Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC | ₹3.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.2 Cr+₹1.5 L (0.47%)Rejected-AOC WARD NO 5 TENGAPARA P O P S DIST KOKRAJHAR PIN 783370 | KOKRAJHAR | ASSAM | 783370 | ₹3.2 Cr+₹1.5 L (0.47%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.2 Cr+₹2.7 L (0.84%)Rejected-AOC | ₹3.2 Cr+₹2.7 L (0.84%) | L3 | Rejected-AOC L3 |
Tender Value
₹3.2 Cr
EMD Value
₹6.4 L
Closing Date
24 Feb 2020, 2:30 pmClosed
Sri J.M. Basumatary
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Upgradation of existing Degree College to Model Degree College under RUSA-2.0 at Goreswar College, District Baksa (BTAD), Assam.
2020_BTC_16273_1
74/NIT/RUSA/BTC/2019-20/9
Open Tender
Civil Works - Building
Item Rate
730 days
Goreswar College, Goreswar
Refer to SBD
6 documents required · 6 mandatory
₹9,600
Principal Secretary, BTC, Kokrajhar
₹6.4 L
Yes
28 May 2020
5 Feb 2020
24 Feb 2020
5 Feb 2020
24 Feb 2020
5 Feb 2020
5 Feb 2020 - 24 Feb 2020
Amount
New Construction work for upgradation of ten colleges to Model Degree Colleges in Assam under RUSA. CIVIL WORKS 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m below the existing ground level. In ordinari soils
4.1.1 Providing soling in foundation and under floor with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete. a) Brick flat soling
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) From Primary Producer TATA/SAIL/Esser Steel/Jindal steel Shyam steel/RINIL TMT Corrosion resistant steel (CRS) reinforcement bar
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg, drain works, retaining wall & boundary wall etc.
3.1.1 Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footing, bases of columns, pile cap, raft and mass concrete work etc. Using 38mm thick plank
3.1.1 Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.2 Sides of tie beam, plinth beams, grade beams etc. at or below plinth level. Using 38mm thick plank.
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns pillars, posts & strut Square Rectungular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and soffits of beams, beam haunchings, cantilever girders bressumers, lintels and horizontal ties. For depth not exceeding 1.0m
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc, upto 200mm in thickness.
Staircase with sloping or stepped soffits including risers and straingers but excluding landing.
2.2.1 Providing and laying plain/reinforced cement concrete work , cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using mixture machine In substructre up to plinth level. Foundation, footing, columns with base tie and plinth beam, grade beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. Without using admixture. plasticizer M20 or Prop 1:1.5:3
2.2.1 Providing and laying plain/reinforced cement concrete work , cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using mixture machine In substructre up to plinth level. 1st floor level. Column, pillars, post, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band beam girder, bressumer, cantilever, staircase including preparing the top surface and finishing of noising. M20 or prop 1:1.5:3
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure up to plinth level including dewatering if necessary In proportion 1:4
4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level ( protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) 112mm thick brick wall In cement moratar 1:4
1.3 Earth/Sand filling in plinth in layers not more than 1.50mm thick including necessary carriage, watering ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With river sand or silt (Predominantly non plastic) by truck carriage including loading and unloading.
2.1.2 Plain cement concrete floor base in prop. 1:3:6 laid in alternate bays as specified with course agg. Of size 13mm to 32mm including dewatering if necessary, and curing etc. complete 50mm thick
2.3 Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc.complete as directed.
65mm thick cement concrete floor consisting of 50mm under layer of cement concrete in prop 1:3:6(1cement :3 coarse sand :6 coarse aggregate of 25mm and down) and 15mm thick wearing layer in cement concrete in prop. 1:1:2(1cement :1coarse sand :2coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish(using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. On fair side In cement mortar 1:4
6.2.3 20mm thick cement wall plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. On rough side (backing coat 15mm and finishing coat 5mm thick) In cement mortar 1:4
10mm thick cement plaster in single coat in fair side of brick/concrete walls for inetrior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
Cement plaster skirting with cement mortar in prop 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20 X 20 X 1.25mm thick. Frame to be filled up with 1:4:8 P.C.C after fitting the frame with brick/concrete works etc. complete as directed by the department for all levels. (P.C.C to be measured and paid for separately) 1.60mm thick sheet of size 105mm X 60mm (Single rebate)
9.12.1 Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm X 75mm X 3.5mm) 6 nos with necessary wood screws. Decorative type face panel and block board core 40mm thick
Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars, joints mitred and welded (manufactured to relevent IS specifications) and providing and fixing handles, angle cleat rubber gasket, roller, bolting device, locking arrangements, screws etc. as required complete as specified and directed for all levels. 2. Track sliding window- 5mm clear glass
10.2 Providing, fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with roundheaded bolts and nuts or screws. Plain grill Fixed to Brickwork P.C.C/R.C.C
13.3.4 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) Thickness = 1.5 mm thick
13.2.2 m Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give and even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar droppings and other foreign matter and preparing surface even and sand papered smooth. Priming coat with distemper primer.
Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give and even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar droppings and other foreign matter and preparing surface even and sand papered smooth. Top coat
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly clearing oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac paint) to give an even shade including clearing the surfaces of dirt, dust and other foreign matter. Surfaces over 100mm in width or girth- General purpose (Asian paint/Berger paint/ICI paint/ J& N paint)
13.9.2 Finishing old/new wall with waterproofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats).
15.2.1 Supplying, fitting , fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & stain finished) Sliding door bolts 300mm X 16mm
15.2.1 Supplying, fitting , fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & stain finished) Tower bolts- 250mm X 12mm
15.2.1 Supplying, fitting , fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & stain finished) Door handles- 150mm
18.3.2 Prviding welding, fitting, fixing, hoisting and fixing of roof trusses of TATA make with purlin, bttom runner etc. fabricated out of a combination of two or all of the following sections: (i) Square Hollow sections (ii) Rectangular Hollow section od specification RHS/SHS Grade YST 310 conforming to relevent I.S. code 4923:1997 and (iii) M.S. black-tubes of Grade YST 210 conforming to relevent I.S. code 1239 as per approved design and drawing including M.S. cleat plate, bolts and nuts which ever required, including that required for fixing the ceiling and one coat of red oxide Zinc Chromate primer to all steel surface etc. complete as directed as per specifications. Using TATA make RHS/SHS of Grade 310 conforming to relevent I.S. code 4923:1997
8.1.33 Providing pre painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/Dyna roof/ Durakolor/Wonder Roof or equivalent as directed by the Department 0.60 mm thick
8.1.36 Providing Pre Painting Galvalume Sheet (PPGL) accessories (Ridges/Valley/ Gutter/Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue Scope/Dyna roof/ Durakolor/Wonder Roof or equivalent as directed by the department. 0.60mm thick.
Providing wood work in frame of ceiling partitions etc. swan, wrought, framed hoisted and fixed in position with spikes, nails, M.S flat, angle/cleats with bolt and nuts complete including kiricide oiling two coats to unexposed surfaces of the timber (M.S. flats, angle cleats, and bolt and nuts required for flat, angle cleatswherever necessary shall be measured and paid separately) With sall wood
Providing, fitting and fixing hard board sheet ceilling with approved quality with necessary nails, wood screws including 1st class local wood 50mm X 12mm (hollock/bonsum/sundi) beading including paining two coats to timber beads complete as directed (ceilling joist to be measured and paid separately) 4.5mm thick
5.1.1 Cement concreate works in topping 1:1:2 (1 cement: 1sand: 2 graded aggregates on R.C.C floor, treads and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg of cement per sq.m of floor to be laid in panels including curing complete as directed. (b) 20mm thick
Providing polished vetrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3(1cement:3coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). Of size 300mm X 450mm cement above
19.2 Proving plinth protection with brick flat laid in cement martar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
19.4 Providing drain with cement concreat (1:3:6) 10cm thick sides 100mm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300mm wide and average 250mm deep with bed slope 1 in 150 with depth of 100mm.
26.1.3 Pre constraction anti- termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper bsorption by the filled up earth (supplying of necessary tools and accessories bt the contractor) as per the direction of the department complete. With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution.
SANITARY & WATER SUPPLY WORKS: 1.37.1 Supplying fitting and fixing P.V.C pipes of 6 kg/cm2 (Supreme/Prince) and other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. G.L as directed and specified In exposed surfaces or in trenches- 110mm dia
1.37.1 Supplying fitting and fixing P.V.C pipes of 6 kg/cm2 (Supreme/Prince) and other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. G.L as directed and specified In exposed surfaces or in trenches- 75 mm dia
Supplying fitting and fixing G.I. pipes of following sizes, with all necessary 'R' brand or similar approved G.I. fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting. H.W. clamps. etc. complete at all levels including below G.L. as directed and specified. Exposed on walls -40mm dia (Medium)- using Tata make
Supplying fitting and fixing G.I. pipes of following sizes, with all necessary 'R' brand or similar approved G.I. fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting. H.W. clamps. etc. complete at all levels including below G.L. as directed and specified. Exposed on walls - 25mm dia (Medium)- using Tata make
Supplying fitting and fixing G.I. pipes of following sizes, with all necessary 'R' brand or similar approved G.I. fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting. H.W. clamps. etc. complete at all levels including below G.L. as directed and specified. Exposed on walls - 20mm dia (Medium)- using Tata make
1.13 Providing vitreous China wash basin with CI/ MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) Parryware Make- White
1.2 Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets, 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) White- Universal Closet S Trap (Cat No. C0271) (Anglo Indian) (Inclusive of seat cover)
Supplying, fitting and fixing PVC flushing cistern with all internal fittings with C.I. brackets including fitting and fixing standard size CP flush pipe, union clamps etc. complete as directed and specified (Pipes will be measured separately) Parryware make- white- Economy Single Flush (Cat. No. C8090/C8055)
1.2 Providing fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions etc. complete including painting of sittings and brackets, cutting and making good the walls & floors wherever required. Parryware make- White (Cat. No. C0503)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. Parryware make- white- new Magnum (Cat. No. C0575)
3.2.1 Supplying, fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I & C.P pipes will be measured separately) Jaquare make - Continental/Clanon - Standard
3.5.1 Supplying, fitting and fixing C.P. pillar cock 15mm dia of approved brand as specified and directed. Sona make- Heavy type.
3.3.2 Supplying fitting and fixing chrome plated (C.P) stop-cock of approved brand of size as mentioned below as directed and specified (G.I & C.P. pipes will be measured and paid separately). Jaquare (a) Continental/Clarion. (i) 15mm dia. (Angular stopcock)
1.22 Providing, fitting and fixing CP soap tray/soap dish complete as directed and specified. Jaquare make- Queen's (Cat No. AQN- 7731)
1.15.2 Providing, fitting and fixing CP towel rail complete as directed and specified. Sona make - Towel rail Diplomat 600mm long (Cat. No. TR- 0605)
1.19 Providing fitting and fixing Decorative Mirror complete as directed and specified. Parryware Make- Size 600mm X 450mm
Supplying fitting and fixing Chrome plated (C.P) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) Jaquare make - Continental - Overhead shower (ABS chrome plated) with rubit cleaning system
Supplying fitting and fixing Chrome plated (C.P) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) Jaquare make - Continental - Overhead shower (ABS chrome plated) with rubit cleaning system C.P. Grating - 110mm dia
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (Sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm X 450mm X 450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12mm brick wall in cement mortar in proportion 1:2 in side wall and floor 450mm X 450mm air tight C.I. inspection pit cover and frame complete including supplying at amaterials, necessary excavation of pit as directed.
INTERNAL ELECTRIFICATION WORKS: 2.2.2 Wiring to 5 a pin 6 Amps plug point with 1.5 sq.m mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR kable/Nicco/Anchor or equivalent make as approved by the deptt.) in surface/recessed 2mm thick/heavyrigid ISI marked IS: 9537 PART- III rigid PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) wring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta/Gold medal/Kolor kany.kom/Havells or equivalent make as approved by the deptt.) GI./M.S. switch board. (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq.mm cable to third pin of the plug socket etc. as required complete when placed elsewhere. Medium point up to 6.00 metre. Length.
2.5.1 Wiring for light/fan/call bell point with 3 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex /RR Kable/Nicco/Anchor or equivalent make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2 mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/AKG/Precision/Presto Plast/polycab/MW or equivalent makes as approved by the Deptt.) including 6 Amp flush type switch/bell push (Anchor Penta/ Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked)with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete Short point up to 3.00 metre length.
2.6.1 Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel/Nicco/Anchor or Equivalent make as approved by the deptt.) in surface/recessed PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) wiring system. With 2 X 1.5 sq.mm cable in 20mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.6.2 Wiring for circuit wiring with P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR kable/ Nicco/Anchor or equivalent Make as approved by the deptt.) in surface/recessed PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) Wiring system. With 3 X 1.5 sq.mm cable in 20 mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part-III conduit.
2.7.1 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.) PVC conduit (Berlia/ AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. With 2 X 2.5 sq.mm + earth continuity with 1 X 1.5 sq.mm cable in 20mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7.2 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.) PVC conduit (Berlia/ AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. With 2 X 4 sq.mm + earth continuity with 1 X 2.5 sq.mm cable in 20mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7.3 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.) PVC conduit (Berlia/ AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. With 2 X 6 sq.mm + earth continuity with 1 X 4 sq.mm cable in 25mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.9.4 Wiring for drawing sub-main line with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed PVC 20mm dia. 2mm thick/heavy ISI marked IS:9537PART- III rigid PVC conduit (Berlia/AKG /Precision/Presto Plast/Polycab/M.W or equivalent make as approved by the deptt.) Wiring system. With 4 X 10 sq.mm + earth continuity with 2 X 6 sq.mm cable in 40 mm dia 2mm thick/heavy rigid PVC IS: 9537 Part-III conduit.
2.16.2 Wiring for twin control light point with 1.5 sq. mm PVC insulated single core insheathed industrial (Multistrand) cable FR conforming to IS-694 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kable/Nicco/Achor or equivalent make as approved by the deptt.) in surface/recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS:9537 Part III conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including 6 amp flush type 2 way switch (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the deptt.) GI/MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the deptt.) etc. complete. Medium point up to 6.00 metra length.
2.17.1 Wiring for light/fan/call bell point with 3 X 1.5 sq.mm P.V.C. insulated single core unsheathed industrial (Multistanderd) cable FR confirming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR KABLE/Nicco/ Anchor or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2mm thick /heavy rigid PVC IS: 9537 part-III conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) celling rose etc. Complete Short point up to 3.00 metre length
2.17.2 Wiring for light/fan/call bell point with 3 X 1.5 sq.mm P.V.C. insulated single core unsheathed industrial (Multistanderd) cable FR confirming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR KABLE/Nicco/ Anchor or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2mm thick /heavy rigid PVC IS: 9537 part-III conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) celling rose etc. Complete Medium point up to 6.00 metre length
2.17.2 Wiring for light/fan/call bell point with 3 X 1.5 sq.mm P.V.C. insulated single core unsheathed industrial (Multistanderd) cable FR confirming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR KABLE/Nicco/ Anchor or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2mm thick /heavy rigid PVC IS: 9537 part-III conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) celling rose etc. Complete Long point up to 10.00 metre length
11.1 Supplying and fixing of batten holder (Anchor Penta PC CHERRY/Gold medal/Kolor kany.kom/Havells or equivalent make as approved by the deptt.) including connection as approved by the deptt.) as required without lamp.
11.25 Supplying and fitting of 11/15 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt.
15.1.1.1 Supplying with fitting and fixing sheet steel, phosphatised powder painted single door surface mounting MCB DB incorporated with bus-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way SPN single door.
15.2.1.1 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, earth bar and din rail etc. fitted on wall with grounting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand , Hager make) 4 way SPN double door.
15.2.1.3 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, earth bar and din rail etc. fitted on wall with grounting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand , Hager make) 8 way SPN double door.
15.21.1.1 Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised powder painted single door surface mounting vertical TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar up to 125A and din rail etc. fitted on wall with grounting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager make) 4 way TPN (4+12) single door
16.1.1.2 Supplying with fitting and fixing single pole 10KA 240/415V 50HzMCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 40A
16.1.2.1 Supplying with fitting and fixing single pole 10KA 240/415V 50HzMCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 6 to 32A
16.3.1.2 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt. B Series (ABB, Schneider MG, legrand , hager make) 40A
16.16.1.4 Supplying with fitting and fixing panel mounting open execution 25KA 415V 50HZ 4P MCCB (ICS=ICU, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand , Siemens, Indo Asian make) 63A
16.17.1.1 Supplying with fitting and fixing panel mounting open execution 35/36 KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Iron setting 0.7) (Without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415v 50Hz 4P MCCB (Schneider, legrand, Siemens make) 160A
22.8 Supplying, installation & testing of G.I earth station with perforated 50mm dia and 3.00 meter long heavy duty G.I. pipe with necessary 50mm dia G.I fittings such as socket, tee, elbow, nipple and 65mm X 50mm G.I reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner and outer surface of wall as specified and directed by the Deptt.
22.12 Extra for using salt (5 Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.14 Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
22.15 Supplying and laying of 6 SWG G.I earth from Earth Electrode (below G.L) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
22.28 Supply, fitting & fixing 20mm X 5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc. including riveting, soldering and making connection as approved by the Deptt. with earth electrocode G.I. strips and loghting Arrestor etc. as specified and directed by the deptt.
27.1.6 Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections etc,. as approved by the deptt.) as directed by the Department. [Without regulator] Standard model 1200 mm sweep Usha make)/ Standard model 1050/ 1200mm Sweep Havells make)/ High Speed 1200mm sweep (ORIENT PSPO make)
27.2.1.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the deptt.) as required complete and as directed by the deptt. Domestic - Power Flow 225mm sweep (ORIENT make)
27.6.2 Sweeping, fitting & Fixing of Electronic Regulator as required complete.
Philips LED bults non-dimmable 7 W or equivalent as approved by the deptt.
8.13.1 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 1-2 module type Metal
8.13.1 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 3 module type Metal
8.13.4 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 6 module type Metal
8.13.4 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 12 module type Metal
8.13.7 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 3 module
8.14.5 Supplying including fitting and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 6 module
8.14.5 Supplying including fitting and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/recessed system complete as per direction of department. 12 module
8.24 Supplying including installation of socket outlet 6/16 amps 3/5 pin combine shuttered complete MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
8.26 Supplying including installation of socket outlet 6 Amps 3 pin universal combine shuttered complete MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
8.27 Supplying with fitting fixing of 10/16 amp one way modular clip in switch MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND /PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
8.28 Supplying with fitting fixing of 6 amp one way modular clip in switch MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND /PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Repairing of old Academic Building: STEEL WORK: 18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) a) From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam steel /RINIL (ii) Super Ductile (SD) TMT reinforcement bars
18.1.2 Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.
18.3.1 providing, fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. circular hollow section conforming to relevant I.S. code as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. (a) TATA make Circular hollow section - CHS of grade YST-310 conforming to IS specification: 1161-1998
CEMENT CONCRETE WORK: 2.2.1 Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level. (ii) Column, pillars, posts, struts, suspended floor, roof, landing, shelf and support balcony, lintel, sill band beam girder, bressumer, cantilever, staiecase(except spiral staircase and landing) including preparing the top surface and finishing of noising. N) Without using admixture, plasticiser (a) M 15 grade concrete or Prop 1:2:4
2.2.4 Extra over item Nos. 2.2.1 (I)(B), above for each subsequent floor or part thereof above the 1st floor level.
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, Pillars, Posts & Strut (a) Square, Rectangular, Polygonal in plan or any shape like Tee/L etc. having plane vertical face (ii) Using 25mm thick plank
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.4 Sides and soffits of Beams, Beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (ii) Using 25mm thick plank
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level ( protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement moratar in proportion 1:4 (1 cement: 4 sand)
4.1.14 Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/ R.B wall
WOOD WORK: 9.1.2 Providing wood work in frame (chowkaths) of doors, windows, clearstory window and other similar works wrought, framed and fixed in position in contant with C.C. or brick masonry wall including supplying, fitting and fixing M.S. hold fast (40mm X 3mm X 250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber face in contact wit C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/sundi)
9.9.2 Providing fitting and fixing full panelled doors/windows including oxidised M.S butt hings (100mm X 75mm X 3.55mm) with necessary screw (other fittings to be measured and paid separately) B. With 1st class local wood (Gamari/Hollock/Bonsum) (ii) 35mm thick
ALUMINIUM WINDOWS & VENTILATOR: 11.1.3 Providing, fitting and fixing coloured anodized aluminium windows and ventilators of standered sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifications) fitted with 6mm X 3.15mm lugs 100mm long embedded in CC blocks 150mm X 100mm X 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (cement concrete to be measured and paid separately). (b) Fixed window and ventilators (iv) 5mm clear glass
FLOORING: 5.1.3 40mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15mm thick wearing layer in cement concrete in prop 1:1:2 (ccement : 1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area, wearing layer in to be laid in panels including curing etc. complete as directed.
PLASTERING WORKS: 6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (B) On fair side (b) In cement mortar 1:4
6.2.5 Extra over item no. 6.2.1 to 6.2.3 for plastering on ceiling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
6.2.3 20mm thick cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15mm and finishing coat 5mm thick) b) In cement mortar 1:4
6.2.5 Exra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
ROOFING 8.1.1 Providing corrugated galvenised iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25mm dia X 3mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss purlin etc. (Roof truses and and purlinth etc. to be measured and paid (iii) 0.50mm thick
8.1.2 Providing galvd iron ridging of TATA SHAKTEE/SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. (iii) 0.50 mm thick (i) 150mm lapping
FALSE CEILING (E-GRID) 7.10.1 Providing and fixing, in position suspended false ceiling using E-Gird (exposed ceiling suspension 2430 system) of grid size 600mm X 600mm/ 1200mm X 600mm with main runner 38 X 24mm, cross tee 29mm X 24mm & wall angle 24mm X 24mm. Using 4mm/6mm thick High Presure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S. bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts. (A) Standard Ceilings of Everest make or equivalent as directed by the department. (ii) Using 6mm thick FC Board
PAINTING: 13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surfaces by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (b) With ready mixed paint,wood primer (White)
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint /Berger paint/ ICI paint/ J&N paint/ Nerolac) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter sand papering and stooping. (i) Surfaces over 1000mm in width or girth. (b) high gloss (Asian paint/ Berger paint/ISI paint/J&N paint/Nerolac).
13.4.1 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/J&N paint/Nerolac) on new surface to give an even shade after thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. (a) Acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
13.4.5 Extra over item no 13.4.1 above for painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on celling and on sloping roof.
DOOR WINDOWS FITTINGS 15.2.1 Supplying, fitting , fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & stain finished)
29.1.2 Providing controlled precolating (C.P.) hose ISI Marked (IS: 8423) 63mm X 15mm long complete with instantaneous type Gun Metal 63mm dia ISI Marked male & female couplings (IS: 903) bound & riveted to hose pipe with copper rivets and copper wire complete as required. (MAKE: NIRMAL RUBBER.NEWAGE)
Existing Administrative Building: STEEL WORK: 18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) a) From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam steel /RINIL (ii) Super Ductile (SD) TMT reinforcement bars
18.1.2 Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.
18.3.1 providing, fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. circular hollow section conforming to relevant I.S. code as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. (a) TATA make Circular hollow section - CHS of grade YST-310 conforming to IS specification: 1161-1998
CEMENT CONCRETE WORK: 2.2.1 Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level. (ii) Column, pillars, posts, struts, suspended floor, roof, landing, shelf and support balcony, lintel, sill band beam girder, bressumer, cantilever, staiecase(except spiral staircase and landing) including preparing the top surface and finishing of noising. N) Without using admixture, plasticiser (a) M 15 grade concrete or Prop 1:2:4
2.2.4 Extra over item Nos. 2.2.1 (I)(B), above for each subsequent floor or part thereof above the 1st floor level.
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, Pillars, Posts & Strut (a) Square, Rectangular, Polygonal in plan or any shape like Tee/L etc. having plane vertical face (ii) Using 25mm thick plank
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.4 Sides and soffits of Beams, Beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (ii) Using 25mm thick plank
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
3.1.1.5 Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness. (ii) Using 25mm thick plank.
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
BRICK WORK: 4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level ( protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement moratar in proportion 1:4 (1 cement: 4 sand)
4.1.14 Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/ R.B wall
WOOD WORK: 9.1.2 Providing wood work in frame (chowkaths) of doors, windows, clearstory window and other similar works wrought, framed and fixed in position in contant with C.C. or brick masonry wall including supplying, fitting and fixing M.S. hold fast (40mm X 3mm X 250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber face in contact wit C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/sundi)
9.9.2 Providing fitting and fixing full panelled doors/windows including oxidised M.S butt hings (100mm X 75mm X 3.55mm) with necessary screw (other fittings to be measured and paid separately) B. With 1st class local wood (Gamari/Hollock/Bonsum) (ii) 35mm thick
ALUMINIUM WINDOWS & VENTILATOR: 11.1.3 Providing, fitting and fixing coloured anodized aluminium windows and ventilators of standered sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifications) fitted with 6mm X 3.15mm lugs 100mm long embedded in CC blocks 150mm X 100mm X 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (cement concrete to be measured and paid separately). (b) Fixed window and ventilators (iv) 5mm clear glass
FLOORING: 5.1.3 40mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15mm thick wearing layer in cement concrete in prop 1:1:2 (ccement : 1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area, wearing layer in to be laid in panels including curing etc. complete as directed.
PLASTERING WORKS: 6.2.1 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 1st floor level including arises or roundred angels not exceeding 80mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
6.2.5 Extra over item no. 6.2.1 to 6.2.3 for plastering on ceiling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
PLASTERING WORKS: 6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (B) On fair side (b) In cement mortar 1:4
6.2.5 Extra over item no. 6.2.1 to 6.2.3 for plastering on ceiling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
6.2.3 20mm thick cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15mm and finishing coat 5mm thick) b) In cement mortar 1:4
6.2.5 Exra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
ROOFING: 8.1.33 Providing pre painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/Dyna roof/ Durakolor/Wonder Roof or equivalent as directed by the Department. (iii) 0.50 mm thick
8.1.34 Providing pre-painted Galvanized iron sheet (PPGI) accessories (Ridging/Valley /Gutter/ Flashing) at all levels including fitting and fixing self drilling, self tapping screws comlete. TATA Blue scope/Dyna roof/ Durakolor/Wonder Roof or equivalent as directed by the Department (iii) 0.50mm thick
FALSE CEILING (E-GRID) 7.10.1 Providing and fixing, in position suspended false ceiling using E-Gird (exposed ceiling suspension 2430 system) of grid size 600mm X 600mm/ 1200mm X 600mm with main runner 38 X 24mm, cross tee 29mm X 24mm & wall angle 24mm X 24mm. Using 4mm/6mm thick High Presure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S. bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts. (A) Standard Ceilings of Everest make or equivalent as directed by the department. (ii) Using 6mm thick FC Board
PAINTING: 13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surfaces by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (b) With ready mixed paint,wood primer (White)
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint /Berger paint/ ICI paint/ J&N paint/ Nerolac) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter sand papering and stooping. (i) Surfaces over 1000mm in width or girth. (b) high gloss (Asian paint/ Berger paint/ISI paint/J&N paint/Nerolac).
13.7.2(a) Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly clearing oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/red oxide" primer.
13.7.4 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ICI paint/J&N paint/Nerolac paint) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter. (b) High gloss (Asian paint/Berger paint/ICI paint/ J&N paint/Nerolac).
13.4.1 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/J&N paint/Nerolac) on new surface to give an even shade after thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. (a) Acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
13.4.5 Extra over item no 13.4.1 above for painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on celling and on sloping roof.
DOOR WINDOWS FITTINGS 15.2.1 Supplying, fitting , fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & stain finished)
INTERNAL ELECTRICAL WORKS: 2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.1 SP upto 3.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.2 MP upto 6.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.3 LP upto 10.00 metre length
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.1 SP upto 3.00 metre length
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.1 MP upto 6.00 metre length.
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.3 LP upto 10.00 metre length.
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.1 SP upto 3.00 metre length.
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.2 MP upto 6.00 metre length.
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.3 LP upto 10.00 metre length.
2.6.2 Wiring for circuit wiring with P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR kable/ Nicco/Anchor or equivalent Make as approved by the deptt.) in surface/recessed PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) Wiring system. With 3 X 1.5 sq.mm cable in 20 mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part-III conduit.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.1 With 2 X 2.5 sq.mm + earth continuity with 1 X 1.5 sq.mm cable in 20mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.2 With 2 X 4 sq.mm + earth continuity with 1 X 2.5 sq.mm cable in 20mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.3 With 2 X 6 sq.mm + earth continuity with 1 X 4 sq.mm cable in 25mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.9 Wiring for drawing sub-main line with P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed PVC 20mm dia. 2mm thick/heavy ISI marked IS:9537PART- III rigid PVC conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/M.W or equivalent make as approved by the deptt.) Wiring system. 2.9.4 With 4 X 10 sq.mm + earth continuity with 2 X 6 sq.mm cable in 40 mm dia 2mm thick/heavy rigid PVC IS: 9537 Part-III conduit.
2.9 Wiring for drawing sub-main line with P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed PVC 20mm dia. 2mm thick/heavy ISI marked IS:9537PART- III rigid PVC conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/M.W or equivalent make as approved by the deptt.) Wiring system. 2.9.5 With 4 X 16 sq.mm + earth continuity with 2 X 10 sq.mm cable in 40 mm dia 2mm thick/heavy rigid PVC IS: 9537 Part-III conduit.
B. SWITCH/SOCKET/PLATE ETC. SB 8.4 Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.5 Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.7 Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.8 Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.13 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) in surface/ recessed system complrtr as per direction of department. 8.13.4 4 module
SB 8.13 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) in surface/ recessed system complrtr as per direction of department. 8.13.6 6 module
SB 8.13 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) in surface/ recessed system complrtr as per direction of department. 8.13.9 9 module
SB 8.14 Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) front plate of suitable colour as per direction of department. 8.14.4 4 module
SB 8.14 Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) front plate of suitable colour as per direction of department. 8.14.5 6 module
SB 8.14 Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) front plate of suitable colour as per direction of department. 8.14.7 9 module
SB 8.18 Supplying with fitting fixing of blank plate single in modular switch system, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES. 11.10 Supplying and fixing of Plain Pendent holder (Anchor Penta PC CHERRY/Gold medal/ Kolor kany.kom/Havells or equivalent make as approved by the deptt.) with twin twisted flexible cable connection as approved by the deptt.) as required without lamp.
Supplying, installation, testing and commission of the following indoor surface Mounted LED Luminaries complete with all accessories such as driver etc. and necessary connection with 1.5 sq. mm PVC insulated S.C. copper conductor as required and as directed by the deptt. Philips lighting luminaire 15W Cirrus Mini Model SM518C LED9S 6500 PSU OD GR/ SM518C LED9S 6500 PSU OD WH or equivalent as approved by the deptt.
Supplying, installation, testing and commission of the following indoor surface Mounted and Suspended Luminaries LED Luminaries complete with all accessories such as driver etc. and necessary connection with 1.5 sq. mm P.V.C insulated S.C. copper conductor as required and as directed by the deptt. Philips 24W, Astra Surface & wall mounted LED batten Model BN150W LED20S-6500 PSE OD GR or equivalent as approved by the deptt.
Supplying, installation, testing and commission of the following LED lamp as directed by the deptt. Philips LED bulbs non-dimmable 7 W or equivalent as approved by the deptt.
11.32 Supplying and fixing of Cell bell (Buzzer) including 5/6 amp capacity button piano type bell push switch including connection as approved by the Deptt.) as required.
D. EARTHING: 22.7 Installation of earth station with 40mm dia and 4.5ltr. Long GI pipe with necessary GI reducing socket 40mm X 20mm size locking arrangement with hinged cover plate, funnel, GI nuts, through bolts etc. for putting pipe and refitting with necessary enclosure on the top etc.as required complete.
22.12 Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
22.15 Supplying and laying with 6 SWG G.I earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc. as required complete.
E. CEILING/EXHAUST FAN ECBC 1.1 Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the department [Without regulator]. (ORIENT PSPO make/ Usha make/ CROMPTON make/ Havells/ATC/V GAURD make) ECBC 1.1.1 Energy efficient 5-star 1200mm sweep. ORIENT PSPO/ Usha/CROMPTON/Havelles/ATC or equivalent make fusion 5 star (Havells or equivalent make)
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1.2 Power flow 225mm sweep (ORIENT make)
F. MCB/MCBDB/RCCB ETC. 15.2 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door (IP-43) surface mounting SPN MCB DB incorporated with bus-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts & bolts as required. complete with making necessary connection as approved, specified as directed by the department. 15.2.1 ABB, Schneider MG, legrand, Hager make) 15.2.1.4 12 way SPN Double Door.
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.2 C series 16.1.2.1 6-32A
16.8 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.8.2 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.8.2.2 40A
16.7 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.7.1 30mA sensitivity DP RCCB 16.7.1.2 40A
SANITARY WORKS: 1.2 Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead, CP brass hinges and rubber buffers, CI/MS brackets, 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make b) Coloured (ii) Combination Closet S Trap (Cat No. C0205) (inclusive of seat cover)
1.8 Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standered flush pipe and CP brass spreader and brass urines, etc. complete including painting of fitting and brackets, cutting and making good the walls & floors wherever required. (A) Parryware make (a) White (ii) Aquaseal (Cat. No. C0508)
1.9 Providing fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader and brass union, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. A) Parryware make (i) White (Cat. No. C0503)
1.5 Supplying, fitting and fixing PVC flushing cistern with all internal fittngs with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) (i) Parryware make, (a) White (ii) Delux single flush (Cat. No. C8091/C8057)
1.13.1 Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) (A) Parryware make (a) White (iii) Qube 600 X 460 (Cat. No. C844D/G) (white/coloured)
1.19 Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (b) Size 600mm X 450mm
1.22 Providing, fitting and fixing CP soap tray/soap dish complete as directed and specified. (I) Jaquare make (b) Queen's (Cat. No. AQN-7731)
1.24 Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquare make (i) Continental 300mm for wash basin (Cat. No. CAN-1101N)
1.37. Supplying, fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (a )In exposed surfaces or in trenches. (ii) 110mm dia.
1.37. Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a )In exposed surfaces or in trenches. (ii) 110mm dia.
1.37. Supplying, fitting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a )In exposed surfaces or in trenches. (ii) 110mm dia.
1.37. Supplying, fitting and fixing PVC single 'Y' of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a )In exposed surfaces or in trenches. (ii) 110mm dia.
1.51 Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/ chatcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (Size of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of sures as mentioned in the table.
1.36 Supplying, fitting and fixing ISI marked or similar approved HCI pipe including bolts and nuts and other fittings as required and complete at all levelsincluding below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (ii) 100mm dia.
WATER SUPPLY WORKS INCLUDING STAGE: 5.4.2 Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of sintex/ polycon/ patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes complete as directed. (iii) 1000 Lt capacity (a) Sintex make
5.4.6 Labour for erecting and placing PCVC Tank over stagging of 5.00m up to 8.00m complete as directed. (c ) 1000 litre capacity
3.1.1 Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L as directed and specified. (A) Exposed on walls (b) 40mm dia (Medium) (i) Using Tata make
3.1.1 Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L as directed and specified. (A) Exposed on walls (d) 25mm dia (Medium) (i) Using Tata make
3.1.1 Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L as directed and specified. (A) Exposed on walls (f) 15mm dia (Medium) (i) Using Tata make
3.2.1 Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P. pipes will be measured separately) (ii) Jaquare make (ii) Bibcock long thread
3.2.1 Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P. pipes will be measured separately) (ii) Jaquare make (iii) 2-Way bib cock
3.3.1 Supplying fitting and fixing stop- cock of approved brand of size as mentioned below and directed and specified. (G.I. & C.P. pipes will be measured separately) (I) Brass stop cock (heavy) of sant make (v) 40mm dia
3.3.1 Supplying fitting and fixing stop- cock of approved brand of size as mentioned below and directed and specified. (G.I. & C.P. pipes will be measured separately) (I) Brass stop cock (heavy) of sant make (iii) 25mm dia
3.6.1 Supplying fitting and fixing chrome plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) (v) Jaqaure brand (A) Continental /Clarion (ii) Sink cock with raised 'J' shaped swinging spout
3.8.2 Supplying fitting and fixing Chrome Plated (C.P) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately). (iii) Jaquare make (ii) Shower arm 190mm long heavy casted body with wall flange
3.8.4 Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately) (II) Lauret make (Telephonic hand shower with 1.5 m PVC pipe with hook)
3.10.1 Supplying , fitting and fixing chrome plated (C.P.) wall mixer complete as directed. (v) Jaquare make (v) Wall mixer 3 in 1 system with provision for both telephonic shower and overhead shower complete with 115mm long bend pipe Cat No. 1119
3.10.1 Supplying , fitting and fixing chrome plated (C.P.) wall mixer complete as directed. (v) Jaquare make (v) Wall mixer 3 in 1 system with provision for both telephonic shower and overhead shower complete with 115mm long bend pipe Cat No. 1119
6.3.1 Supplying and placing Ferrocement Iron Removal Plant over stagging with movable G.I. sheet cover with side ventilation including providing pads of sizes as required for inlet and outlet pipes complete as directed. (Stagging and storage reservoir should be measured and paid separately). (i) 1000 It capacity
Septic Tank (100 users) 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Upto a depth of 2.00m below the existing ground level. i) In ordinary soil
4.1.1 Providing brick work soiling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soiling.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete( shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume. (using mixure machine)
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THEREMAX) (For Assam Type Bldge., drain works, retaining wall & boundary wall etc.)
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 2. Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3. Flat surface such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
2.2.1 Providing & laying reinforcement cement concrete works in prop 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work.(from work and reinforcement will be measured and paid separately) a) In Sub-structure up to plinth level. Foundation, footings, columns with base tie & plinth beam, pile cap, base slab, retaining walls, walls of septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. (a) M15 or Prop 1:2:4
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (i) In Sub-Structure upto plinth level including dewatering if necessary. (a) In proportion 1:3
4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level ( protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement moratar in proportion 1:4 (1 cement : 4 sand)
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (B) On fair side. (b) In cement mortar 1:4
6.2.4 Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacture including curing complete as directed. (ii) 15mm thick plaster. (b) In Cement mortar 1:4
5.1.10 Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick
1.47 Providing fitting and fixing 450mm dia. 90mm thick C.I. man hole cover and frame of 38 Kg. weight complete as directed and specified.
Fire Fighting: 29.1.1 Providing, fixing, testing & Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80mm dia, flanged inlet & 63mm dia instantaneous type femal outlet complete with cap and chain, twist release lug and all accessories as per IS: 5290-19833 (Type-'A') and specifications complete as required (MAKE:ESSEL/WINCO/NEWAGE)
29.1.2 Providing controlled percolating (C.P) hose ISI marked (IS: 8423) 63mm dia X 15mm long complete with instantaneous type Gun Metal 63mm dia ISI marked make & female couplings (IS:903) bound & riveted to hose pipe with copper rivets and copper wire complete as required. (MAKE: NIRMAL RUBBER/NEWAGE)
GYPBOARD CEILING: 7.2.3 Supplying, fitting , fixing and painting where necessary (one coat primer and two coats of paint) pre-coated G.I. angle size 24mm X 24mm X 80mm thick fixed to the brick wall/pertition at the perimeter of ceiling with nylon sleeves and screws, at 610mm c/c, Then suspending main 'T' section (bottom pre-coated) size 24mm X 38mm X 0.70mm and 3600mm long from the soffit in one direction with the help of metal Rawl Plug. Soffit cleat and G.I Rod 4mm diameter with galvanised level clip 1220mm c/c G.I cross. (D) BPB Grid ceiling system with P.V.C laminated plain Gypboard (Polyshield-P) Tiles 9.5mm thick.
WOOD WORK: 9.2.1 Providing undressed wood work in roof truss, rafter, purlin tie and the like including hoisting and fixing in position with necessary spikes nails including M.S. straps with bolt and nuts etc. complete with kiricide oiling two coats to all timber members and two coats of anticorrosive paint to M.S. straps (M.S. flats angle cleats and bolt and nuts required for flat and angles cleats wherever used shall be measured and paid separately.) (a) With Hollock/Sundi/Sam
ROOFING: 8.1.1 Providing corrugated galvenised iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia X 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss purlin etc. (Roof trusses and purlin etc. to be measured and paid separately). (a) 0.45 mm thick
8.1.2 Providing galved iron ridging of TATA SHAKTEE/SAIL including supplying and fixing necessary galved screws/washers etc. complete as directed. (a) 0.45mm thick (i) 150mm lapping.
PAINTING: 13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surfaces by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (b) With ready mixed paint,wood primer (White)
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian /Berger paint/ICI paint/J&N paint/Nerolac) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter sand papering and stooping. (i) Surfaces over 1000mm in width or girth. (b) high gloss (Asian paint/Berger paint/ISI paint/J&N paint/Nerolac).
13.3.1 Providing surface preparation for walls, ceiling etc. using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and plaster of paris paste, making the surfaces even and smooth complete at all levels as specified and directed.
13.3.4 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (ii) Thickness = 1.0 mm thick
13.4.1 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on new surface to give an even shade after thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. (a) Acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
INTERNAL ELECTRICAL WORKS: A.Wiring 2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.1 SP upto 3.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.2 MP upto 6.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.3 LP upto 10.00 metre length
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.1 SP upto 3.00 metre length
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.1 MP upto 6.00 metre length.
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.3 LP upto 10.00 metre length.
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.1 SP upto 3.00 metre length.
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.2 MP upto 6.00 metre length.
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.3 LP upto 10.00 metre length.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.1 With 2 X 2.5 sq.mm + earth continuity with 1 X 1.5 sq.mm cable in 20mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
B. SWITCH/SOCKET/PLATE ETC. SB 8.4 Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.5 Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.7 Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.8 Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.13 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) in surface/ recessed system complrtr as per direction of department. 8.13.4 4 module
SB 8.14 Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) front plate of suitable colour as per direction of department. 8.14.4 4 module
SB 8.18 Supplying with fitting fixing of blank plate single in modular switch system, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES. 11.10 Supplying and fixing of Plain Pendent holder (Anchor Penta PC CHERRY/Gold medal/ Kolor kany.kom/Havells or equivalent make as approved by the deptt.) with twin twisted flexible cable connection as approved by the deptt.) as required without lamp.
Supplying, installation, testing and commission of the following indoor surface Mounted LED Luminaries complete with all accessories such as driver etc. and necessary connection with 1.5 sq. mm PVC insulated S.C. copper conductor as required and as directed by the deptt. Philips lighting luminaire 15W Cirrus Mini Model SM518C LED9S 6500 PSU OD GR/ SM518C LED9S 6500 PSU OD WH or equivalent as approved by the deptt.
Supplying, installation, testing and commission of the following LED lamp as directed by the deptt. Philips LED bulbs non-dimmable 7 W or equivalent as approved by the deptt.
D. EARTHING: 22.7 Installation of earth station with 40mm dia and 4.5ltr. Long GI pipe with necessary GI reducing socket 40mm X 20mm size locking arrangement with hinged cover plate, funnel, GI nuts, through bolts etc. for putting pipe and refitting with necessary enclosure on the top etc.as required complete.
22.12 Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
22.15 Supplying and laying with 6 SWG G.I earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc. as required complete.
E. CEILING/EXHAUST FAN ECBC 1.1 Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the department [Without regulator]. (ORIENT PSPO make/ Usha make/ CROMPTON make/ Havells/ATC/V GAURD make) ECBC 1.1.1 Energy efficient 5-star 1200mm sweep. ORIENT PSPO/ Usha/CROMPTON/Havelles/ATC or equivalent make fusion 5 star (Havells or equivalent make)
F. MCB/MCBDB/RCCB ETC. 15.2 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door (IP-43) surface mounting SPN MCB DB incorporated with bus-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts & bolts as required. complete with making necessary connection as approved, specified as directed by the department. 15.2.1 ABB, Schneider MG, legrand, Hager make) 15.2.1.4 12 way SPN Double Door.
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.2 C series 16.1.2.1 6-32A
16.8 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.8.2 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.8.2.2 40A
Fire Fighting: 29.1.1 Providing, fixing, testing & Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80mm dia, flanged inlet & 63mm dia instantaneous type femal outlet complete with cap and chain, twist release lug and all accessories as per IS: 5290-19833 (Type-'A') and specifications complete as required (MAKE:ESSEL/WINCO/NEWAGE)
29.1.2 Providing controlled percolating (C.P) hose ISI marked (IS: 8423) 63mm dia X 15mm long complete with instantaneous type Gun Metal 63mm dia ISI marked make & female couplings (IS:903) bound & riveted to hose pipe with copper rivets and copper wire complete as required. (MAKE: NIRMAL RUBBER/NEWAGE)
9.2.1 Providing undressed wood work in roof truss, rafter, purlin tie and the like including hoisting and fixing in position with necessary spikes nails including M.S. straps with bolt and nuts etc. complete with kiricide oiling two coats to all timber members and two coats of anticorrosive paint to M.S. straps (M.S. flats angle cleats and bolt and nuts required for flat and angles cleats wherever used shall be measured and paid separately.) (a) With Hollock/Sundi/Sam
ROOFING: 8.1.1 Providing corrugated galvenised iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25 mm dia X 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss purlin etc. (Roof trusses and purlin etc. to be measured and paid separately). (c ) 0.55mm thick.
8.1.2 Providing galved iron ridging of TATA SHAKTEE/SAIL including supplying and fixing necessary galved screws/ washers etc. complete as directed. (c ) 0.50mm thick (i) 150mm lapping.
Ceiling with Exposed MEtal (G.I.) Frame work with E-Gird- 7.10.1 Providing and fixing, in position suspended false ceiling using E-Gird (exposed ceiling suspension 2430 system) of grid size 600mm X 600mm/1200mm X 600mm with main runner 38 X 24mm, cross tee 29mm X 24mm & wall angle 24mm X 24mm. Using 4mm/6mm thick High Presure Steam Cured Non Asbestors Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S. bar hanger fixed with steel dash fastners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by .... (A) Standard Ceilings of Everest make or equivalent as directed by the department (ii) Using 6mm thick FC Board
INTERNAL ELECTRICAL WORKS: 2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.1 SP upto 3.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.2 MP upto 6.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.3 LP upto 10.00 metre length
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.1 SP upto 3.00 metre length
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.1 MP upto 6.00 metre length.
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.3 LP upto 10.00 metre length.
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.1 SP upto 3.00 metre length.
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.2 MP upto 6.00 metre length.
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.3 LP upto 10.00 metre length.
B. SWITCH/SOCKET/PLATE ETC. SB 8.4 Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.5 Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.7 Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.8 Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.13 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) in surface/ recessed system complrtr as per direction of department. 8.13.4 4 module
SB 8.14 Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) front plate of suitable colour as per direction of department. 8.14.4 4 module
SB 8.18 Supplying with fitting fixing of blank plate single in modular switch system, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
F. MCB/MCBDB/RCCB ETC. 15.2 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door (IP-43) surface mounting SPN MCB DB incorporated with bus-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts & bolts as required. complete with making necessary connection as approved, specified as directed by the department. 15.2.1 ABB, Schneider MG, legrand, Hager make) 15.2.1.4 12 way SPN Double Door.
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.2 C series 16.1.2.1 6-32A
16.8 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.8.2 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.8.2.2 40A
1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m below the existing ground level. In ordinari soils
1.3 Earth/Sand filling in plinth in layers not more than 1.50mm thick including necessary carriage, watering ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c )With river sand or silt (Predominantly non plastic) by truck carriage including loading and unloading.
4.1.1 Providing soling in foundation and under floor with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete. a) Brick flat soling
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
2.1.2 Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. Of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. (b) 100mm thick.
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) a) From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam steel /RINIL (ii) Super Ductile (SD) TMT reinforcement bars
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.6 Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string course and the like.
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties (a) For depth not exceeding 1.0M
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Column, pillars posts & struct of square/rectangular/Polygonal in plain or any shape like Tee/L etc having plane vertical face.
2.1.3 Providing and laying 25 mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc.complete as directed.
2.2.1 Providing and laying plain/reinforced cement concrete work , cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In substructre up to plinth level. Foundation, footing, columns with base tie and plinth beam, grade beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture. plasticizer (b) M20 or Prop 1:1.5:3
2.2.1 Providing and laying plain/reinforced cement concrete work , cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (B) In Supar structure from plinth level upto 1st floor level. (ii) Column, pillars, post, struts, suspended floor, roof, landing, shelf and support balcony, lintel, sill band beam girder, bressumer, cantilever, staiecase(exceptspiral staircase and landing)including preparing the top surface and finishing of noising. (b) M 20 grade concrete or Prop 1:1.5:3
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and soffits of beams, beam haunchings, cantilever girders bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0m
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3 Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) floors etc. upto 200mm in thickness.
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure up to plinth level including dewatering if necessary In proportion 1:4
4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level ( protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement moratar in proportion 1:4 (1 cement : 4 sand)
11.1.2 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifications) and providing and fixing handles, angle cleats, rubber gasket, roller, bolting device, locking arrangement, screws etc as required complete as specified and directed for all levels. (a) 2 Track sliding window (i) 6mm clear glass
11.1.1 Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm X 3.15mm lugs 100mm long embedded in CC blocks 150mm X 100mm X 100mm in 1:3:6 mix including providing and fixing handles, frictions, stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately) (a) Side hung and top hung windows and ventilators (i) 6 mm clear glass
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (a) On rough side (b) In cement mortar 1:3
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (a) On rough side (b) In cement mortar 1:4
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (B) On fair side (b) In cement mortar 1:4
18.7.1 Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mm X 40mm X 5mm fabricated, welded, mitred and joined as per relevent IS Codes including fitting 8 nos of MS hold fast providing closing/holding device for 2nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the frame to the wall/R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed.
12.3 Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mm X 60mm (Toletance + l rnm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mm X 100mm or plastic brackels of size 75mm X 75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mm X 20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia steel screws and expandable fastners on each side of the door frame complete in all respects as sepcified and directed at all levels.
12.4 Providing fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made from extruded PVC stiles and rails made from rigid PVC multicavity hollow chember section of size 90mm X 37mm (Toletance + 1mm) . The corners of the stiles and rails shall be metred out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular galvanised two nos of size 200mm X 100mm and. 100mm X 37mm shall be fixed in the middle by aluminium cleat and steel screws as lock rail. The section frame shall then be fuilled with PVC panels of approved colour of size 100mm X 20mm, Then two numbers of bright steel rods of 6mm diameter shall be inserted horizontally through stiles and panels with two numbers of checknuts and washers all complete as specified and directed at all levels. (Door fixtures and fittings to be measured and paid separately)
13.3.4 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick
13.2.3(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.5.2 Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1Ltr. of paint with 750ml of waterto give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department. c) Asian paint/ Berger paint/ ICI paint/ J& N paint/ Nerolac
13.5.3 Extra over item no. 13.5.2 above for every subsequent coat of acrylic emulsion exterior coating of Unicem 'Rakshak' brand of required shade. C) Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac
13.2.2 (c ) Applying one coat of distemper primer of approved brand and manufacture on wall surface after throughly brushing the surfaces free from mortar dropings and other foreign matter and including preparing the surface even and sand prepared smooth.
13.4.1 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on new surface to give an even shade after thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. (a) Acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
13.4.2 Extra over item 13.4.1 above for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/ J & N paint/ Nerolac). (i) Acrylic Emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
5.7.2.1 Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15mm thick in prop. 1:3 (1 providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement slurry mixed with approved pigment to match sgade of tiles, mixed with (b) Executive range Somany/Orient/Nitco/Varmora/VITA/Marbito/Make (i) Of size 800mm X 800mm and above
5.7.1.2 Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less then 8mm on wall and skirting over cement mortar bed 10mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flash pointing with Fix-A-Title (Choksey/Sika/Pedelite/Rouf)/ White cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (Walls means both interior and exterior walls) (a) Normal range Somany/Orient/Nitco/Asian Make (ii) Of Size 200mm X 300mm and above
13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surfaces by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (b) With ready mixed paint,wood primer (White)
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian /Berger paint/ICI paint/J&N paint/Nerolac) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter sand papering and stooping. (i) Surfaces over 1000mm in width or girth. (b) high gloss (Asian paint/Berger paint/ISI paint/J&N paint/Nerolac).
15.1.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete (anodised to bright natural matt & satin finished) b) Tower bolts (ii) 250mm X 12mm
15.1.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete (anodised to bright natural matt & satin finished) c) Door handles (iii) 150mm
15.1.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete (anodised to bright natural matt & satin finished) (m) Mortice lock vertical type (iii) 100mm (Godrej with handle 6 lever)
15.1.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete (anodised to bright natural matt & satin finished) (t) Door stopper with rubber stopper
9.12.1 Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm X 75 mm X 3.5mm) 6nos with necessary wood screws. (b) Non decorative type and block board core. (i) 40 mm thick.
8.1.1 Providing corrugated galvenised iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25mm dia X 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss purlin etc. (Roof trusses and purlin etc. to be measured and paid separately). (b) 0.50 mm thick.
8.1.2 Providing galved iron ridging of TATA SAHKTEE/ SAIL including supplying and fixing necessary galved screws/washers etc. complete as directed. (b) 0.50mm thick. (i) 150 mm lapping.
18.3.1 Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevent I.S. code as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. (a) TATA make Circular Hollow section - CHS of Grade YST-310 conforming to I.S. specification: 1161-1998
7.10.1 Providing and fixing, in position suspended false ceiling using E-Gird (exposed ceiling suspension 2430 system) of gired size 600mm X 600mm/1200mm X 600mm with main runner 38 X 24mm, cross tee 29mm X 24mm & wall angle 24mm X 24mm. Using 4mm/6mm thick High Presure Steam Cured Non Asbestors Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S. bar hanger fixed with steel dash fastners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm X 600mm/1200mm X 600mm grid, all complete as per the drawing & directions of enginner-in-charge. Finally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade/make over a coat of cement primer before installing it on the grid. (B) Designer Ceilings of Everest make or equivalent as directed by the department (ii) Using 6mm thick FC Board
5.1.10 Cement plaster skirting with cement mortar in prop 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (b) 20mm thick
26.1.2 Pre construction anti-termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (When required refill in 200mm thick layers) applying the emulsion @ 5(five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated-with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (trical or euivalant) and water, i.e. 1% solution
INTERNAL ELECTRICAL WORKS: 2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.1 SP upto 3.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.2 MP upto 6.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.3 LP upto 10.00 metre length
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.1 SP upto 3.00 metre length
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.1 SP upto 3.00 metre length.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.1 With 2 X 2.5 sq.mm + earth continuity with 1 X 1.5 sq.mm cable in 20mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
B. SWITCH/SOCKET/PLATE ETC. SB 8.4 Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.5 Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.7 Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.8 Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.13 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) in surface/ recessed system complrtr as per direction of department. 8.13.4 4 module
SB 8.14 Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) front plate of suitable colour as per direction of department. 8.14.4 4 module
SB 8.18 Supplying with fitting fixing of blank plate single in modular switch system, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES. 11.10 Supplying and fixing of Plain Pendent holder (Anchor Penta PC CHERRY/Gold medal/ Kolor kany.kom/Havells or equivalent make as approved by the deptt.) with twin twisted flexible cable connection as approved by the deptt.) as required without lamp.
Supplying, installation, testing and commission of the following indoor surface Mounted LED Luminaries complete with all accessories such as driver etc. and necessary connection with 1.5 sq. mm PVC insulated S.C. copper conductor as required and as directed by the deptt. Philips lighting luminaire 15W Cirrus Mini Model SM518C LED9S 6500 PSU OD GR/ SM518C LED9S 6500 PSU OD WH or equivalent as approved by the deptt.
Supplying, installation, testing and commission of the following LED lamp as directed by the deptt. Philips LED bulbs non-dimmable 7 W or equivalent as approved by the deptt.
D. EARTHING: 22.7 Installation of earth station with 40mm dia and 4.5ltr. Long GI pipe with necessary GI reducing socket 40mm X 20mm size locking arrangement with hinged cover plate, funnel, GI nuts, through bolts etc. for putting pipe and refitting with necessary enclosure on the top etc.as required complete.
22.12 Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
22.15 Supplying and laying with 6 SWG G.I earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc. as required complete.
E. CEILING/EXHAUST FAN 27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1.2 Power flow 225mm sweep (ORIENT make)
F. MCB/MCBDB/RCCB ETC. 15.2 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door (IP-43) surface mounting SPN MCB DB incorporated with bus-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts & bolts as required. complete with making necessary connection as approved, specified as directed by the department. 15.2.1 ABB, Schneider MG, legrand, Hager make) 15.2.1.4 12 way SPN Double Door.
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.2 C series 16.1.2.1 6-32A
16.8 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.8.2 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.8.2.2 40A
Sanitary Works: 2.1.1 Clearance of service septic tank and removing the night soil and debris etc. manually from the tank/chamber to a distant place preferably during holidays or at night by balling out the deposited night soil, buries the same in near by trenches / pit which is digged earlier and covered the same. now the service septic tank is cleaned with clear water and complete as directed by the department. (b) For 100 users
2.1.2 Cleaning & clearing the inspection chamber which in partly filled with night soil connected to septic tank soak pit with both side soil pipe of length 1.80m manually and disposed off the block by pushing with bamboo kamis as directed by the department.
2.3 Renewing vitreous china pedestal type water closet (European type W.C. pan 400mm high) with seat and lead, CP brass hinges and rubber, CI/MS brackets, 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) (A) Parryware make (a) White (i) Universal Closet S Trap (Cat. No. C0271) (Anglo Indian) (Inclusive of seat cover)
2.6 Renewing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. complete as directed and specified (pipes wil be measured separately) A) Parryware make a) White (ii) Deluxe Single Flush (Cat No. C8091/C8057)
2.9 Renwing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (A) Parryware make (a) White (i) New Magnum (Cat. No. C0575)
2.12.1 Renewing wash basin with C.P. brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) a) White (viii) Avon 635 X 510 (Cat. No. C8477/79) (white/coloured)
1.19 Providing fitting and fixing decorative mirror complete as directed and specified. (A) Parryware make (b) Size 600mm X 450mm
1.22 Providing, fitting and fixing CP soap tray/soap dish complete as directed and specified. (i) Jaquar make (b) Queen's (Cat. No. AQN-7731)
1.24 Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquare make. (i) Continental 300mm for wash basin (Cat. No. CAN-1101N)
1.37 Supplying, fitting and fixing PVC pipes of 6 kg/cm2 (Superme/prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
1.37.2 Supplying,fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia
1.37. Supplying,fitting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia
1.37.7 Supplying fitting and fixing PVC single "Y" of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surface or in trenches. (ii) 110mm dia.
1.36.1 Supplying, fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required and complete at all levels including below G.L as directed and specified. A) In exposed surfaces or in tenches. (ii) 100mm dia
Water Supply Works including Stage: 5.4.2 Supplying and placing plastic cylinder vertical claused top (PCVC) tank sintex/ polycon/ patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes complete as directed. (iii) 1000 Lt. capacity (a) Sintex make
5.4.6 Labour or erecting and placing PCVC Tank over the stagging of 5m up to 8m complete as directed. (c ) 1000 litre capacity
3.1.1 Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L as directed and specified. (B) Concealed by chieselling or breaking brick wall/C.C. wall/ R.C.C wall and making good to the damaged structure. (b) 40mm dia (Medium) (i) Using Tata make
3.1.1 Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L as directed and specified. (B) Concealed by chieselling or breaking brick wall/C.C. wall/ R.C.C wall and making good to the damaged structure. (d) 25mm dia (Medium) (i) Using Tata make
3.1.1 Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L as directed and specified. (B) Concealed by chieselling or breaking brick wall/C.C. wall/ R.C.C wall and making good to the damaged structure. (f) 15mm dia (Medium) (i) Using Tata make
4.2.1 SOCKET, REDUCING SOCKET Renewing G.I. socket ZOLOTO-m brand, heavy (a) 15mm dia.
4.2.1 SOCKET, REDUCING SOCKET Renewing G.I. socket ZOLOTO-m brand, heavy (c ) 25mm dia.
4.2.1 SOCKET, REDUCING SOCKET Renewing G.I. socket ZOLOTO-m brand, heavy (d ) 40mm dia.
4.2.2 Renewing G.I. Reducing socket (heavy) as specified and (a) 20mm X 15mm size
4.2.2 Renewing G.I. Reducing socket (heavy) as specified and (b) 25mm X 20mm size
4.2.2 Renewing G.I. Reducing socket (heavy) as specified and (c ) 40mm X 25mm size
4.3.1 Renewing G.I. bend (heavy quality) as specified & directed. (a) 15mm dia
4.3.1 Renewing G.I. bend (heavy quality) as specified & directed. (c ) 25mm dia
4.4.1 Renewing G.I. Tee (heavy quality) as specified & directed. (a) 15mm dia.
4.4.1 Renewing G.I. Tee (heavy quality) as specified & directed. (c ) 25mm dia.
4.4.1 Renewing G.I. Tee (heavy quality) as specified & directed. (e ) 40mm dia.
4.4.2 Renewing G.I. Reducing tee (heavy) as specified and (b) 25mm X 15mm size
4.4.2 Renewing G.I. Reducing tee (heavy) as specified and (e) 40mm X 25mm size
3.2.1 Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P. pipe will be measured separately) (ii) Jaquare make (ii) Bibcock long thread.
3.3.1 Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) (I) Brass stop cock (heavy) of Sant make (v) 40mm dia
3.3.1 Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) (I) Brass stop cock (heavy) of Sant make (iii) 25mm dia
3.8.4 Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately) (II) Lauret make (Telephonic hand shower with 1.5 m PVC pipe with hook)
Septic Tank: 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m below the existing ground level. In ordinari soils
4.1.1 Providing soling in foundation and under floor with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete. a) Brick flat soling
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) (b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg, drain works, retaining wall & boundary wall etc.
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure up to plinth level including dewatering if necessary In proportion 1:4
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.5 Flat surfaces such as soffits of suspended floors, roofs, landing, cantilever slabs, chajjas, balconies and the like (II) Using 25mm thick plank.
2.2.1 Providing and laying plain/reinforced cement concrete work , cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (a) In substructre up to plinth level. Foundation, footing, columns with base tie and plinth beam, grade beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. Without using admixture. plasticizer (b) M20 or Prop 1:1.5:3
4.1.7 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement moratar in proportion 1:5
6.2.3 20mm thick cement wall plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. On rough side (backing coat 15mm and finishing coat 5mm thick) In cement mortar 1:4
UPGRADATION WORKS: PAINTING: 13.4.1 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/J&N paint/Nerolac) on new surface to give an even shade after thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. (a) Acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
EARTH WORK: 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. (a) Up to a depth of 2.00m below the existing ground level. In ordinary soils
1.3 Earth/Sand filling in plinth in layers not more than 1.50mm thick including necessary carriage, watering ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With river sand or silt (Predominantly non plastic) by truck carriage including loading and unloading.
STEEL WORK: 18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg, drain works, retaining wall & boundary wall etc.
18.3.1 Providing, fitting, hoisting and fixing of roof trusses including purlins fabricated using M.S. circular hollow section conforming to relevent I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section.
CEMENT CONCRETE WORK: 2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
2.2.1 Providing & laying reinforcement cement concrete works in prop 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work.(from work and reinforcement will be measured and paid separately) a) In Sub-structure up to plinth level. Foundation, footings, columns with base tie & plinth beam, pile cap, base slab, retaining walls, walls of septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. (a) M15 or Prop 1:2:4
2.2.1 Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level. (ii) Column, pillars, posts, struts, suspended floor, roof, landing, shelf and support balcony, lintel, sill band beam girder, bressumer, cantilever, staiecase(except spiral staircase and landing) including preparing the top surface and finishing of noising. N) Without using admixture, plasticiser (a) M 15 grade concrete or Prop 1:2:4
SHUTTERING & FORMWORK: 3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footing, bases of columns, pile cap, raft and mass concrete work etc. (ii) Using 25mm thick plank
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.2 Sides of tie beams, grade beams etc. at or below ground level. (ii) Using 25mm thick plank.
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (ii) using 25mm thick plank.
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.4 Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (ii) Using 25mm thick plank.
BRICK WORK: 4.1.1 Providing soling in foundation and under floor with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete. a) Brick flat soling
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure up to plinth level including dewatering if necessary (b) In proportion 1:4
4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level ( protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement moratar in proportion 1:4 (1 cement : 4 sand)
WOOD WORK: 9.1.2 Providing wood work in frame (chowkaths) of doors, windows, clearstory window and other similar works wrought, framed and fixed in position in contant with C.C. or brick masonry wall including supplying, fitting and fixing M.S. hold fast (40mm X 3mm X 250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber face in contact wit C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/sundi)
9.9.2 Providing fitting and fixing full panelled doors/windows including oxidised M.S butt hings (100mm X 75mm X 3.55mm) with necessary screw (other fittings to be measured and paid separately) B. With 1st class local wood (Gamari/Hollock/Bonsum) (ii) 35mm thick
ALUMINIUM WINDOWS & VENTILATOR: 11.1.3 Providing, fitting and fixing coloured anodized aluminium windows and ventilators of standered sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifications) fitted with 6mm X 3.15mm lugs 100mm long embedded in CC blocks 150mm X 100mm X 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (cement concrete to be measured and paid separately). (b) Fixed window and ventilators (iv) 5mm clear glass
ROOFING 8.1.1 Providing corrugated galvenised iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25mm dia X 3mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss purlin etc. (Roof truses and and purlinth etc. to be measured and paid (iii) 0.50mm thick
Ceiling with Exposed Metal (G.I.) Frame work with E-Grid): 7.10.1 Providing and fixing, in position suspended false ceiling using E-Gird (exposed ceiling suspension 2430 system) of gired size 600mm X 600mm/1200mm X 600mm with main runner 38 X 24mm, cross tee 29mm X 24mm & wall angle 24mm X 24mm. Using 4mm/6mm thick High Presure Steam Cured Non Asbestors Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S. bar hanger fixed with steel dash fastners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm X 600mm/1200mm X 600mm grid, all complete as per the drawing & directions of enginner-in-charge. Finally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade/make over a coat of cement primer before installing it on the grid. (A) Standard Ceilings of Everest make or equivalent as directed by the department (ii) Using 6mm thick FC Board
FLOORING: 5.1.4 65mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6(1cement :3 coarse sand :6 coarse aggregate of 25mm and down) and 15mm thick wearing layer in cement concrete in prop. 1:1:2(1cement :1coarse sand :2coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish(using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (B) On fair side (b) In cement mortar 1:4
6.2.3 20mm thick cement wall plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (A) On rough side (backing coat 15mm and finishing coat 5mm thick) In cement mortar 1:4
PAINTING: 13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surfaces by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (b) With ready mixed paint,wood primer (White)
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian /Berger paint/ICI paint/J&N paint/Nerolac) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter sand papering and stooping. (i) Surfaces over 100mm in width or girth. (b) high gloss (Asian paint/Berger paint/ISI paint/J&N paint/Nerolac).
13.4.1 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/J&N paint/Nerolac) on new surface to give an even shade after thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. (a) Acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
15.2.1 Supplying, fitting , fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & stain finished)
INTERNAL ELECTRICAL WORKS: 2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.1 SP upto 3.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.2 MP upto 6.00 metre length
2.11 Wiring for light/fan/call bell point with 2 X 1.5 sq.m mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed conduit wiring system with 2mm thick 20mm dia rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.11.3 LP upto 10.00 metre length
2.12 Wiring for 5 a pin 6 Amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in recessed 2mm thick rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) complete. 2.12.1 SP upto 3.00 metre length
2.13 Wiring for 5 a pin 16 Amps power plug point with 4 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system including earth continuity with 2.5 sq.mm cable to be 3rd pin of the socket as required complete with 2mm thick 20mm. dia. rigid low halogen SFT PVC IS :9537 PART-III conduit (Berlia/AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) 2.13.1 SP upto 3.00 metre length.
2.7. Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.) PVC conduit (Berlia/ AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.1 With 2 X 2.5 sq.mm + earth continuity with 1 X 1.5 sq.mm cable in 20mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
B. SWITCH/SOCKET/PLATE ETC. SB 8.4 Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
SB 8.5 Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTEE (MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES. 11.10 Supplying and fixing of Plain Pendent holder (Anchor Penta PC CHERRY/Gold medal/ Kolor kany.kom/Havells or equivalent make as approved by the deptt.) with twin twisted flexible cable connection as approved by the deptt.) as required without lamp.
Supplying, installation, testing and commission of the following indoor surface Mounted LED Luminaries complete with all accessories such as driver etc. and necessary connection with 1.5 sq. mm PVC insulated S.C. copper conductor as required and as directed by the deptt. Philips lighting luminaire 15W Cirrus Mini Model SM518C LED9S 6500 PSU OD GR/ SM518C LED9S 6500 PSU OD WH or equivalent as approved by the deptt.
Supplying, installation, testing and commission of the following LED lamp as directed by the deptt. Philips LED bulbs non-dimmable 7 W or equivalent as approved by the deptt.
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the deptt.) as required complete and as directed by the deptt. 27.2.1.2 Power Flow 225mm sweep (ORIENT make)
F. MCB/MCBDB/RCCB ETC. 15.2 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door (IP-43) surface mounting SPN MCB DB incorporated with bus-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts & bolts as required. complete with making necessary connection as approved, specified as directed by the department. 15.2.1 ABB, Schneider MG, legrand, Hager make) 15.2.1.4 12 way SPN Double Door.
Boundary Wall 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified.
4.1.1 Providing soling in foundation and under floor with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete.
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (Upto 1st floor level) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg, drain works, retaining wall & boundary wall etc.
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (ii) Using 25mm thick plank
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.2 Sides of the beams grade beams etc. at or below ground level. (ii) Using 25mm thick
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pilars, posts & strut (a) Square, Rectangular, Polygonal in plan or any shape like Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.4 Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal etc. (a) For depth not exceeding 1.0M (ii) Using 25mm thick plank.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering works where necessary shall be measured and paid separately. Complete but excluding cost of form work and reinforcement. (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
2.2.1 Providing & laying reinforcement cement concrete works in prop 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work.(from work and reinforcement will be measured and paid separately) a) In Sub-structure up to plinth level. Foundation, footings, columns with base tie & plinth beam, pile cap, base slab, retaining walls, walls of septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. (a) M15 or Prop 1:2:4
2.2.1 Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level. (ii) Column, pillars, posts, struts, suspended floor, roof, landing, shelf and support balcony, lintel, sill band beam girder, bressumer, cantilever, staiecase(except spiral staircase and landing) including preparing the top surface and finishing of noising. N) Without using admixture, plasticiser (a) M 15 grade concrete or Prop 1:2:4
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. (b) In proportion 1:4
4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement moratar in proportion 1:5
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (a) On rough side (b) In cement mortar 1:4
6.2.3 20mm thick cement wall plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
13.2.1 (a) Colour washing with lime on wall surface (two coats) over and including a priming coat of white washing to give an even shade after throughly brooming the surface to remove all dirt, dust, mortar drops and other foreign matter.
IRON GATE 17.11 Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S. bars at 200mm apart from bottom flat to top flat and 20mm dia M.S bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete all vertical bars are to be protuded at leat 100 mm above the middile and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2nos (Minimum) strong iron hings of M.S. bars and flat of same size on each leaf to be embededin...................
Construction of storm water drain: 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified.
4.1.1 Providing soling in foundation and under floor with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering works where necessary shall be measured and paid separately. Complete but excluding cost of form work and reinforcement. (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. (b) In proportion 1:4
6.2.4 20mm thick cement plaster in two coats, backing coat 15mm and finishing coat 5mm thick on rough side of single or half brick walls for interior plastering up to 1st floor level including arieses, internal rounded angles, chamfers and /or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3
25.12 Providing precast R.C.C. slab over drain septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S bars @ 150mm center both ways tying with 20gauge black annealed wire with necessary shuttering, curing etc. complete including fixing in position as direction. (a) 100mm thick slab.
Side drain: 19.5 Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls & 100 mm thick C.C (1:3:6) base over one brick flat soiling including 15mm thick cement plastering in prop 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Land Development: 1.4 Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified , including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned) (b) other than Guwahati city
Water Point: 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m below the existing ground level. In ordinari soils
4.1.1 Providing soling in foundation and under floor with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete. a) Brick flat soling
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) a) From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam steel /RINIL (ii) Super Ductile (SD) TMT reinforcement bars
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.5 Flat surface such as soffits of suspendend floors, roofs, landings, cantelever slabs, chajjas, balconies and the like... (a) Floors etc. upto 200mm in thickness. (i) Using 38mm thick plank.
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure up to plinth level including dewatering if necessary (b) In proportion 1:4
2.2.1 Providing and laying plain/reinforced cement concrete work , cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In substructre up to plinth level upto 1st floor level. (ii) Columns, pillars, post, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band beam girder, bressumer, cantilever, staircase including preparing the top surface and finishing of noising. (N) Without using admixture, plasticiser (b) M20 grade concrete or prop 1:1.5:3
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (B) On fair side (b) In cement mortar 1:4
5.7.2.1 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over 15mm thick base of cement mortar in prop 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika /Pedelite /Rouf)/ white cement slurry mixed with approved pigment to match sgade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed....... (b) Executive range Somany/Orient/Nitco/Varmora/VITA/Marbito/Make (i) Of size 800mm X 800mm and above
3.1.2 Supplying fitting and fixing approved PVC Pipes of different sizes with all necessary 'R' brand or similar approved P.V.C. fittings such as bend, tee, elbow, reducer, nipple, plug screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (a) Exposed or in trenches SUPREME/PRINCE/SFMC BRAND or other equivalent (a) 50 mm dia
3.1.2 Supplying fitting and fixing approved PVC Pipes of different sizes with all necessary 'R' brand or similar approved P.V.C. fittings such as bend, tee, elbow, reducer, nipple, plug screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (a) Exposed or in trenches SUPREME/PRINCE/SFMC BRAND or other equivalent. (b) 40 mm dia
3.1.2 Supplying fitting and fixing approved PVC Pipes of different sizes with all necessary 'R' brand or similar approved P.V.C. fittings such as bend, tee, elbow, reducer, nipple, plug screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (a) Exposed or in trenches SUPREME/PRINCE/SFMC BRAND or other equivalent. (c ) 32 mm dia
3.1.2 Supplying fitting and fixing approved PVC Pipes of different sizes with all necessary 'R' brand or similar approved P.V.C. fittings such as bend, tee, elbow, reducer, nipple, plug screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (a) Exposed or in trenches SUPREME/PRINCE/SFMC BRAND or other equivalent. (d ) 25 mm dia
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) I.S.I. make as specified and directed. (a) 50mm dia
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) I.S.I. make as specified and directed. (b) 40mm dia
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) I.S.I. make as specified and directed. (d ) 25mm dia
3.2.1 Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P. pipe will be measured separately) (III) Jaquare make (a) continental/Clarion (i) Standard
3.3.1 Supplying fitting and fixing Stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) (I) Brass stop cock (heavy) of sant make (iii) 25mm dia.
Civil Works: 1.4 Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees, if any monopoly duty etc. (profile measure-ment to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned) (b) other than Guwahati city
CEMENT CONCRETE WORK: 2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
30.2 Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achive the desired density, complete as per Clause 401 of MoRTH specifications ( with an initial lead of 5km) (including cost of testing of materials at site and laboratory as directed as by the deptt.) (b) Using Grading II materials
Land development of football field: 1.4 Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned) (b) other than municipality area:
GAUTAM BRAHMA
Sri Dhajen Wary
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .