EE ETD ROBERTSGANJ
220 KV S S Chapaka Robertasganj
TESTING OF TRANSFORMER OIL OF VARIOUS 220 132 KV TRANSFORMER 132 33 KV TRANSFORMER INSTALLED AT DIFFERENT 220 132 KV SUBSTATION UNDER ETD ROBERTSGANJ
2024_UPTCL_967911_2
03/2024-25/ETD-RBJ
Open Tender
Electrical Works
Fixed-rate
30 days
ROBERTSGANJ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ETD
₹2,000
ETD ROBERTSGANJ
5 Dec 2024
13 Nov 2024
30 Nov 2024
13 Nov 2024
29 Nov 2024
13 Nov 2024
13 Nov 2024
Amount
Collection Testing & Analysis of T/F oil as per IS: 1866 & IS:10953 at 220 KV S/S Robertsganj
1- Water Content (PPM)
2- Dielectric Dissipation Factor (Tan Delta)
3- Dissolved Gas Analysis (07 gases) Methane, Ethylene, Ethane, Acetylene, Hydrogen, Carbon Mono Oxide & Carbon Dioxide
Collection Testing & Analysis of T/F oil as per IS: 1866 & IS:10953 at 132 KV S/S Robertsganj
1- Water Content (PPM)
2- Dielectric Dissipation Factor (Tan Delta)
3- Dissolved Gas Analysis (07 gases) Methane, Ethylene, Ethane, Acetylene, Hydrogen, Carbon Mono Oxide & Carbon Dioxide
Collection Testing & Analysis of T/F oil as per IS: 1866 & IS:10953 at 132 KV S/S Dalla
1- Water Content (PPM)
2- Dielectric Dissipation Factor (Tan Delta)
3- Dissolved Gas Analysis (07 gases) Methane, Ethylene, Ethane, Acetylene, Hydrogen, Carbon Mono Oxide & Carbon Dioxide
Collection Testing & Analysis of T/F oil as per IS: 1866 & IS:10953 at 132 KV S/S Bina
1- Water Content (PPM)
2- Dielectric Dissipation Factor (Tan Delta)
3- Dissolved Gas Analysis (07 gases) Methane, Ethylene, Ethane, Acetylene, Hydrogen, Carbon Mono Oxide & Carbon Dioxide
Collection Testing & Analysis of T/F oil as per IS: 1866 & IS:10953 at 132 KV S/S Pasahi
1- Water Content (PPM)
2- Dielectric Dissipation Factor (Tan Delta)
3- Dissolved Gas Analysis (07 gases) Methane, Ethylene, Ethane, Acetylene, Hydrogen, Carbon Mono Oxide & Carbon Dioxide
Sample Collection charges including sampling container & transportation of sample safely from different substations under ETD-Robertsganj to laboratory .
Shree Heramb Test Lab (OPC) Pvt. Ltd. (BID ID -4750807)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .