Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC THE RETREAT NEAR LAKE BORDOLOI NAGAR P O TINSUKIA ASSAM PIN 786 125 D 69 CEEC | TINSUKIA | ASSAM | 786125 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹39.3 L+₹12,280 (0.31%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹39.7 L+₹60,660 (1.55%)Rejected-Finance BORBARUAH BAZAR A T ROAD DIBRUGARH ASSAM | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹40.8 L+₹1.6 L (4.18%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹41.0 L+₹1.8 L (4.66%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹38 L
EMD Value
₹78,000
Closing Date
14 Feb 2023, 6:00 pmClosed
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
SPECIAL REPAIR TO BUILDING NO P-63 OR MD ACCN AT DINJAN MIL STATION
2023_MES_575933_1
84162E8
Open Tender
Civil Works
Item Rate
180 days
GE DINJAN
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE DINJAN
₹78,000
Yes
21 Feb 2023
19 Jan 2023
16 Feb 2023
19 Jan 2023
14 Feb 2023
2 Feb 2023
20 Jan 2023 - 28 Jan 2023
Amount
Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
Demolition of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified.
Providing and fixing inter locking metal grid (anodised aluminium snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge.
Preparation of newly plastered surfaces/boards on ceilings and applying three coats of white wash complete all as specified and as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 16 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed.
Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 20 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed.
Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed.
Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and removing to store complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including taking down old unsv water tank all as specified and as directed.
S & F 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 1mm thk putty to match the existing surfaces complete all as specified and as directed
M & L for preparing new plaster surfaces walls including chajjas, facias etc. and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm X 60 mm, Profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed. Note- PCC filling of hollow section shall be measured and paid seperately.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm X 60 mm, Profile B, single rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, hard wood, factory made, panelled shutters (multi panels) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated.
M & L for 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, hardwood, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge.
S & F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with particle board core, with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing.
S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar works complete all as specified and as directed.
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F medium weight stainless steel butt hinges, 100 mm size, naturally finished bright with smooth surface without chemical coating complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F prelaminated particle board (decorative lamination on one side and other side balancing lamination), 20 mm thick, grade I or II & type II (Designation PLB-12 or PLB-22), made out of medium density particle board (flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWP adhesive), fixed with screws to timber/ steel frame work for horizontal applications as in table tops, counter, furniture tops, etc. complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
S & F 50 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F timber species of group I for frames and durability class I as per IS 12896: 1990 for small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like articles not exceeding 200 cucm each complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete all as specified and as directed.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and fair complete all as specified and directed.
M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. complete all as specified and as directed.
M & L for forming 12 mm thick expansion joints in 100 mm thick slab filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed.
M & L for brushing neat cement slurry with 3.0 kg of cement per square meter complete all as specified & directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 25 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), 300 mm X 300 mm X 7 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:4) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
M & L for glazed, colour ceramic wall tiles (group B III), 450 mm X 350 mm X 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), 400 mm X 400 mm X 8 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), 400 mm X 400 mm X 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
M & L for machine cut mirror polished Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 20 mm thick in cement mortar 1:6, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for 20 to 25 mm thick machine cut mirror polished Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:4, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.
M & L for 20 mm thick machine cut granite tiles (any type) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with granite stone shade including 20 mm thick screed in cement mortar 1:4 including grinding and polishing complete all as specified and as directed.
S & F vitreous china semi pedestal pattern(Anglo-Indian Type), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs in repairs thermoplastic seats and covers of grade 2 type, recessed with hinging device of bronze or brass with nickel chromium plating complete all as specified and as directed.
S & F 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
Providing and fixing galvanised steel holder bat clamps of approved design to 100 mm dia/ bore rain water pipe/ soil waste pipe embedded in and including cement concrete blocks 100 mm X 100 mm X 100 mm of Nominal Mix (M15) using 20 mm nominal size graded crushed stone aggregate and cost of cutting holes and making good at any floor complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes of size 100 mm jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S & F grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and as directed.
S & F swivel shower of PTMT any colour for fixing with 15 mm pipe. minimum weight 40 gms complete all as specified and as directed.
S & F wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F 32 mm nominal size, waste coupling of PTMT (half or full threaded), minimum weight 45 grams with including silicone sealant complete all as specified and as directed.
S & F in repairs 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed.
S & F in repairs 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
S & F in repairs 15 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
M & L for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
M & L for precast cement concrete louvers and jallies, 25 mm thick (measured solid) in cement concrete M15 (Nominal mix) using 12.5 mm nominal size coarse aggregate including all mouldings but excluding frame and fixed in position using cement mortar (1:4) complete all as specified and as directed.
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge.
S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge.
S & F PVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge.
S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge.
S & F PVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F PVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F PVC Tee(87.5⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to draft wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S & F low density polyethylene pipe (LDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal dia 32 mm including all fittings and fixtures fixed to walls ceiling or in floors complete all as specified and as directed.
S & F structural timbers of group B, first or second choice as per IS 3629: 1986, clean sawn with butt joints in boarding fixed in roofs, ceilings, partitions, fascia, barge, soffit, etc. (except flooring and skirting), 20 mm thick fixed with nails in any situation complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed
S & F in repairs 20 mm dia harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and as directed.
M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm X 25 cm X 22 -25 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20 cm wide. (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item 07010) for rough finished flat surfaces of concrete complete all as specified and as directed.
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and complete all as specified and as directed.
Supply only integral water proofing compound.
S & F Kitchen stainless steel plate rack of size 31" X 30" X 10" as per catalogue No. P-346 of Prayag or equivalent of Make mentioned under Appendix ‘B’ to Particular Specification including necessary fixing / fittings & making good the existing surfaces complete all as specified and directed.
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and providing 10 mm thick cement plaster in CM (1:4) using water proofing compound @ 3 % by weight of cement for filling depression if any to receive water proofing treatment and providing APP modified bituminous membrane water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.8 kg/sqm ± 5% per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Sqm by the same membrane manufacture of density at 25 C, 0.87-0.89 kg/litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints including for applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed by Engineer-In-charge (Note : WPC shall be measured and paid separately)
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 40 mm thick as levelling course of roof padding complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S and F for 3mm thk PVC sheet for cupboard purpose all as specified and directed
Material, T&P and labour for cleaning of sewage line of any dia/bore using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any complete all as specified and as directed.
Material, T&P and labour for cleaning of manholes using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any and removing night soil/ silted sludge/ waste material outside MD land unprohibited by any authority and following the statutory law/ guidelines complete all as specified and as directed.
Material, T&P and labour for cleaning of blockage of wash basin, floor trap, nahani trap, gully trap (GT), kitchen, bath etc. (carrying sullage) in any length upto the first manhole by any means (using chemical or any mechanical device) & flushing with water complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the rate quoted by the bidder)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.(Note: Cost of cutting chase and making good shall be included in the rate quoted by the bidder)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4.0 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the rate quoted by the bidder)
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F switch socket combination with (3 pin and 3 pin) having two earthing pins combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A and indicator and fuse complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F call bell suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & F LED tube light nominal power 20 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2200, lumen efficacy of minimum 110 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue No. LHLDCLXEUL83020 of Havells or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F LED tube light fittings nominal power 10 Watt LED , LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 950, lumen efficacy of minimum 95 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, epoxy powder coated white extruded aluminium channel housing, life span of minimum 50000 working hours as per catalogue No. LHEWEBP7IN1W010 of Havells or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F decorative type wall light fittings made of polycarbonate suitable for 10/15 watt retrofit LED including LED 10 watt spiral B22 base as per cat No. LHDL02160099 or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S & F LED Bulb 9/10 watts with high power LEDs as light source complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S&F MCB SP, 10KA, 230V, C-curve, 6-32 amps complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface to match the existing surface complete all as specified and as directed.
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of6 sqmm cable and one run of conduit shall be measured and paid as one unit length.
S & F LED street lights on buildings nominal power 25 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2500, lumen efficacy of minimum 100 lumens per watt, built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LHEWEBP7PL6S025 of Havells or equivalent of Make mentioned under Appendix "B" with and including fixing at any height on building using 1.5 metre medium grade galvanized iron pipe bracket made of 32 mm nominal bore and necessary nuts, bolts, clamps and concreting and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Taking down old unsv and M&L for Test point terminal box made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screwed including removing the existing old unsv one complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Taking down carefully without point wiring by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
Taking down serviceable energy meter /ceiling fan/exhaust fans any sweep, deposite in safe custody after repair work reinstall in original position after minor repair if any complete all as specified and as directed.
Taking down main switch/MCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
Taking down unsv meter box and S&F Thermoplastic polystrene of IP 65, single phase metering cover wall mounted of size 217x253x115 mm with transport glass and necessary fixing nut, bolts and clamp for installations of single phase energy meter. Quoted rate includes connections of respective energy meters at specific locations complete all as specified and directed by Engr in charge. (Make : Hensel of RAL 7035. Note- Fixing of existing meter in the box is included in the quoted rate.
M & L for 4 mm thick thick oceanic pre-primed self embossed non asbestos fiber,flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, cured in HPSC (high pressure steam curing ) process, highly chemical stabilised, design and texture , fixed to timber/GI /Aluminium framework with screw in ceilings flat or sloping complete all as specified as by the Engineer-in-Charge.
SHRI MANOJ KONWAR
M/S Abhi Traders
M/S A K BROTHERS
M H KHAN
M/S BORAH BROTHERS
M/S CHANDAN ENTERPRISE
Garg Brothers
PAUL ENTERPRISE
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .