Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L1 | Accepted-AOC QUOTED AMOUT REASNABLE | |
| 2 | L2₹15.1 L+₹2.0 L (15.2%)Rejected-Finance | L2 | Rejected-Finance QUOTED AMOUNT IS HIGHER THAN L1 BIDDER | |
| 3 | L3₹16.9 L+₹3.8 L (28.9%)Rejected-Finance | L3 | Rejected-Finance QUOTED AMOUNT IS HIGHER THAN L1 BIDDER | |
| 4 | L4₹17.7 L+₹4.6 L (35.0%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L4 | Rejected-Finance QUOTED AMOUNT IS HIGHER THAN L1 BIDDER |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
26 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ARVIND KUMAR SHARMA, SE, CWE (AF) PANAGARH
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO BIRUDIAH DIST BURDWAN WEST BENGAL PIN 713148
REPAIR AND MAINT OF STEP DOWN UP TRANSFORMER VCBs OF 33/11 KV POWER HOUSE AND OTHER CONNECTED WORKS AT AF STN SINGARSI UNDER AGE (I) AF SINGARSI
2022_MES_559361_2
82379/SING/e8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STATION SINGARSI
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE(I) AF SINGARSI
₹36,000
Yes
9 Feb 2023
6 Dec 2022
2 Jan 2023
6 Dec 2022
26 Dec 2022
12 Dec 2022
Amount
Note : Prior to commencement of the subject works, the contractor needs to submit valid Electrical License in the name of himself/them self or Agreement with agency having valid Electrical License alongwith Agency's Electrical License to the Accepting Officer for his approval through GE. In absence of such documents, no work will be executed at site and to be treated as defaulter on the Contractor's part . In addition, Supervisor for execution of electrical works employed by the Contractor shall posses Supervisory Certificate of competency issued by concerned State Govt/Union Territory and the Worker/Tradesman for execution of Electrical Works must hold necessary permit issued by concerned State Govt/Union Territory.
Dismantling steel tubular poles 11 mtr long or struts, any size including connected old ACSR Conductor complete all as specified and as directed .
Supply and fixing for steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP 55, 11 metres long including two coats of aluminium paint over a coat of red oxide primer after preparation of surfaces complete all as specified and as directed. Note: Excavation, filling, and foundation concrete will be measured paid separately.
M&L for painting of transformer 63 KVA to 500KVA capacity of transformer, applying two coats of synthetic enamel paint of grey colour by spraying including preparation of old surfaces, removing & cleaning of oil/greasing complete all as specified and as directed.
Supply and fixing in replacement of switch air break, HT 11 KV gang operated vertical/horizontal type triple pole mechanically operated, mounted on 09 insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps as per IS-9921 including taking down old unserviceable GOD complete all as specified and directed
Supply and fixing in replacement of lighting arrester expulsion type suitable for 11KV complete with all fitting transmission class, discharge capacity of 65 KA including taking down old unserviceable switches complete, all as specified & directed by Engr-in-charge.
Supply and fixing pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 150 mm height and 150 mm dia for 11 KV grade including taking down unserviceable pin type insulator complete all as specified and directed.
Supply and fixing loop type insulator (for stay assembly) porcelain vitreous white, brown or green, large size, with overall dimensions 90 x 140 mm, clearance of hole 25.5 mm including taking down old unserviceable loop type insulator complete, all as specified & directed by Engr-in-charge.
Supply and filling of transformer oil and topping up the oil level of transformers complete all as directed by Engr-in-charge. Make- POWER/ UNIVERSAL/SAVITA/INSOLE Note: Transformer oil shall be supplied in sealed drums and shall conforming to IS -335.
Dehydration/Filtration of Transformer Oil by means of Centrifugal Filtration Plant to achieve the specified Di-electric Strength complete all as specified and as directed. NOTE : Transformer Oil to be use for TOP UP shall be Measured and Paid for separately.
Supply and fixing Anti-climbing device, spikes type fabricated out of flat iron 40x6mm and M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole and painting one primer coat, one under coat and one finishing coat of paint including taking down old unserviceable anti climbing device complete all as specified and directed.
Supply and laying cable duct cover , size as per existing ducts of MS sheet of 8 mm thick for protection of HT cable line from outdoor Transformer /GOD to indoor VCBs as director by Engineer in charge
M&L for calibration and setting of protection relays of any make fitted on 11 KV VCBs to ensure NO ERROR including setting for each fault over current with trip time delay in accordance to feeder load and other parameters of site including synchronizing of the same with MRS/Sub Stations setting to ensure that fault shall not travel to nearest source feeder including minor repairs, replacement of wiring etc, if required all as directed by Engineer- in- Charge
S&F Hooter system operating voltage 24V/220V, AC/DC for 4 Nos VCB parallel operating system complete with testing including all accessories such as contactor, re-set switch and cut- out complete wiring etc including taking down old unserviceable one, and as directed by Engr-in-charge.
Shifting of Transformer of any size from any location to another location with useful mechanism complete all including disconnecting/ reconnecting HT/ LT line as directed by Engr-in-Charge
Taking shut down , disconnecting incoming, outgoing cables, from 11KV VCB Panel of capacity up to 630/800 Amps by opening HT bus bar chamber for cleaning the bus bar chamber, bus bars, HT insulator with CRC including insulating the bus bar & HT Insulator with suitable insulation sleeve as per colour code complete after carried out complete inspecting the wiring of relays servicing , depitting /decarbosing of contacts including greasing/ lubricating of revolving assy & varnishing with drying of CTs/PTs in VCBs & testing of complete VCBs system of its mechanical & electrical system. reassembling complete HT panel board with VCB and testing with suitable testing instruments for smooth functioning complete with remote operation all as specified & directed by Engr-in-Charge. NOTE : 1. The quoted rate shall deemed to include for the cost of minor parts required for making the VCBs fully functional. 2. Required parts as below to be replaced shall be measured & paid separately. 3. Labour for replacing supply only item shall be deemed to be included in quoted rates.
Supply only Motor Cut off switch suitable for 11 KV VCB. Make- Areva/Schneider/CG.
Supply only Shunt Trip Coil, operating voltage 24 Volts DC suitable for 11 KV VCB gas breaker. Make- Areva/Schneider/CG.
Supply only Ratchet wheel Assembly suitable for 11 KV VCB Make- Areva/Schneider/CG.
Supply only replacement control fuse 15A HRC with base carrier suitable for 11KV/33KV , 630/800 Amps shall be matching with the existing make of VCB or as approved by Engr- in-charge.
Supply only big gear suitable for 11 KV VCB. Make :- CG/Areva/Schneider
Supply only trip catch assy suitable for 11KV VCB. Make- CG/AREVA/SCHNEIDER
Supply only Control wiring with size of 2.5 sqmm 8 core, PVC copper cable for indicating lamp , control protection system etc suitable for 11KV/33KV , 630/800 Amps shall be matching with the existing make of VCB or as approved by Engr- in-charge.
M&L for replacement, Earth fault relay (inverse) type CDG, CT sec-5, range 2.5-10A , 50 HZ suitable for 11KV, 630/800 Amps shall be matching with the existing make of VCB or as approved by Engr- in-charge.
M&L for replacement Power Pack , Input : 110V AC , 3RH/1RH , output :110V DC Filtered/Unfiltered (+) , cap : 200VA suitable for 11KV, 630/800 Amps shall be matching with the existing make of VCB or as approved by Engr- in-charge.
M&L for replacement Over current relay (inverse ) type CDG, CT sec -5 Amp, range: 1-4A , 50HZ for 11KV , 630/800 Amps shall be matching with the existing make of VCB or as approved by Engr- in-charge.
M&L in replacement of spring charge motor assembly with Gear Assembly operating voltage 220 V AC/ DC suitable for 11 KV VCB of Areva/CG /as existing on site complete with required material and as directed by Engr-in-charge.
Supply & fixing HT Jumper not more than 2 m long in repair /replacement on existing OH circuit / two Pole / four Pole Structure etc including ACSR Conductor (Weasel) using PG clamp/lugs, fasteners etc as per site requirement.
M&L for replacement Resin cast current transformer indoor type of ratio 120-60/5A, class 1.0, 5P10 , burden :15 VA, insulation level : 28 KV/75 KV shall be matching with the existing make of VCB or as approved by Engr- in-charge.
Disconnecting Potential Transformer from incomer VCB for repairing/replacing of 3 phase copper winding & testing complete with load testing as specified by Engr-in-Charge.
Supply and fixing in replacement stay assy set complete comprising of galvanized steel bow 14mm dia 40 cm long, stay rod 16mm/20mm dia 1.8 mtr long galvanized thimble, and shown in electrical plate No 1 of SSR part -1(2009) including taking down old unserviceable stay assembly complete all as specified and directed by Engineer-in-Charge. Note: (i) Excavation and earth work, PCC, stays strand, PCC stay clamps and loop type insulator shall be deemed to be included in the unit rate quoted for the items.
Supply and fixing in replacement cross arms, bracings, supports, clamps, back plate fabricated from structural steel sections such as channels, angles, flat iron including 16mm dia bolts, nuts, washers, welding, bending, cold or hot drilling holes for bolts/insulators in any shape and size as directed and inclusive of one priming coat of red oxide zinc chrome, one under coat and one finishing coat of aluminium paint complete including taking down old unserviceable cross arms complete all as specified and directed by Engineer-in-Charge.
M & L for insulated matting chequered suitable for 11 KV rating as per IS 15652-2006, of size 2Mx1Mx2.5mm thick all as specified by Engr-in-Charge.
M&L for maintainance of 33 KV (yard) power grid bus bar structure at MRS 33/11 KV alongwith Sub-station No 1, scratching out old bubbled paint finishing the surface with two coats of synthetic enamel paint over a coat ofred oxide primer to steel tubular pole/PCC pole/MS structures including cross arms breachings, clamps etc. including 3 strips of 30cm width red painting as directed by the Engineer-in-Charge complete all as directed by the Engr-in-Change.
M&L for painting of steel structure along with bracing , supports, nut & bolt & clamps etc complete with one coat of aluminium paint after preparation on of surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement aluminium conductor steel reinforced (ACSR) conductor for HT over head line of size as per existing including taking down old unserviceable complete all as specified and directed by Engineer-in-Charge.
M & L in replacement for guarding cradles, rectangular, fabricated with galvanised steel wire 3.15mm or 4mm dia including taking down of old unserviceable steel wire complete all as specified and directed by Engr-in-Charge.
M&L for including restreching / tightening of HT over head line (ACSR Conductor all 3 phases ) of any type including opening out binding wire from pin/disc insulator and rebinding the conductor with insulator with 14 SWG binding wire complete all as directed by Engr-in-Charge.
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor (multistranded), 95 Sqmm 3 core , 11000 volts grade connected with suitable size brass cable gland and aluminium lugs of required size, laid in trenches or passing through pipes including testing after laying, including taking up old unserviceable cable complete of following size all as specified and directed by Engineer-in-Charge.
Supply and fix cable joint kit for 11 KV grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as specified and directed by EIC.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed.
All as per item No 41.00 above but in road cutting/ hard standing etc including making good disturbed surfaces to match with original complete all as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft /loose soil or hard/dense soil all as specified and directed by Engineer-in-Charge. .
Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point all as specified and directed by Engineer-in-Charge. .
M&L PCC 1:4:8 type D 2 (using 40mm graded stone aggregates) as in foundation of electric poles etc all as specified and directed.
M&L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation of stay assembly complete all as directed
M&L PCC 1:2:4 type B 1 (using 20mm graded stone aggregate) as in benching / copping around poles including use of necessary form work complete all as directed.
Supply and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40 mm including taking down old unserviceable cable cover complete all as specified and directed by Engineer-in-Charge.
Supply and laying new dry river sand laid in trenches 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering complete all as specified and directed by Engineer-in-Charge. Note:- Punned quantity will be measured paid at this item.
M & L for 40 mm graded stone aggregate for laying to cover the area of MRS, transformer and GOD all as specified and directed by Engineer-in-Charge.
M & L for Silica gel ( deep Sky blue colour) for replacement in breathers of transformers all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement HT porcelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for 63 KVA to 250 KVA ratings after shutdown of existing transformer complete all as specified and directed by Engineer-in-Charge.
All as per item No. 52.00 here -in-before but 315 KVA to 500 KVA ratings.
Supply and Fixing in replacement LT porcelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for 63 KVA to 250 KVA after shutdown existing transformer as specified by Engr-in-Charge.
All as per item No. 54.00 here -in-before but 315 KVA to 500 KVA capacity.
Supply and fixing gasket as per existing sizes suitable to arrest leakage of transformer oil as directed by Engr-in-Charge
M&L for straight through heat shrink cable jointing kit for 11KV ( Earthed ) grade cable for type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick burried in a pit to a depth of 2.25mtrs below ground level with top edge of earth plate at a depth of not less than 1.50 meters below ground level, earth plate packed on all sides with charcoal dust mixed with salt to a thickness of 15cm, connected with earthing lead of 32mm x 6mm galvanised iron strip, watering pipe 20mm dia light grade and water filling funnel and mess complete all as shown in plate No 4 of MES Schedule part II to the earthing test point, including PCC Work complete including protection pipe 40 mm dia light grade all as specified and directed by Engr-in-Charge. (Note :- The earth strip/lead up to 7.5 m shall be deemed to be included quoted unit rate.)
M&L in replacement for Earthing complete with copper earth plate electrode of size 600x600x3.15mm thick burried in a pit to a depth of 2.25mtrs below ground level with top edge of earth plate at a depth of not less than 1.50 meters below ground level, earth plate packed on all sides with charcoal dust mixed with salt to a thickness of 15cm, connected with copper earth strip of 32mm x 6mm, connected with bolts, nuts, check nuts of copper, watering pipe 20mm dia light grade and water filling funnel and mess complete all as shown in plate No 4 of MES Schedule part II to the earthing test point, including PCC Work complete including protection pipe 40 mm dia light grade all as specified and directed by Engr-in-Charge. (Note :- The earth strip/lead up to 7.5 m shall be deemed to be included quoted unit rate.)
Disconnecting Transformer outdoor/indoor type 11KV/433 Volts supply system electrically both side, earth terminal and taking down carefully from pole / platform mounted on PCC foundation etc. and carrying to workshop for repair for 63KVA to 250 KVA capacity complete all as specified and as by Engr-in-Charge.
M&L for rewinding of Transformer HT coil with super enamelled/paper coated copper wire of existing gauge including all associated insulting materials such as separators etc. complete varnishing heating including disconnecting of top cover, decanting of transformer oil, storing the same in suitable container, disconnecting live parts, dismantling bushing, lifting of core assembly, checking the windings, cleaning of cooling tubes, conservator and all internal connections after necessary all repairs and rewinding, assemble the complete transformer and refilling after necessary filtration including all internal connections etc of any type/capacity of transformer all complete as directed by the Engr-in-Charge. Note: filtration of oil shall be measured and paid separatily.
All as per Item No 61 above but for LT winding.
Surface dressing not exc. 15cm deep in soft/loose soil and cleaning away all grass vegetation, saplings, shrubs, brushwood, undergrowth roots, and trees not exc. 30cm girth in surrounding of transformers, LT panels, 02/04 pole structures etc. at various sub-stn/ E/M installations and removing rubbish upto a distance exc. 200m but n.exc. 250m outside of periphery of the area under clearance complete all as directed by the Engr-in-Charge.
M&L for loose filling of stone aggt of gauge 40mm to 80mm deposited, spread and levelled in layers n.exc. 15cm thick complete all as directed by the Engr-in-Charge.
Bharti Electrical Point
M/S AMARNATH AGARWALLA
Neha Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .