Loading…
Loading…
Tender Value
₹2.5 Cr
EMD Value
₹1.5 L
Closing Date
15 Jun 2026, 5:00 pm
MR Yognarayan sahu(DFLT)
CE(Baster)
CONSTRUCTION WORK OF 100 BEDED GIRLS HOSTEL (Balance work) IN VEER GAIND SINGH COLLEGE BUILDING I/C Electrification approach Road AT PAKHANJORE DISTT. KANKER (C.G.)
191663
NIT NO: 307/TC/2026-27
RESTRICTED TENDER
WORKS
12 days
CE(Baster)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Baster)
PWD Circle, Kanker
Division Bhanupratapur
120
12
No
0
191663
15 Jun, 2026 5:00:00 PM IST
18 Jun, 2026 10:00:00 AM IST
29 May, 2026 5:00:00 PM IST
NIT NO: 307/TC/2026-27
CONSTRUCTION WORK OF 100 BEDED GIRLS HOSTEL (Balance work) IN VEER GAIND SINGH COLLEGE BUILDING I/C Electrification approach Road AT PAKHANJORE DISTT. KANKER (C.G.)
150000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
25279000.00
2
17 Jun, 2026 5:00:00 PM IST
25279000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
17d 3h 57m
6 documents required · 5 mandatory · 1 optional
₹0
₹1.5 L
29 May 2026
29 May 2026
18 Jun 2026
29 May 2026
15 Jun 2026
29 May 2026
17 Jun 2026
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. 1.1.1 In all types of soil
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. 1.6 - Extra for every additional lift of 1.5 m or part thereof. 1.6.1 - All types of soils
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work. 3.1.3 - 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.2.1 - 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.4 - Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, etc.complete as per drawings including cost of binding wire all complete: 3.12 - Thermo-Mechanically treated bars FE 415
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for 2.1.1 - Foundations, footings, base of columns and plinth beam in any shape and size.
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for 2.1.5 - Columns, Pillars, Piers and likes- rectangular or square in shape
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for 2.1.8 - Beams, lintels, cantilevers & walls
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for 2.1.7 - Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for 2.1.15 - Stair cases of all types excluding spiral and folded plate type, including risers and landings
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for 2.1.2 - Wall of any thickness including attached pilasters, buttresses etc. in super structure.
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 - Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.3 - Cement Mortar 1:5 (1 cement : 5 coarse sand)
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 - Cement Mortar 1:6 (1 cement : 6 coarse sand) 7.6 - Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 - Cement Mortar 1:6 (1 cement : 6 coarse sand) 7.6 - Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 - Cement Mortar 1:6 (1 cement : 6 coarse sand) 7.6 - Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.3 - Cement Mortar 1:5 (1 cement : 5 coarse sand) 7.6 - Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.3 - Cement Mortar 1:5 (1 cement : 5 coarse sand) 7.6 - Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 7.7 Extra for brick work in square and rectangular pillars. (size not more than 600mm in any direction)
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level 7.11.2 Cement Mortar 1:4 (1 cement : 4 coarse sand)
Providing and fixing 38 mm thick wooden shelves supported on 40x40x6 mm T or L in brackets fixed at suitable distance in 5x75x150mm blocks of cement concrete 1:2:4: 8.51.2 Bijasal, Haldu, Benteak, Khair
Providing and fixing M.S. frames of doors, windows, ventilators and cupboards joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 9.16.2 Angle-iron frames
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing flush door shutters, core of block board construction with frame of first class hard wood and well matched first class Indian teak ply veneering on one face and commercial ply veneering on the other face of the shutter with vertical grains, cross bands and face veneering excluding hinges. 8.14.2- 35 mm thick (single leaf)
Extra for double leaf shutter instead of single leaf.
Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry.
Providing and fixing lipping with second class teak wood lipping on all edges of shutters. 8.18.3 35 x 6 mm size
Providing and fixing aluminium tower bolts (Barrel type) with necessary nickel plated iron screws etc complete. 8.122.1 250 x10mm
Providing and fixing aluminium tower bolts (Barrel type) with necessary nickel plated iron screws etc complete. 8.122.2 200 x10mm
Providing and fixing aluminium door handles 2.5mm thick with necessary nickel plated iron screws etc complete. 8.123.2 125 mm
Providing and fixing aluminium door mounted door stopper with necessary nickel plated iron screws etc complete. 8.125.1 100 mm long
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. complete.
Providing and making 18 mm thick cement plaster with under layer of 12mm thick cement plaster 1:5 (1 cement : 5 fine sand) finished with a top layer of 6mm thick cement plaster 1:3 (1 cement : 3 fine sand).
25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm)
KOTA stone slab 25mm thick in risers and treads of steps, skirting dado and pillar laid in 12mm (Average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single stone is to be used for riser and treads of steps and the width of stone for skirting and dado shall be equal to the height of skirting/ dado up to length of 1.0 M.)
Neat Cement punning.
Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer.
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 8.137.1 300mm
Providing and fixing stainless steel butt hinges IS : 12817 marked with necessary stainless steel screws etc complete. 8.132.1 150x2.5mm (heavy)
Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm 12.65.2 Pigment Coloured (rubber mould) precast interlock concrete blocks
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.1.5 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Providing sand faced plaster to concrete or brick masonry surface in all positions in two coats, base coat 13mm thick in C.M. 1:4, cleaning the surface by combing it and finishing coat 8mm thick in C.M. 1:3 and taking out grains on surface by hand operated mechanical arrangement with cost of all material labour, all leads & lifts, and scaffolding etc. complete.
6mm thick cement plaster in Mix: 11.1.2 - In Cement mortar 1:4 (1 cement : 4 fine sand)
12 mm thick cement plaster in mix: 11.2.4 - In Cement Mortar 1:6 (1 cement : 6 fine sand)
15mm thick cement plaster on the rough side of single or half brick wall of mix: 11.3.4 - In Cement Mortar 1:6 (1 cement : 6 fine sand)
15mm thick cement plaster on the rough side of single or half brick wall of mix: 11.3.3 - In Cement Mortar 1:5 (1 cement : 5 fine sand)
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 12.3.1 40 mm thick
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. 12.7.1 - Size upto 200x300mm
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. 12.9.1 - Size 300x300mm
White washing with lime to give an even shade. 14.5.1 - On new work Three or more coats)
Distempering with acrylic washable distemper to give an even shade. 14.9.1 - On new work (Two or more coats)
Finishing walls with water proofing cement paint of required shade to give an even shade. 14.14.1 On new work (Two or more coats applied @ 3.84 kg/10 sqm)
Painting on new work (two or more coats) to give an even shade with: 14.22.1 - Satin synthetic enamel paint
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.1 - 75 mm dia pipe.
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.2 - 110 mm dia pipe.
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.2 - 110 mm
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.1 - 75 mm
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.1 - 75 mm
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.2 - 110 mm
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.2 Double "Y" with or without door 18.77.2.1 75 mm
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.2 "P" trap 110mmx110mm long
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.3 - Vent covel 18.77.3.2 - 110 mm
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.6 Nahani trap 110x75mm
Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 20.1.1 - 150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 20.2.2 -150 mm diameter S.W. pipe
Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.1.1 White Long pattern W.C. pan of size 580 mm
Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.4.1 White pedestal type
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing and fixing ISI marked plastic seat with lid for pedestal type W.C. pan complete: 18.9.1 White/ black
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 19.7.1 15 mm dia nominal bore
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 19.7.2 20 mm dia. nominal bore
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 19.7.3- 25 mm dia nominal bore
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 19.7.4 32 mm dia. nominal bore
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 19.7.6 50 mm dia. nominal bore
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required 19.14.1 - Bib cock (450gms)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required 19.14.3 - Long body bib cock (500gms)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required 19.14.5 Two way bib cock (800 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required 19.14.6 Stop cock (concealed) (600 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required 19.14.7 - Angle valve for basin mixer and geyser points (450gms)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required 19.14.14 Soap dish plate
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required 19.14.15 Shower rose (revolving type) (150mm)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required 19.14.16 Towel rail (600mm long x 20mm dia)
Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 19.18.3 40 mm nominal bore
Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 19.18.4 50 mm nominal bore
Providing and fixing stainless steel drain jali of approved make/quality.
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the wei ght of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 20.3.1 100x100 mm size P type
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 20.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level 21.2.1 All types of soil 21.2.1.3 150 mm dia.
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level 21.2.2 Rocky strata including Boulders. 21.2.2.3 150 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, slotted casing pipe made from ISI marked G.I. pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part- 1&Part-2) 1992 with IVth revision (having slot of size 1.6/3.2 mm), of reputed and approved make, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-incharge. 21.6.3 150 mm nominal dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete 21.12.3 150 mm clamp.
Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :
Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.17.1 White Size 550x450 mm
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 18.21.2 1040x510 mm bowl size 460x410x200 mm
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 18.25.2 40 mm dia
Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. 9.6.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete.
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 A Plant mix method (with Mechanically crushed stone only) (a) For Lower Sub-base with (i) Grading-III Material
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.
Prime coat (Providing and applying primer coat with oil based bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per clause 502. (i) on WBM/WMM surface @0.85 Kg/sqm.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. (ii) Granular surfaces treated with primes @ 0.30 kg /Sqm
Open-Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades as per clause 510) (i) Mechanical method using Bitumen and minimum 40-60 TPH capacity hot mix plant. With mechanical paver finisher.
Seal Coat (Providing and laying seal coat for sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall including rolling and finishing using Type A and B seal coats as per clause 511) B Type -'B' (i) Providing and laying of premix sand seal coat with minimum 40-60 TPH HMP of appropriate capacity using crushed stone chipping (passing through 2.36mm size sieve) and with bitumen as binder.
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98- 2011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts , joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. (i) Single row for one utility service
Construction of RCC open drain (ii) Construction of RCC open drain 0.60m x 0.60m inside dimension lined with 120 mm thick RCC M-20 walls, 120 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 8 mm dia horizontal bars @ 150 mm c/c and L-shaped 8 mm dia vertical bars @ 150 mm c/c (L= 800 mm) including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Plain cement concrete complete as per drawing and Technical Specifications (i) PCC Grade M 15
Providing 1st class bedding below pipes with graded sand or other granular materials passing through 5.6 mm sieve as per clause 2904.
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) C 900 mm dia
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point
Medium Point
Long Point
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.2 Medium Point
Long Point
Extra Long Point I
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.3 Long Point
Extra Long Point I
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.2 3 X 2.5 sq. mm in 20mm conduit
6 X 2.5 sq. mm in 25mm conduit
9 X 2.5 sq. mm in 32mm conduit
12 X 2.5 sq. mm in 32mm conduit
3 X 10 sq. mm in 25mm conduit
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.9 Fan regulator (two module size) electronic stepped type moving all rounds
Batten/ angle holder
Ceiling rose 3 pin 5 amp
Providing and fixing composite board for computer points having piano type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch and 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable M.S box, 3mm thick phenolic laminated sheet cover including painting etc. as per specification.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 Deluxe
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 1200 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep
380 mm sweep
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.6 15 watt
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.4 36 watt {4 feet}
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.8 90 watt
Fabrication and installation of angle iron including angle size 50 mm x 5 mm thick with labour charges including materials as per specification.
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.1 Upto 300 mm deep
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.21.1 100 amp (20x3mm)
200 amp (25x5mm)
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.1 3 pole MCCB, 25-63A, Fixed Thermal Release, 10KA
3 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 25KA
4 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 50KA
4 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA
4 pole MCCB, 320A, Adjustable Thermal - Magnetic Release, 50KA
Supplying and fixing on surface/ recess vertical type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, with 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland/ knock out plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 9.5.5 8 way (4 + 24), Double door
4 way (4 + 12), Double door
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.6 8 way Double door
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1 6 amps to 32 amps
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.16.5 63 amps
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as per specification.
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.2 100/5 amps
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.
For ammeter
Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as per specification.
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification.
Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 15.1.14 3.5 x 70 sq. mm.
4 x 10 sq. mm.
4 x 16 sq. mm.
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . 15.23.23 4 X 10 sq. mm (22 mm)
4 X 16 sq. mm (22 mm)
Supplying and making outdoor end termination with cast resin compound including aluminum lugs and other jointing materials for following size of FRLS PVC insulated and PVC sheathed / XLPE aluminum conductor power cable of 1.1 KV grade as per specification. 15.25.3 3½ X 70 sq. mm
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Supplying and laying HDPE pipe of 4kg/Sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.2.1 63 mm outer dia
Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.3.2 80 mm internal dia
UOM Name
Percentage
Per mile
1000 piece
Per Diem Rate
MAN DAYS
Siemens Per meter
Price Should be quoted as per SKU in Aneexure-I of Tender Document
As per Tender
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.09 MB
1660105386343997200_188855_ANNEXURE E.doc
NIT • 0.08 MB
4355648977090759701_152305_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
5694585950859708825_188855_NIT.doc
NIT • 0.33 MB
8172191910198547193_188855_FORM A.doc
NIT • 0.15 MB
4067063874507570364_191663_Notice.docx
NIT • 0.04 MB
1207088685412093431_188855_BOQ.xlsx
BOQ • 0.09 MB
4615193742269536125_188855_list of approved materials.xlsx
BOQ • 0.02 MB
Download all tender documents and submit your bid