distribution or control board enclosures ( Distribution board for MCBs)
Molded Case Circuit Breakers (MCCB)
miniature circuit breakers Distribution Or Control Board Enclosures ( Distribution Board For MCBs) ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Reference BIS Specification:13032 yes * Suitable to accommodates specified Number of poles (number) Three Pole MCBs as out going and FP MCB with 3 Protected pole as incoming Three Pole MCBs as out going and FP MCB with 3 Protected pole as incoming No. of Ways (in Number) 8 8 Metalic cover Type MCBs are operable manually without opening of cover (Single door) MCBs are operable manually without opening of cover (Single door) Enclosure category (Degree of Protection) IP-43 IP-43 CONSTRUCTIONAL MCB distribution board for indoor installation yes * 1/6 Copper Bus bar Rating (ampere) 100 Amp. * Minimum Sheet Thickness properly pretreated and stove enameled/Powder Coated (mm) 1.6 mm * Steel Mounting Rail Top Hat as per IS:11039/83 (35mmX7.5mm) Yes * Earth bar Yes * Neutral bar Yes * CERTIFICATIONS Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab to prove conformity to the specification. Yes * Type Test Certificate No. T-2255 Mechanical Testing * Type Test Certificate date 07/06/2016 * Name of Lab NABL * Address of Lab - * Test Report to be furnished to the buyer on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mukesh Shukla 492001
O/o Executive Engineer
(E&M) Public Works Department Sirpur Bhawan Parisar
Raipur. (C.G.) 1 15 Molded Case Circuit Breakers (MCCB) ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Governing Indian Standard specification YES * 2/6 as per IS/IEC:60947 part-2:2003 latest ISI marked NO YES
NO If ISI Marked 'Yes' declare CM/L Number If 'NO' write NA NA * Rated Current (in Ampere) 250A 250A No of poles/Protected poles(PP) 3 Pole 3 Pole Rated Short circuit capacity (in KA) MCCB with RSCB capacity of 10/16/25/35 KA tripping range MCCB with RSCB capacity of 10/16/25/35 KA tripping range Breaking current (in KA) 35 KA 35 KA Rated Voltage 240/415 Volt 50 Hz AC 240/415 Volt 50 Hz AC CERTIFICATIONS Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES * Test Report Number (Must declare) T-2255 * Test Report Date (Must declare) 07/06/2012 * Name of Lab (Must declare) NABL * Address of Test Lab (Must declare) SURAT
GUJARAT * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mukesh Shukla 492001
Raipur. (C.G.) 2 15 Molded Case Circuit Breakers (MCCB) ( 6 ) Technical Specifications 3/6 * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Governing Indian Standard specification as per IS/IEC:60947 part-2:2003 latest YES * ISI marked NO YES
NO If ISI Marked 'Yes' declare CM/L Number If 'NO' write NA NA * Rated Current (in Ampere) 100A 100A No of poles/Protected poles(PP) 3 Pole 3 Pole Rated Short circuit capacity (in KA) MCCB with RSCB capacity of 10/16/25/35 KA tripping range MCCB with RSCB capacity of 10/16/25/35 KA tripping range Breaking current (in KA) 35 KA 35 KA Rated Voltage 240/415 Volt 50 Hz AC 240/415 Volt 50 Hz AC CERTIFICATIONS Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES * Test Report Number (Must declare) T-2255 * Test Report Date (Must declare) 07/06/2012 * Name of Lab (Must declare) NABL * Address of Test Lab (Must declare) SURAT
Raipur. (C.G.) 6 15 4/6 Miniature Circuit Breakers ( 5 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Governing Indian Standard specification IS/IEC 60898-1:2002 Yes * Rated Current (Ampere) 40 A 40 A Instantaneous Tripping Range C C Rated Voltage (Volt) 240 VOLT 240 VOLT No of poles/Protected poles(PP) 3pole with 3PP 3pole with 3PP ISI marking Yes * CM/L No: - * CM/L Validity up to 13.5.2018 * CONSTRUCTIONAL Steel sheet enclosure for MCB of 1.2 mm thickness duly pretreated stove enamelled/powder coated Without * Rated Short circuit capacity (Ampere) 10000 A * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laoratory to prove conformity to the specification for each rating. yes * Test Report number - * Date of issue of Test Report by Laboratory - * Test Report to be furnished to the buyer on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 5/6 1 Mukesh Shukla 492001
Raipur. (C.G.) 5 15