Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | ₹31.0 L Quoted ₹31.4 L | L1 | Accepted-AOC Accepted being L1 bidder |
| 2 | L2₹31.6 L+₹20,100 (0.64%)Rejected-Finance | ₹31.6 L+₹20,100 (0.64%) | L2 | Rejected-Finance Rejected being other than L1 bidder |
| 3 | L3₹33.1 L+₹1.7 L (5.44%)Rejected-Finance | ₹33.1 L+₹1.7 L (5.44%) | L3 | Rejected-Finance Rejected being other than L1 bidder |
| 4 | L4₹34.0 L+₹2.5 L (8.07%)Rejected-Finance | ₹34.0 L+₹2.5 L (8.07%) | L4 | Rejected-Finance Rejected being other than L1 bidder |
| 5 | L5₹36.8 L+₹5.4 L (17.1%)Rejected-Finance | ₹36.8 L+₹5.4 L (17.1%) | L5 | Rejected-Finance Rejected being other than L1 bidder |
| Sl No | Description | Qty | Unit | M/S ABBAS M. ENTERPRISES L2 | M/S SHABIR AHMAD SHAH AND CO L4 | M/S LATIF AHMED MIR L3 | M/s Gh Qadir and Sons L1 | M/S Bali Agencies L5 | M/s M Ashraf Brothers L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth in soft/ loose soil for laying of cables or other items and getting out complete all as specified. | 30 | Cum | 100 ₹3,000 | 85 ₹2,550 Lowest | 100 ₹3,000 | 100 ₹3,000 | 220 ₹6,600 | 230 ₹6,900 |
| 2.00 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified. | 25 | Cum | 60 ₹1,500 | 65 ₹1,625 | 50 ₹1,250 | 40 ₹1,000 Lowest | 70 ₹1,750 | 105 ₹2,625 |
| 3.00 | Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified | 5 | Cum | 90 ₹450 | 50 ₹250 | 50 ₹250 | 40 ₹200 Lowest | 190 ₹950 | 225 ₹1,125 |
| 4.00 | M&L for road/hard standing cutting upto any depth including returning filling and making good the disturbed surface by bitumen/PCC | 18 | RM | 100 ₹1,800 | 200 ₹3,600 | 60 ₹1,080 Lowest | 200 ₹3,600 | 380 ₹6,840 | 315 ₹5,670 |
| 5.00 | Transporting air compressor and other allied equipment /material to and from the site of T/well, installation of machinery and dismantling there of complete all as specified and directed. | 2 | Job | 7,000 ₹14,000 | 4,800 ₹9,600 Lowest | 5,500 ₹11,000 | 5,000 ₹10,000 | 6,000 ₹12,000 | 4,800 ₹9,600 Lowest |
| 6.00 | Providing of pea shaped gravel as per specification and gravel shrouding in annular space between well and liner assembly required during re-development | 2 | Cum | 2,500 ₹5,000 | 1,800 ₹3,600 | 1,500 ₹3,000 Lowest | 2,000 ₹4,000 | 1,900 ₹3,800 | 1,800 ₹3,600 |
| 7.00 | Re development of tubewell with air compressor of adequate capacity ( not less than 250 cfm) as per specification till the availability of sand free clear water subject to minimum of 60 hrs of operation of air compressor | 2 | Job | 1,80,000 ₹3,60,000 | 1,75,000 ₹3,50,000 | 1,45,000 ₹2,90,000 Lowest | 2,00,000 ₹4,00,000 | 2,20,000 ₹4,40,000 | 1,58,000 ₹3,16,000 |
| 8.00 | Stabilization and yield testing of tubewell by using VT pump of adequate capacity as per specification (subjected to minimum of 48 hrs of development with VT Pump) including conduction of sounding test | 2 | Job | 1,30,000 ₹2,60,000 | 1,45,000 ₹2,90,000 | 1,25,000 ₹2,50,000 | 1,30,000 ₹2,60,000 | 1,35,000 ₹2,70,000 | 1,20,000 ₹2,40,000 Lowest |
| 9.00 | S&F 20 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench including taking out old unserviceable pipe, complete all as specified and directed. | 60 | RM | 100 ₹6,000 Lowest | 220 ₹13,200 | 150 ₹9,000 | 180 ₹10,800 | 110 ₹6,600 | 130 ₹7,800 |
| 10.00 | S&F 25 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench including taking out old unserviceable pipe, complete all as specified and directed. | 60 | RM | 100 ₹6,000 Lowest | 300 ₹18,000 | 195 ₹11,700 | 150 ₹9,000 | 120 ₹7,200 | 160 ₹9,600 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 May 2026, 6:00 pmClosed
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR C/o 56 APO PIN-937208
REPAIR/MAINT OF PUMP/MOTORS, STARTERS, CHLORINATION PLANTS AND CONNECTED ITEMS AND REDEVELOPMENT BOREWELL AT VARIOUS PUMP HOUSE IN AF STN AWANTIPUR
2026_MES_763150_1
GE (AF) AWA-02/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (AF) AWANTIPUR
₹90,000
Yes
9 Sept 2026
2 May 2026
25 May 2026
2 May 2026
23 May 2026
16 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth in soft/ loose soil for laying of cables or other items and getting out complete all as specified. | 30 | Cum | - | - |
| - | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified. | 25 | Cum | - | - |
| - | Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified | 5 | Cum | - | - |
| - | M&L for road/hard standing cutting upto any depth including returning filling and making good the disturbed surface by bitumen/PCC | 18 | RM | - | - |
| - | Transporting air compressor and other allied equipment /material to and from the site of T/well, installation of machinery and dismantling there of complete all as specified and directed. | 2 | Job | - | - |
| - | Providing of pea shaped gravel as per specification and gravel shrouding in annular space between well and liner assembly required during re-development | 2 | Cum | - | - |
| - | Re development of tubewell with air compressor of adequate capacity ( not less than 250 cfm) as per specification till the availability of sand free clear water subject to minimum of 60 hrs of operation of air compressor | 2 | Job | - | - |
| - | Stabilization and yield testing of tubewell by using VT pump of adequate capacity as per specification (subjected to minimum of 48 hrs of development with VT Pump) including conduction of sounding test | 2 | Job | - | - |
| - | S&F 20 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench including taking out old unserviceable pipe, complete all as specified and directed. | 60 | RM | - | - |
| - | S&F 25 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench including taking out old unserviceable pipe, complete all as specified and directed. | 60 | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
Tender02.pdf
Tender Documents • 1.84 MB
BOQ_854819.xls
BOQ • 1.65 MB
Corrigendum.pdf
PDF • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .