Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.5 LQualified Make: Swadeshi WhisPower
Model: Skyline Power Solutions, Model ELG62.5-3A-2Y-INST-NEW 13 14 RAJA GARDEN NEAR RAJOURI GARDEN METRO STATION NEW DELHI WEST DELHI DELHI 110015 UDYAM DL 11 0014726 07AAAPA2227M1Z3 B 18AAAPA2227M1Z0 G 02AAAPA2227M1ZD M 07AAAPA2227M1Z3 R MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110015 | Make: Swadeshi WhisPower
Model: Skyline Power Solutions, Model ELG62.5-3A-2Y-INST-NEW | ₹12.5 L | L1 | Qualified |
| 2 | L2₹13.8 L+₹1.3 L (10.6%)Qualified Make: Kirloskar
Model: MAKE - KOEL GREEN, MODEL - KG1-62.5WS 42 WARD NO 03 797 KHAIRAGARH ROAD CHHATTISGARH 491445 | RAJNANDGAON | CHHATTISGARH | 491445 | Make: Kirloskar
Model: MAKE - KOEL GREEN, MODEL - KG1-62.5WS | ₹13.8 L+₹1.3 L (10.6%) | L2 | Qualified |
| 3 | L3₹14.6 L+₹2.1 L (17.2%)Qualified Make: Mahindra
Model: MAHINDRA-MM4905GMC2 22 IIIRD FLOOR MAIN MARKET MOTI NAGAR DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | Make: Mahindra
Model: MAHINDRA-MM4905GMC2 | ₹14.6 L+₹2.1 L (17.2%) | L3 | Qualified |
| 4 | L4₹14.8 L+₹2.3 L (18.5%)Qualified Make: Koel Green Elmech
Model: KOEL GREEN KG1-62.5WS WITH PART NO. 318125-3005 NO 15 1402 1402 CHIRANJIV TOWER 43 NEHRU PLACE NEW DELHI 110019 NEHRU PLACE NEW DELHI UTTAR PRADESH 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: Koel Green Elmech
Model: KOEL GREEN KG1-62.5WS WITH PART NO. 318125-3005 NO 15 | ₹14.8 L+₹2.3 L (18.5%) | L4 | Qualified |
| 5 | L5₹14.9 L+₹2.4 L (19.4%)Qualified Make: KOEL GREEN
Model: KOEL Green 62.5AS KG1 | Make: KOEL GREEN
Model: KOEL Green 62.5AS KG1 | ₹14.9 L+₹2.4 L (19.4%) | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Sept 2018, 3:00 pmClosed
diesel generators- DG Sets Average Turn Over of Last 3 Years 55 Lakh (s) Experience with Gov. Required 3 Year (s) Diesel Generators- DG Sets ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 62.5 * (or higher) No of Phase - Single phase
Three Phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * BIS license No
if applicable - * Type of Engine cooling Liquid Cooled Air Cooled
Liquid Cooled Type of governer Mechanical Mechanical
Electronic 1/4 (or higher) Class of governer A2 A0
A1
A2 (or higher) Number of cylinders (nos) 4 * No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500
3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 62.5 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 92 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 2 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel AMF Manual
AMF IP Rating of Control Panel IP 54 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 (or higher) Thickness of Foam 50 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * 2/4 BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * Battery capacity (Ah) - * No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Any applicable numeric value Installation & Commissioning With Installation With Installation
Without Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 737102
OFFICE OF THE DY. INSPECTOR GENERAL (GTK)
INDO-TIBETAN BORDER POLICE FORCE
MHA/GOVT. OF INDIA
BELOW METRO POINT TADONG POST OFFICE - SAMDUR (GANGTOK) DISTT. EAST SIKKIM (SIKKIM) PIN - 2 15 3/4 737102
563613
GEM/2018/B/79962
diesel generators- DG Sets
Sikkim; East District
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Average Turn Over of Last 3 Years 55 Lakh (s) Experience with Gov. Required 3 Year (s) Diesel Generators- DG Sets ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 62.5 * (or higher) No of Phase - Single phase | - | - | - |
| Three Phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * BIS license No | - | - | - |
| if applicable - * Type of Engine cooling Liquid Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Mechanical Mechanical | - | - | - |
| Electronic 1/4 (or higher) Class of governer A2 A0 | - | - | - |
| A1 | - | - | - |
| A2 (or higher) Number of cylinders (nos) 4 * No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 62.5 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 92 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 2 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel AMF Manual | - | - | - |
| AMF IP Rating of Control Panel IP 54 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 (or higher) Thickness of Foam 50 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * 2/4 BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * Battery capacity (Ah) - * No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Any applicable numeric value Installation & Commissioning With Installation With Installation | - | - | - |
| Without Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 737102 | - | - | - |
| OFFICE OF THE DY. INSPECTOR GENERAL (GTK) | - | - | - |
| INDO-TIBETAN BORDER POLICE FORCE | - | - | - |
| MHA/GOVT. OF INDIA | - | - | - |
| BELOW METRO POINT TADONG POST OFFICE - SAMDUR (GANGTOK) DISTT. EAST SIKKIM (SIKKIM) PIN - 2 15 3/4 737102 | - | - | - |
Exempted
10 Sept 2018
6 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_563613.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .