Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Oct 2026, 3:00 pmDue today
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
RAVI SHEKHAR SHARMA
EE
IRRIGATION DIVISION, SIKANDARA
DEEPENDRA KUMAR RAJAK
SUPERINTENDING ENGINEER
SPECIAL REPAIR OF INSPECTION BUILDING, SIKANDRA, UNDER IRRIGATION COLONY SIKANDRA, DISTRICT-JAMUI ( FY YEAR 2026-27).
140983
01/2026-27/ID/SIKANDARA (JAMUI)
Open Tender
CIVIL
Jamui
• Earnest Money
• Time of Completion
• Registration WRD in appropriate Class III
• Work Experience of Similar nature (Bidder should have satisfactory completed atleast one similar work of value not less than 10% of estimated value of work. (Rs. in Lakhs)
• Key equipment Availability (Either owned or leased or procurement )
• Character Certificate issued by District Police of Superintendent
• Affidavit in required format (Should be after the publication date of the NIT)
• GST Certificate
• PAN Card
CIVIL
PERCENTAGE
L1
1
10 documents required · 10 mandatory
₹5,000
Processing Fee: 1180
₹80,000
REFER NIT FOR THE SAME.
12 Oct 2026
1 Oct 2026
14 Oct 2026
1 Oct 2026
12 Oct 2026
1 Oct 2026
5 Oct 2026
TECHNICAL BID (GROUP NO. 01)
Name of Work SPECIAL REPAIR OF INSPECTION BUILDING, SIKANDRA , UNDER IRRIGATION COLONY SIKANDRA, DISTRICT-JAMUI ( FY YEAR 2026-27) Cost of Work as per BOQ Rs. 4000000.00 Time of Completion 31.03.2027
Sl No. Items Requirement
Name of the contractor
Address of the contractor
1 Earnest Money As per NIT duly pledged in favour of Executive Engineer, Irriagaion Division, Sikandara (Jamui) (Pay either online or offline) (Bank Guarantee only)
Bid Security Amount - Rs. 80000.00 Bid Security Amount - Rs.
2 Time of Completion 2 Months
3 Registration WRD in appropriate Class III
4 GST Certificate
6 Work Experience of Similar nature (Bidder should have satisfactory completed atleast one similar work of value not less than 10% of estimated value of work. (Rs. in Lakhs) Minimun Rs 404000 One Civil Construction of Work
6 Key equipment Availability (Either owned or leased or procurement ) Concrete, Mixture with Lift
8 Key Personnel - Site Supervisor 1 No
Fresh Graduate in Civil or Diploma in Civil + 03 Years Experience or Retired ITI Holders
9 Character Certificate issued by District Police of Superintendent
10 Affidavit in required format (Should be after the publication date of the NIT)
Executive Engineer, Irriagaion Division, Sikandara (Jamui)
Name of Work SPECIAL REPAIR OF INSPECTION BUILDING, SIKANDRA , UNDER IRRIGATION COLONY SIKANDRA, DISTRICT-JAMUI ( FY YEAR 2026-27)
BOQ Amount ₹ 4,000,000.00
Earnest Money ₹ 80,000.00
Cost of BOQ ₹ 5,000.00
Beltron Fees ₹ 590.00
Date of Tender 10-08-26
Date of Completion 2 Months
S. NO SOR ITEM OF WORK UNIT QUANTITY RATE AMOUNT
PART A CIVIL WORKS
1 15.12.1 Dismantling doors windows and clerestory windows (steel or wood) Shutters including chowkhats, architrage, holdfasts etc. complete and Stacking within 50 metres lead: Of area 3 sqm and below. each 26.00 190.70 4958.20
2 15.3 Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material withing 50 metres lead: M3 52.96 1723.90 91305.39
3 15.7.4 Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead: In cement mortar M3 77.30 998.50 77185.05
4 15.56 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. M2 467.73 26.20 12254.52
5 5.9.5 Centring and shuttering including strutting,propping etc. and removal of form work for Lintels, beams, plinth bams, griders, bressumers andcontilevers(5.9.5) M2 123.16 446.60 55002.36
6 6.1.12.1 Brick work with bricks of class designation 100A in foundations and plinth in : Cement mortar 1:4 (1 cement: 4 coarse sand ) M3 71.67 5382.30 385739.35
7 6.3.A Extra for Brick work in superstructure above plinth level upto floor V cum M3 71.67 1001.30 71761.29
8 5.9.3 Centring and shuttering including strutting,propping etc. and removal or form work for Suspended floors, roots, landings, balconies and access platform(5.9.3) M2 236.04 519.70 122668.04
9 5.2.2 Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. with 1:1.5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) M3 52.96 6207.90 328797.93
10 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complee.
11 13.24.1 6 mm cement plaster to ceiling of mix : 1:3(1 cement: 3 coarse sand) M2 188.08 145.30 27327.66
12 13.11.2 Cement plaster in course sand 12 mm cement plaster of mix: 1:4 (1 cement: 4 coarse sand ) M2 791.74 167.40 132537.14
13 15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm M2 216.60 38.10 8252.36
14 11.41A.2.1 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. M2 182.22 1081.70 197104.67
15 11.41A.3.1 Glazed Vitrified tiles Matt/Antiskid finish of Size 600mm x 600mm M2 28.05 1054.30 29573.12
16 11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming toIS : 15622 (Thickness to be specified by the manufacture) of approvedmake in all colours, shades except burgundy , bottle green , black ofany size as approved by Engineer-in-charge in skirting , risers of stepsand dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqmincluding pointing in white cementmixed with pigment of matchingshade complete(BCD 11.36) M2 65.31 787.80 51451.22
17 13.80.A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete M3 974.36 110.90 108056.16
18 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications. Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm (bcd 13.48.1) M2 808.58 117.70 95169.48
19 9.140.1 Base Wall Paneling: Providing and fixing plain lining with necessary screws/nuts & bolts/nails, including a coat of approved primer on one face, and fixed on wooden/steel frame work using 12 mm thick commercial ply conforming to IS: 1328 BWR type. M2 87.49 863.80 75570.41
20 9.41.1 Wall Louvers: Providing and fixing plain jaffri of 35x10 mm laths placed 35 mm apart (frames to be paid separately), including fixing 50x12 mm beading complete with Second class teak wood. M2 87.49 632.35 55322.21
21 9.133.3.1 False Ceiling: Providing and fixing in position concealed G.I. section using 12.5 mm thick Gypsum board (Used as an available proxy for POP ceiling framing and board) M2 40.80 858.20 35014.56
22 9.1.2 Door Frames: Providing wood work in frames of doors... Sal wood. M3 0.36 80273.00 28657.46
23 9.20.1 Doors (Ply + Decorative): Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws M2 20.58 2519.30 51847.19
24 9.92.1 Providing and fixing chromium plated brass handles with necessary screws etc. complete: 125 mm Nos 18.00 221.40 3985.20
25 9.88 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Nos 9.00 794.30 7148.70
26 9.101.2 Door Stoppers: Providing and fixing aluminium hanging floor door stopper... Twin rubber stopper. Nos 9.00 84.40 759.60
27A 9.147D.2 UPVC Windows (Small): Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). M2 10.28 8292.80 85208.52 9471
27B 9.147D.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). M2 4.50 7953.40 35790.30 9083.3
28 13.82.2 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: New wood work (two or more coats) SQM 9.52 89.80 854.90
29 13.82.3 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: Old steel work (one or more coats) M2 66.88 58.60 3918.88
30 18.90 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.
30 A 18.9.2 20mm Nominal Outer Dia Pipe m 36.57 202.00 7387.14
30 B 18.9.3 25mm Nominal Outer Dia Pipe m 18.28 273.10 4992.27
30 C 18.9.4 32mm Nominal Outer Dia Pipe m 25.00 338.00 8450.00
30 D 18.9.5 40mm Nominal Outer Dia Pipe m 3.05 443.30 1351.18
31 17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete,including cutting and making good the walls andfloors wherever required W.C. pan with ISI marked white solid plastic seat and lid (BCD17.2.1) Nos 2.00 4339.50 8679.00
32 17.13.2 Providing and fixing white vitreous china water closet squatting pan (Indian type) :Orissa pattern W.C. pan of size 580x440 mm(BCD 17.13.2) nose 1.00 2208.10 2208.10
33 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : Nos 2.00 376.90 753.80
34 18.50 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms Nos 2.00 620.80 1241.60
35 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore Nos 3.00 462.10 1386.30
36 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Nos 3.00 1065.60 3196.80
37 7189 U-PVC pipes (working pressure 4 kg/cm2) Single socketed pipe 110 mm dia. M 58.80 151.00 8878.80
39 7199 UPVC Single equal Tee (with door) (110 x110x 110mm) Nos 10.00 106.90 1069.00
40 7215 UPVC pipe clip 110 mm bend Nos 50.00 16.30 815.00
41 10.17 Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape With hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete. Nos 10.00 193.70 1937.00
1 Nos of 200mm dia, 125m Boring along with Installation of 1.5 HP Submersible Pump
42 24.1.1.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
All types of soil: 300 mm dia m 90.00 447.70 40293.00
43 24.20 Boring /drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS : 2800 (part I), including collecting samples form different strata, preparing and submitting strata chart / bore log, including hire & running Charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-Charge, upto 90 metre depth below ground level, all type of soil. 300 mm dia (BCD 24.1.1)
24.2.1.1 All types of soil-300 mm dia m 35.00 522.40 18284.00
44 24.3.2 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150mm nominal size dia (BCD 24.3.2) m 100.00 577.90 57790.00
45 24.4.2 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia m 25.00 589.50 14737.50
46 24.15.2 Providing and fixing Ball plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (Part I) . 150 mm dia (BCD 24.15.2) NOS 1.00 244.60 244.60
47 24.8 Gravel packing in tubewell construction in accordance with IS : 4097, including providing gravel fine / medium / coarse , in required grading & sizes as per actual requirement , all complete as per direction of Engineer - in-Charges.(BCD 24.8) cum 6.32 1211.40 7655.14
48 24.12 Development of tube well in accordance with IS : 2800 (part I ) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by 'V' notch method or any approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory,i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.(BCD 24.12) HRS 8.00 795.90 6367.20
49 24.14.2 Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tube well as per IS : 2800 (part I ), including necessary bots & nuts of required size complete. 150 mm clamp(BCD 24.14.2)
50 24.13.2 Providing and fixing suitable size threated mild steel cap or spot welded plate to the top of bore well housing / Casting pipe, removable as per requirement, all complete for borewell of : 150 mm dia (BCD 24.13.2)
SEPTIC TANK CONSTRUCTION (3.15m x 2.0m x 2.4 m)
51 2.6.1 Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on. plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil (BCD 2.6.1) CUM 15.12 447.10 6760.15
52 2.28 Supplying and Filling in plinth with local sand and under floors including,watering, ramming consolidating and dressing complete. (BCD 2.28) CUM 0.47 281.80 133.15
53 11.72 Providing designation 100 A one brick flat soling joints filled with localsand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of E/l,(BCD 11.72) sqm 6.30 270.80 1706.04
54 4.1.5 Providing and laying in position cement concrete of specified gradeexluding the cost of centring and shuttering-all work upto plinth level 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) (BCD 4.1.5) CUM 0.63 1864.80 1174.82
55 5.9.3 Centring and shuttering including strutting,propping etc. and removal or form work for Suspended floors, roots, landings, balconies and access platform(5.9.3) sqm 3.98 519.70 2065.81
56 5.9.5 Centring and shuttering including strutting,propping etc. and removal of form work for Lintels, beams, plinth bams, griders, bressumers andcontilevers(5.9.5) sqm 0.70 446.60 312.62
57 5.2.2 Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. with 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)(bcd 5.2.2) cum 0.70 6207.90 4337.77
58 6.1.12/1 Brick work with bricks of class designation 100A in foundations and plinth in : Cement mortar 1 .:4 (1 cement: 4 coarse sand( BCD 6.1.12/1) cum 2.61 5382.30 14047.80
59 13.11.2 Cement plaster in course sand 12 mm cement plaster of mix: 1:4 (1 cement: 4 coarse sand ) sqm 21.88 167.40 3662.71
60 13.26 Neat cement punning (bcd 13.26) sqm 25.48 45.40 1156.79
61 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complee.
Y Shaped Coil Fencing at Boundary Wall of IB
62 10.32 Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required.
10.32.2 In gratings, frames, guard bar, ladders, railings, brackts. gates & similar works kg 383.00 106.50 40789.50
63 16.53 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) mtr 150.00 250.20 37530.00
64 Carriage of Material
1 Cement- from Local 7P MT 37.08 590.20 21881.71
2 Coarse Sand- from Kiul River cum 62.29 411.10 25609.38
3 Stone Chips- from Mirza Chowki cum 45.67 2703.00 123442.69
4 Bricks- from Sikandra Th. Nos 36.90 3050.20 112546.28
6 Local Sand cum 0.57 156.50 89.00
Add S.Fees @10% of Material Cost = ₹ 27,442.55
Labour Cess 1% = ₹ 31,705.34
Total including S.Fees & L.Cess = ₹ 3,229,681.82
Total Part A : CIVIL WORKS= ₹ 3,811,025.00
PART B ELECTRICAL WORKS
S.No Electrical SOR 2023 Item No Description of Item from SOR Unit Qty Rate including GST 18%, L.Cess 1% Amount (₹) Explanation of Item of Work Calculation Showing How Quantity Had Been Arrived Remarks
65 1.3.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required. Point 76 947 71,972.00 Complete point wiring from distribution boards to individual lighting, fan, and bell fixtures. 59 lights + 15 fans/exhausts + 2 bells = 76 Points Group 'B' applies to Inspection Bungalows/Circuit Houses.
66 1.31 Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc., as required. (for light plugs to be used in non residential buildings ) Each 22 414 9,108.00 Installation of 5A convenience sockets for mobile charging, small appliances, and general use. Room-by-room matrix total = 22 Sockets Standard modular mechanism and box.
67 1.32 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as req uired. Each 14 531 7,434.00 Installation of heavy power sockets for high-draw appliances (ACs, Geysers, Pump, Fridge). ACs(2)+Heaters(2)+Geysers(3)+Kitchen(3)+Pump(1)+Fridge(1)+Store(1)+Outdoor(1) = 14 Sockets Designed for inductive and heating loads.
68 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. Metre 95 309 29,355.00 Dedicated homerun circuit wiring running directly from the Main DB to 16A power sockets. 7 power circuits (grouped) × 15m average run = 105 Metres Prevents circuit overloading as per CPWD standards.
69 2.9.3 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, (But without MCB/RCCB/lsolator) B way ( 4 + 24 ), Double door, horizontal type Each 1 6,199.00 6,199.00 Enclosure for branch circuit distribution (adapted as localized DB). 1 Sub-Distribution unit. Double door sheet steel.
70 2.16.2 Supplying and fixing following rating,four pole, 415 volt isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 Amps Each 1 1035 1,035.00 Main incoming switch-disconnector for circuit isolation. 1 Incomer unit. Sized for residential protection.
71 2.18.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps Each 1 3,010.00 3,010.00 Earth leakage protection against fatal shocks. 1 RCCB unit. High sensitivity life safety.
72 2.12.1 Supptying and fixing following rating, 24Al4L5 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required' 6 A to 32 A, Single pole "C" curve miniature circuit breaker (MCB) Each 18 237 4,266.00 Sub-circuit protection against short circuit and thermal overload. 6 lighting + 7 power + 5 spares = 18 SP MCBs. DIN-rail mounted.
73 3.1 Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal/ coke and salt )as required. Set 1 5,033.00 5,033.00 Primary ground reference pits for equipment safety. 2 Independent Earth Pits for 3-phase safety. Standard pipe earthing set.
74 3.16 Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing etc. as required. Metre 80 53 4,240.00 Grounding conductor connecting earth pits to the main panel. Pit interconnections and runs = 80 Metres. Heavy gauge mechanical strength.
75 5.2 Supplying and fixing 2'X9 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. Each 26 492 12,792.00 Energy-efficient ambient lighting across interior rooms. Room matrix light points optimized = 26 Battens BCD SOR 2023 specification.
76 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required Each 2 2,482.00 4,964.00 High-efficiency general air circulation for common halls and verandahs. Verandah V1(2) + Hall(2) + Dining(2) = 6 Fans Includes down rod and wiring.
77 8.19 Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required Each 4 3,670.00 14,680.00 Directed wall-mounted cooling for bedrooms. Bed Room 1 (2) + Bed Room 2 (2) = 4 Wall Fans Heavy duty bracket type.
78 8.17.1 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep Each 3 2,572.00 7,716.00 Moisture and odor extraction for wet and service zones. Kitchen(1) + Toilets T1, T2, T3(3) = 4 Fans Wall opening installation.
79 5.13 Supplying and fixing post top / gate light (width 250/300 mm) made up of high grade unbreakable polycarbonate material suitable for upto 20 watt LED lamp including connections and earthing the body etc as required. ( But without lamp) Each 10 1,399.00 13,990.00 Outdoor post lanterns for gate pillars and garden/pathway bollard lighting. As per Matrix: 2 Gate Pillars + 8 Garden Bollards = 10 Nos Weatherproof outdoor grade.
80 5.14.1 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required 30 watt Each 2 2,386.00 4,772.00 Weatherproof compound security lighting mounted on exterior walls. 2 Fixtures for compound walls. High efficacy LED.
81 6.1.2 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 5 watt LED lamp Each 12 137 1,644.00 Retrofit lamps for post-top lanterns and mirror highlights. 10 lanterns + 2 mirror lights = 12 Lamps Standard B22 base.
82 5.15.4 Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required 100 watt Each 6085 0.00
83 8.22.1 Supply and erection of 6 metre height Hot-dip galvanized octagonal street Iight pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundationSingle arm, 1000 mm Each 24982 0.00
84 9.16 Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
9.16.2 For 617 metre pole (500mm X 500mm X 1400mm) Each 4398 0.00
83 5.14.2 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 45 watt Each 4398 0.00
Total Part B (Electrical Works) inlcuding GST18%, Labour Cess 1% = ₹ 202,210.00
82 PART C: Supplying, installation, testing and commissioning of 1.5 HP Submersible Pump set (Single Phase, multi-stage) suitable for 150 mm bore, including HDPE/uPVC column pipe, submersible copper cable, control starter panel, safety wire rope, and lowering accessories. Unit 1 ₹ 29,500.00 ₹ 29,500.00
PART A : CIVIL WORKS TOTAL= ₹ 3,811,025.00
PART B: ELECTRICAL WORKS TOTAL= ₹ 202,210.00
PART C: 1.5 HP Submersible Pump Set TOTAL= ₹ 29,500.00
GRAND TOTAL ESTIMATED COST FOR SPECIAL REPAIR OF IB, SIKANDRA = ₹ 4,042,700.00
Amount Limit to = ₹ 4,000,000.00
Name of Work SPECIAL REPAIR OF INSPECTION BUILDING, SIKANDRA , UNDER IRRIGATION COLONY SIKANDRA, DISTRICT-JAMUI ( FY YEAR 2026-27)
BOQ Amount ₹ 4,000,000.00
Earnest Money ₹ 80,000.00
Cost of BOQ ₹ 5,000.00
Beltron Fees ₹ 590.00
Date of Tender 10-08-26
Date of Completion 2 Months
S. NO SOR ITEM OF WORK UNIT QUANTITY RATE AMOUNT
PART A CIVIL WORKS
1 15.12.1 Dismantling doors windows and clerestory windows (steel or wood) Shutters including chowkhats, architrage, holdfasts etc. complete and Stacking within 50 metres lead: Of area 3 sqm and below. each 26.00 190.70 4958.20
2 15.3 Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material withing 50 metres lead: M3 52.96 1723.90 91305.39
3 15.7.4 Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead: In cement mortar M3 77.30 998.50 77185.05
4 15.56 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. M2 467.73 26.20 12254.52
5 5.9.5 Centring and shuttering including strutting,propping etc. and removal of form work for Lintels, beams, plinth bams, griders, bressumers andcontilevers(5.9.5) M2 123.16 446.60 55002.36
6 6.1.12.1 Brick work with bricks of class designation 100A in foundations and plinth in : Cement mortar 1:4 (1 cement: 4 coarse sand ) M3 71.67 5382.30 385739.35
7 6.3.A Extra for Brick work in superstructure above plinth level upto floor V cum M3 71.67 1001.30 71761.29
8 5.9.3 Centring and shuttering including strutting,propping etc. and removal or form work for Suspended floors, roots, landings, balconies and access platform(5.9.3) M2 236.04 519.70 122668.04
9 5.2.2 Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. with 1:1.5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) M3 52.96 6207.90 328797.93
10 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complee.
11 13.24.1 6 mm cement plaster to ceiling of mix : 1:3(1 cement: 3 coarse sand) M2 188.08 145.30 27327.66
12 13.11.2 Cement plaster in course sand 12 mm cement plaster of mix: 1:4 (1 cement: 4 coarse sand ) M2 791.74 167.40 132537.14
13 15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm M2 216.60 38.10 8252.36
14 11.41A.2.1 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. M2 182.22 1081.70 197104.67
15 11.41A.3.1 Glazed Vitrified tiles Matt/Antiskid finish of Size 600mm x 600mm M2 28.05 1054.30 29573.12
16 11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming toIS : 15622 (Thickness to be specified by the manufacture) of approvedmake in all colours, shades except burgundy , bottle green , black ofany size as approved by Engineer-in-charge in skirting , risers of stepsand dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqmincluding pointing in white cementmixed with pigment of matchingshade complete(BCD 11.36) M2 65.31 787.80 51451.22
17 13.80.A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete M3 974.36 110.90 108056.16
18 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications. Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm (bcd 13.48.1) M2 808.58 117.70 95169.48
19 9.140.1 Base Wall Paneling: Providing and fixing plain lining with necessary screws/nuts & bolts/nails, including a coat of approved primer on one face, and fixed on wooden/steel frame work using 12 mm thick commercial ply conforming to IS: 1328 BWR type. M2 87.49 863.80 75570.41
20 9.41.1 Wall Louvers: Providing and fixing plain jaffri of 35x10 mm laths placed 35 mm apart (frames to be paid separately), including fixing 50x12 mm beading complete with Second class teak wood. M2 87.49 632.35 55322.21
21 9.133.3.1 False Ceiling: Providing and fixing in position concealed G.I. section using 12.5 mm thick Gypsum board (Used as an available proxy for POP ceiling framing and board) M2 40.80 858.20 35014.56
22 9.1.2 Door Frames: Providing wood work in frames of doors... Sal wood. M3 0.36 80273.00 28657.46
23 9.20.1 Doors (Ply + Decorative): Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws M2 20.58 2519.30 51847.19
24 9.92.1 Providing and fixing chromium plated brass handles with necessary screws etc. complete: 125 mm Nos 18.00 221.40 3985.20
25 9.88 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Nos 9.00 794.30 7148.70
26 9.101.2 Door Stoppers: Providing and fixing aluminium hanging floor door stopper... Twin rubber stopper. Nos 9.00 84.40 759.60
27A 9.147D.2 UPVC Windows (Small): Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). M2 10.28 8292.80 85208.52 9471
27B 9.147D.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). M2 4.50 7953.40 35790.30 9083.3
28 13.82.2 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: New wood work (two or more coats) SQM 9.52 89.80 854.90
29 13.82.3 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: Old steel work (one or more coats) M2 66.88 58.60 3918.88
30 18.90 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.
30 A 18.9.2 20mm Nominal Outer Dia Pipe m 36.57 202.00 7387.14
30 B 18.9.3 25mm Nominal Outer Dia Pipe m 18.28 273.10 4992.27
30 C 18.9.4 32mm Nominal Outer Dia Pipe m 25.00 338.00 8450.00
30 D 18.9.5 40mm Nominal Outer Dia Pipe m 3.05 443.30 1351.18
31 17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete,including cutting and making good the walls andfloors wherever required W.C. pan with ISI marked white solid plastic seat and lid (BCD17.2.1) Nos 2.00 4339.50 8679.00
32 17.13.2 Providing and fixing white vitreous china water closet squatting pan (Indian type) :Orissa pattern W.C. pan of size 580x440 mm(BCD 17.13.2) nose 1.00 2208.10 2208.10
33 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : Nos 2.00 376.90 753.80
34 18.50 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms Nos 2.00 620.80 1241.60
35 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore Nos 3.00 462.10 1386.30
36 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Nos 3.00 1065.60 3196.80
37 7189 U-PVC pipes (working pressure 4 kg/cm2) Single socketed pipe 110 mm dia. M 58.80 151.00 8878.80
39 7199 UPVC Single equal Tee (with door) (110 x110x 110mm) Nos 10.00 106.90 1069.00
40 7215 UPVC pipe clip 110 mm bend Nos 50.00 16.30 815.00
41 10.17 Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape With hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete. Nos 10.00 193.70 1937.00
1 Nos of 200mm dia, 125m Boring along with Installation of 1.5 HP Submersible Pump
42 24.1.1.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
All types of soil: 300 mm dia m 90.00 447.70 40293.00
43 24.20 Boring /drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS : 2800 (part I), including collecting samples form different strata, preparing and submitting strata chart / bore log, including hire & running Charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-Charge, upto 90 metre depth below ground level, all type of soil. 300 mm dia (BCD 24.1.1)
24.2.1.1 All types of soil-300 mm dia m 35.00 522.40 18284.00
44 24.3.2 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150mm nominal size dia (BCD 24.3.2) m 100.00 577.90 57790.00
45 24.4.2 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia m 25.00 589.50 14737.50
46 24.15.2 Providing and fixing Ball plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (Part I) . 150 mm dia (BCD 24.15.2) NOS 1.00 244.60 244.60
47 24.8 Gravel packing in tubewell construction in accordance with IS : 4097, including providing gravel fine / medium / coarse , in required grading & sizes as per actual requirement , all complete as per direction of Engineer - in-Charges.(BCD 24.8) cum 6.32 1211.40 7655.14
48 24.12 Development of tube well in accordance with IS : 2800 (part I ) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by 'V' notch method or any approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory,i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.(BCD 24.12) HRS 8.00 795.90 6367.20
49 24.14.2 Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tube well as per IS : 2800 (part I ), including necessary bots & nuts of required size complete. 150 mm clamp(BCD 24.14.2)
50 24.13.2 Providing and fixing suitable size threated mild steel cap or spot welded plate to the top of bore well housing / Casting pipe, removable as per requirement, all complete for borewell of : 150 mm dia (BCD 24.13.2)
SEPTIC TANK CONSTRUCTION (3.15m x 2.0m x 2.4 m)
51 2.6.1 Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on. plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil (BCD 2.6.1) CUM 15.12 447.10 6760.15
52 2.28 Supplying and Filling in plinth with local sand and under floors including,watering, ramming consolidating and dressing complete. (BCD 2.28) CUM 0.47 281.80 133.15
53 11.72 Providing designation 100 A one brick flat soling joints filled with localsand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of E/l,(BCD 11.72) sqm 6.30 270.80 1706.04
54 4.1.5 Providing and laying in position cement concrete of specified gradeexluding the cost of centring and shuttering-all work upto plinth level 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) (BCD 4.1.5) CUM 0.63 1864.80 1174.82
55 5.9.3 Centring and shuttering including strutting,propping etc. and removal or form work for Suspended floors, roots, landings, balconies and access platform(5.9.3) sqm 3.98 519.70 2065.81
56 5.9.5 Centring and shuttering including strutting,propping etc. and removal of form work for Lintels, beams, plinth bams, griders, bressumers andcontilevers(5.9.5) sqm 0.70 446.60 312.62
57 5.2.2 Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. with 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)(bcd 5.2.2) cum 0.70 6207.90 4337.77
58 6.1.12/1 Brick work with bricks of class designation 100A in foundations and plinth in : Cement mortar 1 .:4 (1 cement: 4 coarse sand( BCD 6.1.12/1) cum 2.61 5382.30 14047.80
59 13.11.2 Cement plaster in course sand 12 mm cement plaster of mix: 1:4 (1 cement: 4 coarse sand ) sqm 21.88 167.40 3662.71
60 13.26 Neat cement punning (bcd 13.26) sqm 25.48 45.40 1156.79
61 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complee.
Y Shaped Coil Fencing at Boundary Wall of IB
62 10.32 Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required.
10.32.2 In gratings, frames, guard bar, ladders, railings, brackts. gates & similar works kg 383.00 106.50 40789.50
63 16.53 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) mtr 150.00 250.20 37530.00
64 Carriage of Material
1 Cement- from Local 7P MT 37.08 590.20 21881.71
2 Coarse Sand- from Kiul River cum 62.29 411.10 25609.38
3 Stone Chips- from Mirza Chowki cum 45.67 2703.00 123442.69
4 Bricks- from Sikandra Th. Nos 36.90 3050.20 112546.28
6 Local Sand cum 0.57 156.50 89.00
Add S.Fees @10% of Material Cost = ₹ 27,442.55
Labour Cess 1% = ₹ 31,705.34
Total including S.Fees & L.Cess = ₹ 3,229,681.82
Total Part A : CIVIL WORKS= ₹ 3,811,025.00
PART B ELECTRICAL WORKS
S.No Electrical SOR 2023 Item No Description of Item from SOR Unit Qty Rate including GST 18%, L.Cess 1% Amount (₹) Explanation of Item of Work Calculation Showing How Quantity Had Been Arrived Remarks
65 1.3.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required. Point 76 947 71,972.00 Complete point wiring from distribution boards to individual lighting, fan, and bell fixtures. 59 lights + 15 fans/exhausts + 2 bells = 76 Points Group 'B' applies to Inspection Bungalows/Circuit Houses.
66 1.31 Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc., as required. (for light plugs to be used in non residential buildings ) Each 22 414 9,108.00 Installation of 5A convenience sockets for mobile charging, small appliances, and general use. Room-by-room matrix total = 22 Sockets Standard modular mechanism and box.
67 1.32 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as req uired. Each 14 531 7,434.00 Installation of heavy power sockets for high-draw appliances (ACs, Geysers, Pump, Fridge). ACs(2)+Heaters(2)+Geysers(3)+Kitchen(3)+Pump(1)+Fridge(1)+Store(1)+Outdoor(1) = 14 Sockets Designed for inductive and heating loads.
68 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. Metre 95 309 29,355.00 Dedicated homerun circuit wiring running directly from the Main DB to 16A power sockets. 7 power circuits (grouped) × 15m average run = 105 Metres Prevents circuit overloading as per CPWD standards.
69 2.9.3 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, (But without MCB/RCCB/lsolator) B way ( 4 + 24 ), Double door, horizontal type Each 1 6,199.00 6,199.00 Enclosure for branch circuit distribution (adapted as localized DB). 1 Sub-Distribution unit. Double door sheet steel.
70 2.16.2 Supplying and fixing following rating,four pole, 415 volt isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 Amps Each 1 1035 1,035.00 Main incoming switch-disconnector for circuit isolation. 1 Incomer unit. Sized for residential protection.
71 2.18.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps Each 1 3,010.00 3,010.00 Earth leakage protection against fatal shocks. 1 RCCB unit. High sensitivity life safety.
72 2.12.1 Supptying and fixing following rating, 24Al4L5 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required' 6 A to 32 A, Single pole "C" curve miniature circuit breaker (MCB) Each 18 237 4,266.00 Sub-circuit protection against short circuit and thermal overload. 6 lighting + 7 power + 5 spares = 18 SP MCBs. DIN-rail mounted.
73 3.1 Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal/ coke and salt )as required. Set 1 5,033.00 5,033.00 Primary ground reference pits for equipment safety. 2 Independent Earth Pits for 3-phase safety. Standard pipe earthing set.
74 3.16 Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing etc. as required. Metre 80 53 4,240.00 Grounding conductor connecting earth pits to the main panel. Pit interconnections and runs = 80 Metres. Heavy gauge mechanical strength.
75 5.2 Supplying and fixing 2'X9 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. Each 26 492 12,792.00 Energy-efficient ambient lighting across interior rooms. Room matrix light points optimized = 26 Battens BCD SOR 2023 specification.
76 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required Each 2 2,482.00 4,964.00 High-efficiency general air circulation for common halls and verandahs. Verandah V1(2) + Hall(2) + Dining(2) = 6 Fans Includes down rod and wiring.
77 8.19 Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required Each 4 3,670.00 14,680.00 Directed wall-mounted cooling for bedrooms. Bed Room 1 (2) + Bed Room 2 (2) = 4 Wall Fans Heavy duty bracket type.
78 8.17.1 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep Each 3 2,572.00 7,716.00 Moisture and odor extraction for wet and service zones. Kitchen(1) + Toilets T1, T2, T3(3) = 4 Fans Wall opening installation.
79 5.13 Supplying and fixing post top / gate light (width 250/300 mm) made up of high grade unbreakable polycarbonate material suitable for upto 20 watt LED lamp including connections and earthing the body etc as required. ( But without lamp) Each 10 1,399.00 13,990.00 Outdoor post lanterns for gate pillars and garden/pathway bollard lighting. As per Matrix: 2 Gate Pillars + 8 Garden Bollards = 10 Nos Weatherproof outdoor grade.
80 5.14.1 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required 30 watt Each 2 2,386.00 4,772.00 Weatherproof compound security lighting mounted on exterior walls. 2 Fixtures for compound walls. High efficacy LED.
81 6.1.2 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 5 watt LED lamp Each 12 137 1,644.00 Retrofit lamps for post-top lanterns and mirror highlights. 10 lanterns + 2 mirror lights = 12 Lamps Standard B22 base.
82 5.15.4 Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required 100 watt Each 6085 0.00
83 8.22.1 Supply and erection of 6 metre height Hot-dip galvanized octagonal street Iight pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundationSingle arm, 1000 mm Each 24982 0.00
84 9.16 Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
9.16.2 For 617 metre pole (500mm X 500mm X 1400mm) Each 4398 0.00
83 5.14.2 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 45 watt Each 4398 0.00
Total Part B (Electrical Works) inlcuding GST18%, Labour Cess 1% = ₹ 202,210.00
82 PART C: Supplying, installation, testing and commissioning of 1.5 HP Submersible Pump set (Single Phase, multi-stage) suitable for 150 mm bore, including HDPE/uPVC column pipe, submersible copper cable, control starter panel, safety wire rope, and lowering accessories. Unit 1 ₹ 29,500.00 ₹ 29,500.00
PART A : CIVIL WORKS TOTAL= ₹ 3,811,025.00
PART B: ELECTRICAL WORKS TOTAL= ₹ 202,210.00
PART C: 1.5 HP Submersible Pump Set TOTAL= ₹ 29,500.00
GRAND TOTAL ESTIMATED COST FOR SPECIAL REPAIR OF IB, SIKANDRA = ₹ 4,042,700.00
Amount Limit to = ₹ 4,000,000.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-01 of 2026-27.pdf
NIT • 1.55 MB
Affidavit Format.pdf
NIT • 0.92 MB
GROUP NO. 01 TECHNICAL CHECKLIST SIKANDARA JAMUI.xls
NIT • 0.03 MB
BOQ Approved IB Sikandra Lt.2072 dt 30.09.2026.pdf
NIT • 5.12 MB
BOQ FINAL _IB SIKANDRA.xlsx
NIT • 0.03 MB
UPDATED AFFIDAVIT FORMAT.pdf
NIT • 0.50 MB
Corrigendum.pdf
NIT • 0.37 MB
BOQ FINAL _IB SIKANDRA-2.xlsx
NIT • 0.03 MB
C2 Corrigendum.pdf
Corrigendum • 0.37 MB
C1 AFFIDAVIT FORMAT.pdf
Corrigendum • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .