Loading…
Loading…
Tender ID
Tender Value
₹1.6 L
EMD Value
₹4,800
Closing Date
12 Mar 2026, 3:00 pmClosed
DGM (STC-STM) MORENA
O/o the DGM (STC-STM) MORENA
Estimate for New Connection of 01 No 64 KW Non domastic Connection applied from SDE Building BSNL Morena on 11 KV Industrial Feeder at place Dholpur Road Morena under Ganeshpura Zone of (OandM) Dn. Morena-I
2026_MKVVC_488082_1
No. DGM/STC-STM/MRN/works/ E-Tender/ 3926dt- 06.03.2026
Open Tender
Electrical Works
Percentage
30 days
BSNL Morena on 11 KV Industrial Feeder at place
Please refer Tender documents.
3 documents required · 3 mandatory
₹236
₹4,800
Yes
6 Apr 2026
7 Mar 2026
13 Mar 2026
7 Mar 2026
12 Mar 2026
7 Mar 2026
Task Name : 100 KVA DTR
11 KV AB Switch Polymer type 400 Amp with Complete fitting
Erection costo of 11 KV AB Switch Polymer type 400 Amp with Complete fitting
11 KV AL 59 ACS Covered Conductor 78.82 sq.mm along with MVCC accessories as per EN:50397 Calculated for 1 KM Single Phase Feeder, tension/dead/anchoring clamps with piercing connector suitable for MVCC, IPC for CC to CC connection,EN-50397 -P-2
Erection cost o f 11 KV AL 59 ACS Covered Conductor 78.82 sq.mm along with MVCC accessories as per EN:50397 Calculated for 1 KM Single Phase Feeder, tension/dead/anchoring clamps with piercing connector suitable for MVCC, IPC for CC to CC connection,EN-50397 -P-2
11 KV D.O. Fuse Unit Polymer type
Fixing of 11 KV D.O. fuse unit ( Set of 3 No. )
11 KV Strain hardware (T&C type) fittings
11 KV(45KN) Composite Polymer Disc Insulators
Erection cost of 11 KV Disc Insulators with hardware
9 KV Gapless type ( 5KA) Polymer for DTR
Erection cost of 9 KV Gapless type ( 5KA) Polymer for DTR
AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.)
DTR 11/0.4 KV BIS EE-Level-2 100 KVA
Handling & Installation of Distribution Transformer (DTR) on DP, tightening with turn buckles on both sides, poles clamping and boting of base jumpering on HT side (Including hydra charges in urban area and chain pully charges in rural area)
H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-11 mtr. Long = 408.1 kg
Erection cost of material with transportation for H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-11 mtr. Long = 408.1 kg
Three phase Static Energy meters 20-80 Amps.with L.S. & TOD Facility with box
XLPE Cable 1 core unarmoured 150 sqmm Aluminium conductor 1100 Volts
XLPE Cable 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts
11 KV Single pole cut point fitting 100x50x6 mm channel
Erection cost of 11 KV Single pole cut point fitting 100x50x6 mm channel
Aluminium paint
Erection cost of Aluminium paint
Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG)
Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg)
Bentonite compound powder
Bi-metallic clamps Distribution Transformers Bushing
Bi-metallic clamps suitable for 12mm dia stud and 80sqmm AAAC
Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg)
Concreting of Rail / Hbeam supports @0.65 Cmt.per pole including muffing of pole
Erectio cost of Concreting of Rail / Hbeam supports @0.65 Cmt.per pole including muffing of pole
D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel
Erection cost of D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel
D.O.Mounting Channel 75x40x6mm
Eretion cost of D.O.Mounting Channel 75x40x6mm
Danger Boards Enamelled 11 KV
Erection cost of Danger Boards Enamelled 11 KV
Double Gate (2No-2.5'x5x) set of MS angle (25x25x4mm) with mesh & locking
Erection cost of Double Gate (2No-2.5'x5x) set of MS angle (25x25x4mm) with mesh & locking
DTR S/s fencing (37 feet) of 6' with on MS Angle(50x50x6mm) 7No, 7'Height
Erection cost of DTR S/s fencing (37 feet) of 6' with on MS Angle(50x50x6mm) 7No, 7'Height
G.I. STRIP 25X3 MM1
G.I.Pipe 40 mm Dia C grade type
Erection cost of G.I.Pipe 40 mm Dia C grade type
Galvanized nut & bolt with washer
LT distribution box with 1.2 mm thick MS powder coated sheet, 315 A MCB on incoming & 6 no. 250 A HRC fuse base including 200 A HRC fuse , For 200 KVA Transformer
Erection cost of LT distribution box with 1.2 mm thick MS powder coated sheet, 315 A MCB on incoming & 6 no. 250 A HRC fuse base including 200 A HRC fuse , For 200 KVA Transformer
M.S.Nuts with Bolts
Red oxide paint
Erection cost of Red oxide paint
Stone Block/Pre cast block for base pedding(450X450X75MM)
Trans. Belting with 50 X 50 X 6 mm.angle with two cross fixing channels
Transformer mounting Channel (100X50x6 mm.)
Erection cost of Transformer mounting Channel (100X50x6 mm.)
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.63 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Tendernotice_2.pdf
PDF • 7.49 MB
SBDocumentmerged.pdf
Tender Documents • 7.47 MB
BOQ_574900.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .