Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance | ₹1.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹97.5 L−₹39.7 L (28.9%)Admitted-Finance UDAIPUR | ₹97.5 L−₹39.7 L (28.9%) | L2 | Admitted-Finance |
| 3 | L3₹96.9 L−₹40.3 L (29.4%)Admitted-Finance | ₹96.9 L−₹40.3 L (29.4%) | L3 | Admitted-Finance |
| 4 | L4₹95.5 L−₹41.6 L (30.4%)Admitted-Finance | ₹95.5 L−₹41.6 L (30.4%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Jyoti electronics L3 | M/S A.K. Electricals L1 | Prince Enterprises L2 | SOLAR WINGS TECHNOLOGIES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | p &f of single phase smart ccms panel 7.5 kw rating on Existing pcc pole or on a ms angle frame having following Features –1. Schedule the timing of lights (pre-programmed based on astronomical clock or on field or through central control.2) panel should be made of 2mm crca sheet with locable door and Enclosures IP 55 Iot devices (GSM) 3. CCMS shall able to measure Voltage, Current, Power Factor, Active Power, Apparent Power, Metering Cumulative Active Energy, Metering Cumulative Apparent Energy.4. Enclosure should be made of fire retardant FRS/SMC material 5. Communication – GSM/GPRS communication between CCMS and Cloud server 6. Alerts –i. Phase wise over current/Short circuit ii. Phase wise over voltage iii. Group failure of lights iv. No input supply v. Tempering of door vi. Low Power Factor Detection. Vii. Under load and over load detection. 7. Energy-meter – 1 phase Class 1.0 accuracy meter with ISI/IS-13779 Secure / L&T Make. 8. Battery Backup – CCMS supports battery backup up to 12 hours. 9. CCMS Unit shall have analog measurement capability 1 x Analog voltage, 1 x Current input measurement channels 10. Switch gear protection against fast grid switching, overall protection against short circuit and overload. 11. CCMS shall have manual operating switch in case of failure of CCMS controlling unit. 13. Local storage for 30 Day using inbuilt EEPROM 14. Google maps overlay for live status monitoring of CCMS.15. Total monthly/weekly/daily power consumption, on time and saving info.16. Configuration for user hierarchy from the GUI. 17. Incomer : MCB 63 Amp Latch Relay : 60 Amp, Outgoing MCB : 63 Amp 18. SPD : 440 Volts Parallel SPD 20 KV 19 and Gsm antenna. CCMS Make :- Schnell, Matrix and equivalent | 285 | Each | 29,800 ₹84,93,000 Lowest | 42,300 ₹1,20,55,500 | 29,999 ₹85,49,715 | 29,900 ₹85,21,500 |
| 2.00 | p &f of Three phase smart ccms panel 7.5 kw per phase rating on Existing pcc pole or on a ms angle frame having following Features –1. Schedule the timing of lights (pre-programmed based on astronomical clock or on field or through central control.2)panel should be made of 2mm crca sheet With loccable door and Enclosures IP 55 Iot devices (GSM) 3. CCMS shall able to measure Voltage, Current, Power Factor, Active Power, Apparent Power, Metering Cumulative Active Energy, Metering Cumulative Apparent Energy.4. Enclosure should be made of fire retardant FRS/SMC material 5. Communication – GSM/GPRS communication between CCMS and Cloud server 6. Alerts –i. Phase wise over current/Short circuit ii. Phase wise over voltage iii. Group failure of lights iv. No input supply v. Tempering of door vi. Low Power Factor Detection. Vii. Under load and over load detection. 7. Energy-meter – 3 phase Class 1.0 accuracy meter with ISI/IS-13779 Secure / L&T Make. 8. Battery Backup – CCMS supports battery backup up to 12 hours.9. CCMS Unit shall have analog measurement capability 1 x Analog voltage, 1 x Current input measurement channels 10. Switch gear protection against fast grid switching, overall protection against short circuit and overload. 11. CCMS shall have manual operating switch in case of failure of CCMS controlling unit. 13. Local storage for 30 Day using inbuilt EEPROM 14. Google maps overlay for live status monitoring of CCMS.15. Total monthly/weekly/daily power consumption, on time and saving info.16. Configuration for user hierarchy from the GUI. 17. Incomer : MCB 63 Amp Latch Relay : 60 Amp, Outgoing MCB : 63 Amp 18. SPD : 440 Volts Parallel SPD 20 KV 19 and Gsm antenna. CCMS Make :- Schnell, Matrix and equivalent | 28 | Each | 42,700 ₹11,95,600 | 59,400 ₹16,63,200 | 42,999 ₹12,03,972 | 36,900 ₹10,33,200 Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
27 Oct 2025, 6:00 pmClosed
EXECUTIVE ENGINEER LIGHT GREATER
JAIPUR NAGAR NIGAM GREATER PANDIT DEENDAYAL UPPADHYAY BHAWAN LALKOTHI TONK ROAD JAIPUR
WORK OF INSTALLING NEW CCMS IN MUNICIPAL CORPORATION GREATER, JAIPUR JURISDICTION (ANNUAL RATE CONTRACT) YEAR 2025-26
2025_DLB_506845_1
62 EXECUTIVE ENGINEER LIGHT GREATER
Open Tender
Electrical Works
Percentage
365 days
JAIPUR
As Per Bid Documents
3 documents required · 3 mandatory
₹1,500
ONLINE PAY IN JAIPURMC WEBSITE
₹2.8 L
Yes
JAIPUR
30 Oct 2025
13 Oct 2025
28 Oct 2025
13 Oct 2025
27 Oct 2025
17 Oct 2025
15 Oct 2025
Amount
p &f of single phase smart ccms panel 7.5 kw rating on Existing pcc pole or on a ms angle frame having following Features –1. Schedule the timing of lights (pre-programmed based on astronomical clock or on field or through central control.2) panel should be made of 2mm crca sheet with locable door and Enclosures IP 55 Iot devices (GSM) 3. CCMS shall able to measure Voltage, Current, Power Factor, Active Power, Apparent Power, Metering Cumulative Active Energy, Metering Cumulative Apparent Energy.4. Enclosure should be made of fire retardant FRS/SMC material 5. Communication – GSM/GPRS communication between CCMS and Cloud server 6. Alerts –i. Phase wise over current/Short circuit ii. Phase wise over voltage iii. Group failure of lights iv. No input supply v. Tempering of door vi. Low Power Factor Detection. Vii. Under load and over load detection. 7. Energy-meter – 1 phase Class 1.0 accuracy meter with ISI/IS-13779 Secure / L&T Make. 8. Battery Backup – CCMS supports battery backup up to 12 hours. 9. CCMS Unit shall have analog measurement capability 1 x Analog voltage, 1 x Current input measurement channels 10. Switch gear protection against fast grid switching, overall protection against short circuit and overload. 11. CCMS shall have manual operating switch in case of failure of CCMS controlling unit. 13. Local storage for 30 Day using inbuilt EEPROM 14. Google maps overlay for live status monitoring of CCMS.15. Total monthly/weekly/daily power consumption, on time and saving info.16. Configuration for user hierarchy from the GUI. 17. Incomer : MCB 63 Amp Latch Relay : 60 Amp, Outgoing MCB : 63 Amp 18. SPD : 440 Volts Parallel SPD 20 KV 19 and Gsm antenna. CCMS Make :- Schnell, Matrix and equivalent
p &f of Three phase smart ccms panel 7.5 kw per phase rating on Existing pcc pole or on a ms angle frame having following Features –1. Schedule the timing of lights (pre-programmed based on astronomical clock or on field or through central control.2)panel should be made of 2mm crca sheet With loccable door and Enclosures IP 55 Iot devices (GSM) 3. CCMS shall able to measure Voltage, Current, Power Factor, Active Power, Apparent Power, Metering Cumulative Active Energy, Metering Cumulative Apparent Energy.4. Enclosure should be made of fire retardant FRS/SMC material 5. Communication – GSM/GPRS communication between CCMS and Cloud server 6. Alerts –i. Phase wise over current/Short circuit ii. Phase wise over voltage iii. Group failure of lights iv. No input supply v. Tempering of door vi. Low Power Factor Detection. Vii. Under load and over load detection. 7. Energy-meter – 3 phase Class 1.0 accuracy meter with ISI/IS-13779 Secure / L&T Make. 8. Battery Backup – CCMS supports battery backup up to 12 hours.9. CCMS Unit shall have analog measurement capability 1 x Analog voltage, 1 x Current input measurement channels 10. Switch gear protection against fast grid switching, overall protection against short circuit and overload. 11. CCMS shall have manual operating switch in case of failure of CCMS controlling unit. 13. Local storage for 30 Day using inbuilt EEPROM 14. Google maps overlay for live status monitoring of CCMS.15. Total monthly/weekly/daily power consumption, on time and saving info.16. Configuration for user hierarchy from the GUI. 17. Incomer : MCB 63 Amp Latch Relay : 60 Amp, Outgoing MCB : 63 Amp 18. SPD : 440 Volts Parallel SPD 20 KV 19 and Gsm antenna. CCMS Make :- Schnell, Matrix and equivalent
Bidder Name
Amount
Jyoti electronics (GSTN-08AAPFJ3349G1Z2) BID ID -3345470
M/S A.K. Electricals (GSTN-08ACJPC7443G1ZN) BID ID -3347311
Prince Enterprises (GSTN-08CEHPM7643QIZM) BID ID -3348321
SOLAR WINGS TECHNOLOGIES (GSTN-NA) BID ID -3348385
Jyoti electronics (BID ID -3345470)
Prince Enterprises (BID ID -3348321)
M/S A.K. Electricals (BID ID -3347311)
Prince Enterprises (BID ID -3348321)
Jyoti electronics (BID ID -3345470)
SOLAR WINGS TECHNOLOGIES (BID ID -3348385)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
EPROC62XENLIGHT.pdf
Tender Documents • 8.01 MB
BOQ_903298.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .