Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-Finance 2 44 A 4 KALU SARAI HAUZ KHAS DELHI SOUTH WEST DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | L1 | Accepted-Finance L1 | |
| 2 | L2₹5.0 L+₹19,541 (4.09%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹4.7 L
EMD Value
₹9,500
Closing Date
3 Mar 2022, 2:00 pmClosed
ATUL BHARDWAJ
EEE/WZ
Provision for replacement of faulty tubelights, floodlight and other electrical accessories and procurement of electrical items for day to day maintenance in SDMC Primary school, Mahaveer Enclave - II/III, supply of two core Aluminium cable for unele
2022_SDMC_107336_2
EE/Electrical/WZ/2021-22/38
Open Tender
Electrical Works
Works
30 days
WEST ZONE
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹9,500
22 Mar 2022
24 Feb 2022
4 Mar 2022
24 Feb 2022
3 Mar 2022
24 Feb 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 × 4 sq. mm + 1 × 4 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
S/1/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following :(a) Total system wattage 20 watt +/- S%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
S/1/T/C of LED Tubelight lamp T-5/T-8 20 Watt rating made up of high efficient LEDs with the following specifications:(a) Total system wattage 20 watt+/- 5% (b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
Providing and fixing circular/Hexagonal cast iron M.S. Sheet box for ceiling fan Clamp of internal dia 140mm,73mm height,top lid of 1.5 mm thick MS sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/MS sheet box by means of 3.3mm dia round headed screws,one lock at the corners,clamp shall be made of 12 mm dia MS bar bent to shape as per standard drawing.
SITC of 150 W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage = 150 watt+/- 5% (b) Luminaire Efficacy>=lO0 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200xl60x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/lsolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with 55 back plate of suitable size with danger monogram property printed on the cover etc as reqd .
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Supply of 12" (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as reqd.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supply , installation, testing and commissioning of cubical type control panel board for single phase & three phase submersible pumping set of following rating complete with contactor, relay, MCB, condenser, voltmeter, ammeter, and indication lamp etc including connections etc as reqd. (a)1.5 HP (Single Phase)
Supplying and fixing of 3 mm thick phenolic laminated sheet as required
Supply of items
Supply of Modular blanking plate
Supply of 6 pin 15/16 amps modular socket outlet, ISI marked
supply of S.P. 15/16 amps, one way modular switch, ISI marked
Supply of 3 pin 5/6 amps modular socket outlet, ISI marked
Supply of S.P. 5/6 amps, one way modular switch, ISI marked
Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole
(b) Double Pole
Supply of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following :(a) Total system wattage 20 watt +/- S%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
Supply of XLPE insulated, PVC sheathed Al.conductor Un Armoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes. (a) 2 x 4 sq mm
Supply of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125A, 16KA
Shifting of SHM
Shifting of one number of 12 mtr Semi high mast system with its accessories and reinstallation, testing, commissioning the same on suitable RCC (1:2:4) shallow foundation of size 1m(L)x1m wide and 2m deep i/c excavation of earth , providing cutting, bending and placing in position, reinforcement of cold twisted bar of 12 mm dia-2100mm long (approx.)-16 nos. and reinforcement of cold twisted bar of 8 mm dia- 3700 mm (approx.)-13 nos. (with 150 mm spacing ) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit with foundation nut bolts and anchor plate as required for the high mast considering the safe soil bearing capacity at site as 10T/sqm at 2mts. depth
Supply and fixing of Hot press sheet moulded compound (SMC) fire retardant (temp. resistance up to 200 C ), IP 55 weather proof pole window door suitable for 12M semi high mast pole etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Supply of XLPE insulated, PVC sheathed Al.conductor Armoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes. (a) 2 x 10 sq mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984
VBENGINEERS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .