| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC NO 6 BAJANAI KOIL CROSS STREET CHATHIRAM PATTABIRAM CHENNAI 600 072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.5 L+₹71,815.20 (1.95%)Rejected-AOC | L2 | Rejected-AOC high bid value L1 being accept | |
| 3 | L3₹39.6 L+₹2.8 L (7.67%)Rejected-AOC 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | L3 | Rejected-AOC high bid value L1 being accept | |
| 4 | L4₹39.8 L+₹3.0 L (8.03%)Rejected-AOC PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L4 | Rejected-AOC high bid value L1 being accept | |
| 5 | L5₹41.9 L+₹5.1 L (13.9%)Rejected-AOC | L5 | Rejected-AOC high bid value L1 being accept |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
22 May 2023, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai600 009
82540 ADDITION and ALTERATION TO BUILDING NO. XXXVII-1,PROVISION OF SPLIT AC AND WALL PANELLING AT NAU AND SPECIAL REPAIR TO BLDG NO. XXXVI-2 UNDER AGE(I) NAVY CHENNAI
2023_MES_586768_2
CWE/NAVY/CHE/82540/E8 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
CHENNAI
As per NIT
9 documents required · 9 mandatory
₹500
AGE(I) NAVY CHENNAI
₹70,000
Yes
3 Aug 2023
2 May 2023
24 May 2023
2 May 2023
22 May 2023
9 May 2023
2 May 2023 - 5 May 2023
Amount
SCHEDULE 'A' PART-I [ B/R WORKS]
Taking down chowkhats with shutters (without taking off shutters from the frame) n.exc 1.5 sqm each complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4.0 sqm each complete all as specified and directed.
Demolition of Brickwork built in cement motar, stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for Brickwork with flyash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
Ditto as in item No. 5 but for half brick thick walls built in CM (1:4) complete all as specified and directed.
M & L for Providing & injecting ATT chemical at the point of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate 0.5 liters/holes by drilling 6mm dia holes at a downward angle of 45 degree at 150mm center and sealing the same complete all as specified and directed.
M & L for Providing & injecting ATT chemical at the point of contact of voids in masonry wall using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
S & F Aluminium powder coated frame for doors with one or more rebates (of approved colour), with frame o including joining cleat for fixing EPDM rubber/ neoprene gasket required with extruded built up standard sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom etc. complete all as specified and directed. Note : Thickness of powder coating not less than 50 micron.
Supply and fix for Powder Coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement complete all as specified and directed. Note : Thickness of powder coating not less than 50 micron.
S & F aluminium wire cloth 0.45mm nomonal dia of wire and 1.40mm average width of aperture and fixed with aluminium wire staples complete all as specified and directed.
S & F 5 mm thick sheet glass figured glass, pin head ,obscured or frosted, on one side type and aluminium glazing beads in square not exc 0.50 Sqm in each pane complete all as specified and directed.
M&L for Removal of plant growth by injection with chemical glyphospate solution ( 4 % conceneration ) of 20ml or till refuse by cutting or injection in stem of plants or roots at 30mm deep. The area shall then be sprayed with solution 25ml glyphosphate ( 4% concent) dulited with 1 ltr of water. All roots / plants shall be removed completely and making good with cement concrete/mortar and finished the surfaces matching to existing surfaces of wall / floor with acrylic paint all as directed by EIC. etc sectional area exc 0.10 Sqm and not exc 0.20 Sqm each complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting , any gauge and thickness in roof covering including Nainital or similar pattern roof covering, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L Steel work in tabular/hallow sections of trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.50mm thick of any colour having tensil strength of 550 Mpa, as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Taking down cement Plaster , any description, on brick walls or stone walls,etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M & L for 15mm thick Rendering in two coats of ( 10 mm thick on first coat and 5mm thick in second coat) on fair faces of brick work or concrete surfaces in CM (1:4) using with WPC @ 3% by wt of cement on second coat complete all as specified and directed. ( Note : WPC shall be measured and paid separately)
Supply only Integral water proofing compound complete all as specified.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaes in CM (1:6) and finised even and smooth (without using extra cement) complete all as specified and directed
M&L for 10 mm thick rendering in CM (1:3) on ceiling on soffits and finised even and smooth (without using extra cement) complete all as specified and directed
M & L for preparation of newly plastered / concrete surfaces and applying two coats of oil bound distemper over a coat of primer over one or more coat of birla wall care putty ccomplete all as specified and directed. (Make :- Interion grade acrylic emulsion shall be of the make : Asian paints "Premium Emulsion", Nerolac Paints "Beauty Gold Acrylic Emulsion, ICI Dulux "Super Smooth Acrylic Emulsion, Berger " Rangoli Acrylic Emulsion). Note: All work shall be carried out by manufacture/approved applicator of paint manufacturer only. After opening of financial bid (Cover 2) and prior to acceptance of work the lowest bidder shall submit MoU from the manufacture/ authorised applicator. Non submission of MoU within 21 days after opening of financial bid(Cover 2) the work shall constitute sufficient ground for retender.
M&L for complete removal of existing surfaces including washing / rubbing down with water of wall by vacuum based sanding machine and applying two coats of oil bound distemper/emulsion over coat of alkali resistant primer including chalk whiting over one or more coat of birla wall care putty using mechanical tool/auto roller and including necessary scaffoldings as reqd etc complete all as specified and directed . Note: All work shall be carried out by manufacture/approved applicator of paint manufacturer only. After opening of financial bid (Cover 2) and prior to acceptance of work the lowest bidder shall submit MoU from the manufacture/ authorised applicator. Non submission of MoU within 21 days after opening of financial bid(Cover 2) the work shall constitute sufficient ground for retender.
M&L fo Preparation of new surfaces of wall by vacuum based sanding machine and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. and over 2mm thick exterior birla wall care putty in two layers using mechanical tool/auto roller all as per manufacturer instruction and including necessary scaffoldings upto G+4 etc etc complete all as specified and directed. Note: All work shall be carried out by manufacture/approved applicator of paint manufacturer only. After opening of financial bid (Cover 2) and prior to acceptance of work the lowest bidder shall submit MoU from the manufacture/ authorised applicator. Non submission of MoU within 21 days after opening of financial bid(Cover 2) the work shall constitute sufficient ground for retender.
M&L for complete removal of existing treatment on walls including washing down, rubbing down by vacuum based sanding machine and and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. and over 2mm thick exterior birla wall care putty in two layers using mechanical tool/auto roller all as per manufacturer instruction and including necessary scaffoldings upto G+4 etc etc complete all as specified and directed. Note: All work shall be carried out by manufacture/approved applicator of paint manufacturer only. After opening of financial bid (Cover 2) and prior to acceptance of work the lowest bidder shall submit MoU from the manufacture/ authorised applicator. Non submission of MoU within 21 days after opening of financial bid(Cover 2) the work shall constitute sufficient ground for retender.
M&L for Preparation new plastered surfaces plastered and applying three coat of white wash on ceiling complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
M&L for 18-20 mm thick green Marble of any shade (table rubbed and polished) laid and jointed in flooring strips, window cills and jambs etc over and including 15mm thick screed bed/ backing coat in CM 1:4 complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding and rubbish off the premises complete all as specified and directed.
M&L for non- skid /mat finished/ heavy duty stair case tiles ceramic coloured tiles 7 to 8mm thick (square/Rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6.complete all as specified and directed
M&L glazed ceramic coloured tiles of approved shade 450x300mm x 7mm thick in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat of CM 1:4 10 mm thick etc complete all as specified and directed.
Material and Labour for 75 mm thick PCC 1:4:8 (40 mm graded stone aggregate ) type D-2 as in sub base of flooring/ paver block etccomplete all as specified and directed.
Material and Labour for 25mm thick sand filling (sand cushioning) under path for layers interlocking tiles.complete all as specified and directed.
Material and Labour for Machine pressed precast conctete interlocking glossy/ lacquer finish paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness including 2mm thick rubber mould glossy/ lacquer finish paver block of Grade M-35 and over sand cushion complete all as specified and directed. (Note- Sand will be measured and paid separately)
S & F in repair PVC pipe 110mm dia single socketed in any length with rubber joints fixed to walls with Stack clamps out of 50 mm by 5 mm flat iron and 6mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S & F in repair PVC pipe 75mm dia single socketed in any length with rubber joints fixed to walls with Stack clamps out of 50 mm by 5 mm flat iron and 6mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roofcomplete all as specified and directed.
S&F PVC (SWR) bends any radius bore of dia 110mm with access door complete all as specified and directed.
S&F PVC (SWR) bends any radius bore of dia 110mm complete all as specified and directed.
S&F PVC (SWR) bends any radius bore of dia 75mm with access door complete all as specified and directed.
S&F PVC (SWR) bends any radius bore of dia 75mm complete all as specified and directed.
S&F PVC (SWR) branch piece, single Single T) equal or unequal of 75mm with access door complete all as specified and directed.
Removal of building materials/debris from 1.5mtr to a distance of out side MD Land not exc 5 KM complete all as specified and directed.
Supply and fix for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
Supply and fix for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawingetc complete all as specified and directed.
Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided and including removal of APP Membrane for complete all as specified and as directed.
Dismantlig of Brickwork of one brick layer built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed
M&L for Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed.
M & L for Providing, cement concrete in roof 1:2:4 type B-0 (using 12.50 mm graded aggregate) thickness as specified to bring uniform slope in floors/ roof slab complete all as specified and directed.
M&L for 10 mm thick rendering in CM (1:3) on top of roof slab and finised even and smooth (without using extra cement) complete all as specified and directed
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface laid over roof surface with 100 mm over lap and including vertical surfaces upto required height and tucking into grooves and sealing complete with thermofusion, torch application over a tack coat of hot bitumen 85/25 @1.2kg/sqm over compitable primer at 0.40 ltr/sqm after fixing of APP membrane and clean the surface on top and applying two coat of Aluminium paint etc all as per instructed manufacturer instructions and work to be carried Authorized applicator complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Material and Labour for Plain cement concrete type C2 (1:3:6) using 40 mm graded stone aggregate as in foundation,filling and mass concrete in drain complete all as specified and directed.
M&L for Cutting holes in brick walls exc half brick but not exc one brick walls built in cement mortar for inserting holdfasts/ rafters /pipes etc and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required and including necessary scaffoldings upto G+2 etc complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings for inserting galvalume sheet into the e brick wall where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good to the existing surface, cutting not exc 10 cm girthcomplete all as specified and directed.
Material and Labour for MS framed structure as in main or cross beams, posts, rafters, purlins of specifed angular/tubular section, beams or channel sections with flange plates caps, bases, cleats and other connections i.e Plates (plain or chequered) Fe-410 W (Gde E-250) quality A complete all as specified and directed.
Material and Labour for preparation of new steel surfaces over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of zink primer etc complete all as specified and directed.
Supply and Fix for Pre-painted 10mm thick multiwall polycarbonate plain sheeting as required colour fixed with coach screw/machine rivets including all washers/nut bolts etc. including aluminium angle 25mm x 25mm x 2mm thick around frames of free or front edges and strip top bottom section with rubber gasket of width 50mm for jointing/fixing of sheet as required complete all as specified and directed.
Material and Labour for Ready Mix Micro concrete of 25 to 40 mm thick consistency of Renderoc S2 or Renderoc RG of FOSROC in consistency a batch of 25kg of Renderoc mixed with water n exc 3.50 Ltrs and mixed with 1 kg of polymer acrylic fibers all as per manufacturer's instructions and finished the surfaces even and smooth with 10mm thick rendering in CM 1:4 complete all as specified and directed by Engr-in-Charge including erecting necessary scaffolding (UP to G+5 Story ) Work carriedout through FOSROC applicator only Note:- The following stages (a) to (d) are included of Materrials and labour will be carried out .:-
Item No.60 conte..... (a) Taking out existing unserviceable plaster loose/unsound weaken cement concrete of any description and in any position from existing surface of RCC roof slab/beam/column/RCC facia /RCC chajja with power driver of pneumatic chisel after cleaning of concrete/plastered particles and Removing corrosion and all loose scales rust etc from the visible reinforcement and cleaning the steel reinforcement properly. (b) Applying one or more coat of NITO ZINK primer of FOSROC or equivalent ZINK primer of CHEMISTIC/WEBAC on visible reinforcement surface. Several time prior to placing, the concrete substrates should be saturated with clean water (C) After drying of water to applying bonding agent of modified styrene butadiene emulsion (SBR bonding agent i.e Nito bond SBR Latex or Nito bond EP of FOSROC) in proportion 1 (Nito bond SBR latex): 1 (water): 3 (OP cement) by volume with the brushing etc to bind New CM plaster / Polymer Modified plaster / Concrete / Screed concrete with old surface. (d) Providing fiber/MS mesh jali fixed to existing RCC roof slab/beam/column/RCC facia /RCC chajja as per directed by Engr-in- Charge
S&F for pressure grouting/ injected with cement slurry and admixed with Nitobond SBR latex in loosed RCC concrete surfaces and including drilling of holes not less then 12mm dia and filled with chemical. And after filling sealed with sealing compound etc complete all as specified and directed Note :- Supply only of Nito bond SBR latex and Dry cement measured and paid saperately .
Supply only admixed with Nitobond SBR latex complete all as specified and directed.
Supply only dry cement Cement ordinary portland complete all as specified and directed.
Dismantling of false ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F Hangers 6 mm dia G.I(upto 1200 mm length) adjusting level fixed to roof slabs by means ofceiling cleats made out of G.I) flats 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed.
S&F Anodised aluminum snap grid frame work as required grid (size of grid 605x605 mm) ceiling complete all as specified and directed.
M&L for 6mm thick Non asbestos fibre cement building boards mineral fibre ceiling tiles RH-99 fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed.
M & L for 15mm thick Rendering in two coats of on fair faces of brick work or concrete surfaces in CM (1:4) using with WPC @ 3% by wt of cement on second coat complete all as specified and directed. ( Note : WPC shall be measured and paid separately)
S & F for solid PVC door frame of size 95mm x 47mm made out of 5mm prelam colour PVC sheet reinforced with MS square tube, single side in opening as per specifications & drawings complete all as specified and directed
S & F for factory made solid PVC moulded door shutter, 28 to 30mme thick (stiles), with 2,4 or 6 raised panel designed with 4mm thick moulded PVC sheet on front face and 4mm plain colour PVC sheet on back face as per specification and drawing complete all as specified and directed
Supply and fix for 75mm size, Butt hinges, heavy weight, SS, and fixed complete all as specified and directed
Supply and fix aluminium handles cast type anodised for 100 mm complete all as specified and directed
Supply and fix aluminium handles cast type anodised for 150 mm complete all as specified and directed
S&F in repairs EWC Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but incl heavy duty seat cover complete set complete all as specified.
Supply and Fix in repair for low level flushing cystern 10 ltrs capacity body moulded from virgin quality high impact poly propoliyone and functional parts moulded from engneelicy grade ABS nylon and nylon glan complete incl brackets and 15mm bore 450mm long PVC connection all as directed.
Supply and Fix in repair for Wash basins flat back type, vitreous china of 550x400mm, including cutting for and pinning in ends of brackets or erecting stand inclusive of 32mm waste coupling and 1mtr waste pipe all as specified and as directed.
S&F PVC connections Hot and cold of 15 mm size with PTMT nuts of length 600mm all as specified and as directed.
Supply and Fix in repair for Fancy type CP stop/angular cock 15mm dia cast copper alloy, chromium plated fency type screwed down high pressure with half turn of capstan heads, screwed both end for iron pipe or for unions and fixed complete all as specified and directed .
Disconnecting existing tanks , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required and including Cleaning repairing, etc reconnecting and re-fixing in the same position. capacity of tank exc 500 ltrs and not exc 1000 ltrs complete all as specified and directed.
S & F for rotational moulded polyethylene water storage tank of 1000 ltrs capacity (cylindrical verftical with closed top) including dismantling of existing tank including all fittings i.e tank nipple, of 25mm dia Ball brass valves, high pressure, with polythene float and flynut etc hoisted and fixed in position complete all as specified and directed.
Supply and Fix in repairs for 25 mm outer dia 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and composite pressure pipes including all Crimp type internal sealing Planstic metal Composite fittings (such as elbows, tees, reducers, couplers, short pieces, connectors, etc.) and hooks (in case of concealed pipe work)/ clamps (in case of exposed pipe work) etc complete all as specified. having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified.
Supply and Fix in repair for Fancy type CP bib taps 15 mm dia ,chromium plated cast copper alloy with half turn type capstan heads, long/ short bodys screwed down screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed
Supply and Fix for in repair pillar taps, 15mm fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe of bore of pipe fixed all as specified and as directed.
Supply and Fix in repair for 125 mm dia Fancy type brass CP shower rose all as specified and as directed by Engineer-in-Charge complete all as specified and directed .
Supply and fix cabinet mirror size (350x450)mm of with approved colour complete including necessary fixing arrangements and taking down the old mirror and taken as credit complete all as specified and as directed.
Supply and Fix in repair for tubular towel rail, brass CP 20mm dia, 'D' type, 60cm long between flanges made of brass chromium plated complete all as specified and as directed.
Supply and Fix in repair for PVC health faucet (ABS) with rubit cleaning system 1.25 m long, PVC flexible tube and ABS wall hook complete all as specified and directed.
S&F Toilet paper holder of brass, chromium plated or stainless steel fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed.
S & F for Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
S & F in repairs 18309Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; grating and Union for discharge pipe. and including Urinal spreader complete all as specified and directed.
SCHEDULE 'A' PART-II [ E/M WORKS]
Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed.
Material and labour for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed.
(a) One light point controlled by one switch
(b) One fan point controlled by one switch
(c) One switch socket outlet modular type 3 pin 6 amp on independent board.
(d) One switch socket outlet modular type 3 pin 6 amp on same board.
All as per item No 93 above but 4 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board all as specified and as directed.
Material and labour for ceiling rose, surface Bakelite, 65 x 50 mm, two to three terminals all as specified and as directed.
Supply and Fix Switch modular type, single pole one way 6 Amps complete all as specified and as directed.
Supply and Fix Switch modular type, single pole one way 16 Amps complete all as specified and as directed.
Supply and Fix socket modular type 6 Amps 2/3 pin combined 2 module complete all as specified and as directed.
Supply and Fix socket modular type 6/16 Amps 2/3 pin combined 2 module complete all as specified and as directed.
Supply and Fix modular type electronic step regulator for ceiling fan 120 Watts , complete all as specified and as directed.
Supply and Fix for Modular white cover plate with frame,1 or 2 Module complete all as specified and directed.
Supply and Fix for Modular white cover plate with frame, 3 Module complete all as specified and directed.
Supply and Fix for Modular white cover plate with frame, 6 Module complete all as specified and directed.
Supply and Fix for Modular white cover plate with frame, 8 Module complete all as specified and directed.
Supply and Fix for Modular Metal flush box, 1 or 2 Module complete all as specified and directed.
Supply and Fix for Modular Metal flush box, 3 Module complete all as specified and directed.
Supply and Fix for Modular Metal flush box, 6 Module complete all as specified and directed.
Supply and Fix for Modular Metal flush box, 8 Module complete all as specified and directed.
Taking out and refixing the modular box with switches and sockets of any size and refixing it at new position including wiring for it complete all as specified and directed.
Taking down carefully sub-main wiring of any description and making good to their disturbed surfaces to match the existing all as specified and as directed by EIC.
Material and labour for sub main wiring (concealed) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 3 run of 4 sqmm & one run of PVC conduit shall be measured as single unit
M & L for single pole and neutral (SPN) sheet metal enclosure with a two pin and earth plug and socket complet with one single pole MCB 240 V, 20 amp including taking down old unserviceable item complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix wall mounted brushed nickel finish fixture wit opal glass diffuser suitable with 9W LED lamp B22 base internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size . Complete all as specified and directed. Make : Havells, Model : Cat Part No LHFOAJE1TZ11060 or equivalent in Ps.
Supply and Fix wall mounted LED batten with decorative end cap of capacity 4feet 20W or nearest higher wattage ,2500 lm ,6500 K suitable for Surface, Wall & Conduit mounting complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and lamp complete all as specified and directed internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and directed. (Make : Bajaj Cat :-BCLSB 20WH or equivalent as mentioned in PS)
Taking out and re-fixing the wall mounted LED batten with decorative end cap of capacity 4 feet 20w or nearest higher wattage, 2500 lm, 6500 K suitable for surface, wall & Conduit mounting complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and lamp complete all as specified and directed.
Supply and fix LED light fitting 2 feet,10 W or nearest higher wattage, 230v, suitable for Surface, Wall & Conduit mounting, with extruded aluminium housing, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. (Make : Bajaj Cat :-BCLSB 10WH or equivalent as mentioned in PS)
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, SPN 8 way DB with Degree of Protection IP 42 , Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar complete all as specified and as directed.
Supply and fix MCB SP 5 to 32 A , B curve including , disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB SPN 40 A , B curve including , disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Material and labour for sub main wiring (concealed) complete with two single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 2 run of 6 sqmm,1 run of 6 sqmm & one run of PVC conduit shall be measured as single unit
M & L for single pole and neutral (SPN) sheet metal enclosure with a two pin and earth plug and socket complet with one single pole MCB 240 V, 20/32 amp complete all as specified and as directed by the Engineer-in-Charge.
Supply ,install and testing split Air conditioner of 1.5 TR capacity inverter type 5 Star rating with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with inverter rotary compressor with inbuilt air ioniser and plazma filter for better indoor air quality complete ,complete all as specified and as directed. Make : VOLTAS / BLUESTAR /CARRIER/ O GENERAL/HITACHI. Note : Rate quoted is inclusive of the following:- (i) Drain pipe UPVC with insulation from indoor unit (at any floor) to ground floor level and is to be fixed with necessary clamps complete. (ii) Drilling hole on the brick wall to facilitate routing of Copper pipe, drain pipe and cable from indoor unit to outdoor unit. (iii) Sealing the hole from outside ,after installation, with white cement. (iv) Pressure testing , cooling performance check and product demonstation. (v) 4 core cable of any required length for connecting indoor and outdoor unit. (vi) Material and labour for fixing Remote stand in wall. (vii) Copper pipe, upto 3.00 Mtr each.
Supply and fixing of GI powder coated brackets , for fixing of split AC's including grouting with suitable size fastners complete all as specified and directed.
Supply and fixing Copper pipe 20mm dia 20SWG thickness with foam insulation including connecting complete all as specified and directed.
Supply and fixing Copper pipe 15mm dia 20SWG thickness with foam insulation including connecting complete all as specified and directed.
Supply and fix recessed mounting 2 ft x 2 ft LED luminaire 35W or nearest higher wattage 6500 K suitable for amtrong/ grid ceiling with super bright LED etc. Complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make: Crompton, Model : POLARIS I Cat Part No LCTLRN-36-FO-CDL or equivalent as specified make in PS as approved by GE
Supply and fixing in repairs energy saving LED street light fittings, 60 watts or nearest higher wattage, with in – built electronic driver, IP 66 class or protection with versatile pressure die-cast aluminium housing parts, pure polyster powder coated dark gray complete all as specified and directed.
Supply and fix new GI bracket made out of 25/32/40mm dia GI pipe length 1.2 mtr long bent to an angle 135 degree including two coats of aluminium paint over a coat of Zinc chromate primer along with clamps, bolts, nuts etc including removing old unserviceable GI bracket complete all as specified.
Supply and Fix sheet metal enclosures powder coated double door DB's, VTPN, 4 way, including taking down the old unserviceable DB and taking into credit, complete all as specified and as directed.
Supply and Fix MCB TP 415 volts 50/63 Amps with 10KA breaking capacity C curve including taking down the old unserviceable MCB and taking into credit complete all as specified and as directed.
Supply and fix MCCBs 25 to 100 Amps, 415V,16KA, 3 Pole complete all as specified and as directed.
GV Foundations
SIRITEL SYSTEMS PRIVATE LIMITED
Banyan Engineers and Contractors
M/S J P Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .