Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹48.0 L+₹3.8 L (8.71%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹48.8 L+₹4.7 L (10.6%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹49.1 L+₹5.0 L (11.3%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹49.5 L+₹5.4 L (12.2%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
22 Aug 2023, 6:00 pmClosed
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
REPAIR REPLACEMENT OF CERTAIN SUB MAIN AND POINT WIRING DBS AND MCCBs MCBs CEILING EXHUAST FAN WALL MOUNTED FANS REPAIR TO CONVERSION FROM CERTIAN CONVENTIONAL LIGHT TO LED LIGHT FITTINGS FLAME PROOF FITTINGS LIGHTENING PROTECTION SYSTEM....
2023_MES_611514_1
8867/CDP
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandipur
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹86,000
Yes
6 Oct 2023
1 Aug 2023
24 Aug 2023
1 Aug 2023
22 Aug 2023
15 Aug 2023
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' PART-I
Taking down carefully copper/aluminum point wiring (Light fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials for taking credit and making good disturbed surfaces of wall, floor, etc.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps switch socket combination on independent board controlled with one, oneway switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 15/16 amps socket outlet on independent board controlled with one, 15/16 amps one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps switch socket combination on independent board controlled with one, oneway switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 6/16 amps socket outlet on independent board controlled with one, 16 amps one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L switch piano, flush type single pole, one way 5 Amps including connection.
M&L switch socket combination 2 in 1, 5 Amps flush type including connection
S & F switch socket combination 5 in 1, 3 pin, 5 and 16 Amps flush type
M&L ceiling rose PVC poly carbonate, isolated body with three terminals including connection.
S & F Electronic fan regulator, stepped type 120/280V complete all as directed.
Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed.
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 2.5 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Three runs of 2.5 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 4 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Three runs of 4 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Three runs of 6 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
M&L Submain wiring using six runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Six runs of 6 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
M&L Submain wiring using six runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 10 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Six runs of 10 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
Supply and fix in repair vertical TPN MCB DB 8 way with 200 Amps rated busbar, double door type including provision for fixing MCCB 4 pole 100 Amps, 25 KA complete including taking down old DB and making disturbed surafce good to match the existing surface complete all as specified and as directed.
S & F in repair MCB DB made of sheet steel phosphatised powder coated with bus bar, neutral link, earth bar and din rail, double door type, TPN 4 way 415 v, fixed in wall including making good disturbed surfaces including taking down old unserviceable , complete all as directed.
All as per Sl Item No. 1.22 here-in-before but of SPN 8 way,240Volts double door complete.
All as per Sl Item No. 1.22 here-in-before but of SPN 12 way,240Volts double door complete.
S & F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 100 Amps including taking down old unserviceable one.
All as per Sl Item No. 1.25 here-in-before but of capacity 63 Amps, 4 Pole, 16 KA.
S & F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 25 kA, 415 Volts, 100 Amps including taking down old unserviceable one.
All as per Sl Item No. 1.27 here-in-before but of capacity 63 Amps, 4 Pole, 18 KA.
S & F in repair MCB, SPN. 40-63 Amps rating 240, volt, 'C' series, 10 kA.
S & F in repair , MCB, TPN, 415 V, 50Hz, 10kA, 'C' series, 63 Amps series.
S & F in repair , MCB, TP, 415 V, 50Hz, 10kA, 'C' series, 25 to 63 Amps series.
S & F in repair MCB, SP, 6 to 32 Amps, 240 volt, 'B' Series, 10 kA, as in repairs.
S & F in repair MCB, SP 40 Amps, 240 volt, 'C' Series, 10 kA, as in repairs.
Supply and fix in repair LED retrofit tube complete with powder coated decorative LED T-8 Batten with polycarbonate tube of capacity 20 Watt complete with including PVC insulated flexible copper wire of size .5 sqmm 2 core from ceiling rose to fitting complete incl taking down old fitting all as specified and directed
All as per Item Sl No. 1.34 above but retrofit LED tube rod only of capacity 20 Watt.
All as per Item Sl No. 1.34 above but 10 Watt, 2' all as specified and directed.
Supply & fix LED luminaire 600 mm x 600mm 35/36 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver holder & LED lamp suitable for roof ceiling including connection up with driver three core flexible copper conductor case of suitable size complete. all as specified and directed.
Supply & fix LED luminaire 16 cm x 16 cm 12 watt squar/round 220 volts AC recessed type with octane LED panel high efficiency PMMA diffuser soft glare free light complete with driver holder & LED lamp suitable for roof ceiling including connection up with driver three core flexible copper conductor case of suitable size complete. all as specified and directed.
S & F in repair Sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP of 20 Amps.
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
S & F Earthing conductor with GI strip of size (25 x 4) mm complete all as directed.
Disconnecting electrically and dismantling of ceiling fans of any make capacity and type, washing thoroughly of bearing /bush, fan blades and body of fan by kerosene /petrol etc and greasing for smooth functioning. Replacement of worn out/defective unserviceable parts (where ever necessary), reassembling the same including provision of three core flexible copper wire 1.5m long, including one coat of synthetic enamel paint (first quality) with super glossy finish to fan body and blades refixing the same to its original position including testing complete all as directed. NOTE : Replacement of worn out/ defective/unserviceable parts, flexible copper wire and rewinding shall be measured and paid separately under relevant items of these schedule.
All as per Sl Item No. 1.42 here-in-before but for Exhaust fans of any size and make.
All as per Sl Item No. 1.42 here-in-before but for air circulator fans/wall mounting fans of any size and make.
M&L Rewinding the motor of AC ceiling fan of any make and size (1200/1400mm) with super enamelled copper wire of adequate size/gauge including all insulation materials, varnishing etc complete all as directed.
All as per Sl Item No. 1.45 here-in-before but for exhaust fans of 300/380mm sweep of any make.
All as per Sl Item No. 1.45 here-in-before but for air circulators/wall mounting fans of any make and size.
Supply only Ball bearing of suitable size for any type/make of ceiling fan, Make : TATA/NBC/SKF.
All as per Sl Item No. 1.48 here-in-before but for Exhaust fans of any type/size/make.
All as per Sl Item No. 1.48 here-in-before but for air circulators/ wall mounting fans of any type/size/make.
Supply only capacitor 220 volts, 2.5 mfd suitable for ceiling fan, Make : SARADA/ TIBOCON/ UNIVERSAL.
Supply only capacitor 220 volts,4 mfd suitable for ceiling fan, Make : SARADA/ TIBOCON/ UNIVERSAL.
S & F in repair Hanging clamp for ceiling fan of adequate size including rubber reel, nuts, bolts and washers etc complete including taking down old unserviceable one, all as directed.
Taking down / Dismantling carefully old flame proof flood light/well glass fitting of capacity 80/250 Watt. with connected accessories with making good dusturbed surfaces of truss, walls, floors, etc. to match with existing and all as directed.
Supply and fixing complete FLP-WP Flood light fitting wall mounted in aluminium alloy LM6 construction of IP66 degree of protection, suitable for 120 watt LED light with lamp, driver etc, light gray epoxy powder coated 1 no internal and 2 nos external earthing with SS hardware along with 2 nos 3/4" ET cable entries with suitable double compression brass nickel plated cable gland,type A toughened glass certified by CIMFR,Dhanbad for Gas Group IIC as per IS/IEC-60079&CCOE Nagpur complete all as specified and directed as per Cat no.-SSPL/FL/1251 of make-Shyam or equivalent of Bajaj/Phillips/Sudhir
Supply and fixing complete Flame proof wellglass cum Flood light fitting Sunflower Type Ceiling and Pole MountedMounted in aluminium alloy LM6 construction of IP66 degree of protection, suitable for 150 watt LED light with lamp, driver etc, light gray epoxy powder coated 1 certified by CIMFR,Dhanbad for Gas Group IIC as per IS/IEC-60079&CCOE Nagpur complete all as specified and directed as per Cat no.-SSPL/WG/1251 of make-Shyam or equivalent of Bajaj/Phillips/Sudhir
S&F in repair LED Bldg security light fitting 45 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories including taking down old fitting as directed.
SCHEDULE 'A' PART-II Note : Connected items required under this part shall be measured and paid under respective items of Part-I.
Taking down / Dismantling carefully old flame proof flood light/well glass fitting of capacity 80/250 Watt. with connected accessories with making good dusturbed surfaces of truss, walls, floors, etc. to match with existing and all as directed.
Supply and fixing complete FLP-WP Flood light fitting wall mounted in aluminium alloy LM6 construction of IP66 degree of protection, suitable for 120 watt LED light with lamp, driver etc, light gray epoxy powder coated 1 no internal and 2 nos external earthing with SS hardware along with 2 nos 3/4" ET cable entries with suitable double compression brass nickel plated cable gland,type A toughened glass certified by CIMFR,Dhanbad for Gas Group IIC as per IS/IEC-60079&CCOE Nagpur complete all as specified and directed as per Cat no.-SSPL/FL/1251 of make-Shyam or equivalent of Bajaj/Phillips/Sudhir
Supply and fixing complete Flame proof wellglass cum Flood light fitting Sunflower Type Ceiling and Pole MountedMounted in aluminium alloy LM6 construction of IP66 degree of protection, suitable for 150 watt LED light with lamp, driver etc, light gray epoxy powder coated 1 certified by CIMFR,Dhanbad for Gas Group IIC as per IS/IEC-60079&CCOE Nagpur complete all as specified and directed as per Cat no.-SSPL/WG/1251 of make-Shyam or equivalent of Bajaj/Phillips/Sudhir
Taking down / dismantling old unserviceable submain wiring of any type / size and capacity.
M&L for submain wiring with two runs of PVC insulated, unsheathed FRLSH cable with multistranded copper conductor,1100 volt grade of size 4.0 sqmm, including one run of FRLSH grade 4.0 sqmm PVC insulated, stranded, copper conductor cable as earth wire drawn in and including flameproof ERW stove enamelled steel rigid / flexible conduit of suitable dia with bend, elbow, couplings, GI saddle clips etc and connecting up complete including taking down old unserviceable submain wiring and all as directed . (Note: Two runs of 4.0 sqmm wire and one run 4.0 sqmm FRLSH PVC cable and one run of suitable size ERW steel conduit shall be measured as one length)
M&L for submain wiring with two runs of PVC insulated, unsheathed FRLSH cable with multistranded copper conductor,1100 volt grade of size 2.5 sqmm, including one run of FRLSH grade 2.5 sqmm PVC insulated, stranded, copper conductor cable as earth wire drawn in and including flameproof ERW stove enamelled steel rigid / flexible conduit of suitable dia with bend, elbow, couplings, GI saddle clips etc and connecting up complete including taking down old unserviceable submain wiring and all as directed . (Note: Two runs of 2.5 sqmm wire and one run 2.5 sqmm FRLSH PVC cable and one run of suitable size ERW steel conduit shall be measured as one length)
S & F flame proof rotary switches with cable in LM – 6 single pole ON - OFF 10/16 Amps make: - Shyam switch Gear Cat no-SSPL/2C/1010 or equivalent of Sudhir / BALIGA
S & F flame proof rotary switche including socket and plug combined in LM – 6 cable termination box of capacity 16 A, 250 V, 2 P+earth complete all as specified and directed. Make: - Sudhir switch Gear Cat no-SS/OA/1010-1 or equivalent model of Shyam / Baliga.
Taking down / dismantling old unserviceable Distribution Boards/Main Switch of any type / size and capacity.
Supply and fixing flame proof/weatherproof distribution board TPN 8 way size 420 x 420 x 250 mm with provision of incoming MCB TPN 63 Amps- 01 No and out going SP MCB 6 to 32 Amps -12 Nos including taking out old unserviceable DB complete all as specified and directed. Cat Part No SSPL/RCP/109 of Shyaam Make or equivalent in Bajaj/L&T/Legrand
Taking down flameproof aluminium point wiring of light, FLP power switch/socket etc. complete, including connected fitting and fixtures such as junction box,terminal box by unscrewing from board,metalic hose conduit (excluding flameproof luminaires,FLP rotary switches, FLP power switch/socket & plug to be measured seperately) from hangers and removing materials to store and keeping in safe custody for disposal as per credit schedule and making good dusturbed surfaces of walls, floors, etc. to match with existing and all as directed.
M & L for flame proof point wiring with PVC insulated sheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 2.5 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 2.5 Sqmm heat resistant and fire retardant copper conductor cable as in continuous earthing for two light / fan points controlled by one FLP rotary switch.
Supply and fixing flameproof/weatherproof LED tube light fitting 1x 20 Watt with LED Tube rod complete including taking down old unserviceable fitting all as specified and directed. Cat Part No SSPL/FF/1271 of make -Shyaam or equivalent in Bajaj/Phillips/Sudhir
Supply and fix in repair LED down light 20 watt with aluminiu housing and provision of cutting and making space of suitable size on existing ceiling of any type complete including taking down old us fitting all as specified including complete all as directed.
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
All as per Sl Item No 2.15 above but using copper plate 60cm x 60cm x 3,15mm thick electrode and 20 x 3mm copper strip as earthing lead complete including taking out old unserviceable earthing matrials all as specified and directed.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised iron strip of 32 x 6 mm complete including taking down old unserviceable strip all as specified and directed.
All as per Sl Item No 2.17 above but copper strip 20 x 3mm complete including taking down old unserviceable strip all as specified and directed
Taking out old Aluminium/copper strip from wall/roof top and keeping in safe custody for re-use and taking credit.
M & L for Dismantling PCC and taking out Air termination rod with GI Pipe complete all as specified and directed
Supply and fixing of single pointed air terminal Aluminum rod of 12mm dia and 300mm long.
S & F aluminium strip 25x3.15mm with saddle and fixing screws for roof conductors and down conductors above ground.
RANA ENTERPRISES
chauhan syndicate
ELECTRO COMMERCIAL CO
Bansal And Co
RPL SYNDICATE CO
DS ENTERPRISES
jlenterprise
Bidder Name
RANA ENTERPRISES
DS ENTERPRISES
RPL SYNDICATE CO
Bansal And Co
KRISHNA ENTERPRISES
chauhan syndicate
ELECTRO COMMERCIAL CO
jlenterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .