Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹82.2 L PLOT NO F AND G RAKBA DARAKHERA PROFESSOR COLONY NAGAR PARISAD THANESAR KURUKSHETRA HARYANA 136 118 |
Tender Value
₹10.5 Cr
EMD Value
₹10.5 L
Closing Date
23 Aug 2025, 11:00 amClosed
Operation and maintenance of civil, sanitary/plumbing, Electrical Installation, Servicing E M equipments and AMC of DG sets, CAMC of HVAC plants, Fire Fighting, STP, Horticulture works, Mechanized Housekeeping, round the clock Security Services etc
NSL/CEO/PLAZA/NIT/2025/768
NSL/CEO/PLAZA/NIT/2025/768
Open Tender-Domestic
Miscellaneous
South Delhi, Delhi
₹11,800
₹10.5 L
7 Oct 2025
8 Aug 2025
23 Aug 2025
23 Aug 2025
3 Sept 2025
Providing and laying factory made chamfered edge Cement
Concrete paver blocks in footpath, parks, lawns, drive ways or
light traffic parking etc, of required strength, thickness & size/
shape, made by table vibratory method using PU mould, laid in
required colour & pattern over 50mm thick compacted bed of sand,
compacting and proper embedding/laying of inter locking paver
blocks into the sand bedding layer through vibratory compaction
by using plate vibrator, filling the joints with sand and cutting of
paver blocks as per required size and pattern, finishing and
sweeping extra sand. complete all as per direction of Engineer-in-
80 mm thick C.C. paver block of M-30 grade with approved
16.91.2 color design and pattern.
Kota Stone slab flooring over 20mm (average) thick base laid over
11.26 and jointed with grey cement slurry mixed with pigment to match
the shade of the slab, including rubbing and polishing complete
with base of cement mortar 1:4 (1 cement : 4 coarse sand)
Marble Stone flooring with 18 mm thick marble stone, as per
sampleof marble approved by Engineer-in-charge, over 20mm laid
and jointed with grey cement slurry, including rubbing and
Providing and laying in situ seven course water proofing treatment with
APP (Atactic poly-propylene) modified Polymeric memberane over roof
consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th
& 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of
blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th
layers of roofing membrane APP modified Polymeric membrane 1.5 mm
thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with
14.86 centre core as 20 micron HMHDPE film sandwiched on both sides with sqm 900 ₹ 730.55 ₹ 6,57,495.00
polymeric mix and the polymeric mix is protected on both side with 20
micron HMHDPE film. 7th, the top most layer shall be finished with brick
tiles of class designation 10 grouted with cement mortar 1:3 (1cement :
3 fine sand) mixed with 2% integral water proofing compound by
weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement :
3 fine sand) and finished neat (item of laying brick tiles shall be paid for
Digitally signed by AMIT
Providing and laying in position ready mixed or site batched design mix
cement concrete for plain cement concrete work; using coarse aggregate
and fine aggregate derived from natural sources and using recycled
concrete aggregate (RCA) as coarse aggregate and fine aggregate
within the permissible utilization, Portland Pozzolana / Ordinary
Portland/Portland Slag cement, admixtures in recommended proportions
as per IS: 9103 to accelerate / retard setting of concrete to improve
durability and workability without impairing strength; including pumping
of concrete to site of laying, curing, carriage for all leads; but excluding
the cost of centering, shuttering and finishing as per direction of the
engineer-in-charge; for the following grades of concrete. Note: Extra
cement up to 10% of the minimum specified cement content in design
mix shall be payable separately. In case the cement content
in design mix is more than 110% of the minimum specified cement
content, the contractor shall have discretion to either re-design the mix
or bear the cost of extra cement.
4.20A.1 All works upto plinth level
Concrete of M10 grade with minimum cement
content of 220 kg /cum. (Note: The permissible utilization of
RecycledConcrete Aggregate (RCA) as coarse aggregate and fine
aggregate is 100% each).
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m
2.7 in width aswell as 10 sqm on plan) including getting out and disposal of
excavated earth lead upto 50 m and lift upto 1.5 m, as directed by
Engineer-in-charge
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to
50 and for all lift
Dismantling stone slab flooring laid in cement mortar including stacking
15.25 of serviceable material and disposal of unserviceable material within 50 sqm 247.42 ₹ 266.45 ₹ 65,925.06
Demolishing R.C.C. work manually/ by mechanical means
15.3 includingstacking of steel bars and disposal of unserviceable material cum 18 ₹ 3,551.25 ₹ 63,922.50
within 50 metres lead as per direction of Engineer - in- charge.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to
IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in all colours, shades except burgundy, bottle green, black of any
size as approved by Engineer-in-Charge, in skirting, risers of steps and
dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of matching
Providing and laying vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08%
and conforming to IS: 15622, of approved make, in all colours and
11.41 shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ sqm including
grouting the joints with white cement and matching pigments etc.,
Painting with synthetic enamel paint of approved brand and
13.99 manufacture of required colour to give an even shade :
13.99.1 One or more coats on old work Sqm 1000 ₹ 102.80 ₹ 1,02,800.00
Steel work welded in built up sections/ framed work, including cutting,
10.25 hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and
14.72 Scaffolding System :
Providing and fixing double scaffolding system (cup lock type) on the
exterior side, up to seven story height made with 40 mm dia M.S. tube
1.5 m centre to centre, horizontal & vertical tubes joining with cup &
lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S.
staircase system in the scaffolding for working platform etc. and
maintaining it in a serviceable condition for the required duration as
approved and removing it there after. The scaffolding system shall be Sqm 1000 ₹ 338.25 ₹ 3,38,250.00
stiffened with bracings, runners, connection with the building etc
wherever required for inspection of work at required locations with
essential safety features for the workmen etc. complete as per directions
and approval of Engineer-in-charge. The elevational area of the
scaffolding shall be measured for payment purpose.
The payment will be made once irrespective of duration of scaffolding.
Digitally signed by AMIT
26.81 Scaffolding Net :
Providing and fixing Scaffolding net of required width made of high
density Polyethylene UV stabilized knitted on warp knitting machine
having density 100grams/ sqm and shading coefficient minimum 75%
around the construction site/ for vertical extension as per requirement
including fastening/tying with building/ scaffolding pipes or with any
other fixtures etc. complete as per direction of Engineer- in-Charge.
Providing and inserting 12mm dia galvanised steel injection nipple in
honey comb area and along crack line including drilling of holes of
required diametre (20mm to 30mm) up to depth from 30mm to 80mm
26.39 at required spacing and making the hole & crack dust free by blowing each 500 ₹ 236.90 ₹ 1,18,450.00
compressed air, sealing the distance between injection nipple with
adhesive chemical of approved make and allow it to cure complete as
per direction of Engineer-In-Charge
Grouting the joints of flooring tiles having joints of 3 mm width, using
epoxy grout mix of 0.70 kg of organic coated filler of desired shade
11.48 (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /
grouting and finishing complete as per direction of Engineer-in-charge.
Total Civil DSR Amount ₹ 95,82,344.06
Add Cost index factor 103 on civil DSR Amount ₹ 98,69,814.38
Add Labour cess factor @0.973 as per CPWD circulater section B
Miscelleneous works
Servicing and Testing of 11 KV VCB panels make Alstom (4Nos)
Servicing of 1600 KVA, 33/0.433 KV VPI Dry Type Transformer including
overhauling, testing and tighting of core.(3Nos) Servicing and testing of
MR ACB 800-1600 A panels make L&T (23 Nos) Servicing and testing of LS 2 ₹ 3,61,935.00 ₹ 7,23,870.00
ACB 2000-2500 A panels make L&T (11 Nos) Service Maintenance kit
for ACb c Power (6 Nos) Servicing to be done Once in a year as per
direction of Enginner in Charge
Mechanized Cleaning (one time in year) of the Outer Façade
M.R Glasses of the building by applying chemicals and other materials Sqft 500000 ₹ 1.50 ₹ 7,50,000.00
etc. at any height. Nothing extra shall be paid for any kind of
arrangements or what so ever.
Digitally signed by AMIT
LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 <
120lm/Watt ) Supplying, installation, Testing & Commissioning of LED
Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type
of following body material with PMMA and prismatic diffuser and
construction as per IS : 10322 with driver as per the requirement with
Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency
50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal
surge protection of 2.5 KV with Short & Open circuit protection ,THD <
10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19,
Flicker free (flicker should be below 5%), life time (LED,Driver &
electrical circuitary), of minimum 50000 Burning Hours with 70% of
initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /
6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color
Matching) <3, Maximum power consumption should not more than the
specified rating and Fixture shall be confirming to relevant BIS
standards and trade mark certificate (T.C.). Manufactures Word Mark/
Name Engraved/ Embossing/ Screen printing on housing Complete in all
respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper
conductor single core cable and earthing etc. as required with Minimum
5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt
output . LM79 & LM80 Test report from NABL lab for all testing required
for LED fixtures as per BIS shall be submitted. Shape size and CCT shall
be as approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminum housing such that LED junction
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft.,
of following body material and construction as per IS : 10322 with
the requirement with Driver efficiency >85%, Operating voltage AC 140-
270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40
DSR E&M degcentigrade, internal surge protection of 2.5 KV with Short & Open
2025 circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR
1.6 (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %),
life time (LED,Driver & electrical circuitry), of minimum 50000 Burning
Hours with, 70% of initial Lumen maintained till life ends as per LM80
extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K
/6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color
Matching) <3, Maximum power consumption should not more than the
specified rating and Fixture shall be of relevant BIS standard and trade
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)
Supplying, installation, Testing & Commissioning of LED surface
mounted Batten light of following body material and construction as per
IS : 10322with driver (Replaceable) as per the requirement with Driver
efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz,
Operating temp range -15 deg to 40 deg centigrade, internal surge
protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,
P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %),
life time (LED,Driver & electrical circuitary), of minimum 50000 Burning
Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K
DSR E&M / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard
2025 Deviation Color Matching) <3, Maximum power consumption should not
1.9 more than the specified rating and Fixture shall be of relevant BIS
standard and trade mark certificate ( T.C.). Manufactures Word Mark/
Name Engraved/ Embossing/ Screen printing on housing. complete in all
respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper
conductor single core cable and earthing etc. as required with Minimum
5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt
output . LM79 & LM80 Test report from NABL lab for all testing required
for LED fixtures as per BIS shall be submitted. Shape size and CCT shall
be as approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminum housing such that LED junction
temperature shall not rise above 90°C).
LED Street light fixture, powder coated pressure die cast
aluminum body (System lumen efficacy ≥105 <120 lm/Watt)
Supplying, installation, Testing & Commissioning of Street light LED
fixture powder coated pressure die cast aluminum body with driver as
per the requirement with Driver efficiency >85%, Input voltage: 140-
270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg
centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-
DSR E&M 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.
2025 F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage
1.12 protection, EMIEMC As per CISPR -15, lenses for beam angle as per
IESNAtype I/II/III as per the width of the road and the project
requirement., suitable to fit in up to 65mm dia pipe, life time
(LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with
70% of initial Lumen maintained till life ends as per LM80 extrapolation
IES TM-21-11 report, CCT 3000°K / 4000°K
/ 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation
Color Matching) <5, Maximum power consumption should not more than
Prime cost has been taken for reimbursement of expediture like
Refilling Fire Extingushires, battery, seasonal plant, repairing of
motors, repairing of STP etc.. The contractor has to purchase the
items with prior approval of Enginner Incharge on most actual basis
competative rates from market and submi the bill to NSL along with
7.5% contractor profit.
C Section C Amount ₹ 30,77,270.00
Grand Total (A+B+C) Total ₹ 10,47,53,296.00
Grand Total (A+B+C) Total ₹ 10,47,53,296.00
Digitally signed by AMIT
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
BoQ PLAZA.pdf
Tender Document
SCC Plaza1.pdf
Tender Document
Scope of Work.pdf
Tender Document
GCC amendment 14.pdf
Tender Document
Forms.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
Integrity pact.pdf
Tender Document
corrigendum-4131-Corrigendum.pdf
pdf • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .