7000024508 70 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 Installation of tower accessories: Number Plate EA 431 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
95 7000024508 70 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 Installation of tower accessories: Phase Plate (Set of three) SET 431 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
96 7000024508 70 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 Installation of tower accessories: Circuit Plate (Set of two) SET 431 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
97 7000024508 70 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 Installation of tower accessories: Anti-Climbing Devices EA 431 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
98 7000024508 70 160 60 INSTALLATION OF TOWER ACCESSORIES 100001279 Installation of tower accessories: Bird Guard (Set of Three) SET 111 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
99 7000024508 80 180 10 STRINGING 100044268 Installation of insulator strings complete with arcing horns and necessary hardware, installing and stringing ofconductorincludingfixing of conductor accessories, installing and stringing of earthwire/OPGW including fixing of earthwire/OPGWaccessories for 66 kV double circuit towers (one ckt out of two ckts) with single PANTHER conductor. KM 70 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
100 7000024508 90 190 10 PAINTING 100001285 Painting of towers MT 430 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
101 7000024508 100 200 10 AVIATION 100001282 Installation of Span Markers for aviation requirements EA 43 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
102 7000024508 100 200 20 AVIATION 100001283 Installation of Obstruction Lights for Aviation requirements 1 Medium Intensity Plus 2 Low Intensity SET 22 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
103 7000024508 100 200 30 AVIATION 100001284 Installation of Obstruction Lights for Aviation requirements: 1 Medium Intensity + 4 Low Intensity SET 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
104 7000024508 110 210 10 BENCHING 100001252 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 8495 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
105 7000024508 110 210 20 BENCHING 100001253 Benching: Fissured Rock M3 2322 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
106 7000024508 110 210 30 BENCHING 100001254 Benching:Hard Rock M3 579 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
107 7000024508 120 220 10 PROTECTION OF TOWER FOOTING 100001264 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 10775 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
108 7000024508 120 220 20 PROTECTION OF TOWER FOOTING 100001267 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 108 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
109 7000024508 120 220 40 PROTECTION OF TOWER FOOTING 100001265 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 1078 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
110 7000024508 130 330 10 CAMP 100023085 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
TL01 Pkg for 66kV Himya-Mudh Nyoma Part1 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
1 7000024508 1010 100 10 SURVEY 100001243 Check survey KM 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
2 7000024508 1010 100 20 SURVEY 100001242 Detailed survey including route alignment, profiling and tower spotting KM 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
3 7000024508 1020 110 10 SOIL INVESTIGATION 100001244 Detailed soil investigation: All kinds of soils except fissured rock and hard rock EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
4 7000024508 1020 110 20 SOIL INVESTIGATION 100001245 Detailed soil investigation: Fissured Rock EA 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
5 7000024508 1030 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100044200 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 6 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
6 7000024508 1030 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100044199 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
7 7000024508 1030 120 30 WORK ASSOCIATED WITH TOWER FOUNDATION 100044221 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
8 7000024508 1030 120 40 WORK ASSOCIATED WITH TOWER FOUNDATION 100044220 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 13 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
9 7000024508 1030 120 50 WORK ASSOCIATED WITH TOWER FOUNDATION 100044219 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
10 7000024508 1030 120 60 WORK ASSOCIATED WITH TOWER FOUNDATION 100044218 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
11 7000024508 1030 120 70 WORK ASSOCIATED WITH TOWER FOUNDATION 100044217 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
12 7000024508 1030 120 80 WORK ASSOCIATED WITH TOWER FOUNDATION 100044215 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
13 7000024508 1030 120 90 WORK ASSOCIATED WITH TOWER FOUNDATION 100044214 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 21 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
14 7000024508 1030 120 100 WORK ASSOCIATED WITH TOWER FOUNDATION 100044213 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
15 7000024508 1030 120 110 WORK ASSOCIATED WITH TOWER FOUNDATION 100044212 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 15 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
16 7000024508 1030 120 120 WORK ASSOCIATED WITH TOWER FOUNDATION 100044202 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 6 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
17 7000024508 1030 120 130 WORK ASSOCIATED WITH TOWER FOUNDATION 100044205 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
18 7000024508 1030 120 140 WORK ASSOCIATED WITH TOWER FOUNDATION 100044208 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
19 7000024508 1030 120 150 WORK ASSOCIATED WITH TOWER FOUNDATION 100044262 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.). EA 284 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
20 7000024508 1030 120 160 WORK ASSOCIATED WITH TOWER FOUNDATION 100044263 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 382 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
21 7000024508 1030 120 170 WORK ASSOCIATED WITH TOWER FOUNDATION 100044264 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 226 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
22 7000024508 1030 120 180 WORK ASSOCIATED WITH TOWER FOUNDATION 100044265 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 207 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
23 7000024508 1030 120 190 WORK ASSOCIATED WITH TOWER FOUNDATION 100044255 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
24 7000024508 1030 120 200 WORK ASSOCIATED WITH TOWER FOUNDATION 100044256 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
25 7000024508 1030 120 210 WORK ASSOCIATED WITH TOWER FOUNDATION 100044257 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
26 7000024508 1030 120 220 WORK ASSOCIATED WITH TOWER FOUNDATION 100044259 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
27 7000024508 1030 120 230 WORK ASSOCIATED WITH TOWER FOUNDATION 100044260 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
28 7000024508 1030 120 240 WORK ASSOCIATED WITH TOWER FOUNDATION 100044179 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
29 7000024508 1030 120 250 WORK ASSOCIATED WITH TOWER FOUNDATION 100044180 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 21 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
30 7000024508 1030 120 260 WORK ASSOCIATED WITH TOWER FOUNDATION 100044181 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
31 7000024508 1030 120 270 WORK ASSOCIATED WITH TOWER FOUNDATION 100044182 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
32 7000024508 1030 120 280 WORK ASSOCIATED WITH TOWER FOUNDATION 100044183 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 9 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
33 7000024508 1030 120 290 WORK ASSOCIATED WITH TOWER FOUNDATION 100044185 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 15 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
34 7000024508 1030 120 300 WORK ASSOCIATED WITH TOWER FOUNDATION 100044186 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
35 7000024508 1030 120 310 WORK ASSOCIATED WITH TOWER FOUNDATION 100044188 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 15 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
36 7000024508 1030 120 320 WORK ASSOCIATED WITH TOWER FOUNDATION 100044189 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
37 7000024508 1030 120 330 WORK ASSOCIATED WITH TOWER FOUNDATION 100044194 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
38 7000024508 1030 120 340 WORK ASSOCIATED WITH TOWER FOUNDATION 100044211 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 6 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
39 7000024508 1030 120 350 WORK ASSOCIATED WITH TOWER FOUNDATION 100044172 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
40 7000024508 1030 120 360 WORK ASSOCIATED WITH TOWER FOUNDATION 100044169 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
41 7000024508 1030 120 370 WORK ASSOCIATED WITH TOWER FOUNDATION 100044168 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 129 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
42 7000024508 1030 120 380 WORK ASSOCIATED WITH TOWER FOUNDATION 100044167 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
43 7000024508 1030 120 390 WORK ASSOCIATED WITH TOWER FOUNDATION 100044166 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
44 7000024508 1030 120 400 WORK ASSOCIATED WITH TOWER FOUNDATION 100044165 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 131 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
45 7000024508 1030 120 410 WORK ASSOCIATED WITH TOWER FOUNDATION 100044164 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
46 7000024508 1030 120 420 WORK ASSOCIATED WITH TOWER FOUNDATION 100044163 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 68 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
47 7000024508 1030 120 430 WORK ASSOCIATED WITH TOWER FOUNDATION 100044162 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 225 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
48 7000024508 1030 120 440 WORK ASSOCIATED WITH TOWER FOUNDATION 100044161 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 13 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
49 7000024508 1030 120 450 WORK ASSOCIATED WITH TOWER FOUNDATION 100044160 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 165 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
50 7000024508 1030 120 460 WORK ASSOCIATED WITH TOWER FOUNDATION 100044159 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 63 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
51 7000024508 1040 130 10 ERECTION 100044242 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
52 7000024508 1040 130 20 ERECTION 100044243 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
53 7000024508 1040 130 30 ERECTION 100044244 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 106 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
54 7000024508 1040 130 40 ERECTION 100044245 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 31 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
55 7000024508 1040 130 50 ERECTION 100044246 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
56 7000024508 1040 130 60 ERECTION 100044247 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
57 7000024508 1040 130 70 ERECTION 100044248 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 61 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
58 7000024508 1040 130 80 ERECTION 100044249 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 115 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
59 7000024508 1040 130 90 ERECTION 100044250 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
60 7000024508 1040 130 100 ERECTION 100044251 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
61 7000024508 1040 130 110 ERECTION 100044252 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
62 7000024508 1040 130 120 ERECTION 100044253 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 51 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
63 7000024508 1040 130 130 ERECTION 100044241 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 42 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
64 7000024508 1040 130 140 ERECTION 100044240 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 43 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
65 7000024508 1040 130 150 ERECTION 100044239 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
66 7000024508 1040 130 160 ERECTION 100044238 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
67 7000024508 1040 130 170 ERECTION 100044237 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 99 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
68 7000024508 1040 130 180 ERECTION 100044236 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 49 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
69 7000024508 1040 130 190 ERECTION 100044235 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 59 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
70 7000024508 1040 130 200 ERECTION 100044234 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 68 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
71 7000024508 1040 130 210 ERECTION 100044233 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DD (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DD . EA 52 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
72 7000024508 1040 130 220 ERECTION 100044232 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DC . EA 57 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
73 7000024508 1040 130 230 ERECTION 100044231 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DB . EA 96 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
74 7000024508 1040 130 240 ERECTION 100044230 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DA . EA 71 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
75 7000024508 1050 150 10 INSTALLATION OF EARTHING OF TOWERS 100002202 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/ counterpoisetype)-Pipe type EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
76 7000024508 1050 150 20 INSTALLATION OF EARTHING OF TOWERS 170002471 Installation of Chemical earthing of towers: Pipe Type . EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
77 7000024508 1050 150 30 INSTALLATION OF EARTHING OF TOWERS 100018257 Installation of Shieldwire Earthing Counterpoise (4X30M) type including PG clamps, Downlead clamps and Earthwire bits. Shieldwireearthing (Pipe Type/counterpoise type) shall be an in addition to Tower Earthing (Pipe type/counterpoise type) EA 6 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
78 7000024508 1050 150 40 INSTALLATION OF EARTHING OF TOWERS 100008105 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 25 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
79 7000024508 1050 150 50 INSTALLATION OF EARTHING OF TOWERS 100004928 ROD TYPE EARTHING EA 27 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
80 7000024508 1050 150 60 INSTALLATION OF EARTHING OF TOWERS 100001270 Installation of earthing of towers: Counterpoise type (120 m length) EA 225 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
81 7000024508 1050 150 70 INSTALLATION OF EARTHING OF TOWERS 100001269 Installation of earthing of towers: Pipe Type EA 25 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
82 7000024508 1060 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 Installation of tower accessories : Danger Plate EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
83 7000024508 1060 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 Installation of tower accessories: Number Plate EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
84 7000024508 1060 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 Installation of tower accessories: Phase Plate (Set of three) SET 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
85 7000024508 1060 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 Installation of tower accessories: Circuit Plate (Set of two) SET 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
86 7000024508 1060 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 Installation of tower accessories: Anti-Climbing Devices EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
87 7000024508 1060 160 60 INSTALLATION OF TOWER ACCESSORIES 100001279 Installation of tower accessories: Bird Guard (Set of Three) SET 71 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
88 7000024508 1070 180 10 STRINGING 100044268 Installation of insulator strings complete with arcing horns and necessary hardware, installing and stringing ofconductorincludingfixing of conductor accessories, installing and stringing of earthwire/OPGW including fixing of earthwire/OPGWaccessories for 66 kV double circuit towers (one ckt out of two ckts) with single PANTHER conductor. KM 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
89 7000024508 1080 190 10 PAINTING 100001285 Painting of towers MT 270 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
90 7000024508 1090 200 10 AVIATION 100001282 Installation of Span Markers for aviation requirements EA 27 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
91 7000024508 1090 200 20 AVIATION 100001283 Installation of Obstruction Lights for Aviation requirements 1 Medium Intensity Plus 2 Low Intensity SET 14 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
92 7000024508 1090 200 30 AVIATION 100001284 Installation of Obstruction Lights for Aviation requirements: 1 Medium Intensity + 4 Low Intensity SET 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
93 7000024508 1100 210 10 BENCHING 100001252 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 5453 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
94 7000024508 1100 210 20 BENCHING 100001253 Benching: Fissured Rock M3 1490 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
95 7000024508 1100 210 30 BENCHING 100001254 Benching:Hard Rock M3 372 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
96 7000024508 1110 220 10 PROTECTION OF TOWER FOOTING 100001264 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 6916 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
97 7000024508 1110 220 20 PROTECTION OF TOWER FOOTING 100001267 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 69 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
98 7000024508 1110 220 30 PROTECTION OF TOWER FOOTING 100001265 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 692 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
99 7000024508 1120 330 10 CAMP 100023085 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
TL01 Pkg for 66kV Tangste-Phobrang 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
1 7000024508 1770 100 10 SURVEY 100001243 Check survey KM 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
2 7000024508 1770 100 20 SURVEY 100001242 Detailed survey including route alignment, profiling and tower spotting KM 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
3 7000024508 1780 110 10 SOIL INVESTIGATION 100001244 Detailed soil investigation: All kinds of soils except fissured rock and hard rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
4 7000024508 1780 110 20 SOIL INVESTIGATION 100001245 Detailed soil investigation: Fissured Rock EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
5 7000024508 1780 110 30 SOIL INVESTIGATION 100001246 Detailed soil investigation: Hard Rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
6 7000024508 1790 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100044200 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
7 7000024508 1790 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100044227 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
8 7000024508 1790 120 30 WORK ASSOCIATED WITH TOWER FOUNDATION 100044224 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
9 7000024508 1790 120 40 WORK ASSOCIATED WITH TOWER FOUNDATION 100044220 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
10 7000024508 1790 120 50 WORK ASSOCIATED WITH TOWER FOUNDATION 100044219 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
11 7000024508 1790 120 60 WORK ASSOCIATED WITH TOWER FOUNDATION 100044218 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
12 7000024508 1790 120 70 WORK ASSOCIATED WITH TOWER FOUNDATION 100044217 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
13 7000024508 1790 120 80 WORK ASSOCIATED WITH TOWER FOUNDATION 100044215 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
14 7000024508 1790 120 90 WORK ASSOCIATED WITH TOWER FOUNDATION 100044214 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
15 7000024508 1790 120 100 WORK ASSOCIATED WITH TOWER FOUNDATION 100044213 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
16 7000024508 1790 120 110 WORK ASSOCIATED WITH TOWER FOUNDATION 100044212 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
17 7000024508 1790 120 120 WORK ASSOCIATED WITH TOWER FOUNDATION 100044201 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
18 7000024508 1790 120 130 WORK ASSOCIATED WITH TOWER FOUNDATION 100044202 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
19 7000024508 1790 120 140 WORK ASSOCIATED WITH TOWER FOUNDATION 100044204 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
20 7000024508 1790 120 150 WORK ASSOCIATED WITH TOWER FOUNDATION 100044205 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
21 7000024508 1790 120 160 WORK ASSOCIATED WITH TOWER FOUNDATION 100044208 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
22 7000024508 1790 120 170 WORK ASSOCIATED WITH TOWER FOUNDATION 100044262 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.). EA 284 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
23 7000024508 1790 120 180 WORK ASSOCIATED WITH TOWER FOUNDATION 100044263 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 378 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
24 7000024508 1790 120 190 WORK ASSOCIATED WITH TOWER FOUNDATION 100044264 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 229 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
25 7000024508 1790 120 200 WORK ASSOCIATED WITH TOWER FOUNDATION 100044265 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 205 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
26 7000024508 1790 120 210 WORK ASSOCIATED WITH TOWER FOUNDATION 100044255 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
27 7000024508 1790 120 220 WORK ASSOCIATED WITH TOWER FOUNDATION 100044256 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
28 7000024508 1790 120 230 WORK ASSOCIATED WITH TOWER FOUNDATION 100044257 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
29 7000024508 1790 120 240 WORK ASSOCIATED WITH TOWER FOUNDATION 100044259 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
30 7000024508 1790 120 250 WORK ASSOCIATED WITH TOWER FOUNDATION 100044260 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
31 7000024508 1790 120 260 WORK ASSOCIATED WITH TOWER FOUNDATION 100044261 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
32 7000024508 1790 120 270 WORK ASSOCIATED WITH TOWER FOUNDATION 100044179 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
33 7000024508 1790 120 280 WORK ASSOCIATED WITH TOWER FOUNDATION 100044180 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
34 7000024508 1790 120 290 WORK ASSOCIATED WITH TOWER FOUNDATION 100044182 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
35 7000024508 1790 120 300 WORK ASSOCIATED WITH TOWER FOUNDATION 100044183 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
36 7000024508 1790 120 310 WORK ASSOCIATED WITH TOWER FOUNDATION 100044184 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
37 7000024508 1790 120 320 WORK ASSOCIATED WITH TOWER FOUNDATION 100044185 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
38 7000024508 1790 120 330 WORK ASSOCIATED WITH TOWER FOUNDATION 100044186 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
39 7000024508 1790 120 340 WORK ASSOCIATED WITH TOWER FOUNDATION 100044187 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
40 7000024508 1790 120 350 WORK ASSOCIATED WITH TOWER FOUNDATION 100044188 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
41 7000024508 1790 120 360 WORK ASSOCIATED WITH TOWER FOUNDATION 100044189 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
42 7000024508 1790 120 370 WORK ASSOCIATED WITH TOWER FOUNDATION 100044192 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
43 7000024508 1790 120 380 WORK ASSOCIATED WITH TOWER FOUNDATION 100044193 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
44 7000024508 1790 120 390 WORK ASSOCIATED WITH TOWER FOUNDATION 100044196 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
45 7000024508 1790 120 400 WORK ASSOCIATED WITH TOWER FOUNDATION 100044211 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
46 7000024508 1790 120 410 WORK ASSOCIATED WITH TOWER FOUNDATION 100044177 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
47 7000024508 1790 120 420 WORK ASSOCIATED WITH TOWER FOUNDATION 100044176 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
48 7000024508 1790 120 430 WORK ASSOCIATED WITH TOWER FOUNDATION 100044175 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
49 7000024508 1790 120 440 WORK ASSOCIATED WITH TOWER FOUNDATION 100044174 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
50 7000024508 1790 120 450 WORK ASSOCIATED WITH TOWER FOUNDATION 100044173 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
51 7000024508 1790 120 460 WORK ASSOCIATED WITH TOWER FOUNDATION 100044172 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
52 7000024508 1790 120 470 WORK ASSOCIATED WITH TOWER FOUNDATION 100044169 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
53 7000024508 1790 120 480 WORK ASSOCIATED WITH TOWER FOUNDATION 100044168 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 128 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
54 7000024508 1790 120 490 WORK ASSOCIATED WITH TOWER FOUNDATION 100044167 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
55 7000024508 1790 120 500 WORK ASSOCIATED WITH TOWER FOUNDATION 100044166 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 44 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
56 7000024508 1790 120 510 WORK ASSOCIATED WITH TOWER FOUNDATION 100044165 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 132 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
57 7000024508 1790 120 520 WORK ASSOCIATED WITH TOWER FOUNDATION 100044164 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
58 7000024508 1790 120 530 WORK ASSOCIATED WITH TOWER FOUNDATION 100044163 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 72 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
59 7000024508 1790 120 540 WORK ASSOCIATED WITH TOWER FOUNDATION 100044162 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 224 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
60 7000024508 1790 120 550 WORK ASSOCIATED WITH TOWER FOUNDATION 100044161 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
61 7000024508 1790 120 560 WORK ASSOCIATED WITH TOWER FOUNDATION 100044160 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 168 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
62 7000024508 1790 120 570 WORK ASSOCIATED WITH TOWER FOUNDATION 100044159 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 68 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
63 7000024508 1800 130 10 ERECTION 100044242 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
64 7000024508 1800 130 20 ERECTION 100044243 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
65 7000024508 1800 130 30 ERECTION 100044244 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 108 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
66 7000024508 1800 130 40 ERECTION 100044245 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 31 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
67 7000024508 1800 130 50 ERECTION 100044246 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 22 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
68 7000024508 1800 130 60 ERECTION 100044247 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
69 7000024508 1800 130 70 ERECTION 100044248 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 62 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
70 7000024508 1800 130 80 ERECTION 100044249 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 116 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
71 7000024508 1800 130 90 ERECTION 100044250 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
72 7000024508 1800 130 100 ERECTION 100044251 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 22 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
73 7000024508 1800 130 110 ERECTION 100044252 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
74 7000024508 1800 130 120 ERECTION 100044253 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 50 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
75 7000024508 1800 130 130 ERECTION 100044241 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 44 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
76 7000024508 1800 130 140 ERECTION 100044240 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
77 7000024508 1800 130 150 ERECTION 100044239 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 274 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
78 7000024508 1800 130 160 ERECTION 100044238 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
79 7000024508 1800 130 170 ERECTION 100044237 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 100 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
80 7000024508 1800 130 180 ERECTION 100044236 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 48 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
81 7000024508 1800 130 190 ERECTION 100044235 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 60 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
82 7000024508 1800 130 200 ERECTION 100044234 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 68 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
83 7000024508 1800 130 210 ERECTION 100044233 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DD (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DD . EA 52 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
84 7000024508 1800 130 220 ERECTION 100044232 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DC . EA 58 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
85 7000024508 1800 130 230 ERECTION 100044231 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DB . EA 96 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
86 7000024508 1800 130 240 ERECTION 100044230 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DA . EA 71 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
87 7000024508 1810 150 10 INSTALLATION OF EARTHING OF TOWERS 100002202 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/ counterpoisetype)-Pipe type EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
88 7000024508 1810 150 20 INSTALLATION OF EARTHING OF TOWERS 170002471 Installation of Chemical earthing of towers: Pipe Type . EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
89 7000024508 1810 150 30 INSTALLATION OF EARTHING OF TOWERS 100018257 Installation of Shieldwire Earthing Counterpoise (4X30M) type including PG clamps, Downlead clamps and Earthwire bits. Shieldwireearthing (Pipe Type/counterpoise type) shall be an in addition to Tower Earthing (Pipe type/counterpoise type) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
90 7000024508 1810 150 40 INSTALLATION OF EARTHING OF TOWERS 100008105 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 25 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
91 7000024508 1810 150 50 INSTALLATION OF EARTHING OF TOWERS 100004928 ROD TYPE EARTHING EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
92 7000024508 1810 150 60 INSTALLATION OF EARTHING OF TOWERS 100001270 Installation of earthing of towers: Counterpoise type (120 m length) EA 224 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
93 7000024508 1810 150 70 INSTALLATION OF EARTHING OF TOWERS 100001269 Installation of earthing of towers: Pipe Type EA 25 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
94 7000024508 1820 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 Installation of tower accessories : Danger Plate EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
95 7000024508 1820 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 Installation of tower accessories: Number Plate EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
96 7000024508 1820 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 Installation of tower accessories: Phase Plate (Set of three) SET 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
97 7000024508 1820 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 Installation of tower accessories: Circuit Plate (Set of two) SET 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
98 7000024508 1820 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 Installation of tower accessories: Anti-Climbing Devices EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
99 7000024508 1820 160 60 INSTALLATION OF TOWER ACCESSORIES 100001279 Installation of tower accessories: Bird Guard (Set of Three) SET 71 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
100 7000024508 1830 180 10 STRINGING 100044268 Installation of insulator strings complete with arcing horns and necessary hardware, installing and stringing ofconductorincludingfixing of conductor accessories, installing and stringing of earthwire/OPGW including fixing of earthwire/OPGWaccessories for 66 kV double circuit towers (one ckt out of two ckts) with single PANTHER conductor. KM 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
101 7000024508 1840 190 10 PAINTING 100001285 Painting of towers MT 280 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
102 7000024508 1850 200 10 AVIATION 100001282 Installation of Span Markers for aviation requirements EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
103 7000024508 1850 200 20 AVIATION 100001283 Installation of Obstruction Lights for Aviation requirements 1 Medium Intensity Plus 2 Low Intensity SET 14 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
104 7000024508 1850 200 30 AVIATION 100001284 Installation of Obstruction Lights for Aviation requirements: 1 Medium Intensity + 4 Low Intensity SET 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
105 7000024508 1860 210 10 BENCHING 100001252 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 5460 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
106 7000024508 1860 210 20 BENCHING 100001253 Benching: Fissured Rock M3 1492 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
107 7000024508 1860 210 30 BENCHING 100001254 Benching:Hard Rock M3 372 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
108 7000024508 1870 220 10 PROTECTION OF TOWER FOOTING 100001264 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 6925 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
109 7000024508 1870 220 20 PROTECTION OF TOWER FOOTING 100001267 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 69 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
110 7000024508 1870 220 30 PROTECTION OF TOWER FOOTING 100001265 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 693 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
111 7000024508 1880 330 10 CAMP 100023085 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
TL01 Pkg for 66kV Tangste-Chushul 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
1 7000024508 2530 100 10 SURVEY 100001243 Check survey KM 80 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
2 7000024508 2530 100 20 SURVEY 100001242 Detailed survey including route alignment, profiling and tower spotting KM 80 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
3 7000024508 2540 110 10 SOIL INVESTIGATION 100001244 Detailed soil investigation: All kinds of soils except fissured rock and hard rock EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
4 7000024508 2540 110 20 SOIL INVESTIGATION 100001245 Detailed soil investigation: Fissured Rock EA 14 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
5 7000024508 2540 110 30 SOIL INVESTIGATION 100001246 Detailed soil investigation: Hard Rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
6 7000024508 2550 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100044200 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
7 7000024508 2550 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100044199 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
8 7000024508 2550 120 30 WORK ASSOCIATED WITH TOWER FOUNDATION 100044221 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
9 7000024508 2550 120 40 WORK ASSOCIATED WITH TOWER FOUNDATION 100044220 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 24 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
10 7000024508 2550 120 50 WORK ASSOCIATED WITH TOWER FOUNDATION 100044219 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
11 7000024508 2550 120 60 WORK ASSOCIATED WITH TOWER FOUNDATION 100044218 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
12 7000024508 2550 120 70 WORK ASSOCIATED WITH TOWER FOUNDATION 100044217 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
13 7000024508 2550 120 80 WORK ASSOCIATED WITH TOWER FOUNDATION 100044215 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
14 7000024508 2550 120 90 WORK ASSOCIATED WITH TOWER FOUNDATION 100044214 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 40 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
15 7000024508 2550 120 100 WORK ASSOCIATED WITH TOWER FOUNDATION 100044213 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
16 7000024508 2550 120 110 WORK ASSOCIATED WITH TOWER FOUNDATION 100044212 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
17 7000024508 2550 120 120 WORK ASSOCIATED WITH TOWER FOUNDATION 100044201 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
18 7000024508 2550 120 130 WORK ASSOCIATED WITH TOWER FOUNDATION 100044202 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
19 7000024508 2550 120 140 WORK ASSOCIATED WITH TOWER FOUNDATION 100044204 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
20 7000024508 2550 120 150 WORK ASSOCIATED WITH TOWER FOUNDATION 100044205 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
21 7000024508 2550 120 160 WORK ASSOCIATED WITH TOWER FOUNDATION 100044207 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
22 7000024508 2550 120 170 WORK ASSOCIATED WITH TOWER FOUNDATION 100044208 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
23 7000024508 2550 120 180 WORK ASSOCIATED WITH TOWER FOUNDATION 100044262 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.). EA 508 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
24 7000024508 2550 120 190 WORK ASSOCIATED WITH TOWER FOUNDATION 100044263 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 668 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
25 7000024508 2550 120 200 WORK ASSOCIATED WITH TOWER FOUNDATION 100044264 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 404 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
26 7000024508 2550 120 210 WORK ASSOCIATED WITH TOWER FOUNDATION 100044265 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 370 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
27 7000024508 2550 120 220 WORK ASSOCIATED WITH TOWER FOUNDATION 100044255 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
28 7000024508 2550 120 230 WORK ASSOCIATED WITH TOWER FOUNDATION 100044256 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
29 7000024508 2550 120 240 WORK ASSOCIATED WITH TOWER FOUNDATION 100044257 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
30 7000024508 2550 120 250 WORK ASSOCIATED WITH TOWER FOUNDATION 100044259 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
31 7000024508 2550 120 260 WORK ASSOCIATED WITH TOWER FOUNDATION 100044260 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
32 7000024508 2550 120 270 WORK ASSOCIATED WITH TOWER FOUNDATION 100044261 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
33 7000024508 2550 120 280 WORK ASSOCIATED WITH TOWER FOUNDATION 100044179 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
34 7000024508 2550 120 290 WORK ASSOCIATED WITH TOWER FOUNDATION 100044180 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
35 7000024508 2550 120 300 WORK ASSOCIATED WITH TOWER FOUNDATION 100044181 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
36 7000024508 2550 120 310 WORK ASSOCIATED WITH TOWER FOUNDATION 100044182 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 52 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
37 7000024508 2550 120 320 WORK ASSOCIATED WITH TOWER FOUNDATION 100044183 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
38 7000024508 2550 120 330 WORK ASSOCIATED WITH TOWER FOUNDATION 100044184 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
39 7000024508 2550 120 340 WORK ASSOCIATED WITH TOWER FOUNDATION 100044185 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
40 7000024508 2550 120 350 WORK ASSOCIATED WITH TOWER FOUNDATION 100044186 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
41 7000024508 2550 120 360 WORK ASSOCIATED WITH TOWER FOUNDATION 100044187 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
42 7000024508 2550 120 370 WORK ASSOCIATED WITH TOWER FOUNDATION 100044188 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
43 7000024508 2550 120 380 WORK ASSOCIATED WITH TOWER FOUNDATION 100044189 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
44 7000024508 2550 120 390 WORK ASSOCIATED WITH TOWER FOUNDATION 100044192 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
45 7000024508 2550 120 400 WORK ASSOCIATED WITH TOWER FOUNDATION 100044194 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
46 7000024508 2550 120 410 WORK ASSOCIATED WITH TOWER FOUNDATION 100044195 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
47 7000024508 2550 120 420 WORK ASSOCIATED WITH TOWER FOUNDATION 100044196 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
48 7000024508 2550 120 430 WORK ASSOCIATED WITH TOWER FOUNDATION 100044211 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
49 7000024508 2550 120 440 WORK ASSOCIATED WITH TOWER FOUNDATION 100044177 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
50 7000024508 2550 120 450 WORK ASSOCIATED WITH TOWER FOUNDATION 100044175 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
51 7000024508 2550 120 460 WORK ASSOCIATED WITH TOWER FOUNDATION 100044174 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
52 7000024508 2550 120 470 WORK ASSOCIATED WITH TOWER FOUNDATION 100044173 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
53 7000024508 2550 120 480 WORK ASSOCIATED WITH TOWER FOUNDATION 100044172 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
54 7000024508 2550 120 490 WORK ASSOCIATED WITH TOWER FOUNDATION 100044169 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 56 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
55 7000024508 2550 120 500 WORK ASSOCIATED WITH TOWER FOUNDATION 100044168 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 228 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
56 7000024508 2550 120 510 WORK ASSOCIATED WITH TOWER FOUNDATION 100044167 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 15 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
57 7000024508 2550 120 520 WORK ASSOCIATED WITH TOWER FOUNDATION 100044166 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 84 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
58 7000024508 2550 120 530 WORK ASSOCIATED WITH TOWER FOUNDATION 100044165 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 232 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
59 7000024508 2550 120 540 WORK ASSOCIATED WITH TOWER FOUNDATION 100044164 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 14 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
60 7000024508 2550 120 550 WORK ASSOCIATED WITH TOWER FOUNDATION 100044163 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 116 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
61 7000024508 2550 120 560 WORK ASSOCIATED WITH TOWER FOUNDATION 100044162 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 396 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
62 7000024508 2550 120 570 WORK ASSOCIATED WITH TOWER FOUNDATION 100044161 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 22 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
63 7000024508 2550 120 580 WORK ASSOCIATED WITH TOWER FOUNDATION 100044160 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 296 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
64 7000024508 2550 120 590 WORK ASSOCIATED WITH TOWER FOUNDATION 100044159 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 112 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
65 7000024508 2560 130 10 ERECTION 100044242 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 19 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
66 7000024508 2560 130 20 ERECTION 100044243 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
67 7000024508 2560 130 30 ERECTION 100044244 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 190 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
68 7000024508 2560 130 40 ERECTION 100044245 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 53 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
69 7000024508 2560 130 50 ERECTION 100044246 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 40 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
70 7000024508 2560 130 60 ERECTION 100044247 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
71 7000024508 2560 130 70 ERECTION 100044248 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 107 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
72 7000024508 2560 130 80 ERECTION 100044249 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 202 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
73 7000024508 2560 130 90 ERECTION 100044250 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
74 7000024508 2560 130 100 ERECTION 100044251 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 40 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
75 7000024508 2560 130 110 ERECTION 100044252 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
76 7000024508 2560 130 120 ERECTION 100044253 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 91 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
77 7000024508 2560 130 130 ERECTION 100044241 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 70 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
78 7000024508 2560 130 140 ERECTION 100044240 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 72 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
79 7000024508 2560 130 150 ERECTION 100044239 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 490 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
80 7000024508 2560 130 160 ERECTION 100044238 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
81 7000024508 2560 130 170 ERECTION 100044237 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 176 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
82 7000024508 2560 130 180 ERECTION 100044236 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 88 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
83 7000024508 2560 130 190 ERECTION 100044235 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 104 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
84 7000024508 2560 130 200 ERECTION 100044234 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 124 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
85 7000024508 2560 130 210 ERECTION 100044233 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DD (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DD . EA 93 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
86 7000024508 2560 130 220 ERECTION 100044232 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DC . EA 102 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
87 7000024508 2560 130 230 ERECTION 100044231 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DB . EA 168 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
88 7000024508 2560 130 240 ERECTION 100044230 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DA . EA 127 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
89 7000024508 2570 150 10 INSTALLATION OF EARTHING OF TOWERS 100002202 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/ counterpoisetype)-Pipe type EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
90 7000024508 2570 150 20 INSTALLATION OF EARTHING OF TOWERS 170002471 Installation of Chemical earthing of towers: Pipe Type . EA 5 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
91 7000024508 2570 150 30 INSTALLATION OF EARTHING OF TOWERS 100018257 Installation of Shieldwire Earthing Counterpoise (4X30M) type including PG clamps, Downlead clamps and Earthwire bits. Shieldwireearthing (Pipe Type/counterpoise type) shall be an in addition to Tower Earthing (Pipe type/counterpoise type) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
92 7000024508 2570 150 40 INSTALLATION OF EARTHING OF TOWERS 100008105 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 44 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
93 7000024508 2570 150 50 INSTALLATION OF EARTHING OF TOWERS 100004928 ROD TYPE EARTHING EA 49 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
94 7000024508 2570 150 60 INSTALLATION OF EARTHING OF TOWERS 100001270 Installation of earthing of towers: Counterpoise type (120 m length) EA 397 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
95 7000024508 2570 150 70 INSTALLATION OF EARTHING OF TOWERS 100001269 Installation of earthing of towers: Pipe Type EA 44 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
96 7000024508 2580 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 Installation of tower accessories : Danger Plate EA 490 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
97 7000024508 2580 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 Installation of tower accessories: Number Plate EA 490 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
98 7000024508 2580 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 Installation of tower accessories: Phase Plate (Set of three) SET 490 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
99 7000024508 2580 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 Installation of tower accessories: Circuit Plate (Set of two) SET 490 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
100 7000024508 2580 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 Installation of tower accessories: Anti-Climbing Devices EA 490 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
101 7000024508 2580 160 60 INSTALLATION OF TOWER ACCESSORIES 100001279 Installation of tower accessories: Bird Guard (Set of Three) SET 127 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
102 7000024508 2590 180 10 STRINGING 100044268 Installation of insulator strings complete with arcing horns and necessary hardware, installing and stringing ofconductorincludingfixing of conductor accessories, installing and stringing of earthwire/OPGW including fixing of earthwire/OPGWaccessories for 66 kV double circuit towers (one ckt out of two ckts) with single PANTHER conductor. KM 80 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
103 7000024508 2600 190 10 PAINTING 100001285 Painting of towers MT 490 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
104 7000024508 2610 200 10 AVIATION 100001282 Installation of Span Markers for aviation requirements EA 49 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
105 7000024508 2610 200 20 AVIATION 100001283 Installation of Obstruction Lights for Aviation requirements 1 Medium Intensity Plus 2 Low Intensity SET 25 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
106 7000024508 2610 200 30 AVIATION 100001284 Installation of Obstruction Lights for Aviation requirements: 1 Medium Intensity + 4 Low Intensity SET 13 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
107 7000024508 2620 210 10 BENCHING 100001252 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 9658 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
108 7000024508 2620 210 20 BENCHING 100001253 Benching: Fissured Rock M3 2640 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
109 7000024508 2620 210 30 BENCHING 100001254 Benching:Hard Rock M3 659 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
110 7000024508 2630 220 10 PROTECTION OF TOWER FOOTING 100001264 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 12250 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
111 7000024508 2630 220 20 PROTECTION OF TOWER FOOTING 100001267 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 123 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
112 7000024508 2630 220 30 PROTECTION OF TOWER FOOTING 100001265 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 1225 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
113 7000024508 2640 330 10 CAMP 100023085 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
Total Total Installation / Erection Charges (excluding GST) 0.00
Total GST payable on the price quoted if Contract is awarded (Amount) 0.00
Total Total Installation / Erection Charges (including GST) 0.00 0.00 0.00 0.00 0.00 0.00
Total Corrected Price (excl. GST) GST Amount
Date Printed Name
Place Designation
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694 Schedule - 5
Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST on Goods 0.00 Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00 Sales Tax 0.00 Sales Tax 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694 Schedule - 5
Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST on Goods 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694 Schedule - 3
Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Total Ex-Works Price + price for inland transportation and other services required in India to convey the Goods to their final destination (including GST)
2 TOTAL SCHEDULE NO. 2 0.00
Total Installation / Erection Charges (including GST)
GRAND TOTAL [1+2]
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694 Schedule - 6 After Discount
Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3
Installation Charges
4 TOTAL SCHEDULE NO. 4
Training Charges
5 TOTAL SCHEDULE NO. 5
Taxes and Duties
6 TOTAL SCHEDULE NO. 7
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5]
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694 Schedule - 6
Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Sl. No. Description Total Price (INR) From Sch-6 Discount Factors
1 TOTAL SCHEDULE NO. 1 0.00 0.00 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 #REF! 0.00 #REF!
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 #REF! #REF! 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07694 Letter of Discount
LETTER OF DISCOUNT
Contract Services Schedule 1 0.00
Power Grid Corporation of India Ltd., Schedule 2 #REF!
"Saudamini", Plot No.-2 Schedule 3 0.00
Sector-29, (near IFFCO Chowk) Total #REF!
Gurgaon (Haryana) - 122001
Subject : Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Sch-1 Sch-2 Sch-3
1 Discount on lum-sum basis on total price quoted by us without GST. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3, Sch-4 & Sch-7] In Rs. 0.00 #REF! 0.00
2 Discount on percent basis on total price quoted by us without GST. [The discount shall be applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3, Sch-4 & Sch-7] In Percent (%) 0.00 #REF! 0.00
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Rs. 0.00
Schedule-3 : Installation Charges In Rs. 0.00
Schedule-4 : Training Charges In Rs.
Schedule-7 : Type Test Charges In Rs.
4 Discount on percent basis on the Schedules as given below : [The discount shall be applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Percent (%) #REF!
Schedule-3 : Installation Charges In Percent (%) 0.00
Schedule-4 : Training Charges In Percent (%)
Schedule-7 : Type Test Charges In Percent (%)
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation. #DIV/0! #REF! #DIV/0! #DIV/0! #REF!
[Discount will not be calculated authometrically. However, the same shall be considered during evaluation.]
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain, 0.00 #REF! 0.00
Yours faithfully, 0.00000000 #REF! 0.00000000 Discount Factors
For and on behalf of
Date : #REF! Printed Name : 0.00
Place : #REF! Designation : 0.00
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
STATEMENT OF QUOTED / CORRECTED PRICES
ALL FIGURES ARE IN INDIAN RUPEES
SL. PRICE COMPONENT QUOTED PRICE CORRECTED PRICE
1 Price of Plant and Equipment (including Mandatory Spares Parts) to be supplied [Schedule-1] 0.00 #REF!
2 Local Transportation, In-transit Insurance, loading and unloading charges [Schedule-2] #REF! #REF!
3 Installation Charges [Schedule-3] 0.00 0
4 Type Test Charges [Schedule-7] Not Applicable Not Applicable
5 Total Bid Price excluding GST (1+2+3+4) #REF! #REF!
6 Discount NIL NIL
7 Total Bid Price excluding GST (1+2+3+4) #REF! #REF!
8 Taxes & Duties:
GST on Supply of Goods @5% 0.00 0 total GST on supply 291545315.52
GST on Supply of Goods @12% 0.00 0
GST on Supply of Goods @12% 0.00 #REF!
GST on Supply of Goods @18% #REF!
GST on Supply of Goods @28% #REF!
GST on Supply of Installation Services @ 18% 0.00 0
GST on Type Test Charges Not Applicable Not Applicable
9 Total Taxes & Duties 0.00 #REF!
10 Total Bid Price (including Taxes & Duties) #REF! #REF!
Note-1: It may be mentioned that KEC in Schedule-1 & 3 of their bid, have confirmed/deemed confirmed HSN/SAC code. Also, KEC have confirmed/ deemed confirmed rate of GST for all the items/services in Schedule-1 & 3. Hence the GST tax rate as quoted by KEC has been considered to arrive at their total evaluated bid price, in line with the provisions of the Bidding Documents.
Note-2: It may be mentioned that KEC in Schedule-3 of their bid, have quoted unit prices in more than 2 place of decimals. Accordingly, to work out the total corrected price, unit rates quoted by KEC are rounded off to 2 place of decimals.
Transmission line Tower Package TW03 for 765 kV D/C Navasari (New) (South Gujarat) - Padghe line (Gujarat portion) associated with Transmission Network Expansion in Gujarat to increase its ATC from ISTS: Part B; Spec. No.: 5002002154/TOWER/DOM/A04-CC CS -5
Total Ex-Works Price Direct 0.00
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF!
Total Ex-works Price including Type Test charges #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
^ If the item(s) quoted/considered as "Bought-out" in the bid are manufactured at Bidder's works and confirmed to be supplied under “Direct transaction” by the bidder, then the taxes and duties on such items shall be paid/reimbursed by POWERGRID in line with the provisions of Bidding Documents. For this purpose, at the time of award, the Ex-works price (exclusive of taxes & duties) shall be arrived at from the quoted Ex-works price (inclusive of taxes ad duties) by excluding taxes and duties applicable on such items, as on date of Bid opening, in case of supplies from manufacturer proposed in the bid. During contract execution, the taxes and duties on such items shall be paid/reimbursed at actuals, limited to the rates prevailing on date of Bid opening.
Place : Printed Name : --
Total F&I Price (=SUM(I16:I27))
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Total Installaiton Charges #REF!
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Date : (=IF('Sch-1'!B43=0,"", 'Sch-1'!B43)) (="Printed Name : " & IF('Sch-1'!E44=0,"",'Sch-1'!E44))
Place : (=IF('Sch-1'!B44=0,"", 'Sch-1'!B44)) (="Designation : " & IF('Sch-1'!E45=0,"",'Sch-1'!E45))
TOTAL TYPE TEST CHARGES (=SUM(I17:I18))
Date : (='Sch-1'!B43) (="Printed Name : " & 'Sch-1'!E44)
Place : (='Sch-1'!B44) (="Designation : " & 'Sch-1'!E45)
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
#REF! 0.00 #REF! #REF! #REF!
#REF! #REF! #REF! #N/A
#REF! #REF! 0 #REF! #REF! #REF! #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 0 0 #REF! plus
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 0 1 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 1 0 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 1 1 #REF!
#REF! 0 1 0 0 #REF!
1 One 1 One 1 One 1 One #REF! 0 1 0 1 #REF!
2 Two 2 Two 2 Two 2 Two #REF! 0 1 1 0 #REF!
3 Three 3 Three 3 Three 3 Three #REF! 0 1 1 1 #REF!
4 Four 4 Four 4 Four 4 Four #REF! 1 0 0 0 #REF!
5 Five 5 Five 5 Five 5 Five #REF! 1 0 0 1 #REF!
6 Six 6 Six 6 Six 6 Six #REF! 1 0 1 0 #REF!
7 Seven 7 Seven 7 Seven 7 Seven #REF! 1 0 1 1 #REF!
8 Eight 8 Eight 8 Eight 8 Eight #REF! 1 1 0 0 #REF!
9 Nine 9 Nine 9 Nine 9 Nine #REF! 1 1 0 1 #REF!
10 Ten 10 Ten 10 Ten 10 Ten #REF! 1 1 1 0 #REF!
11 Eleven 11 Eleven 11 Eleven 11 Eleven #REF! 1 1 1 1 #REF!
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen #REF! 0 0 0 0 #REF! +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen #REF! 0 0 0 1 #REF! /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen #REF! 0 0 1 0 #REF! /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen #REF! 0 0 1 1 #REF!
20 Twenty 20 Twenty 20 Twenty 20 Twenty #REF! 0 1 0 0 #REF!
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One #REF! 0 1 0 1 #REF!
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two #REF! 0 1 1 0 #REF!
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three #REF! 0 1 1 1 #REF!
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four #REF! 1 0 0 0 #REF!
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five #REF! 1 0 0 1 #REF!
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six #REF! 1 0 1 0 #REF!
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven #REF! 1 0 1 1 #REF!
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight #REF! 1 1 0 0 #REF!
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine #REF! 1 1 0 1 #REF!
30 Thirty 30 Thirty 30 Thirty 30 Thirty #REF! 1 1 1 0 #REF!
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One #REF! 1 1 1 1 #REF!
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Letter of Bid – Technical Part
Date of this Bid submission: [insert date (as day, month and year) of Bid submission]
NIT/RFB No.: [insert number of Bidding process] CC/NT/W-TW/DOM/A06/23/07694
Title of Procurement/ Contract: [Insert here the title] Transmission line package TL01 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
To: POWER GRID CORPORATION OF INDIA LIMITED, GURUGRAM
1.0 We, the undersigned Bidder, hereby submit our Bid, in two parts, namely:
(a) the Technical Part, and
(b) the Financial Part.
2.0 In submitting our Bid we make the following declarations:
(a) No reservations: We have examined and have no reservations to the bidding document (ITB5), including addenda issued in accordance with Instructions to Bidders (ITB 7);
(b) Eligibility: We meet the eligibility requirements and have no conflict of interest in accordance with ITB 3 and Section 3;
(c) Bid/Proposal-Securing Declaration: We have not been suspended nor declared ineligible by the Purchaser based on execution of a Bid Securing Declaration by the Purchaser in accordance with ITB 10.2.2;
(d) Conformity: We offer to supply in conformity with the bidding document and in accordance with the Delivery Schedules specified in the Schedule of Requirements the all the Goods and Related Services as per the scope mentioned in Part 2, Section 6.;
(e) Bid Validity Period: Our Bid shall be valid for the period specified in BDS 17.1 (as amended if applicable) from the date fixed for the deadline for submission of Bids (specified in BDS 21.1 (as amended if applicable), and it shall remain binding upon us and may be accepted at any time before the expiration of that period;
(f) Performance Security: If our Bid is accepted, we commit to obtain a performance security in accordance with the bidding document;
(g) One Bid per Bidder: We are not submitting any other Bid(s) as an individual Bidder, and meet the requirements of ITB 4.2;
(h) Suspension: We, along with any of our subcontractors, suppliers, consultants, manufacturers, or service providers for any part of the contract, are not subject to, and not controlled by any entity or individual that is subject to, a temporary suspension or a blacklist or a debarment or banned as specified in Section 2, Clause 1.3. Further, we are not ineligible under the Purchaser’s country laws or official regulations or pursuant to a decision of the United Nations Security Council;
(i) Binding Contract: We understand that this Bid, together with your written acceptance thereof included in your Letter of Acceptance, shall constitute a binding contract between us, until a formal contract is prepared and executed;
(j) Not Bound to Accept: We understand that you are not bound to accept the lowest evaluated cost/price Bid, the Most Advantageous Bid or any other Bid that you may receive;
(k) Fraud and Corruption: We hereby certify that we have taken steps to ensure that no person acting for us, or on our behalf, engages in any type of Fraud and Corruption;
(l) (applicable only if the bidder is a Joint Venture as per Section 2 of RFB/ bidding document) We have bid as a Joint Venture as per Section 2 of RFB/ bidding document) and in accordance with Clause 2.2.7 of Section 2 we declare and confirm that all partners of the joint venture shall be liable jointly and severally for the execution of the contract in accordance with the contract terms;
(m) We submit appended herewith, as integral part of the Technical Part of our bid, the details/ documents as listed in the table below in the Forms duly filled, as prescribed, along with supporting documentary evidence as required/ specified. We understand and confirm that we would be solely responsible for any errors or omissions in our Bid and your decision in regard to sufficiency and/ or adequacy of the details/ documents comprising our Bid for determining its completeness shall be final and binding.
(n) We have read and understood the provisions of Order no. F.No.6/18/2019-PPD(Order Public Procurement no.1) dated 23/07/2020 regarding “Restriction under Rule 144(xi) of General Financial Rules” and F.No.6/18/2019-PPD (Order Public Procurement no.2) dated 23/07/2020 regarding “Exclusions from Restriction under Rule 144(xi) of General Financial Rules” issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India [hereinafter collectively “DoE Order’’] and any subsequent modifications/Amendments, if any. Particularly, we, the Bidder, have read the clause regarding restrictions on procurement from a ‘Bidder of a country which shares a land border with India’ and on sub-contracting to contractors from such countries. We certify that we, the bidder is not from such a country or, if from such a country, has been registered as per provisions of the Bidding Documents with the Competent Authority and will not subcontract any work to a subcontractor/sub vendor from such countries unless such subcontractor/sub vendorfulfils all requirement in this regard and is eligible to be considered. We further declare that any misrepresentation or submission of false/forged document/information in this regard shall be dealt with as per the provisions of Integrity Pact and/or Bidding Documents and/or POWERGRID’s policy and procedures
Sr. Document Status (Submitted/ Not Submitted/ Not Applicable)
1 This Letter of Bid as per format prescribed in Form 1 given in Section 4 of RFB/ bidding document
2 Bidder Information as per the format prescribed in Form 2 given in Section 4 of RFB/ bidding document Submitted
3 Bid Security or Bid Securing Declaration , as may be specified in ITB 18 Section 3 of RFB/ bidding document, in the form of specified in ITB . Bid Securing Declaration in format prescribed in Form 3A given in Section 4 and Bid Security in the form of Bank Guarantee in format prescribed in Form 3B given in Section 4 of RFB/ bidding document. Not Submitted
4 Power of Attorney by Lead Joint Venture Member/ Sole Bidder authorizing an Individual Designated Representative for the Joint Venture Bidder/ Sole Bidder as per the format prescribed in Form 4 given in Section 4 of RFB/ bidding document Not Applicable
4A List of Special Maintenance Tools & Tackles included in bid price in Form 4A given in Section 4 of RFB/ bidding document
4B List of Special Maintenance Tools & Tackles not included in bid price in Form 4B given in Section 4 of RFB/ bidding document
5 Declaration of conformance of the Bidder and the Facilities offered, to the specified eligibility requirement specified in Section 2 and Section 3, as per the format prescribed in Form 5 given in Section 4 of RFB/ bidding document
6A Local Content Certificate for Class I Local Supplier, as specified in Clause 1.5 of Section 2 of RFB/ bidding document, Affidavit of Self certification as per the format prescribed in Form 6A given in Section 4 of RFB/ bidding document or by certificate (format not specified) of Statutory Auditor, as may be applicable
6B Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order and MoP order, if applicable [to be submitted on the letter head of the issuer.], in line with specified in Clause 1.5 of Section 2 of RFB/ bidding document as per the format prescribed in Form 6B given in Section 4 of RFB/ bidding document
7 Power of Attorney by each member/ partner of the Joint Venture in favour of Lead member/ partner as per format prescribed in Form 7 given in Section 4 of RFB/ bidding document (applicable only for Joint Venture Bidder)
8 (A) Joint Deed of Undertaking (JDU) signed by each member/ partner of the Joint Venture, as per format prescribed in Form 8 given in Section 4 of RFB/ bidding document (applicable only for Joint Venture Bidder)
8 B Joint Venture Agreement entered amongst all the partners/ members of the Joint Venture in their own format but without violating any of the requirements of the bidding documents and necessarily including the confirmation as specified in Clause 2.2.7 of Section 2 of RFB/ bidding document (applicable only for Joint Venture Bidder)
9 Details/ Data and documentary evidence in support of meeting the Qualification Requirement specified in Section 2 of RFB/ bidding document, as per the format prescribed in Form 9 given in Section 4 of RFB/ bidding document
10 The details of all major items of Plant and Installation Services proposed to be subcontracted in case of award, indicating name and nationality of the proposed subcontractor/sub-vendor for each item, as per the format prescribed in Form 10 given in Section 4 of RFB/ bidding document as per the format prescribed in Form 1 given in Section 4
11 Form of Undertaking on Compliance of Terms & Conditions of the RFB/ bidding document including Scope of Work and other related requirements, as per the format prescribed in Form 11 given in Section 4 of RFB/ bidding document, subject to Sl No. 12 below of this table
12 Statement of Deviation from the requirements specified in the RFB/ bidding documents including Conditions of Contract, Employer’s Requirement/ Specification and Drawings etc, including, inter alia, the cost of withdrawal thereof, as per the format prescribed in Form 12 given in Section 4 of RFB/ bidding document
13 Work Completion Schedule, as per the format prescribed in Form 13 given in Section 4 of RFB/ bidding document
14 Guarantee Declaration, as per the format prescribed in Form 14 given in Section 4 of RFB/ bidding document
15 Information regarding ex-employees of Employer in our firm, as per the format prescribed in Form 15 given in Section 4 of RFB/ bidding document
16 Filled up information regarding Price Adjustment Data, as per the format prescribed in Form 16 given in Section 4 of RFB/ bidding document
17 Option for Interest bearing Initial Advance payment and Information for E-payment, PF details and declaration regarding Micro/Small & Medium Enterprises, as per the format prescribed in Form 17 given in Section 4 of RFB/ bidding document
18 Declaration for tax exemptions, reductions, allowances or benefits, as per the format prescribed in Form 18 given in Section 4 of RFB/ bidding document
19 Bank Guarantee verification checklist, as per the format prescribed in Form 19 given in Section 4 of RFB/ bidding document
20 Additional Information, if any, as per the format prescribed in Form 20 given in Section 4 of RFB/ bidding document
21 Integrity Pact, duly signed on each page by the person signing the bid, as per the format prescribed in Form 21 given in Section 4 of RFB/ bidding document
22 Declaration regarding events encountered pursuant to ITB Clause 1.8, as per the format prescribed in Form 22 given in Section 4 of RFB/ bidding document
23 Declaration of Key Managerial Person jointly with Power of Attorney holder, as per the format prescribed in Form 23 given in Section 4 of RFB/ bidding document
(n) We are also submitting herewith the Financial Part of our Bid, online separately, as per the prescribed Forms given in Section 5 of RFB/ bidding document, complete in all respects in electronic form only, as per the requirements of RFB/ bidding document. We confirm that the same does not contain any deviation, reservation or omission, failing which it is liable to be rejected.
(O) Contact Person
Details of the contact person representing us supported by the Power of Attorney, as prescribed, are furnished as under:
Designation: ………………………………………………….
For a joint venture, the lead partner of the joint venture shall furnish and declare the above Letter of Bid - Technical Part
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Price_schedule.xlsx
xlsx • 1.09 MB
Part-3.docx
docx • 0.59 MB
Annexure-A (BDS).docx
docx • 0.03 MB
FORM-1_Letter of Bid-TL01.xlsx
xlsx • 0.02 MB
Part-1.docx
docx • 0.41 MB
132kV-765kV DC std hw (Part-5).pdf
pdf • 8.03 MB
132kV-765kV DC std hw (Part-1).pdf
pdf • 9.30 MB
132kV-765kV DC std hw (Part-3).pdf
pdf • 7.94 MB
132kV-765kV DC std hw (Part-4).pdf
pdf • 8.39 MB
132kV-765kV DC std hw (Part-2).pdf
pdf • 10.32 MB
132kV-765kV DC std hw (Part-6).pdf
pdf • 3.53 MB
pile earthing Drawing.pdf
pdf • 0.30 MB
Revised Bird Guard Sheet 1 of 2.pdf
pdf • 0.10 MB
Revised Bird Guard Sheet 2 of 2 .pdf
pdf • 0.11 MB
Rod Type Earthing.pdf
pdf • 0.15 MB
Standard drum Drawing Conductor & Earth Wire.pdf
pdf • 0.71 MB
Steel Drum Drawing (HTLS Conductor).pdf
pdf • 0.25 MB
Tower & Access R1.pdf
pdf • 2.86 MB
Wooden Drum Drawing (HTLS Conductor).pdf
pdf • 0.22 MB
08_2Section VIII(Disc Insulator) .pdf
pdf • 0.66 MB
132kV and 220kV Typical Tower.pdf
pdf • 0.04 MB
220 KV SISP WITH BALANCING WT Model (1).pdf
pdf • 0.08 MB
220KV DT.pdf
pdf • 0.11 MB
220kV fittings with deer conductor.pdf
pdf • 0.38 MB
500HVDC- 765SC string drg.pdf
pdf • 0.86 MB
66KV STD FITTINGS.pdf
pdf • 2.24 MB
800kV HVDC string drg.pdf
pdf • 1.63 MB
BFD DRAWING.pdf
pdf • 0.52 MB
bird gurad for V String.pdf
pdf • 0.35 MB
Chemical Counterpoise.pdf
pdf • 0.10 MB
Chemical Pipe Type.pdf
pdf • 0.10 MB
Covered grading Ring Drawing.pdf
pdf • 0.62 MB
Extension application scheme.pdf
pdf • 0.06 MB
GA_A_PROP TYPE SST Model (1).pdf
pdf • 0.17 MB
HARD ROCK EARTHING.pdf
pdf • 0.19 MB
Individual Leg SST.pdf
pdf • 0.58 MB
Insulator Packing drawing PVC type.pdf
pdf • 0.88 MB
Insulator Packing drawing.pdf
pdf • 0.09 MB
12_Section XII FAQ.pdf
pdf • 0.37 MB
06_1 Section VI A Hardware Fittings Clamp and Accessories for Conductor & Earthwire Rev-2(Jan'22).pdf
pdf • 4.24 MB
07_1 Section VII A Conductor,Rev-2(Jan'2022).pdf
pdf • 1.15 MB
07_2 Section VII A (SMQP of Conductor).pdf
pdf • 4.76 MB
04_5 Section IVC Appendix II(Part-B) Precommissioning Formats, Rev-1 (Sept'2021).pdf
pdf • 2.38 MB
04_6 Section IVC Appendix III (SMQP of Trasnmission Line Tower.pdf
pdf • 3.40 MB
04_7 Section IVD Foundation (Contractor design),Rev-5(March'2023).pdf
pdf • 0.84 MB
05_1 Section V Earthwire.pdf
pdf • 0.37 MB
05_2 Section V (MQP for Earthwire).pdf
pdf • 0.90 MB
01_1 Section IA (standard)ScopeRev-6 (Feb'2023).pdf
pdf • 0.56 MB
01_2 Section IB General InformationRev-7(May 2023).pdf
pdf • 1.00 MB
02 Section II General Tehnical Conditions,Rev-2(Feb'2022).pdf
pdf • 0.84 MB
03_1 Section III Survey & Soil Investigation,Rev-3(March'2023).pdf
pdf • 0.91 MB
03_2 Section III Annexure-A(Format for site BOQ).pdf
pdf • 1.70 MB
03_3 Section III Annexure B-C-D-E(Formats for other site data).pdf
pdf • 0.48 MB
04_1 Section IVA Tower Design,Rev-4(Apr'2022).pdf
pdf • 0.33 MB
04_2 Section IVB Tower Testing,Rev-2(Mar'2023).pdf
pdf • 0.47 MB
04_3 Section IVC Fabrication, Erection & Stringing,Rev-6(APR'2023).pdf
pdf • 1.30 MB
04_4 Section IVC Appendix I (List of T&P).pdf
pdf • 0.83 MB
04_5 Section IVC Appendix II(Part-A) Precommissioning procedure, Rev-1 (Sept'2021).pdf
pdf • 1.89 MB
OBD_EXTN_LETTER.doc
doc • 0.04 MB
OBD_EXTN_LETTER.doc
doc • 0.04 MB
OBD_EXTN_LETTER.pdf
pdf • 0.05 MB
REVISED 01_1 Section IA (standard)ScopeRev-6 (Feb'2023).pdf
pdf • 0.43 MB
OBD_EXTN_LETTER.doc
doc • 0.04 MB
OBD_EXTN_LETTER.doc
doc • 0.04 MB
Clarification-I.pdf
pdf • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .