Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC 27 C DPP ROAD KOLKATA 700047 | KOLKATA | SOUTH 24 PARGANAS | WEST BENGAL | 700047 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹11.5 L+₹30,782 (2.75%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance higher rate quoted | |
| 3 | L3₹12.2 L+₹97,887 (8.74%)Rejected-Finance 24A RABINDRA SARANI KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance higher rate quoted | |
| 4 | L4₹12.2 L+₹1.0 L (8.95%)Rejected-Finance 127 E MUKTARAM BABU STREET KOLKATA 700007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L4 | Rejected-Finance higher rate quoted | |
| 5 | L5₹13.0 L+₹1.8 L (15.9%)Rejected-Finance 30 8 ANDUL 1ST BYE ZONE HOWRAH 711109 | HOWRAH | HOWRAH | WEST BENGAL | 711109 | L5 | Rejected-Finance highest rate quoted |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
2 Dec 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE II CKHED
P 12 CIT Road 1st floor KOLKATA 700014
Electrical Installation Work of treatment room in the Brach therapy OT Complex in the 2nd floor of the new Linac Building within the Compound of NRSMCH Kolkata Electrical Installation Work
2020_WBPWD_305342_1
WBPWD/EE-II/CKHED/NIT-11/20-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
NRSMCH
as per NIT
4 documents required · 4 mandatory
₹28,000
P 12 CIT Road 1st floor KOLKATA 700014
19 Mar 2021
13 Nov 2020
4 Dec 2020
13 Nov 2020
2 Dec 2020
25 Nov 2020
23 Nov 2020
180 days
Amount
S&F 8 way Vertical TPNDB with MCCB incoming & TP/SP outgoings, as follows with vertical type busbar system, in SS enclosure (IP-43) double door comprising of neutral link incl. & provision for earthing attachment, concealed in wall incl. interconnection with suitable size of copper wires and earthing attachment, with cable entry Box at both ends, as per direction of the EIC. Incoming - 415V 25KA 160A FPMCCB (1 no) Outgoing - 10KA 63A TPMCB - (8 no) [Make : Legrand]
S&F 415V 6 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incoming - 415V 63A FPMCB isolator(1no) Outgoing - 10KA 6-32A SPMCB-(18 nos) [Make : Legrand]
S&F 415V 2+12 way double door SPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incoming - 220V 40A DPMCB isolator(1no) Outgoing - 10KA 6-32A SPMCB-(12 nos) [Make : Legrand]
Supplying and fixing of 2 pole 32A MCB SS enclosure with IP- 20/30 protection, powder coated provision for housing incl. S&F Two pole (2P) MCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachment, as per direction of the EIC. [Make : Legrand]
Supply & Fixing 240 V, 4 nos 6/16 A, 3 pin Modular type plug socket (Make- Legrand, Arteor/Myrius-Colour Black) with 4 nos 6/16A Modular type switch, without plug top on 2 row 12 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connection, as to GS.
Supply & Fixing 240 V, 16 A -2 nos, 3 pin Modular type plug socket (Make- Legrand, Arteor/Myrius-Colour Black) with 16 A -2 nos Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc, as to GS.
Supply & Fixing 240 V, 16 A - 1no and 6 A - 3 nos, 3 pin Modular type plug socket (Make- Legrand, Arteor/Myrius-Colour Black) with 16 A - 1no and 6 A - 3 nos, Modular type switch, without plug top on 2 row12 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per directed by EIC
Supply & laying of 1.1KV single core stranded FRLS PVC insulated & unsheathed copper wire (RR Kabel/Finolex/Gloster) in 19/25 mm dia polythene pipe after cutting channel of suitable size, concealed in wall, incl. mending good the damages.
a) 4x126/0.4(16 sqmm) + 2x80/0.4 (10 sqmm) [VTPN to TPNDB]
b) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC (AC mc)
c) 2x6sqmm + 1x4sqmm [TPNDB to SPNDB]
d) 2x4sqmm + 1x2.5sqmm [for AC mc.]
e) 2x2.5sqmm + 1x1.5sqmm [for Power plug/Computer]
f) 3x1.5sqmm
Supply & laying of 1.1KV single core stranded FRLS PVC insulated & sheathed and unarmed copper cable (RR Kabel/Finolex/Gloster) in prelaid raceways.
a) 3x10 sqmm
Finising the end of above PVC insulated & unsheathed copper wire.
a) 3x10 sqmm
b) 4x126/0.4(16 sqmm) + 2x80/0.4 (10 sqmm)
c) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
d) 2x6sqmm + 1x4sqmm
e) 2x4sqmm + 1x2.5sqmm [for AC mc.]
f) 2x2.5sqmm + 1x1.5sqmm
g) 3x1.5sqmm
Supply of 4 core 240 sqmm cable of 1.1KV grade, Al./Ar. (Make: Gloster/KEI/Havells/Polycab) on following manner as directed by EIC.
Laying of 4 core 240 sqmm cable of 1.1KV grade, Al./Ar. on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of 4 core 240 sqmm cable of 1.1KV grade, Al./Ar. in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of 4 core 240 sqmm cable of 1.1KV grade, Al./Ar. Through existing covered masonry trench incl. taking out RC covers,setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand
Supply & Laying of cable of 1.1KV grade, Al./Ar. XLPE,cable on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting (Make: Gloster/KEI/Havells/Polycab), as directed by EIC.
a) 4 core 70 sqmm
S&F compression type cable gland complete with brass gland, bursh ring & rubber ring for dust & moisture proof entry of 1.1 KV 4 core following size XLPE/A cable, incl. finishing the end with sockets, by crimping method ,as directed by EIC.
a) 4 core 70 sqmm
b) 4 core 240 sqmm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (RR Kabel/Finolex/Gloster), partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Make- Legrand, Arteor/Myrius-Colour Black) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed], as to GS. a) [Average run 10 mtr]
b) [Average run 11 mtr]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (RR Kabel/Finolex/Gloster), in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Make- Legrand, Arteor/Myrius-Colour Black) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works., as to GS. a) On Board
Supply of fully diffused recessed mounted 2'x2' sq, LED luminaire high transmitive diffuser, as per direction of E.I.C. [Make: Philips make cat no. RC380B LED36S-6500 G4 L60 W60 PSU OD]
Fixing of 2'x2' square LED luminaries with false ceiling cutting and other accessories, as directed by EIC.
S & F of ceiling suspended downlight LED fittings [make- Philips Cat no DN395B 20S-6500 PSU WH] directly suspended from the ceiling incl. connecting the length of PVC insulated wire and mending good damages to original finish and painting as directed by EIC.
Supply & Installation of single phase AC control timer box with powder coated paint on angle iron frame on wall by MS fastener consisting of the following items:- i)10+2 way double door SPN DB(L & T)-- 1 no. ii)2 pole 32A MNX power contactor(L & T) --- 1 no. iii)25A DP MCB (L & T) --- 1 no. iv) Add on auxilliary contact block(1 NO+ 1 NC) --- 1 no. v)40A capacity 3 way AC/DC Epoxy Terminal block --- 1 no. vi)Analog timer of 24 hr capacity (GIC/L & T) --- 1 no. vii)LED indicating lamp (ESBEE make) --- 2 nos. viii)3 way Toggle switch (ON-OFF-ON) --- 1 no. ix) Proper interconnection arrangement with 4/2.5 sq mm PVC cu wire maintaining colour code with proper socketing & taping.
Supply & Fixing of 3 phase AC timer control box with powder coated paint on angle iron frame on wall by MS fastener consisting of the following items:- i)14+2 way double door SPN DB(L & T)-- 1 no. ii) 4 pole 63.A MCX power contactor(L & T) --- 1 no. iii) 63A 4P MCB (L & T) --- 1 no. iv)Add on auxilliary contact block(1 NO+ 1 NC) --- 1 no. v) 100A capacity 4 way AC/DC Epoxy Terminal block --- 1 no. vi) Analog timer of 24 hr capacity (GIC/L & T) --- 1 no. vii) LED indicating lamp (ESBEE make) --- 3 nos. viii) 3 way Toggle switch (ON-OFF-ON) --- 1 no. ix) Proper interconnection arrangement with 6/4 sq mm PVC cu wire maintaining colour code with proper socketing & taping.
Supply & laying of GI raceways (height 38 mm) in floor suitable for drawing PVC copper wire /cable as required complete with all accessories after necessary cutting, laying & allied works and mending good damages as per direction of EIC.
150 mm X 38 mm - 1 compartment (Make- Legrand- 6895 03)
75 mm X 38 mm - 1 compartment (Make- Legrand- 6895 01)
Supply & fixing of GI fixing bracket for fxing raceways on the floor as per direction of EIC.
150 mm X 38 mm
75 mm X 38 mm
Supply & installation of height adjustable junction box 65-90mm for direct access to cables/wires as required from the raceway with all accessories like base and cover plate etc as per direction of EIC.
150 mm X 150 mmX 65-90 mm (Make-Legrand- 6896 10)
75 mm X 75 mmX 65-90 mm (Make-Legrand-)
Supply & installation of riser for 150 mm raceway with all accessories like base and cover plate etc as per direction of EIC. (Make- Legrand)
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
Electromech Engineers Co-Operative Society Ltd.
STANDARD BUILDERS
RAMKRISHNA ELECTRIC
MAA TARA ELECTRO ENTERPRISE
stage.html
html • 0.05 MB
technical_572346.pdf
PDF • 0.60 MB
techsummary_572346.pdf
PDF • 0.08 MB
finance_572346.pdf
PDF • 0.07 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_572346.pdf
PDF • 0.08 MB
WO.pdf
PDF • 0.77 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .