Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.6 LAdmitted-Finance | -28.00% | ₹4.6 L | L1 | Admitted-Finance |
| 2 | L2₹4.6 LAdmitted-Finance | -27.13% | ₹4.6 L | L2 | Admitted-Finance |
| 3 | L3₹4.6 LAdmitted-Finance | -27.00% | ₹4.6 L | L3 | Admitted-Finance |
| 4 | L4₹4.6 LAdmitted-Finance | -26.99% | ₹4.6 L | L4 | Admitted-Finance |
| 5 | L5₹4.6 LAdmitted-Finance | -26.95% | ₹4.6 L | L5 | Admitted-Finance |
Tender Value
₹6.3 L
EMD Value
₹12,660
Closing Date
9 Jan 2026, 4:00 pmClosed
Er. Ravinder Kumar
Executive Engineer PWD RNB Division Kishtwar
Please refer BOQ
2025_PWDJK_299121_1
e-NIT No. 56 of 2025-26 Dated 26-12-2025
Open Tender
Civil Works
30 days
KISHTWAR
Please refer NIT
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RNB Division Kishtwar
₹12,660
22 Jan 2026
26 Dec 2025
10 Jan 2026
26 Dec 2025
9 Jan 2026
26 Dec 2025
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Hand Packed stone at an Horizonal Level including Cost of Stones
Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer: Using M.S. angles 40x40x6mm for diagonal braces
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Providing, supplying, installation, wiring, testing and commissioning of outdoor LED lighting for gate pillars, complete in all respects, consisting of weather-proof LED luminaire (10W to 25W, IP-65 protection) suitable for outdoor use, mounted on gate pillar including fixing accessories, clamps, screws and mounting hardware, weather-proof junction box, PVC/FRLS insulated copper conductor cable of suitable size (1.5 sq mm to 4 sq mm, 1100V grade) drawn through PVC conduit/trunking, proper termination at luminaire and supply point, earthing with GI/Copper earth wire connected to existing/nearby earth system, supply and fixing of miniature circuit breaker (MCB) with metal enclosure, all necessary civil works such as chasing, making good, sealing and finishing, interconnection with existing electrical supply, testing, commissioning and handing over complete as per IS specifications, CPWD/PWD norms and directions of Engineer-in-Charge Complete JOB
Sand at an average lead of 30 km by MT
Bajri below 40 mm at an average lead of 7 km by MT
Bajri Above 40 mm at an average lead of 7 km by MT
Stone at an average lead of 5 km by MT
Bricks at an average lead of 210 km by MT
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.89 MB
BOQ_970035.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid