Loading…
Loading…
Tender Value
₹57.6 L
EMD Value
₹57,610
Closing Date
26 Jul 2026, 5:00 pm
Additional Chief Executive Officer,Z.P.Satara
Additional Chief Executive Officer,Z.P.Satara
CONSTRUCTION OF SAKAV ACCROASS NALA OVER TRIPUDI TO SH 136 MULGAON,NERALE,MORGIRI DHAVDE, GUREGHAR,PACHGANI ODR 136 AT DIKSHI VILLAGE, TAL-PATAN, DIST- SATARA.
2026_SATAR_1313599_1
South/A-2/E-Tendering/02
Open Tender
Civil Works
AT DIKSHI VILLAGE, TAL-PATAN
OPEN CONTRACTOR CLASS IV A AND ABOVE
9 documents required · 9 mandatory
₹5,900
₹57,610
2 Jul 2026
2 Jul 2026
27 Jul 2026
2 Jul 2026
26 Jul 2026
2 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means
Item / Page No : 2 / 153
Specification No : Bd.A.1
Spec. Page No : 259
Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge. | - | Cubic Metre | 1 | - |
| 2 | Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means
Item / Page No : 6 / 153
Specification No : Bd.A.2
Spec. Page No : 259
Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge. | 1 | Cubic Metre | 1 | ₹1 |
| 3 | Excavation for foundation in hard murum and boulders including shoring and strutting as necessary and disposing off excavated stuff as directed, excetra complete. (Lift up to 1.50 metre)
Item / Page No : 6 / 84
Specification No : BR.3
Spec. Page No : 102
Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge. | 1 | Cubic Metre | - | - |
| 4 | Excavation for foundation in soft rock including shoring and strutting as necessary and disposing off excavated stuff as directed, excetra complete. (Lift up to 1.50 metre)
Item / Page No : 8 / 84
Specification No : BR.3
Spec. Page No : 102
Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge. | - | Cubic Metre | - | - |
| 5 | Excavation for foundation in hard rock by controlled blasting including shoring and strutting as necessary and disposing off excavated stuff as directed, excetra complete. (Lift up to 1.50 metre)
Item / Page No : 10 / 85
Specification No : BR.3
Spec. Page No : 102-103
Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge. | - | Cubic Metre | 1 | - |
| 6 | Excavation for foundation in hard rock by chiselling and wedging or line drilling including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directed, excetra complete. (Lift up to 1.50 metre)
Item / Page No : 11 / 85
Specification No : BR.3
Spec. Page No : 102-103
Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge. | - | Cubic Metre | 1 | - |
| 7 | Dewatering on brake horse power basis by using water pump including diversion of stream, providing coffer dams, earthen bunds, excetra as may be necessary for foundation and other parts of the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump, excetra complete.(prior approval of Superintending Engineer will be necessary)
Item / Page No : 22 / 85
Specification No : BR.4
Spec. Page No : 104-105 | - | Hour | - | - |
| 8 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).
Item / Page No : 1 / 175
Specification No : Bd.E.1
Spec. Page No : 287-288
Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | 1 | - |
| 9 | Providing and laying in situ / ready mix M-25 plain cement concrete of trap / granite / quartzite / gneiss metal for cast in citu piers, abutment, returns, wings, excetra including provision of "V" shaped false joints to form suitable panels on the faces to approve design with compacting by vibrating and curing complete, including plywood / steel form work, centering (excluding dewatering by means of pump) and including bailling out water and curing finishing in cement mortar 1:3 excetra complete, as directed by engineer in charge. (With Concrete Mixer) With fine agreegates of required specifications (Natural sand / VSI sand finely washed excetra) (using ARTIFICIAL SAND). (Height up to 5 metre)
Item / Page No : 40 / 133
Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | 1 | - |
| 10 | Providing and laying in situ / ready mix controlled M-20 cement concrete of trap/ granite/ quartzite/ gneis metal for reinforced cement concrete caps over piers and abutments including necessary sacffolding plywood/ steel formwork, compacting by vibrating, finishing in centimetre 1:3 and curing etc complete ( Excluding reinforcement) With reversible drum type mixer/ concrete batch mix plant (pan mixer) . with fine agreegates of required specifications (Natural sand / VSI sand finely washed, excetra) (using ARTIFICIAL SAND).
Item / Page No : 52 / 138
Specification No : MORTH 1700, 2205, 2304
Spec. Page No : ---
Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.90 MB
BOQ_2252659.xls
BOQ • 0.35 MB
b1-2.pdf
Tender Documents • 0.88 MB
Download all tender documents and submit your bid