Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.3 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹23.4 L+₹7.8 L (49.9%)Rejected-Finance | 2 | Rejected-Finance Higher | |
| 3 | 3₹26.5 L+₹10.9 L (69.6%)Rejected-Finance | 3 | Rejected-Finance Higher |
Tender Value
₹25.0 L
EMD Value
₹49,920
Closing Date
29 Jan 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GE Amritsar PIN-143001
REPAIR/REPLACEMENT OF CONVENTIONAL STREET/SECURITY LIGHTS TO LED AND CONNECTED ITEMS AT OLD AMRITSAR CANTT
2020_MES_398986_2
GE/ASR-43/2020-21
Open Tender
Civil Works
Item Rate
334 days
GE Amritsar
Class E, category bi
8 documents required · 8 mandatory
₹500
GE Amritsar
₹49,920
27 May 2021
14 Jan 2021
30 Jan 2021
14 Jan 2021
29 Jan 2021
16 Jan 2021
60 days
Amount
M&L for attending day to day complaints including checking of existing street light of any type or description, fixed in vertical position with poles/wall including disconnecting the electric connection, removing from pole/wall if required, carrying out minor repairs like, removal of deposited carbon on joints/wires, removing of defective LED driver and fixing of new LED driver etc as required at site to make the items functional and refixing the same at same location or any other location, connecting with electric feeder and testing for functioning engaging sufficient man power and tool and plant etc to ensure safety of light/pole as well as working persons complete all as specified and directed. Note: (a) The completed job should remain functional for at least 6 month, any repair if required to be done for the same job within 6 months will not be paid separately. (b) cost of supplying LED driver will be paid under respective item of the schedule 'A' (c) T&P viz tools, ladder or hydra crane any type are provided by the contractor to the electrician party. (d) Complaint slip will be delivered to the representative of contractor at 9.00 AM by JE E/M or his rep at AGE E/M yard service centre and same will be handed over back to JE E/M or his rep after completing the job/compliant at 5:00 PM same day. (e) If the complaint has not been attended withiin 48 hours, the penalty of Rs. 150/- per complaint will be recovered from contractor. .
Supply and fixing in replacement of thermoplastic polycarbonate cable junction box hinged door type of size 200x160x 98 mm for P and N incoming cable, 3 P and N outgoing cable and single P & N connection for light fitting with terminal block with cage and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets as required at site complete all as specified & directed. Make : Hensel/sintex
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth below ground level for foundation of poles/ stays/cable and getting out complete all as specified .
Returning, filling in, including spreading levelling, watering and well raming in layers not exceeding 25cm thick complete all as specified and directed by Engr-in-charge.
Removal of surplus soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed by Engr-in-Charge .
Supply and laying old size as sub class 'B' bricks, laid flat in trenches over the cable along the length of cable and bricks perpendicular to the direction of cable adjacent / abutting each other compete all as specified . and directed by Engr-in-Charge.
Material and labour for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches complete all as specified and directed and sand cover to under ground cable complete all as specified .
Supply and laying, in replacement, of LT underground cable XLPE insulated, inner PVC sheathed, galvanized steel strip armoured, overall PVC sheathed electric power cable with stranded compact aluminium conductor 1100 volts grade 16 sq mm 4 core confirming to IS:7098 (Part-I) with latest amendements, suitable for earthed system laid in duct/trench/along pole etc including making connection and taking out . Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
All as per srl item No. 8 here-in-before but for cable size of 10 sq mm 2 core.
M & L PVC insulated PVC sheathed multi stranded copper conductor wire 1.5 Sqmm single core complete for drawing through pole for making connection to street light fitting provided on poles upto junction box incl thimbles.
Supply and fixing 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection for size 2 core 6 Sqmm, all as specified and directed by Engr-in-charge.
S&F street light distribution outdoor panel with canopy single door vertical type made out of CRCA MS sheet with thickness not less than 3 mm surface with insulated material like polysofer or with epoxy powder coating surface mounting TPN 4 way,415 Volt with copper bus bar rating 200Amps for R,Y,B,N phases dust and vermin proof suitable for incorporation of MCCB and IP43-IK09 profection with and incl 100 Amps 16KA 4 Pole MCCB including angle iron support legs and foundation work for the legs (including excavation and doing PCC 1:2:4). The size of the panel should not be less than 600mmx400mmx200mm, and height of the panel should be atleast 300mm above ground level. the angle iron for support should be minimum 35 mm x 35mm x 5 mm thick.
Supply and fix of 45 W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studiness excellent corrosion resistannt and water proof fixture with efficient heat dissipation design and coating , housing should have two separate compartments for light source anf driver compartment. High efficiency LED module with SMD LED package mounted on MCPCB. Driver compartment should be separate accessible and top opening for each of maintenance. LED should be mounted on heat sink conductive aluminium with fence to dissipate the heat to ambient air, covered should be toughened glass/polycarbonate. Rated voltage 240V AC/50Hz operating voltage 140V-270V operating temperature -10 degree C to +50 degree C. Power factor >0.95 , average life 50,000 Hrs @ L70. THD < 10% with test certificate . CCT 5700K with test certificate. IK 07, CRI >70 with LED lumen efficacy of 135 Lumen per watt and system lumen should be 5400 lumens or above. Driver should be isolated electronic driver with APFC and SMPS based constant current supply with lower THD. Driver shall comply to BIS standard. Valid test report of LM 79 and LM 80 from NABL accredited laboratory need to be submitted. IP 66 protection and surge protection 10 KV built in SPD with 10 KV external also. Driver shall comply safety standart as per IS : 15885 part 2 / sec 13 . Performance requirement as per IS : 16104. Test standard as per IS;16102 (Part 1) : 2012/IEC : 62560:2011. Luminar shall comply to IS: 10322/IEC 60598 with minimum 5 Years warranty.
Supply and fix in replacement of 72W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studiness excellent corrosion resistannt and water proof fixture with efficient heat dissipation design and coating , housing should have two separate compartments for light source anf driver compartment. High efficiency LED module with SMD LED package mounted on MCPCB. Driver compartment should be separate accessible and top opening for each of maintenance. LED should be mounted on heat sink conductive aluminium with fence to dissipate the heat to ambient air, covered should be toughened glass/polycarbonate. Rated voltage 240V AC/50Hz operating voltage 140V-270V operating temperature -10 degree C to +50 degree C. Power factor >0.95 , average life 50,000 Hrs @ L70. THD < 10% with test certificate . CCT 5700K with test certificate. IK 07, CRI >70 with LED lumen efficacy of 135 Lumen per watt and system lumen should be 8400 lumens or above. Driver should be isolated electronic driver with APFC and SMPS based constant current supply with lower THD. Driver shall comply to BIS standard. Valid test report of LM 79 and LM 80 from NABL accredited laboratory need to be submitted. IP 66 protection and surge protection 10 KV built in SPD with 10 KV external also. Driver shall comply safety standart as per IS : 15885 part 2 / sec 13 . Performance requirement as per IS : 16104. Test standard as per IS;16102 (Part 1) : 2012/IEC : 62560:2011. Luminar shall comply to IS: 10322/IEC 60598 with minimum 5 Years warranty.
Supply and fix in replacement of 90W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studyness excellent corrosion resistance cable gland is used for maintaining ingressprotection epoxy powder coated grey colour finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistance fixed to the housing with SS screws. High efficacy long life LED module with the SMD LED package mounted on MCPCB with lumen efficacy of LED >140 lumen/Watt with PC lens to ensure better uniformity of light distribution, ambient temperature 35 degree celcius .and system lumen 10000 for above. Power by built in isolated electronic driver SMPS base constant current supply with lower THD, output open slash short circuit protection , Over voltage protection , Phase to phase protection , surge voltage protection 10 KVA. with IK 07 and IP 66 protection, CCT 5700K CRI more than 70 THD<10%, SPD 10 KVA for internal and external 10 KVA extra should be fixed with fitting, PF> 0.95 IP66 IK07 protection with life of 50000Hrs @ L70 operating temp -10 degree to +50 degree input supply voltage range 140/270V frequency 50/60Hz . Driver safety requirement standard: IS 15885/2/13, driver performance requirement IS 16104. Photobiological safety norms IS 16108. Certification LM 79 for luminar LM 80 for LED. And warranty should be 5 Years on site. Note : (a) For item No 13 to 15 as above, T&P required for fixing of light fitting such as bamboo ladder/telescopic ladder/hydra crane is included in the quoted rate of the respective item.
Supply only, in replacement of Universal driver suitable for LED street light of capacity 60-90 Watts complete with accessories as per existing make/size/type including single core wire 1.5sqmm aluminium/copper conductor from street light to terminal/conductor complete all as specified and directed by Engineer-in-Charge. Note : Fixing of LED driver will be paid under respective item of Schedule 'A'
Supply only, in replacement of Universal driver suitable for LED street light of capacity 120 Watts complete with accessories as per existing make/size/type including single core wire 2.5sqmm copper conductor from street light to terminal/conductor complete all as specified and directed by Engineer-in-Charge. Note : Fixing of LED driver will be paid under respective item of Schedule 'A'
Supply and fixing of street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 32/40/50 mm dia size light grade complete with clamp, nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as specified and directed. Note : (a) The cost of removing the existing light fitting for changing the bracket and re-fixing of the fitting after changing the bracket is included in the quoted rate of this item.
Supply and errecting in true vertical position steel tubuler swaged poles 9 metre long complete with MS base plate, MS Pole cap, bolts nuts & screws as specified type 410 SP 22 including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion with two coats of aluminium paint over a coat of red oxide primer, including painting of 05 Nos, bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with synthetic enamel paint (white) complete all as specified and directed. Note :- Excavation & earth work shall be measured and paid separately.
Material and labour for cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation for poles, mass concrete including necessary form work complete all as specified.
Material and labour for cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in foundation for stays and coping of poles including necessary form work complete all as specified.
Dismantling/Taking down of old broken PCC poles/shruts all as specified and as directed.
Supply and fixing in replacement of LED flood light fittings 120 Watt, pressure die cast aluminium housing with heat resistance toughened glass IP66 protection with PC lens for symmetric light distribution and toughened glass fixed on housing. Lumen efficacy of 140 lumen/Watt and system lumens 12600 or above . LM 79 and LM 80 report should be submitted to department. THD < 10 %, CRI >70, CCT 5700K, operating temperature -10 degree C to +45 degree C with integral electronic LED driver with APFC lower THD open circuit protection surge voltage protection upto 10 KV with built in SPD and other safety test as IS:15885Part-2/Sec13. IK 07. Average life 50000 Hrs @ L 70 B 50 on 12 to 16 Mtr pole complete fixing on the existing steel tubular pole 16 Mtr height inclluding making electric connection complete all as specified and directed by Engr-in-Charge . Note:- Contractor shall produce the Genuineness and warranty certificate from the manufacturer before fixing. 2. All complaints will be rectified on PRIORITY basis upto completion of contract. 3. Contractor will arrange /provide suitable ladder (Telescopic/Hydra) with technicians for repair of street/High mast lights from statrting of contract upto date of completion of the work.
M/S SIMRAN WALIA ENTERPRISES
M/S BALWINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .