| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹34.5 L+₹3.0 L (9.67%)Rejected-Finance 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹35.4 L+₹4.0 L (12.7%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹35.5 L+₹4.1 L (13.0%)Rejected-Finance 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹37.7 L+₹6.3 L (20.0%)Rejected-Finance KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
27 Dec 2024, 6:00 pmClosed
Maj Mathew M Shepherd
GE (WEST) MATHURA
DISILTING OF RADIAL WELL, MAINT OF RADIAL WELL, SUMP WELL AND ALLIED WORKS UNDER GE WEST MATHURA
2024_MES_687445_1
8300/1277/E8
Open Tender
Civil Works - Water Works
Item Rate
120 days
GE (WEST) MATHURA
AS PER NIT
10 documents required · 10 mandatory
₹500
GE (WEST) MATHURA
₹70,000
Yes
7 Feb 2025
6 Dec 2024
3 Jan 2025
6 Dec 2024
27 Dec 2024
20 Dec 2024
Amount
Taking out and lifting old cast iron sluice valve from a radial well of size upto 300 mm dia complete all as specified and directed. Note : (a) Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account. . (b) All the T&P required including oxygen cylinder, under water gas gutter and water pump for bailing out water and restriction of water supply during work will be arranged by contractor and rates for the same included in the quoted rates.
Supply & fixing and testing in replacement Cast iron Rising spindle sluice valve with iron wheel flanged ends including nut and bolts as per IS 14846 Body Cover-CI IS:210, Gr FG260 Door CI IS:210, Gr. FG260 Body ring-Bronze IS:318 Gr. LTB2 Door Face Natural Rubber Hinge Pin-SS ASTM A276 Type 410 Fastners-CS IS:1367, CL-4.6/4.0 Gasket Natural Rubber Flange Drilling - IS:1538 PN 1.6 of size 300 mm complete all as specified and directed by Engineer-in-charge. Note : Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account.
Supply & laying in replacement cable, 1100 volts grade heavy duty with XLPE insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 120 Sqmm x 3.5 core size including fixing in Open with the help of saddles and nut bolt of suitable size all as specified and as directed. Note : MS saddle, nuts and bolts will be measured and paid seperately under respective item of BOQ.
M&L MS work in support over bridge base guarder by fabricated structural steel chequered plate 6mm thick conforming to IS - 3502 and mild steel Fe 410-W(Gde-E- 250) sections & fabrication for support for roller bearing made up of upto 10mm thick MS plate as per site requirement including welding, bending cold or hot drilling holes including nut, bolts any shape and size as directed or indicated including two coats of enameled paint after one coat of zinc chromate primer all as specified and directed.
Labour and T&P for desilting of Radial well manually and removing silt/sand from not more than 50 mtr depth from the bottom slab and removed/disposed off to a distance of exc 250mtr but n. exc 500mtr , turning ON/OFF water without damage of existing plant and machinery as per time requirement and as directed by Engineer-in-Charge. Note: (i) Contractor will arrange Desilting pump and all T&P as required on site to complete the work. at his own cost. (i) Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account.
M&L for cleaning the Radial pipe of 300 mm dia max length upto 50 metre diagonally by Running Diesel Engine driven Air compressor of not less than 20 PSI Pressure Jet for compressed air development and cleaning the existing radial pipe without damaging the same pipe, size of air line should be minimum 65mm complete all as specified and directed. Note: (i) Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account. . (ii) Disilting meterial obtain under cleaning of radial pipes will be measured and paid under BOQ item No. 05.00 above. (iii) Proper register/logsheet shall be maintain for running of compresor duly signed by contractor and Eng-in-charge every day.
M&L for bailing out muddy water from radial well by running sludge / disilting pump of 100 HP capacity required during of radial well complete all as specified. Note : (i) Extra water during cleaning of radial well will be pumped by same disilting / sludge pump. (ii) Contractor will make arrangement to install pump and make connection for pipeline and electric cable for the running of pump electrically will be provided on chageable basis. (iii) Only 04 Hours will be provided to work in a day time. (iv) Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account. (v) Proper register/logsheet shall be maintain for running of sludge /disilting pump duly signed by contractor and Eng-in-charge every day.
M&L for dismantling of MS channel, MS round / square bars, MS framed structure with or without plates completely alongwith nuts and bolts from radial well by cutting with the help of gas cutter without disturbing the pipes and concrete structure complete all as specified.
M&L framed work MS channels with or without plates, square bars/round bar 10mm, grills, gratings etc with ends of bars shouldered and / or riveted into spikes, framed guard bars, barred iron doors, ladders, framed balusters walk ways railing frame work of ceiling etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for MS saddle 40 mm wide and 5 mm thickness bend in suitable shape and size to cover a diameter of 40mm alongwith suitable size carbon steel nut and bolts fixed in bridge to hold LT cable duly painted with two coat rubber paint complete all as specified and directed.
S&F in replacement GI pipe 40 mm dia in heavy class over a sluice valve spindle of size 300 mm to work like a spindle for opening and closing of a sluice valve from top portion of radial well including connecting items required for fixing GI pipe with sluice valve spindle complete all as specified and directed. Note : (i) Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account.
DEVI DAYAL CONSTRUCTION CO (BID ID -3199882)
LOKESH ELECTRICAL (BID ID -3197464)
M/S A.K. ENGINEERS (BID ID -3199903)
M/s R L PAREEK (BID ID -3199708)
Karman Infra Projects (BID ID -3199959)
M/S S S CONSTRUCTION (BID ID -3200022)
M/S United Builders (BID ID -3200059)
M/s M S CONSTRUCTION (BID ID -3200034)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .