Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.9 LAccepted-AOC | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹26.0 L+₹1.1 L (4.22%)Rejected-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹26.2 L+₹1.2 L (4.96%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹29.1 L+₹4.1 L (16.5%)Rejected-Finance | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹29.4 L+₹4.4 L (17.8%)Rejected-Finance | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
16 Dec 2019, 6:00 pmClosed
Lt Col Dinesh Sharma
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
PROVN OF 100 KVA TRANSFORMER ALONGWITH CAPACITOR BANK. TRIVECTOR METER, LT PANEL ALONGWITH ALLIED WORKS AT KISHTWAR AND CERTAIN OTHER SANCTIONED WORKS AT SUIGARH, RAMBAN AND VARIOUS COY LOCATIONS OTHER UNDER GE (I) 873 EWS.
2019_MES_299310_1
NIT-38 of 19-20
Open Tender
Civil Works
Item Wise
180 days
Bhaderwah
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE (I) 873 EWS
₹73,000
Yes
11 Mar 2020
19 Nov 2019
18 Dec 2019
19 Nov 2019
16 Dec 2019
3 Dec 2019
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete all as specified and as directed.
Steel Tubular swaged poles type 410 SP-31 (9.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and as directed.
Pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete all as specified and directed.
Pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volt complete all as specified and directed.
Shackle type insulator porcelain vitereous white, brown or green including galvanised M.S. straps 31 x 5mm size, 75mm x 90mm including galvanised mild steel straps, nut, bolts washers complete for 1100 volts grade insulator complete all as specified and directed.
Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade complete all as specified and directed.
Stay assembly complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part-I using stay rod of 20 mm dia, stay bow 14 mm dia, 400 mm long, MS Plate of size 300 x 300 mm x 6mm thick, stay GI wire 7/4mm dia (loop type insulator stay clamp, excavation and concrete shall be measured and paid separately) complete all as specified and directed.
Loop type insulator, vitreous white, brown or green large size with overall dimension 90 x 140mm with clearance of hole 16mm complete all as specified and directed.
Galvanised steel wire as in Guarding Cradles (hexagonal or rectangular) / Stay strand / contineous earth wire on poles, complete as required at site all as specified and directed.
Air break, gang operated with 15 Nos insulators outdoor type, mechanically operated suitable for horizontal or vertical mounting, fixed type, mounted on insulator and steel frame with operating mechanism worked from ground level, provided with locking arrangement for operating handle, consisting of MS channel, HT post type insulator, contacts of copper alloy, high pressure, heavy duty contact assemble, operating rod of 25mm dia GI pipe medium grade, drop out expulsion assemble of phases fuses etc conforming to IS : 1018 of 1972 with continuous current rating with 15 insulators of current rating upto 400 amps 11000 volts grade, complete all as specified and directed.
Street Light fitting 80W LED LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK-07 with 10KV Built-in Surge Protection Device. complete all as specified and as directed. Make : Havells 'ENDURA PEARL PLUS Cat Part No SL80WLED757 SASYTOPC or equivalent in Crompton / Wipro / Philips / Syska
Pole mounting bracket made out of medium grade GI pipe of 40mm dia, bent to 600 required shape of length 1.5 mtr with two No's of flat iron clamps made out of 40 x 6mm with 12mm dia bolts, nuts & washers duly painted with aluminium paint over a coat of primer complete all as specified and as directed.
Supply, install, test and commissioning Street Light Control Timer Box, Pole mounting outdoor type, made out of 2.0 mm SWG MS sheet of size 450mm x 450mm x 150mm, dust proof, weather proof, vermin proof, aesthetically designed, having at least IP-54 degree of ingress protection, wiring with suitable size multistranded copper cable, cable connections, lugs, etc comprising components as listed hereunder, :- (a) MCB 20 Amps SP 10 KA 240 Volts 'B' Curve - 01 No (b) Power Contactor Three Pole, nominal rating 70A, size FR 2 type ML - 01 No. Make : L&T Cat Part No. SS90701 (c) Digital Timer Switch TP 415 Volt 20 Amps Rating 01 Nos Make : Legrand Cat Part No 649914 Model MaxiRex Time Switch 4QTB (with IP-53 box) Analog type 24 hours time switch, 500 hours working reserve posible
Sub main wiring with two single core PVC insulated multistranded un-sheathed FR PVC cable of size 2.5 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including conduit and accessories) with continuous PVC insulated multistranded unsheathed FR PVC cable earth wire of 1.5 Sqmm dia for connecting Street Light fitting to DB complete, complete all as specified and directed. Note : Two run of 2.5 sqmm wire, one run of 1.5 sqmm wire and one run of PVC conduit shall be considered as one unit length.
Supply, installation, testing and comissioning of tamper proof electronic microprocessor based energy meter suitable for 3 phase 4 wire 415 Volts (Three Phase x 240 Volts), 50Hz, AC supply system, CT operated, -/5A, with class 0.5s accuracy as per IS 14697, IEC 62052-11, IEC 62053-22, IS 15959, having LCD display, made of engineering plastic double-insulated glass-filled polycarbonate FR grade with self extinguishing properties, AMR compatible, having optical port and provision of modem for data communication, all as specified and as directed. Make : L&T / HPL / HAVELLS / SECURE / AE / LEGRAND
Supply, installation, testing and comissioning of tamper proof electronic microprocessor based static energy meter suitable for Single phase 240 Volts, 50Hz, AC supply system, with backlit LCD display of rating 10-60 Amps, made of engineering plastic double-insulated glass-filled polycarbonate FR grade with self extinguishing properties, AMR compatible, having optical port and provision of modem for data communication, all as specified and as directed. Make : L&T / HPL / HAVELLS / SECURE / AE / LEGRAND
Supply installation, testing and commissioning of 11 KVA (HT) Trivector Meter complete with required wiring system from metre to CT & PT, complete all as specified and directed. Make : L & T Model No. ER-300P class 0.5 (Base mounting), Three Phase, 4W TVN 110 Volt (L-L) 1A class 0.5S BM (WR300BB 1200) or equivalent in Siemens /ABB / Legrand
Sheet metal enclosure factory made single door for DB 240 volts without bus SPN 1 Way, complete all as specified and as directed.
MCB TPN 63 Amp 10 KA 415 Volts, complete all as specified and as directed.
Lightening arrester expulsion type consisting of multiple spark gaps n series with one or more non linear resister to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed directed to sun with ambient temperature below -10º C to 50º C suitable for surge discharge capacity 65 KA, 11000 volts grade conforming to IS-4350 including all fittings, complete all as specified and directed.
Supplying, installing, designing, testing and commissioning of LT outdoor type Panel Board, Factory made, (Cubical kiosk type), weather, dust and vermin proof, CPRI approved with locking arrangement made out of MS sheet 3.15 mm thick with suitable size of channel for base complete with copper bus of 400 Amps rated of size 32 x 5mm with cable gland of suitable size and in adequate nos, cabinet for housing mounting switch, disconnection fuse unit, metering equipments, prewired with suitable size of copper conductor and duly powder coated mounted on PCC platform of PCC 1:2:4 type B1 using 20mm graded aggregate on angle iron frame which is made out of 40 x 40 x 6mm thick angle iron duly marked the incoming outgoing controls, complete all as specified, directed and comprising of the following :-
(A) Incoming (i) MCCB 250 Amps, breaking capacity 35 KA, FP, 415 Volts (adjustable thermal and magnetic release) – 01 No (B) Outgoing (i) MCCB 100 Amps, breaking capacity 16 KA, 4 Pole 415 Volts (adjustable thermal and magnetic release) – 02 Nos (ii) MCCB 63 Amps, breaking capacity 16 KA, 4 pole, 415Volts (adjustable thermal and magnetic release) – 02 Nos (c) On-load change over switch with advance neutral open execution, Four Pole, 415V, 50Hz, AC, fixed inside the panel 250 Amp capacity – 01 (d) Three Phase Multifunctional Digital Meter consisting of Ammeter, Voltmeter, Frequency Meter, PF alongwith suitable CTs – 01 No (e) Complete control Panel wiring with 1.5 sqmm stranded copper conductor alongwith one set of indicator lamp for RYB for incoming and outgoing feeders (f) Lock pedestal – 01 No
Supply, installing, designing, testing and commissioning of LT outdoor type Feeder Pillar Box, factory fabricated cubical kisok type, weather dust and vermin proof with IP-65 protection, CPRI approved with locking arrangement, made out of MS sheet 3.15 mm thick with suitable size of channel for base complete with 200 Amps rated copper bus bar chamber with cable gland of suitable size andin adequate nos, cabinet for housing mounting switch, disconnection fuse unit, meteringequipments, prewired with suitable size of copper conductor and duly powder coated mounted on PCC platform of PCC 1:2:4 type B-1 using 40mm graded aggregate on angle iron frame which is made out of 50 x 50 x 6 mm thick angle iron duly marked the incoming outgoing controls, complete all as specified and directed and comprising of the following :-
Incoming : (a) MCCB 160 Amps, breaking capacity 25 KA, FP, 415V (adjustable thermal and magnetic release) - 01 No (b) Bus bar chamber comprising 04 Nos copper strip bus bars PVC insulated made of copper strip size (32 x 5) mm, PVC sheathed with colour coding. Outgoing : (a) MCCB having current rating 63Amps with rupturing capacity 25 KA, AC 415 volts FP (adjustable thermal and magnetic release) - 04 Nos (c) MCB TPN 63 Amps - 02 Nos (d) MCB SPN 32 Amps - 02 Nos (e) Lock Pedastal (f) All accessories pre-wired with suitable size PVC insulated copper conductor cables for controll wiring and PVC insulated copper strip of appropriate size for power circuit as per stnandard Engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation
Supply, installing, designing, testing and commissioning of LT outdoor type Feeder Pillar Box, factory fabricated cubical kisok type, weather dust and vermin proof with IP-65 protection, CPRI approved with locking arrangement, made out of MS sheet 3.15 mm thick with suitable size of channel for base complete with 200 Amps rated copper bus bar chamber with cable gland of suitable size andin adequate nos, cabinet for housing mounting switch, disconnection fuse unit, meteringequipments, prewired with suitable size of copper conductor and duly powder coated mounted on PCC platform of PCC 1:2:4 type B-1 using 40mm graded aggregate on angle iron frame which is made out of 50 x 50 x 6 mm thick angle iron duly marked the incoming outgoing controls, complete all as specified and directed and comprising of the following :-
Incoming : (a) MCCB 200 Amps, breaking capacity 25 KA, FP, 415V (adjustable thermal and magnetic release) - 01 No (b) Bus bar chamber comprising 04 Nos copper strip bus bars PVC insulated made of copper strip size (32 x 5) mm, PVC sheathed with colour coding. Outgoing : (a) MCCB having current rating 100Amps with rupturing capacity 25 KA, AC 415 volts FP with thermal magnetic release - 02 Nos (b) MCCB having current rating 63Amps with rupturing capacity 25 KA, AC 415 volts FP (adjustable thermal and magnetic release) - 02 Nos (c) MCB TPN 63 Amps - 02 Nos (d) MCB SPN 32 Amps - 02 Nos (e) Lock Pedastal (f) All accessories pre-wired with suitable size PVC insulated copper conductor cables for controll wiring and PVC insulated copper strip of appropriate size for power circuit as per stnandard Engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation
Supply, installation, Commissiong and Testing Automatic power factor correction Panel Board, out door type, factory made, cubical kiosk type, weather, dust and vermin proof, CPRI approved with locking arrangement, made out of CRCA sheet of 3.15mm thick with suitable size of channel for base complete with capacitor banks of capacity 90 KVAR reverse power relay 3 phase with tuned reactor for 250KVA transformer out door type suitable for 1100 Volt 3 phase 50 Hz AC supply floor mounted, connected with suitable size thimbles / lugs, PVC insulated multi-stranded copper wire of suitable size with PVC flexible conduit medium quality as required, comprising of copper bus bar 200Amps capacity fixed on insulators to achieved power factor 0.95 and duly powder coated in siemens grey colour mounted on PCC platform of PCC 1:2:4 type B-1 using 20mm graded aggregate on angle iron frame made of 50 x 50 x 6mm thick angle iron duly marked with incoming and outgoing controls, completed all as specified and as directed comprising of the following :-
Supply, installation, Commissiong and Testing Automatic Power Factor Correction Panel Board, out door type, factory made, cubical kiosk type, weather, dust and vermin proof, CPRI approved with locking arrangement, made out of CRCA sheet of 3.15mm thick with suitable size of channel for base complete with capacitor banks of capacity 30 KVAR reverse power relay 3 phase with tuned reactor for 100 / 63 KVA transformer out door type suitable for 1100 Volt 3 phase 50 Hz AC supply floor mounted, connected with suitable size thimbles / lugs, PVC insulated multi-stranded copper wire of suitable size with PVC flexible conduit medium quality as required, comprising of copper bus bar 200Amps capacity fixed on insulators to achieved power factor 0.95 and duly powder coated in siemens grey colour mounted on PCC platform of PCC 1:2:4 type B-1on angle iron frame made of 50 x 50 x 6mm thick angle iron duly marked with incoming and outgoing controls, completed all as specified and as directed comprising of the following :-
Notes for Serial Item No 30 to 34 : 1. The drawing for APFC Panel / LT Feeder Pillar Box shall be got approved by the Engineer-in-Charge. 2. The Pre-dispatch inspection of APFC Panel / LT Feeder Pillar Box shall be done by the Rep of the Accepting Officer at factory site. 3. All the existing cables shall be fixed with glands, lugs etc. of the requisite size. Makes for Serial Item No 30 to 34 : Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear Make of MCCB & Star Delta Starter : L&T / Legrand / Schneider / Havells Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO Contactor : SECURE / L&T / ABB / SCHENEIDER / SEIMENS / LEGRAND / AE
Supply, installation, testing and commissioning of capacity 100 KVA Transformer, step-down, 11/0.433 KVA complete, outdoor type, copper wound with transformer oil of dieletric strength-45KV including tapping up and down, installing with proper connection of HT/LT side, earthing of capacity 63 KV, Three Phase, Four Wire, 50 Hz, oil immersed naturally cooled, Delta connected on primary (HV) side and star connected (LV) side, having tapping 0%, 2.5%. 5% and 7.5% on HV to be charged by means of hand operated Off Load tap changing gear including first filling of oil and all standard fitting such as breather unit, drain out valve. conservator tank and mounting, complete all as specified in IS-2026 and as directed. Make : Alstom (Areva) / Seimens / ABB / JK Transformer / Bharat Bijlee / Voltamp / Schneider
Material and labour for construction of Platform suitable for 100 KVA transformer of size 2.80m x 2.80m with 1.20m clear height from ground level, 1.00m deep foundation, 150 mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation below ground level, 23cm wide brick masonry in CM 1:6 below & above ground level, hollow space to be filled hard core of size not exceeding 63 mm, deposited spread and levelled in layers not exceeding 15cm thickness, watered and well rammed with 100mm thick cement concreate 1:2:4 type B-2 as in Floor/Top of platform, brick surfaces plastered in CM 1:4 including protection with XPM, gate and chain link fencing rail around the platform with angel iron of 40 x 40 x 6mm frame upto 1.20m clear height supports grouted in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in foundation of angle iron including excavation in any type of soil, returning filling in and removal of surplus soil to a distance 50m, complete all as specified and directed
Supply, installation, testing and commissioning of oil cooled CT/PT metering unit with accuracy class of 0.5 rated system of 11 KV, 50 Hz including potential transformer outdoor type three phase (R,Y, B) suitable for 11 KV, PT ration 11/0.11 PT burden 50 VA complete and current transformer outdoor type oil cooled, three phase (R,Y,B) suitable for 11 KV supply system with CT Ration 10/5A, burden 15VA complete with initial filling of oil including all fixing accessories such as clamps, nuts bolts and channel required at site, complete all as specified and directed. Make : Everest/ L & T
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 95 Sqmm 3 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 95 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core, complete all as specified and as directed.
Cable Jointing Kit for HT 11 KV (Earthed) grade cable for outdoor termination hear shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including testing and commissioning, complete all as specified and directed
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 25 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 40 x 3 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
M/S BALI CONSTRUCTIONS
VARDHMAN INTERNATIONAL
M/S Builders Indias
darshan kumar gandhi
Bidder Name
M/S BALI CONSTRUCTIONS
SWASTIK TRADERS
VARDHMAN INTERNATIONAL
M/S Builders Indias
darshan kumar gandhi
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .