Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 CrAccepted-AOC 711 S S T NAGAR RAJPURA ROAD PATIALA PUNJAB MOB 9592400025 | ₹24.3 Cr | L1 | Accepted-AOC Due to lowest bid price |
| 2 | L2₹25.4 CrRejected-Finance | ₹25.4 Cr | L2 | Rejected-Finance Due to high bid price |
| 3 | L3₹25.6 CrRejected-Finance | ₹25.6 Cr | L3 | Rejected-Finance Due to high bid price |
| 4 | L4₹30.8 CrRejected-Finance | ₹30.8 Cr | L4 | Rejected-Finance Due to high bid price |
Tender Value
₹28.2 Cr
EMD Value
₹56.4 L
Closing Date
9 Jan 2026, 12:00 pmClosed
Executive Engineer
Provincial Division PWD BandR DAC Complex Sangrur
Construction of Sports Complex Sunam, Distt. Sangrur (Punjab)
2025_CEPW_156128_1
Bid No 77 Dt. 19-12-2025
Open Tender
Civil Works - Buildings
450 days
Sangrur
Please refer Tender documents.
7 documents required · 7 mandatory
₹50,000
₹56.4 L
Yes
Sangrur
9 Feb 2026
20 Dec 2025
9 Jan 2026
20 Dec 2025
9 Jan 2026
20 Dec 2025
2 Jan 2026
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Heritage & Culture Cess @ 1.00%
percent
Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Heritage & Culture Cess @ 1.00%
Extra Rate For Fouth Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Heritage & Culture Cess @ 1.00%
Extra Rate for Second Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
C.P. brass Bib cock with Wall flange
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Heritage & Culture Cess @ 1.00%
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Heritage & Culture Cess @ 1.00%
Extra Rate For Fifth Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Heritage & Culture Cess @ 1.00%
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For Fifth Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Heritage & Culture Cess @ 1.00%
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Extra for carriage of RMC/batch mixed concrete with transit mixture beyond 1st km .
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For First Floor
Heritage & Culture Cess @ 1.00%
Extra Rate For Third Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For First Floor
Heritage & Culture Cess @ 1.00%
Extra Rate For Fouth Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For First Floor
Heritage & Culture Cess @ 1.00%
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For First Floor
Heritage & Culture Cess @ 1.00%
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Diesel Engine Supply, installation, testing & Commissioning of pump model in back pull out design (end suction type) having 100mm suction, 80mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 56 BHP, 1800 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Extra rate for using steel from Integrated plant marked as primary Producer steel.
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Electric Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED DIESEL ENGINE DRIVEN PUMPSET in back pull design having 125mm suction, 100mm delivery, CI casing, bronze impeller, C-40 shaft with gland packed arrangement coupled on common MS fabricated baseframe vertical water cooled diesel engine complete with 12 V battery start arrangement, air cleaner, exhaust silencer(without piping), fuel filter, developing 50 BHP at 1800 RPM. Engine with twin belt driven radiator and complete with engine starting panel, Battery & AVM pods. Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
Dressed or moulded two brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufacture guidelines.
Pressure Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED Pressure Pump having Discharge 450 LMP and maintain required pressure in Down Comer as required by engg. in charge cpmplete in all respect Total head : 60m Flow : 450 Ipm
Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect.
12.5 mm thick cement plaster 1:5
Extra Rate For Fourth Floor
20mm thick cement plaster 1:5 in two coat work
12.5 mm thick cement plaster 1:4
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For First Floor
Forming groove of uniform size from 12xl2mm and upto 25xl5mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For First Floor
Extra Rate For First Floor
Extra Rate For Fifth Floor
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For First Floor
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm Coupling /Sockets
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For First Floor
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on- edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers inclu
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
idng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Extra Rate For First Floor
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material.
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. (14.135)
Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 12mm to 15mm Slabs sizes above 0.50 sqm
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Extra labour for projected nosing of stair case of any shape and design
Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4)
Extra Rate for Third Floor
Extra Rate for Fifth Floor
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
CC 1:2:4 with stone ballast
Providing/Collection and Laying sand filling laying in 15 cm layers, ramming, watering and consolidating including all leads complete as per specification and as per entire satisfaction of engineer-in-charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Providing & Fixing glass panes with nails and putty or wooden strip
complete in all respect. 5.0mm thick Plate glass (INDIAN)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
ame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
idng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
idng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
idng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
20mm thick cement plaster 1:4 in two coat work
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
idng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Imp teak wood cup board chowkats including iron hold fasts, iron hinges corner straps, wooden knobs or handles fixed in position (Size 45 x 60mm).
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Imported Teak Wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) 30 mm thick
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (10.16)
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
Centring and shuttering for Columns ( Square or Rectangular or plygonal in plain) in superstructure
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. (10.21)
Extra Rate for First Floor
Extra Rate for Second Floor
C.P. brass Bib cock with Wall flange
Extra Rate For First Floor
Centring and shuttering for sides and soffits of beam, beams launchingsgirders bressumers, lintels
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra rate for First Floor
Extra rate for Second Floor
Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. (11.6)
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete ISI designation no I (Size of door up to 700mm)
Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects.
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement sand mortar in super structure.
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete ISI designation no I (Size of door up to 700mm)
Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects.
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. (10.27)
12.5 mm thick cement plaster 1:5 (15.10)
20mm thick cement plaster 1:5 in two coat work (15.21)
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (13.45)
Providing and fixing in position gratings 150mmx150mm for gully trap. PVC grating
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. (13.51)
Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing (13.13 (i))
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (13.55)
Extra Rate for First Floor
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Extra Rate for First Floor
CONSTRUCTION OF VOLLEY BALL COURT
Extra Rate for First Floor
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Extra Rate for First Floor
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (14.84)
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing (14.86)
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness and colouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects. (14.142)
Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
Extra Rate for Fourth Floor
Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (14.89 b)
Providing and laying Laminate wooden flooring (Grade AC4 or AC4+ laminates) 6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminum oxide finish that protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer.
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. (14.135)
Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop ..
Pressure Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED Pressure Pump having Discharge 450 LMP and maintain required pressure in Down Comer as required by engg. in charge cpmplete in all respect Total head : 60m Flow : 900 Ipm
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) Float glass panes of 5 mm thickness
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm 5.0mm thick Plate glass (INDIAN)
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4)
Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S fr
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Providing & Fixing glass panes with nails and putty or wooden strip
ame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
20mm thick cement plaster 1:4 in two coat work
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
CC 1:2:4 with stone ballast
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti ncluding finishing the surface to required finish complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:-Above 15.00 mt. Span including the cost for machinery i.e. Hydra cranes etc. for hoisting in position.
Providing and instalation of integrally weighted movable Badminton Posts. The badminton posts shall allows regulation net height to be achieved detachable front upright. It shall be manufacture from 47x47mm square pipe 4mm thick. Base shall made up of strong pipe and shall have weight stock of cast/mild steel 70kg each side. Wheels shall non marking with bearing inside and the wheel shall have 100 mm dia. Complete with rubber feet to protect the playing surface and grip on wooden & synthetic floor. The poles shall either powder coated or spray painted.The net shall made up of nylon material ,suitable for all weather use.The four sides of net shall be covered with white waterproof vinyl tapes.
Supply of set of Moveble Basket Ball Poles having minimum weight 600kg on each side of pole and having adjustable height extension. Each Pole shall consist of Fibre board of size 1.05x1.8mtr and 25mm thick and shall consist of 2 nos dunking rings with net as per Standard Design
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Providing and Fixing multilayer Polyuerthane flooring (10+2mm) consisting of primer on asphault surface, elastic layer SBR matt (5-12mm), Pore sealer(0.1mm), Cast coating (2-3mm), Antiskid multitop (0.5mm) incliding making of Ground Approved by ITF on already laid Flooring System complete in all respect
Providing and Fixing of Turbo Fan /Non Electric Exhaust Fan 21"/22" dia to be fitted on roof top/shed etc. with imported polycarbonate body base complete in all respects upto to the entire satisfaction of the Engineer-In-Charge of the work
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Construction of Plinth protection complete
Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer. (10.6 b ii)
Construction of Plinth protection complete as per drawing.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres and Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. (As per CSR Item No.6.8 a (i) + 6.19)
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (10.16)
percent
Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Centring and shuttering for Columns ( Square or Rectangular or plygonal in plain) in superstructure
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791
and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. (10.21)
Centring and shuttering for sides and soffits of beam, beams launchingsgirders bressumers, lintels
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra rate for First Floor
Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer.
Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. (11.6)
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement sand mortar in super structure.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).
Extra Rate for First Floor
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. (10.27)
12.5 mm thick cement plaster 1:5 (15.10)
20mm thick cement plaster 1:5 in two coat work (15.21)
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (13.45)
Providing and fixing in position gratings 150mmx150mm for gully trap. PVC grating
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. (13.51)
Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing (13.13 (i))
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
CONSTRUCTION OF VOLLEY BALL COURT
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material (14.3)
Extra Rate for First Floor
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge to be laid below the topping using mechanical mixer for mixing of material (14.11)
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge.
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
CONSTRUCTION OF BUILDING OF INDOOR SPORT'S COMPLEX SUNAM
Extra Rate for Fourth Floor
Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. (14.135)
Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop ..
Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type
Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (14.89 b)
Providing & fixing Volley ball poll pairs made of MS standard size complete in all respects
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 3 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Pressure Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED Pressure Pump having Discharge 450 LMP and maintain required pressure in Down Comer as required by engg. in charge cpmplete in all respect Total head : 60m Flow : 900 Ipm
Extra Rate for First Floor (50% Quantity)
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4)
Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S fr
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
ame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
20mm thick cement plaster 1:4 in two coat work
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Supply of set of Moveble Basket Ball Poles having minimum weight 600kg on each side of pole and having adjustable height extension. Each Pole shall consist of Fibre board of size 1.05x1.8mtr and 25mm thick and shall consist of 2 nos dunking rings with net as per Standard Design
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Providing and Fixing multilayer Polyuerthane flooring (10+2mm) consisting of primer on asphault surface, elastic layer SBR matt (5-12mm), Pore sealer(0.1mm), Cast coating (2-3mm), Antiskid multitop (0.5mm) incliding making of Ground Approved by ITF on already laid Flooring System complete in all respect
Providing and Fixing of Turbo Fan /Non Electric Exhaust Fan 21"/22" dia to be fitted on roof top/shed etc. with imported polycarbonate body base complete in all respects upto to the entire satisfaction of the Engineer-In-Charge of the work
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Construction of Plinth protection complete
Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer. (10.6 b ii)
Providing & fixing Volley ball net of polyster white colour size 9.5m x 1.00 m, mesh size 100mm x 100mm complete in all respects
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Extra Rate for First Floor
Providing and
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect 5.0mm thick Plate glass (INDIAN)
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
laying vitrified floor tiles in different size in light colour shades made using Full Body Technology (thickness to specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand ), complete. (Full body vitirified tiles have pigment in entire body/ thickness of which make chips and scratches less noticeable and na ideal choice for high traffic zones) Size 600x600 mm CSR 14.115 a
Construction of Swimming Pool
Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications.
Extra Rate for Second Floor (50% Quantity)
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead .
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.Door and window frame of size 113mmx60mmx with 35mm wide single rebate.
CONSTRUCTION OF BUILDINGS WITH SWIMMING POOL
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres and Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. (As per CSR Item No.6.8 a (i) + 6.19)
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Second Floor
percent
Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Extra Rate For First Floor
Extra Rate For Second Floor
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Fouth Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate for Second Floor
Extra Rate For First Floor
C.P. brass Bib cock with Wall flange
Extra Rate For First Floor
Extra Rate For Second Floor
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Fifth Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For Fifth Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Extra Rate For First Floor
Extra for carriage of RMC/batch mixed concrete with transit mixture beyond 1st km .
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Fouth Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Extra Rate For First Floor
Extra Rate For Second Floor
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Diesel Engine Supply, installation, testing & Commissioning of pump model in back pull out design (end suction type) having 100mm suction, 80mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 56 BHP, 1800 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Electric Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED DIESEL ENGINE DRIVEN PUMPSET in back pull design having 125mm suction, 100mm delivery, CI casing, bronze impeller, C-40 shaft with gland packed arrangement coupled on common MS fabricated baseframe vertical water cooled diesel engine complete with 12 V battery start arrangement, air cleaner, exhaust silencer(without piping), fuel filter, developing 50 BHP at 1800 RPM. Engine with twin belt driven radiator and complete with engine starting panel, Battery & AVM pods. Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
Dressed or moulded two brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufacture guidelines.
Pressure Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED Pressure Pump having Discharge 450 LMP and maintain required pressure in Down Comer as required by engg. in charge cpmplete in all respect Total head : 60m Flow : 450 Ipm
Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect.
12.5 mm thick cement plaster 1:5
Extra Rate For Fourth Floor
20mm thick cement plaster 1:5 in two coat work
12.5 mm thick cement plaster 1:4
Extra Rate For First Floor
Extra Rate For Second Floor
Forming groove of uniform size from 12xl2mm and upto 25xl5mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
Extra Rate For First Floor
Extra Rate For First Floor
Extra Rate For Fifth Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Extra for c above 4 meters (where any single storey exceeds 4metres in height) for every additional height of 2 metres or part there of for Brick Work/ Concrete Block/ Clay Block.
Extra Rate For First Floor
Extra Rate For Second Floor
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Extra Rate For First Floor
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm Coupling /Sockets
Extra Rate For First Floor
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on- edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers inclu
Extra Rate For First Floor
Extra Rate For Second Floor
12.5mm thick cement plaster 1:4.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material.
20mm thick cement plaster 1:4 in two coat work.
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. (14.135)
Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 12mm to 15mm Slabs sizes above 0.50 sqm
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Extra labour for projected nosing of stair case of any shape and design
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4)
Extra Rate for Third Floor
Extra Rate for Fifth Floor
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
CC 1:2:4 with stone ballast
Providing/Collection and Laying sand filling laying in 15 cm layers, ramming, watering and consolidating including all leads complete as per specification and as per entire satisfaction of engineer-in-charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..
Providing & Fixing glass panes with nails and putty or wooden strip
ame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
idng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
idng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
idng ramming, watering and consolidated all lead . CSR 6.8 C(i)
20mm thick cement plaster 1:4 in two coat work
Extra Rate for First Floor
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
idng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Imp teak wood cup board chowkats including iron hold fasts, iron hinges corner straps, wooden knobs or handles fixed in position (Size 45 x 60mm).
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Imported Teak Wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) 30 mm thick
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges c
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres and Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. (As per CSR Item No.6.8 a (i) + 6.19)
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
percent
Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Extra Rate For Fouth Floor
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Extra Rate For Fifth Floor
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For Fifth Floor
Extra Rate For First Floor
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Extra for carriage of RMC/batch mixed concrete with transit mixture beyond 1st km .
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Extra Rate For Third Floor
Extra Rate For Fouth Floor
Extra Rate For First Floor
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Extra Rate For First Floor
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Diesel Engine Supply, installation, testing & Commissioning of pump model in back pull out design (end suction type) having 100mm suction, 80mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 56 BHP, 1800 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Electric Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED DIESEL ENGINE DRIVEN PUMPSET in back pull design having 125mm suction, 100mm delivery, CI casing, bronze impeller, C-40 shaft with gland packed arrangement coupled on common MS fabricated baseframe vertical water cooled diesel engine complete with 12 V battery start arrangement, air cleaner, exhaust silencer(without piping), fuel filter, developing 50 BHP at 1800 RPM. Engine with twin belt driven radiator and complete with engine starting panel, Battery & AVM pods. Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
Dressed or moulded two brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufacture guidelines.
Pressure Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED Pressure Pump having Discharge 450 LMP and maintain required pressure in Down Comer as required by engg. in charge cpmplete in all respect Total head : 60m Flow : 450 Ipm
Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect.
12.5 mm thick cement plaster 1:5
onforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Extra Rate For Fourth Floor
20mm thick cement plaster 1:5 in two coat work
Forming groove of uniform size from 12xl2mm and upto 25xl5mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
Extra Rate For First Floor
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm Coupling /Sockets
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
20mm thick cement plaster 1:4 in two coat work.
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. (14.135)
Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 12mm to 15mm Slabs sizes above 0.50 sqm
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Extra labour for projected nosing of stair case of any shape and design
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4)
Extra Rate for Third Floor
Extra Rate for Fifth Floor
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
CC 1:2:4 with stone ballast
Providing/Collection and Laying sand filling laying in 15 cm layers, ramming, watering and consolidating including all leads complete as per specification and as per entire satisfaction of engineer-in-charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
ame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Extra Rate for First Floor
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for First Floor
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
20mm thick cement plaster 1:4 in two coat work
Extra Rate for First Floor
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Imported Teak Wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) 30 mm thick
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer- in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres and Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. (As per CSR Item No.6.8 a (i) + 6.19)
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
percent
Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Extra Rate For Fouth Floor
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Extra Rate For Fifth Floor
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For Fifth Floor
Extra Rate For First Floor
Extra for carriage of RMC/batch mixed concrete with transit mixture beyond 1st km .
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Extra Rate For Third Floor
Extra Rate For Fouth Floor
Extra Rate For First Floor
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Extra Rate For First Floor
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Diesel Engine Supply, installation, testing & Commissioning of pump model in back pull out design (end suction type) having 100mm suction, 80mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 56 BHP, 1800 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Electric Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED DIESEL ENGINE DRIVEN PUMPSET in back pull design having 125mm suction, 100mm delivery, CI casing, bronze impeller, C-40 shaft with gland packed arrangement coupled on common MS fabricated baseframe vertical water cooled diesel engine complete with 12 V battery start arrangement, air cleaner, exhaust silencer(without piping), fuel filter, developing 50 BHP at 1800 RPM. Engine with twin belt driven radiator and complete with engine starting panel, Battery & AVM pods. Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
Dressed or moulded two brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufacture guidelines.
Pressure Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED Pressure Pump having Discharge 450 LMP and maintain required pressure in Down Comer as required by engg. in charge cpmplete in all respect Total head : 60m Flow : 450 Ipm
Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect.
12.5 mm thick cement plaster 1:5
Extra Rate For Fourth Floor
20mm thick cement plaster 1:5 in two coat work
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
20mm thick cement plaster 1:4 in two coat work.
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4)
Extra Rate for Third Floor
Extra Rate for Fifth Floor
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
CC 1:2:4 with stone ballast
Providing/Collection and Laying sand filling laying in 15 cm layers, ramming, watering and consolidating including all leads complete as per specification and as per entire satisfaction of engineer-in-charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling.
ame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Extra Rate for First Floor
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for First Floor
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
20mm thick cement plaster 1:4 in two coat work
Extra Rate for First Floor
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Imp teak wood cup board chowkats including iron hold fasts, iron hinges corner straps, wooden knobs or handles fixed in position (Size 45 x 60mm).
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Imported Teak Wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) 30 mm thick
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Extra Rate For Fouth Floor
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Extra Rate For Fifth Floor
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For Fifth Floor
Extra Rate For First Floor
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Extra for carriage of RMC/batch mixed concrete with transit mixture beyond 1st km .
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Extra Rate For Third Floor
Extra Rate For Fouth Floor
Extra Rate For First Floor
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Extra Rate For First Floor
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Diesel Engine Supply, installation, testing & Commissioning of pump model in back pull out design (end suction type) having 100mm suction, 80mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 56 BHP, 1800 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Electric Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED DIESEL ENGINE DRIVEN PUMPSET in back pull design having 125mm suction, 100mm delivery, CI casing, bronze impeller, C-40 shaft with gland packed arrangement coupled on common MS fabricated baseframe vertical water cooled diesel engine complete with 12 V battery start arrangement, air cleaner, exhaust silencer(without piping), fuel filter, developing 50 BHP at 1800 RPM. Engine with twin belt driven radiator and complete with engine starting panel, Battery & AVM pods. Total head : 60m Flow : 137 m^3/hr(2280 Ipm)
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
Dressed or moulded two brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufacture guidelines.
Pressure Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED Pressure Pump having Discharge 450 LMP and maintain required pressure in Down Comer as required by engg. in charge cpmplete in all respect Total head : 60m Flow : 450 Ipm
Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect.
12.5 mm thick cement plaster 1:5
Extra Rate For Fourth Floor
20mm thick cement plaster 1:5 in two coat work
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
20mm thick cement plaster 1:4 in two coat work.
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. (14.135)
Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 12mm to 15mm Slabs sizes above 0.50 sqm
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Extra labour for projected nosing of stair case of any shape and design
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4)
Extra Rate for Third Floor
Extra Rate for Fifth Floor
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
CC 1:2:4 with stone ballast
Providing/Collection and Laying sand filling laying in 15 cm layers, ramming, watering and consolidating including all leads complete as per specification and as per entire satisfaction of engineer-in-charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
ame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Extra Rate for First Floor
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for First Floor
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
20mm thick cement plaster 1:4 in two coat work
Extra Rate for First Floor
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Imported Teak Wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) 30 mm thick
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer- in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type
CC 1:2:4 with stone ballast
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position.
Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications
Providing & fixing Basketball pole pairs made of MS standard size complete in all respects. (Fixed Type)
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 (i))
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material (14.3)
Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material). (14.6)
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. (15.10)
CONSTRUCTION OF BASKET BALL COURT
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type
CC 1:2:4 with stone ballast
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position.
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Providing/Collection and Laying sand filling laying in 15 cm layers, ramming, watering and consolidating including all leads complete as per specification and as per entire satisfaction of engineer-in-charge.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
wo or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Supply and Fixing of Tensile Sheet Shed 650GSM sheet with M.S Iron pipe sqm 0 5194 5194 Frame Pole 125mm Heavy Truss M.S Pipe 60mm Heavy, Membrane M.S Pipe 50mm Heavy, Complete With cost of Painting and Labour for Fixing Paint Complete in all respects
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect
Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.
Precast Cement Concrete Kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Construction of Admin Block
Extra Rate For Third Floor
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Waterproofing of wet areas (Concrete/ Masonary Surface ) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating ( DR. FIXIT FASTFLEX / Equivalent ) to provide tough film build up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning, washing and removing dust,dirt and loose particles from concrete / masonary surface complete in all respects.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (10.16)
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure
Centring and shuttering for Columns ( Square or Rectangular or plygonal in plain) in superstructure
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 18.18
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. 11.6
12.5mm thick cement plaster 1:5. (15.10)
20 mm thick cement plaster 1:5 in two coats work. (15.21)
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with t
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
CC 1:2:4 with stone ballast
Iron grated doors, including pintle hinges & arrangements.
Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing
Providing and fixing false ceiling at height upto 4 mtr with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 1912SUB HEAD : 26- N 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate.
Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects.
Construction of Warden Residence
Hydrant Panel Providing & fixing of Hydrant Electrical Panel of cubical type floor mounted power cum control of Jockey Pump 1 No. & Electrical Pump 1 No. having MCCB 400 Amp 3 Pole 36 KA, MCCB 180 Amp 3 Pole Contactor 110 Amp. Contactor 180 Amp Realy 66-110, Realy 14-23,SSP ,SP,MCCB 63 Amp, 3 Pole, Digital Meter Set, Hardware, Aluminium Bus bar Set, Wire & Thimble, Panel Box 16 Gouge. Complete in all respect.
Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical
Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer.
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge.
Construction of Store Rooms
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete ISI designation no I (Size of door up to 700mm)
Construction of Security Rooms
100mm i/d Sluice Valves flanged
Sub Work-6
Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
Irrigation
Construction of Outer Development & Parking
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete
Wiring light point with double control switches.
Providing, laying, spreading and compacting stone ggregates of Grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (CSR 24.12 (i))
Applying priming coat with metal primer onnew steel or iron work including preparation of surface.
Construction of Boundary Wall
Dismantling brick work tile, masonry or tile lining In cement
Credit of Brick work
Credit of Brick Bat
Providing Internal Electrical Installations:
POINT WIRING:
Wiring fan point with sheet metal fan box
Wiring light point
Wiring call-bell point
Wiring 3 pin 6 Amp. wall socket point
Wiring 3 Pin 6 Amp. Plug control comprising wall socket point
Wiring 3 pin 16/20 amp. power plug control point
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
Bakelite Batten Holder (Large size)
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
Call Bell 220/230 volts AC Ding Dong
LED'S FIXTURES & FANS:
Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respect
s as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
75mm o/d PVC pipe of 4 Kgf. / sqcm
Ceiling Rose (Flush Piano type)
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Overall size 1sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of LED Flood Light 250 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and installation of pop up sprinklers
Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)
Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
Supply and erection of Wall Fan Plastic Body 400MM, 16" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Overall size 16sq.mm (Un-sheathed)
Pop up geared rotors 3/4" inlet and radius ranging from 7-12 m with interchangeable nozzles and all accessories omplete and setting flow rate as directed.
MCB Single Pole 6-32amp. (10kA, Curve-C)
Overall size 2.5sq.mm (50/0.25mm), 3Core
Cable End Box for TPN Vertical 4/8/12Way
MCB Four Pole 50, 63amp. (10kA, Curve-C)
OCCUPANCY SENSORS:
Supply and erection of Ceiling mounted Occupancy based PIR sensor (360 degree)with installation height 2.5mts ,8.5 Amps resistive load, Detection dia 8M,time delay - 5s to 59 mins , Light level threshold - 5 to 1275 Lux ,IP - 20,Sensitivity Adjustment, Walk LED test, with additional options like walkthrough, daylight set point, vacancy .
SUSPENSION RODS FOR CEILING FANS:
Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan.
CONDUIT PIPE & COPPER WIRES:
Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed
Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed
MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
12.5mm thick cement plaster 1:4.
Overall size 4sq.mm (Un-sheathed)
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Overall size 6sq.mm (Un-sheathed)
Overall size 25sq.mm (Un-sheathed)
SUB DISTRIBUTION SYSTEM:
Supply and installation of filters/ pressure relief valve for drip/ sprinkler system
TP&N Vertical Double Door Distribution Board 4 way each.
TP&N Vertical Double Door Distribution Board 8 way each.
Disc filter 50 cum/hr, with flush valve
Providing, fixing and jointing ISI Marked GunMetal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete 65mm i/d Gun Metal peet valve heavy pattern.
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
Sub Work-7
MAIN DISTRIBUTION SYSTEM:
Sub Head - 1 Construction of Swimming Pool
Note: The Contractor will submit Structural design & drawings for swimming pool as per IS 6494: 1988 & IS 3328:1993 & NBC 2016, which must have vetting from Reputed Engineering Institute, before execution. (Note :- Payment will be made as pe
RISING MAIN: (IN ELECTRICAL ROOM)
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Overall size 6sq.mm (Un-sheathed)
EMERGENCY RISING MAIN:
Supply, Installing testing and commissioning of 100A, 25KA Air Insulated Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every meter, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required complete in all respects as approved and desired by the Engineer-in-charge at site.
Pop up geared rotors 3/4" inlet and radius ranging from 7-12 m with interchangeable nozzles and all accessories omplete and setting flow rate as directed.
Cable End Box for TPN Vertical 4/8/12Way
MCB Four Pole 50, 63amp. (10kA, Curve-C)
Supply, installation, testing & commisioning of 125 Amp Main End Feed Unit Box (with provision of MCCB but without MCCB )on the existing Air Insulated rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C supply with Flange End, Rotary Handel, box made with 1.6mm thick G.I sheet steel enclosure (IP54) duly powder coated complete in all respects as approved and desired by the Engineer-in-charge at site.
NORMAL RISING MAIN:
Construction of Swimming Pool in RCC Frame Structure complete as per specifications
Supply, Installing testing and commissioning of 200A, 25KA Air Insulated Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessa
ry joints & expansion joints, fire barrier at each floor, provision of tapping at every meter, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, installation, testing & commisioning of 200 Amp Main End Feed Unit Box (with provision of MCCB but without MCCB )on the existing Air Insulated rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C supply with Flange End, Rotary Handel, box made with 1.6mm thick G.I sheet steel enclosure (IP54) duly powder coated complete in all respects as approved and desired by the Engineer-in-charge at site.
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage, using concrete mixing volumetric type
MCB Four Pole 40amp. (10kA, Curve-C)
Aluminium thimble cable Core size 70sq.mm
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
Supply, installation, of Tap off box for with provision of MCCB Four Pole 40-63Amp. (Excluding MCCB Cost) complete in all respects as approved and desired by the Engineer-in-charge at site.
MCCB Four Pole 63amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Cement Concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-
PVC flexible pipe 40mm dia.
Cement concrete 1:4:8 With brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type CSR 10.10 b ii
PVC compression Socket gland 40mm dia.
INDOOR LT PANELS:
MAIN LT PANEL:
SUB LT PANEL (EMERGENCY):
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and without vibrator but excluding steel reinfrorcement centring and shuttering in foundation and plinth
MCCB Four Pole 40/63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters butresses etc.)
MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
On Load Change Over Switch Four Pole 250amp., 415volts
EARTHING SYSTEM (INDOOR):
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
Additional Length 20mm x 3mm thick Copper Tape .
Additional Length 25mm x 3mm thick Copper Tap
INDOOR LT CABLES, CABLE TRAY, DWC PIPE , BRASS GLANDS & THIMBLES:
Overall size 6sq.mm (2Core) Un-armoured (Loose)
Overall size 16sq.mm (4 Core) Un-armoured (Loose)
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
Overall size 120sq.mm (3½ Core) Un-armoured (Loose)
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Aluminium thimble cable Core size 10 -16sq.mm
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
Additional Length 20mm x 3mm thick Copper Tape
Aluminium thimble cable Core size 25 -35sq.mm
Overall size 150sq.mm (3½ Core) Un-armoured (Loose)
Aluminium thimble cable Core size 120sq.mm
Overall size 240sq.mm (3½ Core) Un-armoured (Loose)
Cable Tray Size 300mm x 50mm x 50mm (2mm thick)
Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)
Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.)
Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.)
Double Walled Corrugated HDPE Pipe 180/152mm (Outer/ Inner dia.)
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-
Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm
Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm
Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.mm
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
12.5 mm thick cement plaster 1:3
Brass Gland for Aluminium cable 3/3½/4 Core size 70sq.mm
Providing and fixing glass mossaic tiles on finished plain wall surface of size 20mm x 20mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineer-in-Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:
Brass Gland for Aluminium cable 3/3½/4 Core size 95-120sq.mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filter of desired shade (0.10 kg of hardener and 0.20 kg of resin pre kg), including filling/ grouting and finishing complete as per direction of Engineer-in-Charge. Size 600 x 600 mm.
Brass Gland for Aluminium cable 3/3½/4 Core size 150sq.mm
Waterproofing of wet areas (Concrete/ Masonary Surface) and any water retaining structures such as simming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating (DR. FIXIT FASTFLEX/ Equivalent) to provide tough film build- up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning, washing and removing dust, dirt and loose particles from concrete/ masonary surface complete in all respects.
Brass Gland for Aluminium cable 3/3½/4 Core size 240sq.mm
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Cement Concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type
Providing and laying Mat finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Mat finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Sub Head-2 Filteration unit
MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Design, manufacture supply & installation of filteration unit, pump set & other equipment of Swimming Pool
Aluminium thimble cable Core size 50sq.mm
Note: The Contractor will submit suitable Design & technology for filtration unit of swimming pool including pumps as per IS 6494: 1988 & IS 3328:1993 & NBC 2016 & DWSS requirements before execution.
Overall size 2.5sq.mm (10 Core)
Design, Providing, Installation & commissioning of filteration unit of Swimming Pool, filter media, Pump set, Nano tech ultra voilet unit, Floor inlet, Return Nozzle, main drain cover, grating start board ladder shallow depth, ladder deep depth, cleaning kit (1 set), suction sweeper trolley set (1 set), electrical panel LED under water lights including cost of plumbing material special fitting electrical wiring, labour for installation including cost of all material as per requirement at site & as desired by Engineer-in-Charge.
Aluminium thimble cable Core size 4 - 6sq.mm
Aluminium thimble cable Core size 150sq.mm
Sub Head-3 Marking Of Lanes Etc.
Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-
Providing, Installation & commissioning of starter plates of stainless steel, Marking of lanes as per FINA guidelines , ropes with ability wave absorption etc making swimming pool national sports standard as per FINA labour for installation including cost of all material as per requirement at site & as desired by Engineer-in-Charge.
Copper thimble cable Core size 4 - 6sq.mm
Copper thimble cable Core size 10 - 16sq.mm
S/E of LT Cast Resin type/ Heat Shrinkable Termination Kit for Outdoor/ Indoor supply of 1.1 KV grade PVC/XLPE cable as desired by the Engineer in charge of the site:-
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
12.5mm thick cement plaster 1:4.
Pop up geared rotors 3/4" inlet and radius ranging from 7-12 m with interchangeable nozzles and all accessories omplete and setting flow rate as directed.
MCB Single Pole 6-32amp. (10kA, Curve-C)
Heat Shrinkable Outdoor/ Indoor End Termination Kit for Cable Size 3½/4 Core 225-300sq.mm
POINT WIRING:
SAFETY EQUIPMENTS:
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Brass Gland for Aluminium cable 3/3½/4 Core size 150sq.mm
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating
Brass Gland for Aluminium cable 3/3½/4 Core size 240sq.mm
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Cement Concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type
Providing and laying Mat finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Mat finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Sub Head-2 Filteration unit
Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. (755+20%)
Aluminium thimble cable Core size 50sq.mm
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Overall size 2.5sq.mm (10 Core)
Design, Providing, Installation & commissioning of filteration unit of Swimming Pool, filter media, Pump set, Nano tech ultra voilet unit, Floor inlet, Return Nozzle, main drain cover, grating start board ladder shallow depth, ladder deep depth, cleaning kit (1 set), suction sweeper trolley set (1 set), electrical panel LED under water lights including cost of plumbing material special fitting electrical wiring, labour for installation including cost of all material as per requirement at site & as desired by Engineer-in-Charge.
Aluminium thimble cable Core size 4 - 6sq.mm
Aluminium thimble cable Core size 150sq.mm
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-
Providing, Installation & commissioning of starter plates of stainless steel, Marking of lanes as per FINA guidelines , ropes with ability wave absorption etc making swimming pool national sports standard as per FINA labour for installation including cost of all material as per requirement at site & as desired by Engineer-in-Charge.
Copper thimble cable Core size 4 - 6sq.mm
Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
S/E of LT Cast Resin type/ Heat Shrinkable Termination Kit for Outdoor/ Indoor supply of 1.1 KV grade PVC/XLPE cable as desired by the Engineer in charge of the site:-
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
12.5mm thick cement plaster 1:4.
Pop up geared rotors 3/4" inlet and radius ranging from 7-12 m with interchangeable nozzles and all accessories omplete and setting flow rate as directed.
MCB Single Pole 6-32amp. (10kA, Curve-C)
Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
POINT WIRING:
Providing and fixing H.T. danger notice plate of 250 mm x 200mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
Providing and fixing M.V. danger notice plate of 200 mm x 150mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-
Providing Flood Lighting in 3Nos. Basketball Ground:
Galvanized Octagonal Pole Overall Length 12 metre (Sheet thickness 3mm), Top dia.(A/F) 90mm and bottom dia. (A/F) 240mm, Foundation size below G/L 650mm x 650mm x 2200mm, 4Nos. Foundation Bolts size 24mm dia., Length≥850mm with Base Plate Dimensions 320mm x 320mm x 20mm Thick
Supply and erection of M.S. Channel bracket made from 100mm x 50mm of length 600mm and height 600mm with M.S. angle iron 40mm x 40mm x 5mm for installing metal halide flood light fitting on it. Bracket should be fixed/ welded with the existing pipe of cover shed. The bracket should be painted with one coat of primer and two coats of approved paint.
INDOOR LT CABLES, CABLE TRAY & DWC PIPE:
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length)
Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface)
GI Earth rod 20 mm dia. 3 mtr. Long
Cubical Size 1200mm high, 900mm wide and 350mm deep with platform dimensions 1000mm x 450mm x 450mm
MAIN VERTICAL DISTRIBUTION BOARD : (To Control the 36 Nos.Flood Lights)
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB'
s as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-
MAIN VERTICAL DISTRIBUTION BOARD : (To Control the 36 Nos.Flood Lights)
Flood Lights 250W: (36Nos. Flood Lights for 1No. Basketball Ground)
Providing Flood Lighting in 3Nos. Volleyball Ground:
MAIN VERTICAL DISTRIBUTION BOARD : (To Control the 36 Nos.Flood Lights)
Cement Concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type
MAIN VERTICAL DISTRIBUTION BOARD : (To Control the 24 Nos. Flood Lights)
Providing, laying, spreading and compacting stone aggregates of Grading I to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8- 10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (CSR 24.11 (i) )
Flood Lights 250W: (24Nos. Flood Lights for 3Nos. Volleyball Ground)
Sub Head-2 Filteration unit
MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
Supply, Installing testing and commissioning of 200A, 25KA Air Insulated Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessa
Providing Advance Lightning Protection System:
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
12.5mm thick cement plaster 1:4.
Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm
Supply and installation of pop up sprinklers
Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)
Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply, erection, testing & commisioning of Early Streamer Emission (ESE) type Lightning Protection Complete with Lightning Air Terminal. The System should be corrosion resistant stainless steel chrome body capable of working in hazardous atmosphere and protecting against direct Lightning point as well conducting /diverting it to earth completely after tracing the Lightning in advance. As per NF C 17-102:2011 the air terminal should be tested for Lightning impulse current (10/350 micro sec) =100 KA and for local certification the air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) as per CPRI with 5 positive and 5 negative impulse. The ESE Terminals shall offer a protection radius of 79mtr., Level-1 High Protection and preferably to be mounted on roof top and center of the building / blocks with the highly insulated polyplastic adaptor with the Mast. (Its working principle evolves from local electrostatic field that develops naturally around the system as a thunderstorm begins to gather. In the event of descending lightning, an inbuilt triggering device generates high tension pulses at the conductor tip, causing a ‘corona effect’.) Protection radius of 79Mtr at level 1 & 107 Mtr at level 4
Pop up geared rotors 3/4" inlet and radius ranging from 7-12 m with interchangeable nozzles and all accessories omplete and setting flow rate as directed.
MCB Single Pole 6-32amp. (10kA, Curve-C)
Heat Shrinkable End Termination for cable size 50-95 sq. mm, 3Core (Indoor Type)
Supply and fixing of GI Mast 5 mtr. height along with suitable base plate for mounting the terminal along with highly insulated adopter to mount ESE Air Terminal with the Mast.The Adapter shall have suitable Metal connector /Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conducto, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required.
Supply and installation of Lightning Strike Counter (6 digit display) of non-resettable (electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system. This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures. It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs. above the ground level.
Supply & erection of test Link of non-corroding, weather proof, water proof polycarbonate IP 65/55 enclosure including providing of 2 Nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire. The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor.
Supply, installation & testing of chemical earthing (Maintenance Free Earthing) system with UL approved copper bonded rod and exothermically welded copper busbar both tested by CPRI at 50kA Fault Current. A copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper coating thickness of minimum 250 microns. Along with earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A copper clad steel solid ground wire of 8 mm dia. for interconnecting earth pits. Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber. The grounding minerals should not be pollute the ground water. The grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr.
Cost of pole foundation with earth work in excavation in foundations trenches etc. 0.25 meter below ground level, Cement Concrete 1:4:8 with stone ballast, Reinforced cement concrete M-20,Cold twisted deformed (Ribbed/tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 complete in all respect as desired by engineer in charge.
Overall size 70sq.mm (Un-sheathed) (Conductor connected the air terminal to earthing)
Providing 1No. 13Passenger, 3Stops Lift for Admin Block, 1No. 13Passenger, 2Stops Lift for Indoor Sports Hall and 1No. 13Passenger, 5Stops Lift for Hostel Block:
Admin Block: 1No. 13Passenger, 3Stops Lift
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
LED'S FIXTURES & FANS:
Other Features: 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28. The use of visually and accoustically reflective wall surace should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impairements. 29. The floor of lift car should be slip resistant and have similar frictional qualities to thye floor of lift landing to decrease the risk of stumbling. 30. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight. 31. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.
Indoor Sports Hall: 1No. 13Passenger, 2Stops Lift
Hostel Block: 1No. 13Passenger, 5Stops Lift
Overall size 16sq.mm (4Core) Un-armoured (Loose)
Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
Cable End Box for SPN 8 Way
Providing Networking System along with allied accessories:
Supply, Installation and Comissioning of Distribution Switch with minimum usable 24 10/100/1000BASE-T ports, 2 10GBASE-T ports , 4 10G SFP+ ports L3 Stackable Managed Switch with Redundant Power Supply Support.1 x RJ45 console port, RJ-45 port for out-of band-management port for accessing the CLI of the switch and USB port. 168 Gbps Switching capacity or higher or non-blocking architecture. 64 Bytes packet forwarding rate should be 125 Mpps or higher. Switch MAC table should be at least 16K or higher. Physical Stacking up to 9 units per stack. Stacking bandwidth up to 80G and up to 32 devices per virtual stack. Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol and ERPS as per standard ITU-T G.8032. BPDU Filter, BPDU restriction, Root restrction. Loopback detection (LBD). IGMP Snooping v1/V2/V3 & IGMP groups 1K or more IGMP groups and require support for IGMP Snooping Fast Leave. MLD Snooping v1/v2 & MLD group 1K or more and require support for MLD Snooping Querier. 16 L3 IP interfaces and IPv4/IPv6 Loopback interface. IPv6 Neighbor Discovery (ND). VRRPv3, Equal-Cost Multi-Path (ECMP) and UDP helper. Static route for both IPv4 and IPv6, OSPFv1, v2 & v3, RIP V1/V2/ng. Should have Policy-based Route (PBR). IEEE 802.1Q VLAN with different type of VLAN like Port based, Voice VLAN, Private, Double (Q-In-Q), Multicast VLAN (ISM VLAN for IPv4/IPv6), 802.1v Protocol VLAN ,VLAN Trunking. should have per-port broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance. port security to secures the access port based on MAC address. Require prevention of DoS attacks, which include Land, Blat, TCP Null Scan, TCP Xmas Scan, TCP SYNFIN, Ping of Death Attack and TCP Tiny Fragment attack. DHCP snooping and DHCP server screening, DHCP server. 802.1X port based and 802.1X host based access control, Identity-driven Policy (VLAN, ACL or QoS) Assignment. RADIUS and TACACS+ authentication. Authentication database failover. QoS (quality of service) IEEE 802.1P for traffic prioritization. 8 queues per port. Different type of QoS priority like Strict Priority Queue and Weighted Round Robin, Strict + WRR, Congestion control using Weighted Random Early Detection (WRED) or WTD. Remark 802.1p priority, Remark ToS/DSCP and Rate limiting in Policy map. Support at least 2K ingress & 512 egress access control entries. ACL based on MAC, IPv4 and IPv6, TCP/UDP port number, User-defined packet contentm, CPU Interface Filtering. Able to manage trough Web-GUI, Fully functional CLI interface and Telnet. Should have multiple Image and configuration support to reduced down time for the switches. sFlow for monitoring traffic in data networks, SNMP v1, v2c, v3 and SNMP Traps and RMON. Support for DHCP Client support for IPv4/IPv6, DHCP server, DHCP Relay and DNS client. Should have SNTP/NTP protocol for time synchronization. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED.. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED. Operating temperature should be 0 to 50 ˚C. Switch should be EMI Certificates FCC, CE and Safety Certifications cUL/UL, CB. All Switches, Wireless and its Networkiing Components from Same OEM. OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards. OEM should have Indian based operation at least for a period of 20+ years and should have an Annual Turnover of Rs. 500 Crores and above in any of last three consecutive Audited Financial years. (To ensure only principal networking companies participate having strong
Product , Support and Service.) complete in all respect as per satisfaction of the Engineer in charge of the work.
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
LED'S FIXTURES & FANS:
Supply, Installation and Comissioning of Patch Panel should be made of cold rolled steel.Should conform to TIA / EIA 568-C.2 Component Compliant.Should terminate 24 UTP CAT 6 (4 pair) Cables.Should confirm to EIA/TIA 568A wiring Pattern.Each port Should be features the spring-loaded shutter.Should be prevents incomplete mating Should be protects from dust and contaminants.Should be Front and rear port labelling as well as panel identification label.Should be Integral cable management shelf ensures bend radius compliance.Operating Life should be minimum 750 insertion cycles.Should be RoHS compliant.complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation and Comissioning of Patch Cord 1 Mtr Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant. complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation and Comissioning of Patch Cord 2 Mtr. Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing and Commissioning of 27U Network Enclosure Frame-600X800-STEEL with accessories like fan, pdu, cable manager etc. Supply of 27U Enclosure Frame-800X1000-STEEL, Caster Wheels Set of 4 (2 with Brakes & 2 without Brakes),Adjustable Levellers set of 4, Glass Door-800-27U, Metal Door-800-27U-Vented, Side Panels-1000-27U-Vented, Mounting Hardware-(Pack of 20), FHU with 4 FAN 360CFM, Vertical Power Distribution Unit with 12 x 5/15 sockets Round Pin, 230 Volts AC, 32 Amp with Plug, Vertical Cable Manager-27U-Loop, Horz. Cable Manager-1U-Loop, Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility maximizing the usable mounting space, Depth adjustable mounting slots, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with pretreatment process meeting all industry standards, Grounding and Bonding Options can be provided, 100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment, Conforms to DIN 41494 or equivalent standard, Welded Frame, Lockable Toughened Glass Door, Metal Vented Door Steel, DIN Standard 10mm Sq. Slots / Direct M6 Tap, 19” Mounting angles made of formed steel Powder Coated, Welded to Frame, Vented and Field Cable entry exit cut outs complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 36v, Efficiency : Above 90% complete in all respects as approved and desired by the Engineer in-charge at site.
Wiring Networking socket point RJ45 (one module)
CAT 6 LAN cable
Providing CCTV System:
Supply, erection, testing & commissioning of Indoor STQC Approved 3 MP IP WDR IR Rugged Mini Dome Camera OPERATIONAL: Video Standard: NTSC / PAL, Scanning System: Progressive, Image Sensor: 1/2.7” CMOS, Sensor Size (H x V): 4.608 mm x 2.592 mm, Number Of Pixels (H x V): 2304 x 1296, Minimum Illumination (Color/BW): .005 Lux / F1.6 (Color, 30 IRE), 0 Lux / F1.6 (IR ON), S/N Ratio: 50 dB, Electronic Shutter Speed: 1/8 ~ 1/32,000, IR Distance: up to 40 m, IR Light Control, Smart IR ( Auto / Manual ) / OFF, IR Light Number: 2, Day/Night: Auto (ICR) / Color / BW, Backlight Compensation: WDR, BLC, HLC, White Balance: Auto/Tungsten/ Fluorescent/ Daylight/Shadow/Manual, Gain Control: 0-100%, Wide Dynamic Range: 120 dB, Noise Reduction: 2D / 3D DNR, Lens: : 2.8 mm Fixed Iris, F1.6, Angle Of View: H: H:88°°, V:47°, Privacy Masking: Off / On (4 Areas), Defog: Not supported, Local Storage: Micro SD (up to 256 GB), Alarm Inputs/Outputs: Not supported, Pan Range: 0°-330°, Tilt Range: 0°-75°, Rotation Range: 0°-337°, Video Compression:H.265 HEVC/H.264/MJPEG, Smart Codec, Resolution: 1st: 2304 x 1296 / 1920 x 1080 / 1280
x 720 2nd: 704 x 576 (PAL) / 704 x 480 (NTSC) / 640 x 480 / 352 x 288 (PAL) / 352 x 240 (NTSC) 3rd: 640 x 480 / 352 x 288 (PAL) / 352 x 240 (NTSC) / 320 x 240, Number of Video Streams: 3 (2 for encryption), Frame Rate*: MAX 30 fps, Bit Rate*: 100K ~ 6 Mbps, Audio Compression: Not supported, Audio Stream: Not supported, Audio Interface: Not supported, NETWORK: Ethernet: 10 Base-T/100 Base-TX Ethernet (RJ-45), Supported Web Browsers: Chrome / Edge, Supported OS: Microsoft Windows 10, Protocols**: IPv4, IPv6, TCP / IP, HTTP, HTTPS, RTSP / RTP / RTCP, IGMP / Multicast, SMTP, DHCP, NTP, DNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS, Interoperability: ONVIF Profile G/S/T, Maximum Users Access: 10 Users, Security: User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES128 / 256, SSH / Telnet closed, PCI-DSS compliance, EVENTS / ANALYTICS: Built-in Video: Analytics, Motion Detection, Tampering, Event Type: Video motion detection,Recording notification, Event Linkage: Event notification using Email and MicroSD card, Region Of Interest: 8, ELECTRICAL: Power Supply: DC12V, PoE (IEEE 802.3af) (Class 0), Power Consumption (Max): MAX 3.6 W, MECHANICAL: Dimensions: Ø110.0 mm × 85.6 mm (Ø4.33” × 3.37”), Dome Diameter Ø78.2 mm (3.08”), Product Weight 0.56 kg (1.23 lb), Package Weight 0.65 kg (1.43 lb), Body Material Die-cast aluminium housing, ENVIRONMENTAL: Operating Temperature: Starting Temperature:-40°C ~ 60°C (-40°F ~ 140°F), Working Temperature: -40°C ~ 60°C (-40°F ~ 140°F), Relative Humidity Less than 90 %, non-condensing, Ingress Protection IP67, Impact Resistance IK10, REGULATORY: Emissions: FCC PART 15, CE (EN 55032), Complies with RCM and UKCA, Immunity CE(EN 50130-4), Complies with RCM and UKCA, Safety: UL LISTED TO UL/CSA 62368-1, CE(EN 62368-1), Complies with RCM and UKCA, RoHs: CE(EN 63000) complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, erection, testing & commissioning of Outdoor STQC Approved 3MP IP WDR IR MFZ Bullet Camera OPERATIONAL; Video Standard: NTSC / PAL, Scanning System: Progressive, Image Sensor: 1/2.7” CMOS, Sensor Size (H x V); 4.608 mm x 2.592 mm, Number Of Pixels(H x V): 2304 x 1296, Minimum Illumination (Color/BW); 0.005 Lux/F1.6 (Color,30 IRE), 0 Lux/F1.6 (IR ON), S/N Ratio: 50 dB, Electronic Shutter Speed: 1/8 ~ 1/32,000, IR Distance: up to 40 m, IR Light Control: Smart IR (Auto / Manual) / OFF, IR Light Number: 4, Day/Night: Auto (ICR) / Color / BW, Backlight Compensation:WDR, BLC, HLC, White Balance Auto/Tungsten/ Fluorescent/ Daylight/Shadow/Manual, Gain Control: 0-100%, Wide Dynamic Range: 120 dB, Noise Reduction: 2D/3D DNR, Lens: 2.8mm Fixed Iris F1.6, Angle Of View: H:88°, V:47°, Privacy Masking: Off / On (4 Areas), Defog: Not supported, Local Storage: Micro SD (up to 256 GB), Alarm Inputs/Outputs: Not supported, Video Compression: H.265 HEVC/H.264/MJPEG, Smart Codec, Resolution: 1st: 2304 x 1296 / 1920 x 1080 / 1280 x 720 2nd: 704 x 576(PAL) / 704 x 480(NTSC) / 640 x 480 / 352 x 288(PAL) / 352 x 240(NTSC)3rd: 640 x 480 / 352 x 288(PAL) / 352 x 240(NTSC) / 320 x 240, Number of Video Streams: 3 (2 for encryption), Frame Rate*: MAX 30 fps, Bit Rate*: 100K ~ 6 Mbps, Audio Compression: Not supported, Audio Stream: Not supported, Audio Interface: Not supported, NETWORK: Ethernet: 10 Base-T/100 Base-TX Ethernet (RJ-45), Supported Web Browsers Chrome/Edge, Supported OS: Microsoft Windows 10, Protocols**: IPv4, IPv6, TCP / IP, HTTP, HTTPS, RTSP / RTP / RTCP, IGMP / Multicast, SMTP, DHCP, NTP, DNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS, Interoperability: ONVIF Profile G/S/T, Maximum Users Access: 10 Users, Security;User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES128 / 256, SSH / Telnet closed, PCI-DSS compliance, EVENTS / ANALYTICS: Built-in Video Analytics: Motion Detection, Tampering, Event Type: Video motion detection,Recording notification, Event Linkage: Event notification using Email and MicroSD card, Region Of Interest: 8, ELECTRICAL: Power Suppl
y: DC12V, PoE (IEEE 802.3af) (Class 0), Power Consumption (Max): MAX 5.5W, MECHANICAL; Dimensions: Ø87.0 mm × 197.3 mm Product Weight:.0.7 kg , Package Weight: 0.85 kg , Body Material Die-cast aluminium housing, ENVIRONMENTAL: Operating Temperature: Starting Temperature:-40°C ~ 60°C (-40°F ~ 140°F)Working Temperature:-40°C ~ 60°C (-40°F ~ 140°F) (IR off), Relative Humidity: Less than 90 %, non-condensing, Ingress Protection:IP67, Bullet Casing: IK10, REGULATORY: Emissions: FCC PART 15, CE (EN 55032), Complies with RCM and UKCA, Immunity: CE(EN 50130-4), Complies with RCM and UKCA, Safety: UL LISTED TO UL/CSA 62368-1, CE(EN 62368-1), Complies with RCM and UKCA, RoHs: CE (EN 63000). complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, erection, testing & commissioning of Outdoor STQC Approved 1/2.8 inch CMOS 2MP or better, IR PTZ Camera, Effective pixels 1920 x 1080, 2MP, 25 fps; 25x Optical Zoom & 16x Digital Zoom, tripple stream; IR distance: 150 meter; Lens type: Wide 5 to 6mm, Tele 125 to -150mm Motorized Auto focus zoom lens; Memory card slot: Min 256GB support. Minimum Illumination- Sense up on- Color: 0.005 lux color, B/W: 0 lux IR On, WDR 120dB, Edge Video Analysis Video Motion Detection, Intrusion, Lioter, Counter & Tampering, 3DNR, BLC, HLC, White Balance, EIS, Defog, Mechanical switchable IR filter (Auto ICR), Pan Range 360° continuous, Tilt Range -10° to 90°, Pan/Tilt Modes - Pan: 0.1°/s - 180°/s; Tilt: 0.1°/s - 90°/s, Presets 256, Preset Accuracy 0.25 Deg, 16 Patrol & Tours, Alarm I/O - 2In/2Out, 2-Way Audio- 1/1 Channel In/Out, 256GB Memory card slot, 4 individually configurable privacy masks, 8 Region of Interest, POE+ (802.3 at) or 24VAC 3A for indoor/Outdoor application, IP66/67, IK 10; Certifications: ONVIF Profile S/G/T/M Compliant (Can be verified from Onvif Website and T profile must have secure streaming), UL, CE, FCC, EN, RoHS & NDAA Section 889 compliant. complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, erection, testing & commissioning of 64 Channel NVR (Network Video Recorder shall be support the STQC Cameras) Embedded Linux based for recording upto 64CH at D1 with 08 nos. SATA HDDs minimum 80TB storage or more (recording requirement all cameras recording at D1, 25fps for 30 days), RAID 1/5/6 or better Up to 8 MP (4K) resolution live view and playback, Supports H.265 HEVC, H.264, Smart Codec decoding, Front Panel with LEDs Indication for Power & HDDs Status, USB Ports Front x 2, usb2.0; Back x1, usb3.0, ONVIF S, Time Sync with NTP, Encrypted Streaming & Control, 2-Way Audio Line & Out, Supported Protocols IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP/RTP/RTCP, SMTP, FTP, DHCP, NTP (Secure), DNS, DDNS, IP Filter, P2P, SNMPPTZ Operation Pan, Tilt, Zoom, Support, Pre & Post Alarm Recording Support, Recording/Evidence Clip Export to USB, 16 Channel Synchronous Playback, Playback control i.e Play, Pause, Stop, Fast Forward, Backward, Speed Control, Timeline & Zoom; Snapshot, Web Client, Central Monitoring Software, iPhone; iPad; Android based Mobile clients, Number Of Users 16 or better, TPM for end-to-end stream and command encryption through integrated cryptographic keys, HDMI 1 (4K Max), HDMI 2 (1080P), VGA x1 (1080P), 08 On Board HDDS each up to 10TB, Alarm Input (16 nos.), Alarm Output (6 nos.), Dual network ports, incoming bandwidth is 400 Mbps and outgoing bandwidth is 400 Mbps, NDAA Section 889 Compliant, Support redundancy Failover N+1,Operating Temperature –10°C to 55°C, Certification : Certifications: ONVIF compliant, PCI-DSS compliance, RS485, RS 232, Esata Supprted, UL, CE, FCC Part 15, EN, NDAA & RoHS compliant. Including fixing accessories and cable termination with required connectors/Jack. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, erection, testing & commissioning of Switches: 24 Ports 10/100/1000 Mbps PoE + 4 Ports 10G SFP+ Smart Managed Layer 2 Switch, Power budget 370W from day1, Support 802.3af/at), Switching Capacity 128 Gbps, MAC Address Table 16K, Packet Forwarding Rate, 95.24 Mpps, Flash Memory 64 MB, DRAM Size 256 MB DDR3, IGMP v1/v2/v3 Snooping & MLD snooping v1/v2, 802.3x Flow Control, HOL Blocking Prevention, LLDP/ LLDP-MED, 802.1D, 802.1W, 802.1s, 802.1Q, 802.1p QOS, SPQ, WRR, WDRR, Bandwidth Control, Static routing, IPv6 Neighbor Discovery (ND), ACL Max. 768 rules shared by IPv4, MAC, & IPv6, Traffic segmentation, ARP Spoofing Prevention, ARP Inspection, DHCP Snooping, MAC authentication, SSH v2, TLS v.1.2, DoS attack prevention, 802.1X Port-based Access Control, Port Security, RADIUS/TACACS+, MD5 authentication, GUI, Full CLI, Telnet Server, TFTP Client, MDI/MDIX, SNMP v1/v2c/v3. Internal/External 6 kV surge protection on all RJ-45 access ports, Operating Temperature -5 to 50°C, Storage Temperature -20 to 70°C, Operating Humidity 0% to 95% relative humidity, Certifiate: EMC EN 55032, Class A; EN 61000-3-2; EN 61000-3-3; EN 55024, Safety EN 62368-1, ROHS EN IEC 63000, 47 CFR FCC part 15: 2017, Subpart V, Class A, ICES-003, IEC 62368-1, IEC 60950-1, IEC 60950-1/AMD1, IEC 60950-1/AMD2, UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14. MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017, OEM Should be ISO 45001, ISO 27001 & ISO 14001 Certified, OEM Should have Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent) complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, erection, testing & commissioning of Switch 8 x 10/100/1000BASE-T PoE
Ports, 2 x SFP ports & RJ-45 console port. 802.3at PoE+ & 802.3af PoE power 130W, IEEE 802.3i 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab, IEEE 802.3az, IEEE 802.3x, IEEE 802.3z. 20 Gbps Switching Capacity & Packet Forwarding Rate 14 Mpps, 8K MAC address. DRAM Size DDR3 128MB, Flash Memory Size 32MB, Fanless Design, CPU Speed 500MHz. Packet Buffer Size 4.1MBits. Operating & Storage Temperature -5 to 50 °C & -40 to 70 °C. Operating & Storage Humidity 10% to 90% & 5% to 90%, Loopback detections. IGMP Snooping v1, v2 & MLD snooping v1/v2. IEEE 802.1AB LLDP & LLDP-MED. IEEE 802.3az (EEE), 4K VLAN ID's, Min 256 static VLAN, Multicast VLAN & Auto Voice & Video VLAN, Port Mirroring 1 x to one/Many to One, 802.1p Quality of Service (QoS), SPQ, WRR, Bandwidth Control, Static routing for inter-VLAN Communication, Access Control List (ACL), L2 & L3 ACL (IPv4 & IPv6), Broadcast/Multicast/Unicast Storm Control, Traffic segmentation, TLS, DoS attack prevention, 802.1X Port-based Access Control, Port Security, ARP Spoofing Prevention, DHCP Server Screening, IP-MAC-Port Binding, ARP Inspection, DHCP Snooping, 802.1X Authentication local/RADIUS database (IPv4 & IPv6), port-based access control, EAP, OTP, TLS, TTLS, PEAP & Support MD5 authentication, features Cable diagnostics, IPv4 & IPv6 Inspection, SSH v2 feature, 802.3x Flow Control & HOL Blocking Prevention, Management thru Web-based & CLI, SNMP v1/v2c/v3, NTP/SNTP, IPv4/v6 Dual Stack, Dual image, Dual configuration. Product Should Approved from TEC under Mandatory Testing & Certification of Telecom Equipment as notified vide Indian Telegraph (Amendment) Rules, 2017. CE, FCC, UL, IEC/EN 60950 & IPv6 Ready compliance. OEM Certification for ISO 45001, ISO 9001, ISO 14001, & ISO 14064-1, IEC 62443-4-1 complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, erection, testing & commissioning of Supply of Wall Mount 15U x 600 W x 600 D , Front Glass Door (tinted, Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC. as per DIN 41494 Standards. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, erection, testing & commissioning of HDD Formatted capacity 6 TB surveillance ,Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s,Cache (MB) 64,Rotational speed (RPM) IntelliPower ,Load/unload cycles4 300,000,Non-recoverable read errors per bits read <1 in 1014, Operating (2 ms, read/write) 30, Operating (2 ms, read)65, Non-operating (2 ms)250, Average power requirements (W) Read/Write 5.90,Idle 4.90,Standby and Sleep 0.40 complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, erection, testing & commissioning of Display : 50 inch, 4K (3,840 x 2,160), Direct LED, Professional Display with 4K Processor, Native Contrast ratio 5,000:1 or higher, Response time 12 ms or lower, Brightness 400 cd/m² or higher, 24/7, Portrait/Tilt functionality, HDMI Auto wake up, HTML5 platform, 16GB On Board Storage, HDMI*4 with HDCP 2.3 / RS232 / USB / RJ45 / Wi-Fi Direct / 20W Speakers / Android OS or similar, Viewing angle 178 degree, Apple AirPlay & Chromecast complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, Installation, Testing & Commissioning of 6 meter long superior quality 4K HDMI Cable having speed upto 10gbps support all types of HDMI Devices complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Providing Fire Detection/ Emergency Evacuation & PA System:
FIRE PANELS & ANNUNCIATORS:
Supply, installation, testing & Commissioning of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event , 1000 alarm log history events, Qwerty/ Touch Screen keypad for operation. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 250 analog addressable devices (Devices and detectors). The panel shall work in degrade mode in case of CPU failure, Products not having this feature will offer Redundant CPU. Four access levels, flash EPROM, Panel Shall include 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall support with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 5 Telephones in conference in multiple FFT Risers. The panel shall be expandable upto Min. 10 loop, UL & FM approved. Panel shall have provsion for Modbus/ Bacnet over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable for remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th. complete in all respects as approved and desired by the Engineer in-charge at site.
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:-
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work .
Supply, installation, testing & Commissioning of Loop Cards Class A Wiring with min. supporting cable length Up to 1.2 Km UL & FM Approved .complete in all respects as approved and desired by the Engineer in-charge at site.
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
LED'S FIXTURES & FANS:
Supply, installation, testing & Commissioning of Digital Voice Command Keyboard/ Touch Screen for local annunciation and controls; status LEDs and 24 user-programmable buttons.Display All Call, Page Active Evac Areas, Page Active Alert Areas, Page Inactive Areas UL Listed . The solution should be from single OEM.complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
LT Panel enclosure having space for 1No. Incomer MCCB 630Amp. and 6Nos. outgoing MCCB's 40amp. to 250amp. (Option: MCCB 200-250amp.= 2Nos. and MCCB's 40-100amp.= 4Nos.) according to the requirement at site (Approx. size 1475 x 1800 x 400mm) (DETAIL SEE IN PANEL INVENTORY)
Sub Head-2 Filteration unit
MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and without vibrator but excluding steel reinfrorcement centring and shuttering in foundation and plinth
MCCB Four Pole 40/63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
Overall size 6sq.mm (2Core) Un-armoured (Loose)
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Overall size 150sq.mm (3½ Core) Un-armoured (Loose)
Supply, installation, testing & Commissioning of Paging Microphone compatible with Emergency evacuation Control Panel UL Listed complete in all respects as approved and desired by the Engineer in-charge at site.
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm) (DETAIL SEE IN PANEL INVENTORY)
MCB Four Pole 40amp. (10kA, Curve-C)
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code : 15658(2006)
Supply, installation, testing & Commissioning of Addressable photo-Thermal multi criteria Detector and base with sensitivity range as per NFPA 72. The intelligent detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches. Designed to meet UL & FM Approved . The solution should be from single OEM. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min.NFPA 72. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches.UL & FM Approved The solution should be from single OEM.complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device complete in all respects as approved and desired by the Engineer in-charge at site.UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary / Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary/ Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device.UL & FM Approved Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM.complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary/ Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and Min.110 cd flashintg at 1 Hz for visual indication. UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply,installation, testing & Commissioning of Digital Audio Amplifier with cabinet & Amp power supply. Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of Min 95 W ( It may be 1 unit or Combination of Multiple units to achieve the Requirement) at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall (be Wall/Panel Mounted) Failure of Fire Panel CPU shall not result in failure of Amplifier operation. Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers shall provide back up of minimum 5 hours using secondary power source(battery power/UPS power) complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling/Wall Mount Speakers. The speakers shall be of the same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms UL Listed complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Back Box for 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling/Wall Mount Speakers as per site requirement complete in all respects as
approved and desired by the Engineer in-charge at site.
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary hand
le and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc
ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-
le and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc
Supply, installation, testing & Commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center UL Listed complete in all respects as approved and desired by the Engineer in-charge at site.
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
Supply, installation, testing & Commissioning of Addressable Fire Fighter's Telephone Jack for two way communication between Remote Fire Fighter & Fire Command Center UL Listed complete in all respects as approved and desired by the Engineer in-charge at site.
COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Sub Head-2 Filteration unit
MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
On Load Change Over Switch Four Pole 250amp., 415volts
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and without vibrator but excluding steel reinfrorcement centring and shuttering in foundation and plinth
MCCB Four Pole 40/63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Supply, installation, testing & Commissioning of Paging Microphone compatible with Emergency evacuation Control Panel UL Listed complete in all respects as approved and desired by the Engineer in-charge at site.
COPPER EARTHING :- (Upto 14 metre in Length):-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
MCB Four Pole 40amp. (10kA, Curve-C)
Aluminium thimble cable Core size 70sq.mm
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Supply, installation, testing & Commissioning of Chassis assembly enclousre for Fire fighter telehphone handset, UL Listedcomplete in all respects as approved and desired by the Engineer in-charge at site.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code : 15658(2006)
Aluminium thimble cable Core size 95sq.mm
Supply, installation, testing & Commissioning of Exi LED M ST LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED > 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Emergency LED NM LED IP42 230V 2X6W 1h/3h/8h. The luminiare comes in plastic housing. Mounting bracket is not required for this luminaire, IP42/NA 0 Non -Maintained Self Testing 12V / 7Ah Pb, LED based for anti-panic area, surface assembly Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch High lumen output – 1h = 360lm / 3h = 170lm / 8h = 70lm Simple and quick assembly and maintenance Technical lifetime of LED > 100 000 hours • IP42 – dust and waterproof luminaire, Voltage 220-240VAC / 50-60Hz Power consumption 11.4W / 11.8VA Battery 12V / 7Ah Pb Battery protection Over charge protection /deep discharge protection Charging Time 23 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source LED 2x6, Technical lifetime (light source) >100 000 hours, Lumen output, emergency (1h / 3h / 8h) 3200 / 1600 / 800 lm, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IP rating IP42, Dimensions 302 x 94 x 210 mm, Weight 4200 / 4420 gr, Materials PC/ABS, PC, Aluminium, Mounting method Wall mounting complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-
Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm
Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm
Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.mm
Supply, installation, testing & Commissioning of Online UPS 1 kva 800 Watts Tower UPS with 1 hour battery backup. Operating Temperature Range 0 to 40 Degree @ 100% Load @ 50 Degree with 50% Load,Storage Temperature -15°C~60°C, Relative Humidity 0-95% No condensates, Acoustic Noise 40 dBA @ 1 Meter, Cooling Forced air cooling by the internal fans, Input Socket IEC C13, Output Socket IEC C14, No of output sockets 3 No's, Rated Input Voltage 208/220/230/240 Vac, Maximum working input voltage range 160 to 300 Vac @ 100% Load, 100 to 300 Vac @ 50% Load, Input Power Factor 0.99, Input THDi% 5%, Generator Set Yes 1.5 x UPS Capacity, Rated kVA 1000 VA, Rated kW 800 Watts, Load type Resistive load/ lagging load/ non-linear load/ transformer load/ lighting load, Load power factor range 0.5~1 lagging, Load Crest Ratio 3:1, Online Efficiency 88%, Rated Battery Voltage 36 Vdc, Battery Type VRLA (Valve Regulated Lead Acid Battery), 12VDC, Battery backup Back UP : 936VAH, Maximum charging current 10 Amps, ECO Mode Available, Communication (Independent SCI) Available, Intelligent Card slot (Independent SCI) Available, OVCD Available, EPO Function Available, Intelligent Fans Speed control Available, Auto restart function Available, Cold start Available complete in all respects as approved and desired by the Engineer in-charge at site.
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
Overall size 1.5sq.mm (48/0.20mm), 2Core
Additional Length 25mm x 3mm thick Copper Tape
Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.)
Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Providing 1No. 125KVA Silent Diesel Generating Set:
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:
Overall size 1.5sq.mm (Un-sheathed)
Supply and erection of M.S. Channel bracket made from 100mm x 50mm of length 600mm and height 600mm with M.S. angle iron 40mm x 40mm x 5mm for installing metal halide flood light fitting on it. Bracket should be fixed/ welded with the existing pipe of cover shed. The bracket should be painted with one coat of primer and two coats of approved paint. (For Flood Lights in Swimming Pool)
SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement (For Flood Lights in Swimming Pool)
GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR: Supply and erection of Galvanized Steel Octagonal Pole (Sheet thickness 3mm) designed to withstand wind speed 169km/ hour of suitable length (Raw material confiming to IS-5986 (FE-510), BSEN-10025S-355J or ASTM-572A (GR-50)) and thickness of galvanization (70mm thick) conforming to IS:2629/ IS:2633/ IS:4759, BSEN-ISO-1461-1991 OR ASTM-A123/A123M-02. The pole shall be in single piece hot dip galvanized and shall be tapered towards the top. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level as required:- (4Nos. Pole for 1No. Basketball Ground)
M.S. FLAT/ CHANNEL BRACKETS: (Brackets for 12Nos. 12Mtr. GI Octagonal Poles)
Aluminium thimble cable Core size 240sq.mm
Overall size 16sq.mm (4Core) Un-armoured (Loose) (From Sub LT panel (Emergency) to 1No. Cubical Pedestal for 3Nos. Basketball Ground)
Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 125 KVA /100KW .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing 400 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-II Norms) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust r
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Brass Gland for Aluminium cable 3/3½/4 Core size 70sq.mm
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (From Cubical Pedestals to 36 Nos. Flood Lights)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- (From Cubical Pedestals to 36 Nos. Flood Lights)
Aluminium thimble cable Core size 4 - 6sq.mm
Aluminium thimble cable Core size 150sq.mm
GALVANIZED IRON PIPES AND G.I. EARTHING: Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). (2Nos. Earth for Cubical Pedestal)
Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
esidential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
Additional Length 20mm x 3mm thick Copper Tape .
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Aluminium thimble cable Core size 10 -16sq.mm
Providing, Installation & commissioning of starter plates of stainless steel, Marking of lanes as per FINA guidelines , ropes with ability wave absorption etc making swimming pool national sports standard as per FINA labour for installation including cost of all material as per requirement at site & as desired by Engineer-in-Charge.
Overall size 10sq.mm (3Core) Un-armoured (On-Surface)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
12.5mm thick cement plaster 1:4.
Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm
Supply and erection of LED Flood Light 250 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and installation of pop up sprinklers
Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
Pop up geared rotors 3/4" inlet and radius ranging from 7-12 m with interchangeable nozzles and all accessories omplete and setting flow rate as directed.
ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:-
Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- (12Nos. earth for Octagonal Poles)
COPPER EARTHING
MCB Double Pole 6-32amp. (10kA, Curve-C)
Providing 11 KV, 315KVA Sub Station:
VACUUM CIRCUIT BREAKER: IN SUBSTATION
Supply, Erection, Testing and Commisioning of 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) switch board unit 630 Amp. which includes 630/800 Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of 25kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 100 opeartion
VCB parameters are as below: (a). Rated Voltage: 12kV (b). Rated short circuit breaking current withstand : Min. 25kA for 3sec. (c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak (d). Rated insulation voltage( Power frequency withstand) : Min. 28kV (e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO (f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz) (g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) (h). Earthing Switch : Mechanically interlocked device to prevent personnel from getting electric shock during breaker maintenance. VCB incorporating mechanical as well as electrical ON/OFF indiaction "OFF" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door.
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: CUBICAL PEDESTAL: Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos
11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Switch board unit 630 Amp. which includes 1 No. 630 /800Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with in built power pack.
MCB Double Pole 40amp. (10kA, Curve-C)
Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications
TRANSFORMER 315KVA:
SP&N Double Door Distribution Board 8 way each
110mm o/d single socket SWR UPVC pipe lines laid complete
Supply, installation, testing and commissioning of 11KV/433V, 315KVA, Indoor/Outdoor type floor mounted Distribution Transformer, Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor conforming to IS:1180 (2014) Level-2 & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV (c). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C (f). Oil/ Winding temperature rise: As per IS:1180 (g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side (j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp The Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. Note: Manufacturer shall ensure that there is no mixing of second grade core. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:-
TRANSFORMER FOUNDATION:
90mm o/d single socket SWR UPVC pipe lines laid complete
Construction of RCC Foundation of size 8' x 8' x 2' height and covered the area 20' x 20' with fencing (1.8 metre height) around the RCC foundation for Transfomer 315KVA (Outdoor) as per desciption below: As per Drawing attached (i) Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m = 12.81Cum. (ii) Cement concrete 1:5:10 with 40 mm gauge stone ballast using concrete mixing volumetric type = 3.20 Cum. (iii) Reinforced cement concrete M-25 mechani
SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE: Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½" x 1½" size nut bolt fully threaded. The bracke
caly batch mixed using batch type concrete mixer as per IS:1791and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth = 6.34 Cum. (iv) Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) = 14.31 Sqm (v) First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth = 3.68 Cum (vi) Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material = 25.85 Sqm (vii) Conglomerate floor 50mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material) = 37.16 Sqm (viii) Laying of Dry stone Ballast 40 mm gauge for flooring = 1.81 Cum (ix) 1.8 meter high G.I. barbed wire fencing with 2.4 meter angle iron posts 50x50x6mm placed every 3 meters centre to centre 0.6 meter below ground level, every 15th post, end post, corner post suitably strutted and provided with 12 horizontal lines and two diagonals interwoven with horizontal wires fixed with GI staples, turn buckles etc. including foundation concrete 1:2:4 of size 0.30x0.30x0.75m for each post complete as per technical clause 808 of MORT&H specifications = 24.37 mtr. (x) Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete = 6.34Qntl. (xi) Applying priming coat with metal primer on new steel or iron work including preparation of surface.Vertical Post Angle Iron 50x50x6mm = 7.47 Sqm (xii) Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade= 7.47 Sqm complete in all rspect as desired by Engineer in charge of work.
Supply, installation, testing and commissioning of 11KV/433V, 315KVA, Indoor/Outdoor type floor mounted Distribution Transformer, Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor conforming to IS:1180 (2014) Level-2 & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV (c). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C (f). Oil/ Winding temperature rise: As per IS:1180 (g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side (j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp The Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. Note: Manufacturer shall ensure that there is no mixing of second grade core. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:-
TRANSFORMER FOUNDATION:
90mm o/d single socket SWR UPVC pipe lines laid complete
APFC FOR 315KVA TRANSFORMER:
HT CABLE, END TERMINATION KITS & CONTROL CABLE FOR TRANSFOMER:
S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:-
Heat Shrinkable End Termination for cable size 50-95 sq. mm, 3Core (Outdoor Type)
Earthing with 40mm x 5mm Copper Tape (upto 23Metre in Length)
Additional Length 40mm x 5mm thick Copper Tape
SUB STATION SAFETY EQUIPMENTS:
Providing Campus & Flood Lighting:
Overall length 7 metre, with planting depth 1.25 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2) and base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia.
Double Arm Bracket 1 metre Long for Steel Tubular Pole (7 to 8m)
Cement Concrete Muff of Overall Size 450mm dia., 80cm Long
Double walled corrugated (DWC) HDPE pipe 63/51mm (outer/ inner dia.)
For 90mm o/d pipes
Brass Gland for Aluminium cable 2/3/4 Core size 10sq.mm
MCB Triple Pole 6-32amp. (10kA, Curve-C)
Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)
Single Tee With Door
Single Tee With Door
Supply and erection of LED Flood Light 120 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Providing Solar Power Generation System:
ADMIN BLOCK, INDOOR MUTIPURPOSE HALL & HOSTEL BLOCK:
Grid interactive
PV System Solar Power Plant of 95KWp:
C.P.brass 15mm Angle valve without flange
Public Health WORKS
Sub Head-1 Internal Sewerage System
CPVC SDR 11 Pipe & fitting 32mm o/d
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
Vent Cowls
Coupler
Floor Trap 110mm x 110mm
Elbow 90 degree (all side socket)
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge)
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.
M.S. Holder bats clamps for 100mm i/d
M.S. Holder bats clamps for 75mm i/d
Core cutting in RCC slab 125mm dia or 150mm dia withe the help of core cutting machine as per requirement at site & as desired by Engineer-in-Charge.
Providing and fixing galvonised hanging clamp 100mm dia chimney type for PVC pipe, 12mm galvonised fully thread bar with nut bolt as per requirement at site & as desired by Engineer-in-Charge.
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm as per table-1
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
Sub Head-2 Internal Water Supply System
CPVC SDR 11 Pipe & fitting 16mm o/d
SDR 11 CPVC pipes & fittings 20mm o/d
CPVC SDR 11 Pipe & fitting 25mm o/d
CPVC SDR 11 Pipe & fitting 50mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm
GI P 15mm i/d to 25 mm
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Through wall 11.43 cm thick
Through wall 22.86 cm thick
20mm i/d Brass Ball valves
25mm i/d Brass Ball valves
40mm i/d Brass Ball valves
t should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thick triangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:-
50mm i/d Brass Ball valves
Sub Head - 3 Sanitary Installation
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm
For 110mm o/d pipes
Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineerin-charge ) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect.
32mm i/d Brass Ball valves
C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
Size 49 cm dia (above counter round)
Size 550 mm x 400 mm x 815mm
Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.
Construction of Plateform complete as per specification & as desired by Enginer-in-charge
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.
Double bowl Sink without drain board Overall size 1330x515 bowl size 560x410x200mm
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut
Single Arm Bracket 1 metre Long for Steel Tubular Pole (7 to 8m)
Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-in-charge) complete in all respect.
C.P. brass toilet roll holder with flap
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P. brass towel Rails size 15mm dia 610mm long
C.P brass towel ring
Providing and fixing in position C.P. Acryli shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-incharge ) fixed in with rawl plugs and C.P brass screws complete in all respect.
CP brass Acrylic Shelf size 560mmx130mm
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock long nose/ long body without flange
C.P Brass bib cock foam flow without flange
Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing and fixing in position C.P. brass Foot operated auto closing valve for Basin taps and spouts (Table mounted)with two 900x1200mm long braided hoses with 15mm nuts of approved make (to the approval of Engineer-in-charge)
Providing and fixing in position C.P. Brass Foot operated auto closing valve with pressmatic Basin taps only with plug (Table mounted)with two 900x1200mm long braided hoses with 15mm nuts of approved make (to the approval of Engineer-in-charge)
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engi
neer-in-charge ) complete in all respect.
Imported Teak Wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) 30 mm thick
12.5 mm thick cement plaster 1:4
Extra rate for First Floor
Extra rate for Second Floor
C.P.brass 15mm Concealed stop cock with flange
Providing & fixing in position 15 mm i/d C.P brass wall mixer of approved make (to the approval of Engineer-in-charge ) complete in all respect.
For 2000 ltr Water Tank
Extra rate for First Floor
Extra rate for Second Floor
C.P.brass 15mm Concealed stop cock with flange
Providing & fixing in position 15 mm i/d C.P brass wall mixer of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P brass wall mixer with Telephonic Shower
C.P. brass wall mixer without telephonic shower
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
Extra rate for First Floor
Extra rate for Second Floor
C.P.brass 15mm Concealed stop cock with flange
Providing & fixing in position 15 mm i/d C.P brass wall mixer of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
Extra rate for First Floor
Extra rate for Second Floor
C.P.brass 15mm Concealed stop cock with flange
Providing & fixing in position 15 mm i/d C.P brass wall mixer of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm)
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories:
C.P.brass 15mm Angular stop cock with Wall flange
C.P. brass towel rack 600mm long with lower hangers
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs
Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
G.I. tank nipple 25mm i/d
G.I. tank nipple 50mm i/d
For 1000 ltr Water Tank
Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.
35mm dia 900mm (36”) long
Supply and erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
35mm dia 1200mm (48”) long
ADMIN BLOCK, INDOOR MUTIPURPOSE HALL & HOSTEL BLOCK:
Foldable U Type 762mm long
PV System Solar Power Plant of 95KWp:
Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect.
25 litre capacity water heater
25 litre capacity water heater For Warden House
Providing and fixing of kitchen cabinetries, depth 550 mm at bottom & 300 mm at top, made out of both side laminated board 18 mm thick with 8 mm thick teak ply on front shutters, along with all accessories such as stainless steel baskets, masala rack (triple shelf), power coated metabox of make "Ozone/Asian Paint", telescopic channel 20" long make "Ozone", adjustable legs upto 4" height for bottom cabinetries and 8 mm thick glass shelf, 5 mm thick glass for shutters and clamps to fix glass in shutters for top cabinetries including rubbers wood Cornish on top, machine moulding for shutters, melamine polish, soft close hinges make "Ozone", Stainless Steel Handles 6" long etc. complete including carriage and labour charges for fixing at site complete in all respects.
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
Providing and fixing of Four Way burner Chullah having Tornado Brass Burner, 360 degree rotating Nozzle , Rotatary knobs , shatter proof 8 mm toughened glass top and 297L/h gas with acessories such as pipe, regulatore clip etc. consumption complete in all respect
Providing and fixing of 2 feet stainless steel chimaney having suction power 1500 CMH with 15 year warrant on moter and 5 year warranty on comprihensive complete in all respect
Brass Ball Cock with rod and Plastic Ball 32mm i/d
Providing and fixing of 90 cm auto clean stainless steel chimaney having suction power 2000 CMH with 15 year warrant on moter and 5 year warranty on comprihensive complete in all respect
Provision for taking gas connection with cylenders for warden house and mess. Note:- Payment to be made as per actual payment made to concerned agency
Providing and fixing Sauna room with Pine wood panneling and bench stainless steel heater of capacity 4.5 KW fully automatic cantrol complete in all respect
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).
Sub Head-4 Flooring and Wall Tile
Extra rate for Third Floor
Extra rate for Fourth Floor
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at mid specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in- charge.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm).
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixe
d with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..
Sub Head -5 Water Cooler & Air Conditioning
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Water Cooler Full Steel Body 150/150 ltr without Stablizer.
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Automatic Voltage Stablizer 2 KVA
Automatic Voltage Stablizer 4 KVA
Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineer-in-charge ) dispensing ot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect.(For Warden House, Admin Block and Hostel)
Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. ( For Boys Hostel)
Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Inverter Type ( having ISEER Rating 5.2 and Cooling Capacity 5280 W Minimum) witht MCB arrangement for installing OD units on terrace/Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects
Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 5 Star Inverter Type( having ISEER Rating 5 and Cooling Capacity 6000 W Minimum) with MCB arrangement for installing OD units on terrace/ Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects
Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects.
Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 25mm i/d
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Through wall 11.43 cm thick
Sub Work :- 2
Sub Head -1:- Detail of Tube well
Providing and installation of tube well, & Development of Head works
Drilling of 500mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil andtransportation of rig to the site. complete in all respect. Note: (i) Erection and dismantling of boring plant including all Arrangements for the transportation of boring Equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work. Pits for collection of water and water for drilling T/Wells be arranged by the firm / contractor at site at his own cost. (ii) In case the bore is converted into a T/Wells payement of bore shall be made upto to the bail plug plus margin (7% or main bore drilling or as actual as per field requirement whichever is less ) required for sustaining the main bore . The test bore beyond margin shall be paid at the rare of of trail bore drilling.
Drilling of 500mm dia bore with Reverse Rotatry Rig Beyond 150 m depth BGL up to 300 Mtr
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest with SS socket to connect Strainer to Strainer Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
200mm Steel Strainer (slot size 0.75mm) 6.30 mm thickness
Supplying, fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest,ISI Marked Duly Welded with suitable grade S,S welding electrode to lower the strainer into the Tubewell bore complete in all respect.
Provision for drilling 200 mm i/d test bore for taking water samples from suitable strata and chech heavy metal test as per DWSS guidelines complete in all respect
Supply & fixing of ball plug of M.S pipe complete with inverted U-hook attached to the bottom plug Complete in all respects. 200mm internal diameter (weight 33.6 kg per metre) 6.4 mm thickness
Supplying and fixing well cap having threads to fix on housing pipe complete in all respect 200mm id.
Supplying and fixing mild steel clamps of 150mm x 12mm made out of MS Flat (1.52 mtr long suitable to fit the housing pipe including the cost of Nut or bolt of suitable size complete in all respects
Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect.
Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
Supplying at site wooden box of suitable size with lid and locking arrangement for preserving strata sample received from the bore
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Supplying at quarry site of gravel of 1/6" to 1/8" sizes including pouring and packing in the annual space between the pipe assembly & the bore. The gravel should be free from dust, dirt, or the vegetable manner as per IS 4097-1967 with latest amendments (to be paid as per actual length of pipe) Note: The rates including loading & unloading charges. Carriage from quarry site will be paid extra as per actual
Extra rate for First Floor
Development and stabilizing of the Tubewell with Air Compressor required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
Extra rate for First Floor
Capacity of Air compressor 300 cfm at 250 PSI
Supplying and fixing mild steel centering guides made out of 32mm X 6mm thick M.S bar complete in all respect Note :- a) Strainer & M.S. Pipe should be properly jointed with sockets and duly welded to ensure maximum strength of joint. b) A steel strip of suitable size should be welded across the length of strainer to provide additional strength to t
and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. (10.21)
Extra rate for First Floor
he tubewell assembly.
Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball
Extra rate for First Floor
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, Urainium etc.)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Development and stabilizing of the Tubewell with Air Compressor and submersible pumping set of required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge.
Providing and fixing clay seal including pouring and packing in the annual space between the pipe assembly & the bore
Local/ Tibba Sand including pouring and packing in the annual space between the pipe assembly & the bore.
Providing sanitary seal & sterilization of well on completion of tubewell as per BIS: 2800: 2019 complete in all respect.
C.P. brass towel rack 600mm long with lower hangers
Providing and Installing Testing & Commiissioning of 1 Nos Electrically driven submersible Pump set of capable of delivering 274 LPM against a head of 66 mtr (Minimum 10.0 BHP).
Providing and Installing Electric Control panel board consisting of electrical appliances such as automatic star Delta Push Button or oil immersed starter, Main switch, VM, Ampere Meter, ELCB, shut capacitor. Single phase, preventer, indicating laps, Kit-Kat etc. complete ina all respets.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate
Providing and Fixing 65 mm G.I. Column Pipe (in 3mtr lengths each with flnages, screwed and welded on both sides) rubber gaskets, nuts and bolts
CC 1:2:4 with stone ballast
Extra Rate for Third Floor
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with t
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4.0sq.mm (84/0.3mm), 3Core
Providing & fixing Delivery main consisting D/F pipes & specials (ISI marked) inside Pump chamber inluding pressure gauge and Depth gauge etc. complete in all respects. 100mm i/d.
12.5 mm thick cement plaster 1:4
Extra rate for First Floor
Development of water works site i.e. leveling of site, making foot paths, lawns, barbed wire fencing corner pillars, angls Iron Pickets, D-Hooks M.S. gate with Masonry Pillars etc. complete as per standard drawings.
Providing & G.I barbed wire (3 ply) fencing around the Head works site in 3 rows complete in all respects. D-6 & D-8
Providing & fixing PCC Fencing Pole as per DWSS size 40mm x 40mm x 6mm 6 ft. long
For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky
Providing & fixing D-Hooks as per DWSS as per standard drawing
Construction of Brick masonry corner pillars as per W/S & Sanitation Deptt: Standard design including Cost of material such as Bricks, sand, Cement, Bajri, etc. complete respects as per W/S & Sanitation Deptt. Standard design
Providing and fixing in position steel gate complete with masonary pillars as per W/S & sanitation Deptt. Standard design.size 1.22 mtr x 1.37 mtr
Construction of CC Footpath with BM Toe wall on both side, earth filling inside as per standard drawing as DWSS standard.
Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level removal of surplus spoils from the site of works upto chain (15 m), complete in all respects.
Sub Head-2 :- Pump Chamber
Construction of Pump Chamber size 3.05 m x 3.70 m including cost of gravel pit & electric wiring, with toilet block including carriage complete in all respect.
Sub Head-3 :- Disinfection Unit
Providing, installing, testing and commissioning one no. electrically actuated diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 ltr. o f bleaching powder solution/ sodium hypo solution per hour under maximum delivery pressure up to 7kg cm2, and suction lift not less than 1.5m, as per DWSS standard specification.
Sub Head 2.2:-
Providing UGSR 100,000 ltr + 22,000 ltr including pump house
Note: The Contractor will submit Structural design & drawings for UGSR, which must have vetting from Reputed Engineering Institute, before execution.
Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.
Depth upto 1.50 m B.G.L.
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Reinforced cement concrete M-30 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth including carriage
Reinforced cement concrete M-30 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Extra rate for Smooth Surface of RCC
Extra rate for using steel produced in integrated plant from original ores complete in all respect as per the directions of Engineer-in-charge.
Elbow 90 Degree (All side socketed)
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved.
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
12.5mm thick cement plaster 1:5.
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete
Drilling of 500mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items)
Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect
Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects.
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-202 Part-I) 1999, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook
is 16mm. (for EHD and HD). R.C.C. Manhole cover 560mm i/d RCC man hole cover with frame as per ISI
Foot Rest for Manhole. Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Conglomerate floor 50mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).
is 16mm. (for EHD and HD). R.C.C. Manhole cover 560mm i/d RCC man hole cover with frame as per ISI
Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
20mm thick grey polished skirting or dado consisting of bottom layer of 16mm thick cement sand plaster 1.3 and finished 3mm thick topping of neat cement rubbed and polished including rounding of junction with floors.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating
Providing and installing in position of domestic water pressure boosting pump of approved make (To the approval of Engineer in-charge) including all pump accessaries but excluding cost of G.I pipe & specials complete in all respects.
Pressure/Booster pump of capable for delevering 156 LPM, 35 meter head (Minimum 3.0BHP) pump with CI Specials complete in all respect.
Providing & fixing 2.50mm2 core cable to Submersible Pump complete in all respect as per specifications
Providing and fixing control panel suitable for booster pump complete in all respect.
Sub Head 2.3
Estate Water Supply
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Earth work upto 1.5 m. Depth All classes of soil except rocky
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.
Foot Rest for Manhole. Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work
Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
32mm i/d Brass Ball valves
50mm i/d Brass Ball valves
Size 0.6 m. x 0.6 m.
Sub Work-3
Sub Head-3.1
Sub Head-1 Estate Sewerage
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
110 mm o/d pipes
160 mm o/d pipes
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
Cement Concrete 1:2:4 with stone ballast or shingle.using concrete mixing volumetric type
Floating coat of 1:5mm thick neat cement laid in one operation to the topping
12.5 mm thick cement plaster 1:3
Cement rendering on plaster 1mm thick
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). RCC Man hol
e cover with Frame 560mm i/d RCC man hole cover with frame as per ISI
Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. With F.P.S. bricks
Providing and Erection of cast RCC ventilating column having minimum 200mm internal diametre including excavation, basescolumns, caps, cowls or wire domes, etc. complete including carriage from the stores of the Engineer-In-Charge of works, to sites of works, loading and unloading fixing and jointing and setting the same in position complete in all respects.
9.10 m. Height
Finishing RCC vent shafts minimum 200mm internal iametre with exterior decorative cement based paints on new work two coats to give and even finish
9 m. Height R.C.C. ventilator shaft
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. For pipes 100 to 250 mm Diametre
Sub Work-4
Roof Top Rain water Harvesting
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
160mm o/d pipe of 4 Kgf. / sqcm
Construction of Haudi internal size 0.90mtr x 0.90mtr & 0.90mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x600 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge
Construction of Haudi internal size 0.45mtr x 0.45mtr & 0.45mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x450 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge
Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick C.C 1:6:12 in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 ement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar (as specified in item No. 29.49) complete and to the requirement of the Chapter-29Engineer-in-charge
Single Road Gully chamber Size 610mm x 457mm x 800mm
Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc.
Construction of Rain water recharge well 4mtr dia with working depth 3.75mtr
consisting of drilling bore 250mm dia 35mtr, supplying and lowering pvc perforated housing pipe 200 mm dia 10kgf/sqcm 50mtr sorrunded with filtermedia , galvanised stainer CI pipe Class LA 150mm i/d 4mtr duly plugged from top with bail plug, fixing MS clamp, MS socket,constructed with BB in 1:5 cement sand mortar,plastered from inside, RCC slab, filtered media in 3 Layers, 2Nos RCC Man hole cover conneted with collecting chamber size 1mtr x 1mtr x 1.20 mtr deep providing and fixing MS grating and all other relevent material required as per site complete in all respect as per drawing attached and entire satisfaction of the Engineer-in-charge
Sub Work-5
Fire Fighting Arrangements
Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity
Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity
SITC of MS Pipe Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.
Depth upto 1.50 m B.G.L.
65mm internal diameter
80mm internal diameter
Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.
100mm internal diameter
For 5000 ltr Water Tank
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut
Single Arm Bracket 1 metre Long for Steel Tubular Pole (7 to 8m)
Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
SITC of Butterfly valve Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.
Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.
100mm i/d check valve including Pump House
Providing and fixing S.S Pressure Gauge complete as required complete in all respect.
Dial diameter 100mm calibration 0-16 Kg
Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank).
Four Way inlet connection
Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects.
Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.
Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required.
Supplying, Installation, Testing and Commissioning of Non-percolating flexible CP HOSE as per IS:8423 / 1994 ISI marked 63mm dia x 15 m long complete with instantaneous type gun-metal 63 mm dia male & female coupling (IS: 903) bound and riveted to hose pipes.
Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type-2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.
Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 93
Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.
Depth upto 1.50 m B.G.L.
6 complete in all respect.
900 mm wide x 600 mm high x 500 mm deep Size (for Yard Hydrant)
600 mm wide x 600 mm high x 300 mm deep Size - (for RRL Reel)
Providing & fixing Fire Hydrants with jointing including all carriages complete. (without Fire Hydrant surface box) Size 80mm complete in all respect.
C.I Fire Hydrants 1S-908 for Yard Hydrants
C.I Fire Hydrants Stand Post Type IS-908
Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required
Providing and fixing of Pressure switch of approved make in MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all respect
Supplying and Installation control valve C/W water motor gong complete with alarm Valve, constant trim, water motor bell, 2No. Pressure Gauge. All parts UL listed. complete in all respect.
100 mm control valve
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1 as per IS
80mm i/d Sluice Valves flanged
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Providing and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9 ltr IS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved make complete in all respect.
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts.
100mm internal diameter without Excavation
12.5 mm thick cement plaster 1:4
Outside Building for Yard Hydrant Connection
100mm internal diameter with Excavation
from UGSR around building as per detail in table
Excavation by mechanical means (JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-
Overall size 16sq.mm (3Core) Armoured (Underground)
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball
EarthingwithG.I.wire/ rope inG.I.pipe partly recessed and partly on surface complete with 150 cm long 50 mm dia .G.I. earthpipe(Cutting thread sand 36 Nos. holes, 1cmdia. tomakeamesharound the GI Pipe) and with G.I. reducing socket including erectionof the same, 10.50 metre (34.44 feet) below ground levelwith20Kg. charcoal &saltmixture etc., upto 14 metre in length (including boring & refilling).
Earthingwith7/14S.W.G. (7/2.18mmdia.) G.I. rope in20mmdiaG.I. pipe with G.I. reducing socket 50mm x 20mm (upto 14Metre in length)
Jockey Pump Supply, installation, testing & Commissioning of pump in back pull out design having 50mm suction, 32mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 7.5KW/10 HP, 2900 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow: 10.8 m^3/hr(180 lpm)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_316757.xls
BOQ • 2.61 MB
SBD.pdf
Tender Documents • 28.55 MB
Download all tender documents and submit your bid