| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC AWARD OF CONTRACT |
| 2 | L2₹1.5 Cr+₹68,881.26 (0.48%)Rejected-Finance 00 JAI BHAWANI COMPLEX MAIN ROAD SADAR WARD JAGDALPUR BASTAR CHHATTISGARH 494001 UDYAM CG 01 0003803 | BASTAR | CHHATTISGARH | 494001 | ₹1.5 Cr+₹68,881.26 (0.48%) | L2 | Rejected-Finance REJECTED SINCE NOT L1 |
| 3 | L3₹1.5 Cr+₹4.7 L (3.25%)Rejected-Finance | ₹1.5 Cr+₹4.7 L (3.25%) | L3 | Rejected-Finance REJECTED SINCE NOT L1 |
| 4 | L4₹1.6 Cr+₹13.7 L (9.48%)Rejected-Finance | ₹1.6 Cr+₹13.7 L (9.48%) | L4 | Rejected-Finance REJECTED SINCE NOT L1 |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
14 Jan 2020, 6:00 pmClosed
CE AF ALLAHABAD
HQ CE AF ALLAHABAD
ADDN /ALTN TO REFUELLING COMPLEX AT 17 WING AF STATION GORAKHPUR
2019_MES_302061_1
958970/E8
Open Tender
Civil Works
Lump-sum
365 days
GORAKHPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
Yes
GE (AF) GORAKHPUR
₹2.6 L
Yes
4 Feb 2020
29 Nov 2019
20 Jan 2020
29 Nov 2019
14 Jan 2020
31 Dec 2019
7 Dec 2019 - 13 Dec 2019
Amount
Construction all as specified and as shown on drawings.
Construction of Rest room ,Sampling room , and QC lab building with permanent specification of group VII building .Height: 320 Cm as listed in Sch ‘A’ Part I . (Lump sum price to be worked out by the contractor )
Schedule A Part-II ( Internal Water Supply)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II .
Schedule A Part-III ( Internal Electrification)
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part III .
Schedule A Part-IV( External Electrification}
Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part IV.
Schedule A Part-V ( Road Path and Culvert )
Lump sum price worked out by the contractor for Road path and Culvert as listed in Sch ‘A’ Part V
Schedule A Part-VI ( Sewage Disposal )
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI
Schedule A Part -VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch ‘A’ Part -VII.
Schedule A Part -VIII (Light Protection)
Lump sum price worked out by the contractor for Light Protection as listed in Sch ‘A’ Part -VIII.
Schedule A Part -IX (Addn/Altn B/R Work)
Lump sum price worked out by the contractor for Addn/Altn B/R Work as listed in Sch ‘A’ Part -IX.
Schedule A Part -X(EXCAVATION AND EARTH WORK)
Lump sum price worked out by the contractor for EXCAVATION AND EARTH WORK as listed in Sch ‘A’ Part X.
Schedule A Part -XI(Misc item)
S & F CP urinal spraider of 15mm bore fancy types screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S & F for CP Jet spray with 1.00M long CP Flexible tube complete all as specified and directed.
S & F 2 way CP angle cock of 15mm bore fancy types screwed down screwed for iron pipe or for brass ferrule complete all as specified and directed.
M & L Septic tank designed to carry sewage including excavation in all type of soil, base concrete below foundation PCC 1:4:8 type D-2 ,foundation in PCC (1:2:4) type B-1 ,brick works in CM (1:4), RCC slab covers including RCC 1:2:4 type B1 (using 20 mm graded agg) in pre-cast manholes cover having 6mm plate embedded all round/fibre reinforcement cover with angle iron frame vent shaft chamber for 25 users complete all as specified and directed.
M & L for construction of soak well 1.8m internal dia and 3.00 mtr effective depth including earth work in any type of soil foundation concrete PCC honey com brick work solid brick work in cement mortar 1:4 with top ring of M-25 concrete, RCC cver slab of M-25 concrete,SRFC cover, and precast manholes covers including reinforcement, with brick bats filling complete all as specified and directed by Engineer-in-charge.
Supply, install and testing of split type Air conditioner of capacity 1.5 Ton,Inverter type 5 star rating for working on 230 Volts,Single phase,50 Hz complete including cutting of existing wall and proper fixing and disturbed surface matching with existing surface and provided pipe for water uptp ground level complete all as specified and as directed. Make: Hitachi/Bluestar/Carrier. Note: Refrigerant of the AC should be non CFC based.
Supply and fixing wall mounted voltage stablizer 4 KVA for automatic voltage correction single phase naturally air cooled indoor type disigned for input voltage 170V to 250V with output voltage stabilized at 230V with accuaccy of + 2.5% with high/low voltage cut off with facility of incl instant start and time delay complete all as specified and directed. Make: V-Guard/VENUS/VOLINA
Taking down old and unserviceable Air Termination Aluminium Rod complete.
Taking down old and unserviceable GI earthing complete.
Taking down old and unserviceable terminal block complete
Taking down old and unserviceable Aluminium Strip complete.
M&L for Earthing complete with galvanized steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized strip of size 32mm X 6mm as Earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe medium grade 40mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanized Iron/steel of size 75x75x 25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh,20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed.
M&L boring of holes under road by trenchless technology using ultra sound technology and necessary machine suitable for inserting 150mm dia including light grade GI Pipe 100mm not more than 1.5 meter depth complete all as specified and directed.
S & Fixing wall/surface mounted type LED light fitting complete with LED lamp of 1x18-22 watt, 5700K (4 ft) , polycarbonate housing & integrated electrionic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable . Make - Havells Cat No-LUMILINEBS20WLED865SPCWH/Bajaj cat no -BCLSB18 NW (112410)
Supply and Fixing ceiling fan with down rod, fan connector/ fan hook, 1200mm sweep, 240 V AC with 3 Blade and connecting up including provn of three core PVC insulated multi stranded flexible copper conductor cable of size 1.5 sqmm copper wire from ceilling rose to fan of length not less than 0.5 mtr. All as specified & directed. Make - Crompton( model Aura plus-5 star)/Orient model no (Energy star)/Standard model no (super speed 50).
Supply and fixing PVC Exhaust fan of 300 mm sweep , single phase 230 V AC , 900 RPM , including mounting frame, nut, bolts, washers, fasteners etc and connecting exhaust fan to ceiling rose including provn of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified .Make - Bajaj maxima
S & F Modular PVC enclosures with plug and socket single pole and neutral with a two pin and earth plug and socket,240V , AC complete with one single pole MCB of capacity 20 Amp complete all as specified and directed by Engr-in-charge
Supply and fix LED street light 25 W IP 66 including all connections complete all as specified and directed including 40 mm dia GI brackets and all fiiting complete all as specified and directed by Engr-in-Charge.
Supply and fixing of flame proof exhaust fan size 380 (15") single phase complete all as specified.
Supply and fix Flame proof surface mounted type LED light fitting with die cast aluminum housing of size 1X 20 W complete with all accessories
Supply and fix flameproof MCB distribution box SPN 8 way, AC 240 V compltet all as specified and as directed by engr-in-charge.
Supply and fix MCB SPN 16 Amp, 240V volt B curve complete all as specified and directed.
S&F MCB SPN 40 Amp, 240V volt B curve complete all as specified and directed.
Supply and fix MCB SP 20 Amps 240V volt B curve, complete all as specified and directed.
Supply and fix MCB SP 6 Amps 240V volt B curve, complete all as specified and directed.
Taking down old and unserviceable Point wiring including complete fitting and fixtures such as switch, socket, regulator, ceiling rose etc and excluding light fitting
Taking down old and unserviceable Light fitting 40 W
Taking down old and unserviceable Flameproof switch
Taking down old and unserviceable Junction Box LM6 enclosure
Supply and fix wall mounting Fan,heavy duty,ISI marked,AC,50 hz of size 450 mm sweep complete all as specified and as directed by Engr-in-Charge. Make: Orient/Usha/Crompton
sanjay enterprises
M/s Comfort Air Conditioning and Refrigeration Engineers
M/s Suresh Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .