Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹54.8 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹61.0 L+₹6.2 L (11.2%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹69.9 L+₹15.1 L (27.5%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹75.8 L+₹21.0 L (38.2%)Admitted-Finance U 38 2ND FLOOR NEAR BABA PALACE PATPARGANJ MAIN ROAD SHAKARPUR LAXMI NAGAR DELHI 110092 | EAST | DELHI | 110092 | L4 | Admitted-Finance | ||
| 5 | L5₹88.0 L+₹33.2 L (60.5%)Admitted-Finance A 6 MANDAWALI UNCHEPAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L5 | Admitted-Finance |
Tender Value
₹96.2 L
EMD Value
₹1.9 L
Closing Date
6 Feb 2026, 3:00 pmClosed
Executive Engineer (Elect.)
EE (E), PWD NES/ M-251, LM Bund Road, Ramesh Park
(SH- Operation of EI and Fans including compound light substation DG set Water supply and dewatering system Fire Fighting and Sprinkler system Lifts Fire Alarm and PA System.)
2026_PWD_285885_1
90/EE(E)/PWD NES ED/2025-26
Open Tender
Electrical Works
Percentage
365 days
DSSSB Building Karkardooma
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.9 L
Yes
11 Feb 2026
30 Jan 2026
6 Feb 2026
30 Jan 2026
6 Feb 2026
30 Jan 2026
Maintenance and up keeping of all the internal electrical installations, compound lights, recording and monitoring of the complaints in general shift on all working day of the week (excluding Sunday and Holidays) as per terms and condition and duty of staff details attach. Wireman- 1 No. General Shift (9:00 AM to 5:00 PM)
Operations & maintenance of 11 KV/415 V substations of 2 x 315 KVA capacity with HTVCB & LT Panels etc. round the clock on all the days of the week (i/c Sunday and Holiday) The job also includes recording of all parameters like HT & LT voltages current. power factor etc. & routine periodical checking & testing as per terms and conditions & inventory and duty staff details attach. c) Round the clock operation & maintenance of 1 x 320 KVA capacity DG sets with AMF panel i/c day to day cleaning & keeping records etc. round the clock on all working days (i/c Sunday & Holiday) as per terms and conditions & inventory and duty staff details attach. Wireman Cum Operator- 3 No.(6:00 AM to 2:00 PM, 2:00 PM to 10:00 PM and 10:00 PM to 6:00 AM) Three Shift Khallasi- 01 No. (9:00 PM to 5:00PM) General Shift
Operation & routine maintenance of Fire Fighting system i/c sprinkler system installed at round the clock on all the days of the week (i/c Sunday and Holidays) as per terms and conditions & inventory and duty staff details attach. e) Running Maintenance and operation of Water Supply pumps & dewatering pumps installed at round the clock on all the days of week (i/c Sunday and Holidays) as per terms and conditions & inventory and duty staff details attach. Fireman Cum Operator- 3 No.(6:00 AM to 2:00 PM, 2:00 PM to 10:00 PM and 10:00 PM to 6:00 AM) Three Shift Khallasi- 01 No. (9:00 PM to 5:00PM) General Shift
Operation and Routine Maintenance of fire alarm system & PA System including panel and all other connected accessories etc. round the clock on all the days of the week (i/c Sunday and Holidays) as per terms and conditions & inventory and duty staff details attach. Fire Alarm Technician - 01 No. (9:00 PM to 5:00PM) General Shift
Operation of 2 Nos. 10 Passengers capacity Kone make lifts in general shift on all the days of the week (excluding Sunday and Holidays) as per terms and conditions & inventory and duty staff details attach. (1) Lift Operator-1 Nos. (9 AM to 5 PM)
Providing Services of 1 No. Peon/Helper in division office for day to day routine work to assist Division staff, to carry Dak to various PWD office/Sub division on all days excluding Sunday & Second Saturday from 9:00 AM to 6:00 PM as per terms & condition attached. (Salary shall be paid strictly as per minimum wages fixed by Delhi Govt. with all benefits like ESI, EPF etc.
Providing services of Security Guard at PWD office Ramesh Park near Laxmi Nagar for round the clock duty on all days i/c Sunday & Holidays as per terms & condition of against -3 Nos.
Providing services of Messenger cum Peon (under Semi-skilled category) having education qualification non-matriculates with minimum 6 years relevant experience in different PWD offices as per directions of Engineer-in-charge.
Comprehensive running maintenance and servicing of WTAC/STAC (1.0/1.5/2.0) TR)/ Water Coolers of different makes and models installed at various places including labour change and replacement of all defective minor parts i/c supplying and charging of R-410A/R-22 refrigerant gas in the compressor in case of leakage (Except replacement of compressor) i/c checking the units oiling, greasing, chemical cleaning of condenser coil, cooling coil i/c replacement of defective parts, Air Filter, running capacitor, starting capacitor, starting relay, thermostat switch, wiring kit, 15/20 Amp Plug tip/Industrial socket, flexible wire and tightening the loose connection, complete as required.
For Summer Season 74 Nos. for 8 Months
For Winter Season 74 Nos. For 4 Months
Supplying and replacement of compressors of following capacities in the split type AC units/WTAC units/ Water Coolers i/c charging the gas, piping (upto 2 mtr) etc. complete as required
1.50 T.R. capacity
2.0 T.R. capacity
Supplying and replacement of PCB of 1.0/1.5/2.0 TR capacity WTAC/STAC i/c dismantling of defective PCB, testing & commissioning etc. complete as required.
Split AC inverter PCB
Supplying and replacement of Cooling Coil of 1.0/1.5/2.0 TR capacity WTAC/STAC i/c dismantling of defective coil testing & commissioning etc. complete as required.
Split AC
Window AC
Supplying and replacement of Copper Condenser Coil of 1.0/1.5/2.0 TR capacity WTAC/STAC i/c dismantling of defective condenser coil testing & commissioning etc. complete as required.
Split AC
Supplying and replacement of Fan Blade of 1.0/1.5/2.0 TR capacity WTAC/STAC i/c dismantling of defective fan blade testing & commissioning etc. complete as required.
Supplying & laying of refrigerant copper pipe of 5/8" & 1/4" size for liquid line of 2.0 TR Split AC with nitrile foam insulation on the complete length of copper pipes from indoor unit to outdoor unit pipe connections, 3 core 2.5 sq. mm copper conductor PVC insulated cable for indoor and outdoor connection and Heavy Duty hard PVC drain pipe of size 25 mm Dia for Split type AC unit including binding/Clamping up to 10 mtr. etc. i/c breaking open wall for pipe outlets & making good the damages wherever necessary complete etc. as reqd.
Dismantling & Re-installation of STAC & WTAC with refrigerant line & MS stand & outdoor Stand with gitti peach etc. as require.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
3 Module
6 Module
8 Module
12 Module
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) 63 A
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
125 A, 16 KA,TPMCCB
200 A,36KA,FPMCCB
250 A,36KA,FPMCCB
400 A,50KA,FPMCCB
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
SITC OF 400 mm dia Wall fan suitable for operation on 230 Volt ± 10%, 50 Hz supply to fixed on wall i/c connection with 1.5 Sq.mm PVC insulated PVC sheathed copper conductor single core cable etc. as reqd.
Supplying, installation, testing and commissioning of heavy duty exhaust fan of 300 mm sweep, 900 RPM confirming to IS 2312/67 complete with louvers and frames in the existing opening including making the hole to suit the size of the above fan, making good the damage, connections, earthing etc. as required.
Supplying, installation, testing and commissioning of PVC exhaust fan of 250 mm sweep, 1250 RPM with louvers and frames in the existing opening including making the hole to suit the size of the above fan, making good the damage, connections, earthing etc, as required.
Supplying, Installation, testing and commissioning of 36 to 40 watt surface/recess mounted LED Luminaries of size 1200 mm (Length) x 300 mm (Width) housing made with white powder coated CRCA sheet metal and polycarbonate diffuser suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency not less than 100 luman per watt. and colour temperature of 5700-6500 K, CRI >80 with APFC driver having power factor > 0.90, THD <20% and efficiency > 85% driver should be IC Compliant, with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable with the help of 4 nos. fastener Hook, Clutch wire and sleeve etc. i/c making connections, testing, commissioning etc. complete as required.
Supplying and fixing of 10 to 12 watt 600 mm long high efficiency LED linear batten Luminaries having aluminium extruded housing and polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor > 0.90, THD <20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 100 luman per watt. and colour temperature of 6500 K, CRI >80 including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable with the help of two nos. fastener Hook, etc. as required.
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt
LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/4000°K/5700°K/6500°K(As per ANSBin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 90 watt
Taking out submersible /mono submersible p/set upto 10 HP rating along with G.I Pipe from existing bore well/ sump with the help of chain and pulley block etc. as reqd. i/c cartage from site to workshop as required.
Lowering of submersible /mono submersible pump set upto 10 Hp rating along with G.I Pipe from existing bore well/ sump with the help of chain and pulley block i/c cartage from workshop to site etc. as required.
Replacement of defective by S.I.T.C of 7.5 HP, Submersible Monoblock pump set, Suc Del. Size 65mmX50mm electric motor suitable for 420 volt, Three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd.
SITC of All in One computer system with following configurations: a) CPU : Intel Core i7 150U (12 MB cache, 10 cores, 12 threads, Up to 5.4 Ghz b) Operating System :- Window 11 Home , Single Language c) Video Card:- NVIDIA @ GeForce@MX570A with 2GB GDDR6 graphics Momory d) Monitor:- 27" Touch FHD, WVA e) Memory :- 16 GB 2x8 GB DDR5, 5200 MT/s f) Storage 1TB, M2, PCle NVMe, SSD g) Stand :- Triangle stand h) Microsoft office :- Microsoft office Home 2024 + Microsoft 365 Basic 1 Year subscription (Make:- DELL Model No. Dell 27 150U (EC27250) or better model or equivalent in HP)
Credit for Dismantle Material
2.0 T.R. capacity compressors, Cooling Coil, Condenser Coil, Fan Blade, PCB
Assorted wire 1.5/4/6 Sq mm
Assorted Box Piano Type, Modular Type switch/ socket & Plate
Assorted Ceiling Fan, Wall Fan & Exhaust fan
Assorted LED Batten
Assorted LED Panel Fitting
Assorted Street Light
Assorted submersible pump 7.5
Assorted MCB 5/32 Amp
Assorted MCCB/TPN/DP/SPN
Assorted 125 A, 16kA, TPMCCB
Assorted 200 A, 50kA, FPMCCB
Assorted 250 A, 50kA, FPMCCB
Assorted 400 A, 50kA, FPMCCB
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.06 MB
BOQ_378381.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .