Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹24.3 L | L1 | Accepted-AOC Award of Contract |
| 2 | L2₹25.6 L+₹1.3 L (5.41%)Rejected-AOC R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹25.6 L+₹1.3 L (5.41%) | L2 | Rejected-AOC OK |
| 3 | L3₹26.1 L+₹1.7 L (7.17%)Rejected-AOC RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | ₹26.1 L+₹1.7 L (7.17%) | L3 | Rejected-AOC OK |
| 4 | L4₹29.3 L+₹5.0 L (20.5%)Rejected-AOC 20 JAIN BAZAR JAMMU 180003 J K | JAMMU | JAMMU | J K | 180003 | ₹29.3 L+₹5.0 L (20.5%) | L4 | Rejected-AOC OK |
| Sl No | Description | Qty | Unit | K S BUILDERS L1 | TARA ENTERPRISES L3 | slathia construction works L2 | A K JAIN AND SONS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Repair, comprehensive and preventive maintenance of DG set any make of the following capacities which include taking down diesel filter,Engine oil filter ,lubricating oil rubber hose pipe ,V belt oil pipe,fuel pipe and other burn spare parts etc and tightning of nuts bolt, washers greasing etc for proper running of DG set of capacity 62.5KVA . | 2 | Each Job | 606 ₹1,212 Lowest | 1,500 ₹3,000 | 900 ₹1,800 | 3,000 ₹6,000 |
| 2.00 | Ditto all as per item No.1 above but capacity of DG Set 125KVA | 2 | Each Job | 786 ₹1,572 Lowest | 2,000 ₹4,000 | 1,000 ₹2,000 | 4,000 ₹8,000 |
| 3.00 | Ditto all as per item No.1 above but capacity of DG Set 160KVA | 2 | Each Job | 986 ₹1,972 Lowest | 2,000 ₹4,000 | 1,000 ₹2,000 | 5,000 ₹10,000 |
| 4.00 | Ditto all as per item No.1 above but capacity of DE Pump 10HP | 1 | Each Job | 496 ₹496 Lowest | 1,500 ₹1,500 | 800 ₹800 | 3,000 ₹3,000 |
| 5.00 | Ditto all as per item No.1 above but capacity of DE Pump 50HP | 2 | Each Job | 706 ₹1,412 Lowest | 1,500 ₹3,000 | 800 ₹1,600 | 5,000 ₹10,000 |
| 6.00 | M&L for dismantling /opening of alternator of DG Set by disconnection of cable connections and flexible coupling, nuts/bolts and alternator foundation nut, bolts including opening of earth strip opening of alternator and checking out burnt out Winding of DG Sets of capacity 125KVA to 160 KVA and taken back in temporary platform all as specified and directed. | 2 | Each Job | 4,606 ₹9,212 | 5,000 ₹10,000 | 800 ₹1,600 Lowest | 5,000 ₹10,000 |
| 7.00 | All as per Sr item No. 06 above but DG Sets of capacity 62.5 KVA . | 1 | Each Job | 3,606 ₹3,606 | 5,000 ₹5,000 | 500 ₹500 Lowest | 5,000 ₹5,000 |
| 8.00 | Taking out burnt armature, winding wire and rewinding of armature with super enamelled copper winding wire of existing gauge for 62.5KVA to 160 KVA set wire DG sets. | 60 | Kg | 706 ₹42,360 | 650 ₹39,000 Lowest | 1,000 ₹60,000 | 700 ₹42,000 |
| 9.00 | Taking out burnt field coil and rewinding of field coil with super enamelled copper winding wire of existing gauge for 62.5KVA to 160 KVA sets. | 90 | Kg | 706 ₹63,540 | 650 ₹58,500 Lowest | 1,000 ₹90,000 | 700 ₹63,000 |
| 10.00 | M&L for insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature for 125 KVA to 160 KVA DG Sets. | 2 | Each Job | 1,206 ₹2,412 | 3,000 ₹6,000 | 600 ₹1,200 Lowest | 2,000 ₹4,000 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Jun 2025, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
REPAIR MAINT OF DG SETS MISC ITEMS LED SOLAR STREET LIGHT EXTERNAL LIGHTING ETC OTHER CONNECTED WORKS INCL REPAIR AND MAINT OF LIGHTNING CONDUCTOR INFRASTRUCTURE AT JINDRAH UNDER GE ARMY DHAR ROAD
2025_MES_706786_1
8071/NIT-33/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹70,000
Yes
12 Sept 2025
5 May 2025
9 Jun 2025
6 May 2025
7 Jun 2025
20 May 2025
Amount
Repair, comprehensive and preventive maintenance of DG set any make of the following capacities which include taking down diesel filter,Engine oil filter ,lubricating oil rubber hose pipe ,V belt oil pipe,fuel pipe and other burn spare parts etc and tightning of nuts bolt, washers greasing etc for proper running of DG set of capacity 62.5KVA .
Ditto all as per item No.1 above but capacity of DG Set 125KVA
Ditto all as per item No.1 above but capacity of DG Set 160KVA
Ditto all as per item No.1 above but capacity of DE Pump 10HP
Ditto all as per item No.1 above but capacity of DE Pump 50HP
M&L for dismantling /opening of alternator of DG Set by disconnection of cable connections and flexible coupling, nuts/bolts and alternator foundation nut, bolts including opening of earth strip opening of alternator and checking out burnt out Winding of DG Sets of capacity 125KVA to 160 KVA and taken back in temporary platform all as specified and directed.
All as per Sr item No. 06 above but DG Sets of capacity 62.5 KVA .
Taking out burnt armature, winding wire and rewinding of armature with super enamelled copper winding wire of existing gauge for 62.5KVA to 160 KVA set wire DG sets.
Taking out burnt field coil and rewinding of field coil with super enamelled copper winding wire of existing gauge for 62.5KVA to 160 KVA sets.
M&L for insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature for 125 KVA to 160 KVA DG Sets.
All as per Sr item No.10 above but DG Sets of capacity 62.5 KVA
M&L for insulation of field coils with Class ‘B’ insulation and varnishing of field coils and drying up to desired temperature for 125KVA to 160 KVA Alternator of DG Sets.
Re-assembling of rotor and stator after rewinding and re-fixing of Alternator with Engine by assembling flexible coupling with alternator mounting with nuts, bolts including making cable connection complete including testing and commissioning at desire load of DG Set of capacity 125KVA to 160KVA complete all as specified and directed.
All as per Sr item No. 13 above but DG Sets of capacity 62.5KVA
Dismantling of radiator and repair by welding/soldering of radiator fins and re-fixing the same after de-scaling and brazing and cleaning of radiator with caustic soda and hydrochloric acid including replacement of radiator foundation nuts, bolts (where ever required) complete all as specified and directed.
M&L for Over hauling Fuel injector pump from DG set carefully, transprotation of the same to civil work-shop for repair & complete service of FIP pump and calibration on automatic setting machine, shifting of FIP pump from civil work-shop to worksite and re-fixing the same to DG set and testing complete capacity 160KVA.
M&L for Over hauling Fuel injector pump from DG set carefully, transprotation of the same to civil work-shop for repair & complete service of FIP pump and calibration on automatic setting machine, shifting of FIP pump from civil work-shop to worksite and re-fixing the same to DG set and testing complete capacity 125KVA.
M&L for Over hauling Fuel injector pump from DG set carefully, transprotation of the same to civil work-shop for repair & complete service of FIP pump and calibration on automatic setting machine, shifting of FIP pump from civil work-shop to worksite and re-fixing the same to DG set and testing complete capacity 62.5 KVA
Dismantling / Taking down the 160 KVA DG Set (Eninge and Alternator ) assembly / parts for carrying out / replacement of following spare parts at site and re-assembling the DG Set after repair and testing complete. Spare parts replaced shall be measured and paids as Supply & fixing in replacement of under following items :-
Supply of Piston Ring.set of existing type and make.
Supply of Cylinder liner with joints rings of existing type and make.
Supplyof valve cylinder head assly of existing type and make.
Supply of valve seat insert (inlet) of existing type and make.
Supply of valve Guide Cyl head of existing type and make.
Supply of Valve collet (3-grove)lock of existing type and make.
Supply of Cylinder head gasket of existing type and make.
Supply of Sets of Jointst(Engine Gasket set complete) of existing type and make.
Supply of Crank oil seal front of existing type and make.
Supply of Crank oil seal rear of existing type and make.
Supply of Thrust washer of existing type and make.
Supply of connecting rod bearing(cell) of existing type and make.
Supply of Main general bearing(cell) of existing type and make.
Supply of Connecting rod bush of existing type and make.
Supply & fixing in replacement of Controller/ PCB with (± / - 15V,DC) out put for hall effect sensor of existing type and make complete all as directed.
Supply only V belt /Grooved complete set for the capacity of DG Sets 62.5 KVA to 160 KVA approved make for the DG set existing type complete all as directed.
Servicing of DG Set draing out used Engine oil of DG Set and cleaning sump completely with re-filling of engine oil 15 W 40 in sealed drum after taking out un-serviceable engine oil from oil sump (Note- Oil 15W40 shall be measured and paid separetely.
Supply of Kirloskar Oil of grade 15W - 40 or as specified by manufacturer for topping up or replacement of lubricating oils during different checks complete all as specified and as directed.
Supply only Lubricating oil filter suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
Supply only Fuel filter element primary suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
Supply only Fuel filter element secondary suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
Supply only Seal ring for fuel filter suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
Supply only Air Cleaner Primary Element suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
Supply only Air Cleaner Safety Element for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
Supply only coolant premixer for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
Supply & fixing in replacement of Magnetic pickup unit suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
Supply only Hose Rubber: Engine to Radiator for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
Supply only Hose Rubber: Radiator to Engine for 62.5KVA to 160 KVA DG Sets all as specified and directed.
Suppy & Fixing in replacement of battery terminal of batteries of capacity upto 12 Volt ,100/180 Ah.inculding nuts and bolts of DG set capacity 125KVA to 160KVA complete all as specified and directed.
Suppy & Fixing in replacement of Hose TC Drain for 62. 5KVA to 160 KVA DG Sets all as specified and directed.
Suppy only Clamp Hose Bend Type for 62. 5KVA to 160 KVA DG Sets all as specified and directed.
Suppy & Fixing in replacement of Seal Oil (Front) for 62.5KVA to 160 KVA DG all as specified and directed.
Supply in fixing in replacement of self starter suitable for 62.5KVA to 160 KVA DG Sets complete all as specified and directed.
Suppy & Fixing in replacement of AVR unit suitable for 62.5KVA to 160 KVA DG Sets as prescribed by the manufacturer.
Suppy & Fixing in replacement of Charging Alternator 12 V , 3R suitable for 62.5 KVA to 125 KVA DG SET and removing of unserviceable Charging Alternator 12 V complete all as specified and directed.
Suppy & Fixing in replacement of Charging Alternator 24 V , 3R suitable for 62.5 KVA to 125 KVA DG SET and removing of unserviceable Charging Alternator 24 V complete all as specified and directed.
Supply & fixing in replacement of Instrument Panel, 3R unit suitable for 62.5 KVA to 125 KVA as prescribed by the manufacturer.
Supply & fixing in replacement of Stop Solenoid 3R unit suitable for 62.5 KVA to 125 KVA as prescribed by the manufacturer. Make - kirloskar
Supply & fixing in replacement of Engine Control Panel, 3R unit suitable for 62.5 KVA to 125KVA as prescribed by the manufacturer.
Supply & fixing in replacement of Engine Control Unit EMS907, 3R unit suitable for 62.5 KVA to 125 KVA as prescribed by the manufacturer.
Supply & fixing in replacement of Start Stop card RB electronics of existing type and make.
suppl only of Fuel Pipe for filter (pre- filter to take unit). of existing type and make.
suppl only of Fuel return pipe of existing type and make complete all as directed.
suppl only 1.1 Ltr Duel Fuel filter w/o over flow valve. of existing type and make complete all as directed.
suppl only of Silencer suitable DG Set for capacity 125KVA to 160KVA of existing type and make.
suppl only Silencer suitable DG Set for capacity 62.5KVA of existing type and make.
Supply & fixing in replacement of Oil pump assly of existing type and make.
Supply & fixing in replacement of Piston assembly of existing type and make.
Supply & fixing in replacement of Harness,wiring engine of existing type and make.
Repair /Turner job of Cylinder head assly (valve set fitting,valve guide fitting,valve grinding and fitting (turner job) taking out from DG set carefully, transportation of the same to civil work-shop for repair & complete service and calibration on automatic setting machine and civil work-shop to worksite capcity of DG set 62.5KVA.
Repair /Turner job of Crank shaft taking out from DG set carefully, transportation of the same to civil work-shop for repair & complete service and calibration on automatic setting machine and civil work-shop to worksite capcity of DG set 125KVA to 160KVA.
S&F in replacement of Off load side handle change over switch 200 Amps, 4 pole, 415 volts with sheet metal enclosure complete all as directed.
S&F in replacement of Off load side handle change over switch 100 Amps, 4 pole, 415 volts with sheet metal enclosure complete all as directed.
M&L for writing SM No. /MES No. /Maker No/Make /Capacity with letter of required siize i.e hight and thickness of letter on machine /plant at site deploying 'sign writer' complete all as specified & directed.
Shifting of DG Set any capacity any size at one place to other place by removing all connections of Alternator and panel with help of skilled electrician and labour, pull up the DG Set with the help of crane and fix the DG Set at plinth of RCC with the help of crane and connections of panel and alternator and testing of DG Set at load after re-shifiting all as specified and directed by Engr-in - Charge.
Repair/Replacement of Digital / S96 Voltmeter range 0-500 Volts, AC,Ammeter range 300Amp with complete panel wiring.
M&L for rubbing the uneven as well as open surface of DG set of capacity ranging from 62.5KVA to 160 KVA with emery paper, cleaning all the grease and oil substances over the area. applying two coat of synthetic enamelled paint as per existing colour code or as directed.
S&F in replacement battery 12 volt, 180Ah complete all as specified and directed.
S&F in replacement battery 12 volt, 150Ah complete all as specified and directed.
S&F in replacement of MCCB 125 Amps 4 Pole, 16 KA, 415 V, 50 Hz adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
All as per item no. 79 above but 160 Amps,36 KA
S & F in replacement air termination single pointed aluminium rod 12 mm dia and 300 mm long fitted on exisiting lightening conductor tube 40 mm on buildings with F clamps nut bolts complete all as specified and directed.
S & F in replacement earth test point terminal block made out of gun metal or phorphorus bronze size 75 x 75 x 5 mm , drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw grouting on wall with PCC, nut bolts and washers, including making good to disturbed surface complete all as specified and directed.
S&F in replacement of Galvanised iron strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and as directed .
S & F in replacement of aluminium strip 25 x 3.15 mm with saddle and fixing screws, gutties etc on wall and roof top conductors including grouting wooden gutties complete all as specified and directed.
M&L for constructing Earth pit of internal size not less than 300x300x150mm PCC 1:3:6 type C 1 chamber, RCC cover slab of 50 mm thick 1:2:4 with suitable handle.Dismantling old unsv one.
M& L in replacement of Earthing complete with Galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal Ground Level connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers and earth strip protected by 40zmm dia GI pipe medium grade connected to main Panel point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways , GI funnel with watering pipe 20 mm dia, wire mesh, salt and charcoal, protection pipe for earth strip upto 7.50m long complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified in SSR part-II earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
Supply, Installation, testing and commissioning in repair of maximum 30W All-In-One Solar Street Light with 7 M octagonal pole with 60WP high efficiency Mono Crystalline solar PV Module, LiFePO4 Battery with Inbuilt BMS Technology, MPPT Charge Controller, Aluminum extruded body with serviceable battery compartment and Differential Dimming Provided for optimizing Battery autonomy. Powder coated aluminium extruded housing as IS 16107 Part 2/sec1 and 16103 Part 2, Cl No 7 and clause 8.1 repectively at external water supply installations with following specifcations, including taking down old UNSV fittings any type/wattage all as specified and as directed by Engr in Charge :-
(a) Fully Integrated Intelligent Designed Luminaire. (b) 100% Solar Powered with high efficiency mono crystalline solar PV. (c) High efficacy LED 150 LPW. (d) Dimensions 855mm x 380mm x 56mm ±5 mm. (e) Built-In PIR Sensor. (f) Automatically control the dimming and brightness of light to increase the backup time. (g) MPPT solar charge controller. (h) Aluminium extruded body. (j) Rust-Proof Aluminum Housing. (k) Protection IP 65. (l) Visual Angle 120°. (m) Autonomy 24 Hrs With intelligent dimming. (n) Correlated Color Temperature 5700K. (o) Color Rendering Index ≥70. (p) Operating Temperature Range : -0°C to + 50°C.q) Charge Controller Efficiency ≥94%. (r) LED Lamp Life 50000 Hours. (s) Solar Charge Controller MPPT. (t) System Wattage 30W. (u) Solar Panel 60WP (±4W).(v) Luminaire efficacy >4500 Lm/Watt. (v) Battery (Lithium Ferro Phosphate4) 12.8V 24 Ah (BIS Certified) with in build BMS technology. (w) Protections : (i) Over charge (ii) Deep discharge (iii) Over current (iv) Short circuit (v) Over voltage (vi) Low voltage & chraging indication. (x) The LED chip used shall be any one of approved company. Note:- Monkey manace to be provided incl in this quoted rate
Dismantling and taking down the existing defective street light/flood light of any type and any capacity fixed at any height complete all as directed by Engr-in-Charge.
Supply and fixing LED street light fitting 90 Watt,5700K,230 V, AC outdoor type with high pressure die cast aluminum hosing ,secondary lens delivering 120 lm/watt and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as directed.
Supply and fixing LED street light fitting 72 Watt, 5700K,230 V, AC outdoor type with high pressure die cast aluminum hosing ,secondary lens delivering 120 lm/watt and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as directed.
Supply and fixing High performance LED flood light 120 watt,5700K, 230 V AC outdoor type with pressure die cast IP-66 housing, secondary lens with 120lm/w efficacy and superior aesthetic and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as directed.
Supply and fix in replacement of water proof electric distribution box( 3 Phase, 4 Wire), wheather proof IP-65 protection suitable for outdoor use, pole mounted, factory made of size 300mm x 250mm x 150mm comprising one No. MCB SP 6 Amps, 240 volts SPN bus bar not less than 25mm x 5mm aluminium strip and fixing clamps of size 25mm x 3mm two nos including necessary nuts, bolts and locking arrangement with lock, pressure type, four Nos connection holes in each bus bar with nuts, bolts and washers made of galvanized iron and connection thimble etc. complete all as specified and directed.
Supply and fixing of Junction box made out of thermo plastic material of size 240x130x110 mm with provision of single phase cable connector incomming and out going with MCB SP 6-32 amps for security light fitting/PTL IP 65 protection totally enclosed weather proof with cable entry along with GI clamps nut bolts & washer fixed on pole including dismantling/taking out old unserviceale one all as directed.
Supply and fixing Street light/Flood light fitting electronic constant current drivers/PCB/electronic gear suitable for 70 to 120 Watt LED flood light/street light fitting as required at site or as per sample incl taking out old unserviceable all as specified and directed .
Supply and fix in replacement of security light fitting bracket made up of 25/32 mm dia medium grade pipe of length 0.9 mtr with bending in shape by hot or cold method with 2 nos 50x4 mm MS flate clamps with nut bolts and washer etc all as directed
Meterial and labour for dismantling reinceforce cement concrete pole /Iron poles/struts of any size and type including breaking of concrete cutting of mild bars of any size from below the ground level up to 60 cm depth and all items removing from site all as directed by Engr -In- Chrage (Note :Excavation earth work included in this quoted rate)Note : T&P for above item will be provided by the Contractor.No extra payment will be made for it.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been errected and tested , all as specified.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
M & L for Brick protection for LT cable with sub class "B" bricks laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10mm with width equal to length complete all as specified and directed by Engr-in-Charge
Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured
Supply and laying double wall corrugated pipe (DWC) confirming to IS 14930 Part-I of size 63 mm outer dia and 50 mm inner dia all as directed.
Ditto- all as per item 103 but of size 77 mm outer dia and 63 mm inner dia all as directed.
Taking out existing worn out/old PVC insulated cable in 4/2 core of 25 sqmm to 16 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 25 Sqmm 4 core with required aluminium cable lugs all as specified and directed.
All as per item no. 106 above but size 16 sq mm 4 core
All as per item no. 106 above but size 16 sq mm 2 core
Supply and laying or fixing or passing through pipe from junction box to street light connection, 1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 10 Sqmm 2 core (TC) nominal cross section incl taking down old one complete all as directed.
All as per item no. 109 above but size 6 sq mm 2 core
Meterial and labour for cement concrete in foundations for pole or any other work type D2 1:4:8 with 40 mm graded crushed stone aggregate all as directed.
Meterial and labour for cement concrete in foundations for pole or any other work type C2 1:3:6 with 40 mm gradedcrushed stone aggregate all as directed
Meterial and labour for cement concrete in foundations for pole coping or any other work type B1 1:2:4 with 20mm graded crushed stone aggregate all as directed
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
S&F in replacement of sheet metal enclosure box made out of 3.15 mm thick CRCA sheet with powder coated paint (CPRI approved) double door outdoor type including solid aluminium bus bar of capacity 100 Amp,TPN 8 way,415volts with locking arrangements, enclosure box to be fixed on plinth foundation 1:2:4 and 150 mm above ground level including MS angle/ channel consisting of necessary fixing arrangements for incoming & out going cables with cable glands, lugs, nut, bolts, washers and fixing arrangement , PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed.
Earthing complete with Galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal Ground Level connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers and earth lead protected by 15mm dia GI pipe medium grade connected to main distribution board/ earthing test point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways , GI funnel with watering pipe 20 mm dia, wire mesh, salt and charcoal, protection pipe for earth lead upto 7.50m long complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified in SSR part-II earth lead wire and protection pipe beyond 7.5m shall be measured and paid separately.
M&L for removing old paint from the LT panels/feeder box/pole by paint removers, cleaning by scrapping and preparing the surface and applying two coats Painting complete to LT panels/feeder box with synthetic enameled paint of existing colour over a coat of red oxide primer and writing work as written of existing ie feeder feeding location etc complete all as directed by Engr-in-Charge.
M&L in replacement cast iron LT cable route indicator of size 150mm dia round plate 2mm thick with stand of angle iron approx 75mm long duly marked with LT/MES embedd in concrete block in PCC 1:2:4 complete all as specified and directed.
Supply and fixing of Steel tubular swaged poles type 410 SP-31 (9.0 meter long) complete with cast iron base plate, finial taper plug, bolts, nuts & screws etc including making the holes on the pole (bottom and top) suitable size for drawing of wire 1.5 sqmm 3 core round flexible for connection of security light fitting from junction box to light fittings including of one primer coat, one under coat and one finishing coat of silver paint all as specified and directed.
Supply and making in replacement new LT 1100 V end termination with 25 sqmm aluminium lugs duly crimped for LT 3 ½ core armoured aluminium conductor cable after isolating supply to LT panel and disconnecting brunt/fault cable from the bunch of cables in trenches,alleries, removing cable loop, opening the cable blank and connecting back after end terminals, testing and commissioning for following sizes all as specified and as directed Note Excavation,Removal, Return filling in to be paid in deemed quoted rate.
All as per item No: 121 here in before but 16 sqmm
Taking out old handing GI strip/Aluminium (damaged by Monkey ) from roof and wall complete excluding straightening the strip and refixing in the same position with saddle fixing screws gutties etc on wall and roof op conductors including grouting wooden gutties complete all as specified and directed.
S & F GI tubing light grade 40 mm bore fixing in bricks/stone wall with 2 Nos sopporting clamp made of flat iron of size 25 x 4 mm including nut bolt and grouting bolt complete all as specified and directed for fixing lightening arrester on roof top.
S&F GI tubing medium grade 40 mm bore fixing including grouting in PCC complete all as specified and directed for fixing lightening arrester on roof top.
M&L for testing of earthing (in Half Yearly Ending June 2025 and Dec 2025 ) inside/outside Depot Area ( 1 ASD, 2ASD, ATA, E/M Installation, Quarter Guard) duly filling the respective register of earthing provided by JE E/M office. Note:- necessary tools and plants and earth tester to be provided by Contractor in deemed quoted rate.
M&L for preparing scraping the old painted surfaces of GI Pipe light grade 40 mm fixed on wall/roof for lightening conductor and applying two coat of aluminium paint on GI Pipe Medium grade 40 mm approx 3 mtr long and bracket, clamp complete and all as specified and directed.
Deduct Schedule of Credit of Rs. (-) 112591.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
slathia construction works (BID ID -3316305)
TARA ENTERPRISES (BID ID -3305136)
A K JAIN AND SONS (BID ID -3313693)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .