Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.1 LAccepted-AOC 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L-1 | Accepted-AOC ACCEPTED | |
| 2 | L-2₹37.4 L+₹3.3 L (9.77%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | L-2 | Rejected-Finance Being higher bid value | |
| 3 | L-3₹37.8 L+₹3.7 L (10.9%)Rejected-Finance 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L-3 | Rejected-Finance Being higher bid value | |
| 4 | L-4₹37.9 L+₹3.8 L (11.1%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L-4 | Rejected-Finance Being higher bid value | |
| 5 | L-5₹38.0 L+₹3.9 L (11.3%)Rejected-Finance 117 LENIN SARANI KOLKATA 700 013 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700013 | L-5 | Rejected-Finance Being higher bid value |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alipore
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/RENEWAL TO FAULTY UG CABLES, FEEDER PILLARS, CABLE TRAY AND ALLIED ACCESSORIES AT TURF VIEW, HQ BSA, GOKHALE ROAD AND CWE COMPLEX UNDER GE ALIPORE KOLKATA
2024_MES_642014_1
GE/ALP(8302B) KOLKATA OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Alipore Kolkata
CLASS D Category b (i)
9 documents required · 9 mandatory
₹500
Garrison Engineer Alipore
₹70,000
Yes
GE Alipore Kolkata
16 Apr 2024
13 Feb 2024
14 Mar 2024
13 Feb 2024
11 Mar 2024
27 Feb 2024
13 Feb 2024 - 20 Feb 2024
21 Feb 2024
Amount
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for laying of cable , fixing of pole etc and getting out in soft/loose soil, old serviceable bricks etc complete all as specified and as directed.
Materials and labour for sand filling23 cm thick above the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness of 18 cm complete all as specified and as directed.
Supply and laying for burnt brick sub class 'B' of size 23 X 12.5 X 7.5 cm locally available best quality laid in trenches for protections of under ground cable complete all as specified and as directed.
Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Materials and labour for plain cement concreate (1:3:6) type C2 (using 40 mm gradeed stone aggregrate) as in foundations filling, coping for pole and mass concreate filling of trench across the road etc. complete all as specified and as directed.
Cutting existing metal/bituminus road/PCC walk way/any type of tile works n.exc 0.45m width and n.exc 0.90 m in depth including all connected earth work and making good disturbed surfaces matching with the existing specification and finish including disposal of surplus material to a distance n.exc 50m complete all as specified and as directed.
S&F for 40mm bore GI pipe "light grade" galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or laid in trenches complete all as specified and directed.
S & F GI pipe light grade 50 mm Tubes, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors or laid in trenches complete all as specified and as directed.
M & L for 80mm bore high density polyethylene pipes (HDPE) PN 10 including socket, bends reducers etc fixed complete to walls, ceilings,layed in trenches or in floors etc. complete all as specified and directed.
Disconnecting and taking out old unserviceable LT under ground aluminium cable from trench / walls / ducts and stacking aside for measuring for schedule of credit complete all as specified and directed.
Supply and laying for under ground heavy duty XLPE insulated, armoured aluminium conductor cable 1100 volts grade, cross-sectional area 10 sq. mm 2 core in trenchches / through pipe or bare in road crossing / plingth/ drain/ duct/ floor along pole / wall /ceillings etc complete all as specified and directed. Note:- Earth work, bricks protection sand cushioning shall be measured and paid seperately.
All as per item No 12 here in -before but of size 10 sq. mm 4 core .
All as per item No 12 here in -before but of size 16 sq. mm 4 core .
All as per item No 12 here in -before but of size 25 sq. mm 4 core .
All as per item No 12 here in -before but of size 35 sq. mm 3½ core .
All as per item No 12 here in -before but of size 50 sq. mm 3½ core . .
All as per item No 12 here in -before but of size 70 sq. mm 3.5 core .
All as per item No 12 here in -before but of size 95 sq. mm 3.5 core .
All as per item No 12 here in -before but of size 120 sq. mm 3.5 core .
All as per item No 12 here in -before but of size 185 sq. mm 3.5 core .
All as per item No 12 here in -before but of size 240 sq. mm 3.5 core .
Supply and fixing for heat shrink type straight through cable jointing kit for 1.1 KV grade under ground XLPE insulated aluminium cable complete with Jointing material and other connected accessories suitable for 3.5 / 4 core, 10 to 16 sqmm complete all as specified and directed. Make: 3M / CABSEAL / DENSON
All as per item no 23 above but of size 25sqmm to 50 sqmm complete all as specified and directed. Make: 3M/CABSEAL/DENSON
All as per item no 23 above but of size 70 sqmm to 120 sq. mm 3.5 core . Make : 3M / CABSEAL / DENSON
S&F for perforated GI cable tray, made of plain GI sheet of thickness 1.20 mm, of size 600 mm wide x 75 mm depth with cover duly fixed on wall / roof by M.S. Bracket or hanging from ceiling with down rod etc, all as specified and directed.
All as per item No 26 here in -before but of size 450mm .
All as per item No 26 here in -before but of size 300 mm .
All as per item No 26 here in -before but of size 200 mm .
All as per item No 26 here in -before but of size 100 mm .
Design, supply, erection, testing and commissioning of indoor type LT Panel of overall size not less than 1800mm width x 1800mm Height x 450mm Depth, M.S. Channel Base Frame (to be mounted on the 3 side covered brick pedestal of height 300mm above floor level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 500 amps, Provision of Spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and FRP / DMC Cable connectors for termination of outgoing cables from MCBs.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-42 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears / Pump Starters and Bus Bars and having front and rear opening facility and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :-
Design, supply, erection, testing and commissioning of indoor type LT Panel of overall size not less than 1800mm width x 1800mm Height x 450mm Depth floor mounted . suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 500 amps, Provision of Spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and FRP / DMC Cable connectors for termination of outgoing cables from MCBs.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-42 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears / Pump Starters and Bus Bars and having front and rear opening facility and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :-
Design, supply, erection, testing and commissioning of indoor type LT Panel of overall size not less than 1600mm width x 1500mm Height x 450mm Depth floor mounted . suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 500 amps, Provision of Spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and FRP / DMC Cable connectors for termination of outgoing cables from MCBs.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-42 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears / Pump Starters and Bus Bars and having front and rear opening facility and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :-
M&L for taking out LT Panel from its foundation by taking shut down, breaking PCC foundation, opening the existing cable from the LT Panel board and refixing the same LT Panel after making the fresh foundation with new height to avoid water insertion into LT Panel and connecting the disconnected cable to restore the supply all as specified and directed. (Note: M& L for PCC foundation will be measured and paid in seperate items )
S&F for MCCB 40 Amps, 16 KA 4-Pole type, with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete all as specified and directed. Make : (Legrand / L&T / ABB / Schneider)
S&F for MCCB 63 Amps, 16 KA 4-Pole type, with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete all as specified and directed. Make : (Legrand / L&T / ABB / Schneider)
S&F for MCCB 100 Amps, 16 KA 4-Pole type, with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete all as specified and directed. Make : (Legrand / L&T / ABB / Schneider)
S&F for MCCB 125 Amps, 25 KA 4-Pole type,with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete all as specified and directed. Make : (Legrand / L&T / ABB / Schneider)
S&F for MCCB 160 Amps, 25 KA 4-Pole type, with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete all as specified and directed. Make : (Legrand / L&T / ABB / Schneider)
S&F for MCCB 200 Amps capacity 4 pole 25 KA with fixed magnetic & adjustable (80% - 100%) thermal release all as specified and directed.(Legrand/L&T/ABB/C&S)
S&F for MCCB 250 Amps capacity 4 pole 25KA breaking capacity with fixed magnetic & adjustable (80% - 100%) thermal release all as specified and directed.(Legrand / L&T / ABB / Schneider)
Supply and fixing for on load change over switch 200 Amps 415 Volt 4 pole after and including taking down old unserviceable one complete all as specified and directed. Make : L&T /Havells/ HPL (Socomec)
Supply and fixing for on load change over switch 250 Amps 415 Volt 4 pole after and including taking down old unservoceable one complete all as specified and directed. Make : L&T /Havells/ HPL (Socomec)
Supply and fixing for on load change over switch 320 Amps 415 Volt 4 pole after and including taking down old unserviceable one complete all as specified and directed. Make : L&T /Havells/ HPL (Socomec)
Supply and fixing for on load change over switch 400 Amps 415 Volt 4 pole after and including taking down old unserviceable one complete all as specified and directed. Make : L&T /Havells/ HPL (Socomec)
S & F for outdoor type floor mounted bus bar Chamber made 3.0 mm thick M.S. sheet duly painted with powder coated paint (RAL7032 Siemens Grey) having 4 Nos of insulated aluminium bus bar of 200 A rating and size 800mm(w)x800mm(H)x400mm(D) complete with hinged single door in both front and rear side (with locking arrangement), 4 side sloped roof and 600mm long M.S Angle (50x50x6mm) leg, earthing termination bolt etc. complete all as specified and directed.
S & F for indoor type wall mounted bus bar chamber made 2.0 mm thick M.S. sheet duly painted with powder coated paint (RAL7032 Siemens Grey) having 4 Nos of insulated aluminium bus bar of 200 Amps rating and overall sizeof Bus Bar Chamber 900 mm(w) x 600 mm(H) x 300 mm(D) complete with hinged single door in front side only (with locking arrangement), earthing termination bolt, gland Plate at bottom side etc. complete all as specified and directed.
S&Ffor of synthetic polymer insulation mat of electrical grade (suitable for HT11 KV , ISI Marked), 3.0mm thick, duly laid on the floor in front / rear of Panel board, by providing adhesive, all as specified and directed.
M& L for reparing and painting of feeder pillar / LT panel board as under :-
Supply and fixing for MS sheet for feeder pillar for Roof or for Panel Board Door by cutting into required size and shape, moulding, Welding, drilling etc. as replacement of old worn out sheets including painting with two coats of existing shades of synthetic enamel paint over a coat of red oxide metal primer all as specified and directed. Note : Thickness of the new sheet shall have to be same as per existing one.
Replacement of capsule type M.S. door hinges for feeder pillar / panel board duly fixed by welding after removing the old unserviceable hinges
Replacement of castle type door locks for feeder pillars / panel boards as per existing one
Replacement of old unserviceable aluminium lugs/ thimbles of sizes as required on ground complete by crimping and wrapped with insulation tape complete all as specified and directed.
Replacement of DMC / SMC / Ebonite Cable Connector 3 or 4 way suitable for 1100 volt grade all as per existing type / Current Rating etc. complete all as specified and directed.
Replacement of aluminium bus bar of any size with necessary drilling and providing suitable size & colour heat shrinkable type PVC tape all as specified and directed.
Painting in situ of feeder pillars (for external surfaces only) with two coats of 1st quality synthetic enamel paint after cleaning of existing surface and removing of all loose darts and greasy spots and filling of cavities by providing putty all as specified and directed. Note : Painting to be done either by using spray painting machine or by using roller.Brush shall not be used.
Tirupati Buildcon Pvt. Ltd.
ELECTRO FREEZE
KWALITY CONSTRUCTION
BHARUKA ENTERPRISES
ARATI TRADING CO
NARSINGHANI COSTRUCTION CO
RBS Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .