Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.4 CrAccepted-AOC T 3 PARMESHWARI BLDG CHATRIBARI RD GUWAHATI ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹5.4 Cr | L-1 | Accepted-AOC Awarded the work with the approval from TPC-1 |
| 2 | L-2₹5.7 Cr+₹32.1 L (5.92%)Rejected-Finance RNB ROAD KOKRAJHAR ASSAM | KOKRAJHAR | ASSAM | 783331 | ₹5.7 Cr+₹32.1 L (5.92%) | L-2 | Rejected-Finance Reject during Financial evaluation |
| 3 | L-3₹5.8 Cr+₹39.0 L (7.20%)Rejected-Finance | ₹5.8 Cr+₹39.0 L (7.20%) | L-3 | Rejected-Finance Reject during Financial evaluation |
| 4 | L-4₹5.8 Cr+₹39.5 L (7.30%)Rejected-Finance | ₹5.8 Cr+₹39.5 L (7.30%) | L-4 | Rejected-Finance Reject during Financial evaluation |
Tender Value
₹6.8 Cr
EMD Value
₹15 L
Closing Date
10 Jul 2023, 11:00 amClosed
Chief General Manager PPnD APDCL
Office of CGM PPnD APDCL 6th floor Bijulee Bhawan Paltanbazar Guwahati 781001
Construction of 33kV line from Adabari GSS to Choibari DSS under Chapar ESD along with 33kV bay at Choibari DSS under Kokrajhar EC APDCL
2023_APDCL_31325_1
CGM(PPD)/APDCL/33kV line Adabari/23-24/03
Open Tender
Electrical Works
Turn-key
180 days
Chapar ESD under Kokrajhar EC
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹15 L
Bijulee Bhawan Guwahati
8 Feb 2024
22 Jun 2023
11 Jul 2023
22 Jun 2023
10 Jul 2023
30 Jun 2023
22 Jun 2023 - 26 Jun 2023
28 Jun 2023
GI Pole SP-76 with Grouting & mufflelring of Steel Tubular Pole type SP-76 with minimum planting depth of 2.15 m(using PCC)
PSC Pole 9.75 m with Grouting & mufflelring of prestressed concrete Pole of 9.75 M with minimum planting depth of 1.8 m(using PCC)
33 KV 1C X 241 Sq MM AAAC triple extruded Covered Conductor
ACSR "WOLF" conductor
GI 33 KV V cross arm with channel size (100x50x6) mm
GI Channel cross arm (100x50x6x3200 mm)
Insulated cable tie for 33 KV 1C X 241 Sq MM AAAC Covered Conductor
33 KV Poly Tension Insulator hardware with clamps, GI Pin & nuts & bolts
33 KV Poly Tension Insulator with clamps, GI Pin & nuts & bolts
33 KV Mid Span jointing kit for 241 sqmm MVCC
Termination Kit for 33 KV 1C X 241 Sq MM AAAC Covered Conductor
IPC suitable for 241 sqmm MVCC
GI earthing Pipe 50 mm dia 3 m length 3.15 mm thickness with perforated holes of 15mm dia at 30cm interval along length of the pipe
Hot Dip GI Wire 6 SWG
GI Angle (50x50x6) mm
Pin Insulator(Polymer) 5 KN(FRP 24mm)
Disc Insulator(Polymer) 70 KN(T&C type)
H/W fitting for Disc B&S 70 KN Tension type
GI LT Angle Cross Arm(40x40x6x500 )mm
LT Pin Insulator(Porcelain)
33 KV Poly pin insulator with GI Pin & nuts & bolts for MVCC
Disc Insulator(Polymer) 90 KN(T&C type)
Hardware fittings for Disc Insulator T&C 90 KN Tension Type
Pole clamp GI flat 50x6 mm
GI Nuts and Bolts(Assorted) with GI Washer
HT Stay Set
HT Guy Insulator
Hot Dip GI Stay Wire 7/10 SWG (For HT)
Barbed wire Type A
GI Angle (40x40x5) mm
HT Danger Plate
Description of Work / Item(s)
Battery Charger 110 V suitable for charging 150AH, 110V Battery Bank, Dual mode double circuitry SCR Variac Float & Boost Charger
150AH 110V Maintenance Free Battery Bank (VRLA Battery Bank)
415 AC Distribution Board (O/G feeders 6 nos)
110 V DC Distribution Board (O/g feeders 4 nos)
AB Cable 3Cx95+1Cx70sqmm (Messenger cum neutral)
Conttrol Cable 2C x 4 sqmm
Conttrol Cable 4C x 4 sqmm
Conttrol Cable 7C x 2.5 sqmm
Conttrol Cable 10C x 2.5 sqmm
33 KV C&R Panel for feeder (with IEC 61850 compliant numerical relay & static TVM)
0.5 Class 1 Ph Outdoor CT with GI mounting structure & marshaling Box (Set comprising of three units) 600-300/1-1A, 25 kA for 3 sec
33 KV/110V,1 ph Outdoor Pt with GI mounting structure & marshaling Box (Set comprising of three units)
TPGO-DBCR with earth switch and GI mounting structure 400 Amps
33 KV VCB 1250A with GI Mounting Structure
33 KV 10 KA Lighting Arrester with Surge Monitor & GI Mounting Structure (Station Type)
Disc Insulator (Porcelain) 90kN (B&S Type)
Post Insulator (Porcelain)
GI Angle (50x50x6)mm
GI Channel Cross Arm )100x50x6x2200mm)
Chequered Sheet of 8mm thickness for covering cable trenches in sub-station control room
PG Clamp for ACSR Wolf
"T" Clamp for 33kV Bay Connections (Wolf)
ACSR "WOLF" Conductor
Construction of Assam Type control room, building (20sqm) with dyna rooling as per drawing and sepecification including internal electrification water supply & sanitary works etc. complete as per direction
Construction of RCC switchyard Cable Trenches Size (500x675)mm including trays of MS/GI for cable including supply of all materials and installation of 75 mm RCC slab for cover as per specification and drawing
RCC foundation for 33 KV CT or PT
RCC foundation for 33 KV Isolator as per standard drawing and technical specifications
RCC foundation for 33 KV LA as per standard drawing and technical specifications (per No.)
RCC fundation for VCB
Installation of earthing system with MS flats 50x10mm (for earthing mat) with GI flat riser 25x6mm (for earthing conductor) and GI pipe 50mm dia of length 3000mm for earth electrodes) including excavation of earth welding etc. as necessary
BRAHMAPUTRA RIVER VALLEY TRADING PVT. LTD.
M/S Assam Electric Store
Mega Electricals
Mega Electricals
M/S Assam Electric Store
BRAHMAPUTRA RIVER VALLEY TRADING PVT. LTD.
stage.html
html • 0.05 MB
tech_eval.pdf
PDF • 0.34 MB
boq_comp_chart.xlsx
xlsx • 0.02 MB
fin_eval.pdf
PDF • 0.48 MB
aoc.pdf
PDF • 5.29 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .