| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.9 L+₹36,790 (1.44%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹27.7 L+₹2.3 L (8.83%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹28.0 L+₹2.5 L (9.98%)Rejected-Finance 11 71 KAVERI PATH MANSAROVAR JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹28.6 L+₹3.1 L (12.3%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
2 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE HISAR
GE HISAR
CA NO GE(H)-80/2023-24 WELCOME MAINT TO OFFRS MD ACCN UNDER AGE B/R-II OF GE HISAR AT HISAR MIL STN
2024_MES_644981_1
CA NO GE(H)-80/2023-24
Open Tender
Civil Works
Item Rate
210 days
HISAR
AS PER NIT
6 documents required · 6 mandatory
₹500
GE HISAR
₹70,000
Yes
20 May 2024
4 Mar 2024
4 Apr 2024
4 Mar 2024
2 Apr 2024
19 Mar 2024
Amount
M & L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement including mixed with and including liquid water proofing compound @200 ML per 50 KG by weight of cement including Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement including mixed with and including liquid water proofing compound @200 ML per 50 KG by weight of cement including Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Supply only integral liquid water proofing compound (ISI marked).
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer and applying 2mm thick wall care putty all as specified & as directed
Material and labour preparation of newly plastered/asbestos cement surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for complete removal of existing treatment on walls (any numbers of layers) by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc and including filling cracks or holes with white cement putty and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of 1mm thick wall care putty all as specified & as directed.
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of white wash complete all as specified & as directed.
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of oil emulsion distemper (OBD) of approved shade/tint including filling of crack and small hole with wall care putty all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L preparation of old plastered / concrete surfaces / Kerb stone of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of old painted surfaces of wood and wood based material any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed.
Material and labour 75 mm thick PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in plinth protection, surface finished fair and even without using extra cement complete all as specified.
M&L for factory made 60mm thick machine pressed precast cement concrete coloured interlocking paver blocks glossy finish of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & directed
M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. complete, all as directed.
Taking down chowkat or frame with shutters area not exc. 1.5 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts complete all as specified
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) including shutters with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc, Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws including powder coated 'D' type handle of suitable size, tower bolt of suitable size, suitable size hinges heavy grade complete all as specified & as directed. Note :- Mortice lock, Door closer & Glass panes / ACP sheet shall be measured & paid seperately under relevant item of BoQ.
Supply & fixing butt hinges of size 100mm medium weight, cold rolled mild steel ISI marked complete all as specified.
S&F 100mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified.
S&F extruded aluminium alloy handle, 150mm size, fabricated type, anodized (ISI marked) complete all as specified.
S&F in repairs 20mm bore mild steel CP curtain rod with 02 Nos decorative ball type brackets (for each opening) and 02 Nos decorative side stoppers (for each opening) fixed on wall with wooden gutties & screws complete all as specified & as directed.
M&L for 18-20mm thick Granite (of any type) tiles machine cut, as in steps, jambs, cooking plateforms and the like, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over & including 20mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area, complete, all as directed.
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified.
M&L for brick work using old size fly ash bricks as specified in clasue 6 of Particular specification, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
M&L precast cement concrete (1:2:4 type B0 using 12.5mm graded stone aggregate) louvers and jallies, 25mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:4 all as specified & as directed
M & L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified.
Material and labour preparation of newly plastered surface of walls & applying three coats of white wash complete all as specified.
S&F hasp and staple of size 100mm aluminium anodized safety type with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises
M&L for non skid ceramic jointless tiles (coloured) 1st quality, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for vitrified ceramic tiles , 8-10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic designer & pattern (dark & light shade) jointfree tiles (coloured) premium quality, 450mm x 300mm x 7mm thick, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
Supply and fixing in repairs Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.specified.
S&F in repairs/replacement 3mm thick acrylic transparent sheet, in square/rectangular not exc 0.5 sqm in each pane fixed / lock with window frame by using PVC snap beading with necessary self tapping reviting / screwing and suitable method with and including hacking out old broken glass (any thickness, size, quality or description) from any type of window / door glazed with putty or fixed with beads complete all as specified and directed.
S&F in repairs 40mm dia brass polished cupboard knobs fixed with nut, screws and washer complete all as specified and as directed.
Dismantling wooden boarding, any description, fixed in any position with nails all as directed.
S&F decorative 18mm thick factory made Kitchen cabinet and Almirah 100% soild rigid PVC (Poly Vinyl Chloride) foam sheet prelam colour having density of 600 Kg/Cum, manufactuered by an ISO 9001-2015 Certified Company, Termite proof, water proof and flame retardant PVC sheet, manufactured by single layer extrusion process, for one side laminated solid PVC foam sheet PVC film laminate should be pasted on PVC sheet, with suitable Continious hinge, 100mm long decorative SS handle, magnet for receiving door shutter, adhesive and of approved shade, manufacturer embossing, bar code and hologram on door, test certificate and autghorized letter complete all as specified and directed.
S&F 5mm thick hollow PVC wall lining, single side prelaminated with flat or fancy patterned on laminated side, PVC sheet inclusive of fixing with screws or with solvent cement required at site on walls including necessary corner angles, filltes etc required at site complete all as specified and directed.
S&F in repairs Bib taps,cast copper alloy with crutch or butterfly handle, chromium plated, fancy type , screwed for iron pipe or for brass ferrule, for 15 mm bore GI pipe complete all as specified and directed.
S&F in repairs 20 mm bore steel water GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as required complete and fixed with or without concealed to walls, ceilings or laid in floors complete all as specified and directed
S&F in repairs 15mm bore, fancy type brass CP Hand Shower (Health Faucet) (ABS Body) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet (Padestal pattern) White, with 'P' or 'S' trap including plastic water closet seat cover, black, closed pattern with flat bottom with mild steel chromium plated or aluminium hinging device and fixing with all joints including connection to drain or outgoing pipe and to flushing pipe, anti-syphonage pipe etc complete all as specified and as directed.
S&F PVC (SWR) floor trap 75mm dia, plain with grating including joining to waste pipe, all as specified and directed
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls with necessary clamps/ laid in floor complete all as specified.
S&F 75mm bore PVC (SWR) bend with access door all as specified & as directed.
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed.
M&L for treatment of sunken floor slab compraises of the following specifications including demolition of floor and all as specified :-(i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical surfaces upto finished floor level) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely and providing 40mm thick avgerage PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for providing spout 50mm bore GI pipe medium grade of length 0.50m and fixed all as specified. (ii) M&L for providing rendering of uneven surfaces of vertical sunken with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. (iii) M&L for applying two coats of polymer modified cementious water proof coating (Sika / Fosroc / STP / Asian Paint )as per manufacturers instruction to bottom and vertical sides up to finished floor level and 100mm aove FFL , the thickness of two layer shall be 1mm and when the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (iv) M&L for providing plaster to the bottom and sides up to FFL with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spou Note :-(i) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iii) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (iii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint and cost is deemed shall be included in quoted rates. (iv) Cost of WPC shall deemed to be included in quoted rates. (v) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage to the entire satisfaction of GE. Test shall be done in presence of reps of Engineer-in-charge and record for each sunken slab shall be maintained. (vi) The treatment shall be carried out in presence of Engineer-in-charge and tested. Cost of testing is inclued in the rates quoted above. (vii) For Payment purpose, the Plan area of Sunken floor shall be taken into account.
M/L for Cutting of hole in exhusting wall for opning for exhaust fan and making good to facings where required and pointing in cement mortar 1:3 to ends or edges complet all as specified and directed by Engineer in charge.
Supply and fix in repair capacitor 2.5 mfd to 3.15 mfd dry type with PVC clamp for Ceiling fan make of capacitor : Epcos/Unistar/Usha/jyoti/supreme/Tibcon/Havells complete all as specified and directed.
Supply and fix in repair of rubber bush complete with nut bolt, fork hook and spilt pin, washer suitable for existing ceiling fan 1200mm/1400mm sweep.
Supply and fix in replacement Ceiling fan stator 48 inch sweep 12 mm copper winding including thick steel bolt with double nuts and locking pins and high quality rubber bushing to reduce vibration complete all as specified and directed by Engg-in-charge.
Supply and fix in replacement rotor complete with copper winding suitable for 48 inch sweep ceiling fan all as specified and directed by Engg-in-charge
Supply & Fix ceiling fan mild steel body set (upper & lower) for ceiling fans of any sweep and make and fixing in position complete.
Supply and fix in repair PVC canopy set (upper & lower) for ceiling fans of any sweep and make and fixing in position complete.
Supply and fix in repair of aluminium blades of ceiling fan for 1200mm / 1400mm sweep & make complete.
Supply and fix in repair MS heavy duty down rod of 15mm dia and 600mm length with necessary cutting / drilling holes and painting for ceiling fans complete all as specified and directed.
S&F in replacement Wall mounting Fan 400 mm sweep, 230 volts, fixed on wall with suitable size nut, bolts and washers complete all as specified and directed. Make: Crompton/Havells/Bajaj
Supply and fix in repair gun metal shaft for ceiling fan of any sweep and fixing in position for smooth functioning of ceiling fan complete all as specified and directed.
S&F in replacement PVC air fresh air Fan 200 mm sweep, 230 volts, fixed on wall with suitable size nut, bolts and washers and connection complete all as specified & directed.
Supply & Fixing in replacement ceiling Fan 1200mm sweep 210 cfm Decoreted type with down rod , canopy, rubber reel etc including provision of three single core 0.5 sqmm copper conductor flexible cable connected from ceiling rose to fan and suitable size MS bolts, nuts for fixing ceiling fan complete all as specified and directed.
Supply and fix in repair in replacement PVC flexible 2 core cable with copper con-ductor of size 23/0.76 mm from ceiling rose to fan including connection complete.-
Supply and fix in repair in replacement of louvers iron with shutters suitable for existing exhaust fan of any size and shape at site complete all as specified and directed by Engg-in-charge
S&F in replacement of rigid non metallic PVC conduit 20mm complete with clamps and nuts bore all as specified and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
All as per item No 65.00 (here-in-before) but excluding existing concealed conduit.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including cutting chases in walls and including concealed PVC non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed modular steel box covered with white modular cover plate and frame for housing switches, sockets, fan regulators etc complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No 67.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 67.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 67.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per item No. 67.00 (here-in-before) but for one 5 amps socket outlet independent but below the switch board of light points in the same vertical or horizontal plane
All as per serial item No. 67.00 (here-in-before) but for one bell/buzzer point controlled by one bell push
All as per serial item No. 67.00 (here-in-before) but for One Light point controlled by two, two way switches with cables 1.5sqm size.
All as per srl item No. 67.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring for one light controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing rigid PVC coduit and conduit accessories in existing concealed type in walls/ceilings and including change of sunk type modular pressed steel box covered with modular cover plate and frame for housing switch, socket , fan regulators etc for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed by Engineer-in-charge. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' )
All as per item No 75.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 75.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 75.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per item No. 78.00 (here-in-before) but for one 5 amps socket outlet independent but below the switch board of light points in the same vertical or horizontal plane
All as per item No. 75.00 (here-in-before) but for one bell/buzzer point controlled by one push button on the same board with other switches or independent.
All as per serial item No. 75.00 (here-in-before) but for One Light point controlled by two, two way switches.
All as per srl item No. 75.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs modular type switch 1 way 6Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 1 way 16Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 2 way 6amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type bell push , 5 Amp 240 Volts.
Supply and fixing in repairs modular type socket 6Amp - 3/5 pin combined 2 modle 230 volts AC complete all as specified and directed
Supply and fixing in repairs modular type socket 6Amp/16 Amp - 3/6 pin combined 2 modle 230 volts AC complete all as specified and directed
S&F modular type Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed
S&F modular ceiling rose surface plastic 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
Supply and fix modular lamp holder, insluated body, with modular straight back plate suitable for batten fittings & complete all as specified & directed
Supply and fixing in repair switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply and fixing in repair switch piano flush type, single pole, one way, 15 Amp, 230 Volts.Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply and fixing in repair flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply and fixing in repair flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply and fixing in repair lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed
Supply and fixing in repair ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
Supply and fixing in repair Ceiling fan regulator electronic four step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed. Make : Genric/Schneider/L&T/Legrand/Havells
Supply and fixing in repair bell push flush type, 5 Amp 240 Volts. Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply and fixing in repair Bell ding dong type, AC, 230 Volts, single pole.
S&F in replacement sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Legrand / L&T / Havells / C&S/IndoAsian/HPL. Note:Cost of thimbles for connecting cable to MCCBs/MCB and making good disturbed surface is included in this item and nothing will be paid extra on this account.
S&F in replacement sheet metal enclosure distribution board SP&N, 12 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Legrand / L&T / Havells / C&S/IndoAsian/HPL. Note:Cost of thimbles for connecting cable to MCCBs/MCB and making good disturbed surface is included in this item and nothing will be paid extra on this account.
S & F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, IS-8828 marked for fixing in DB complete all as specified & directed. . Note :-Make of MCB shall be same of that DB
S & F MCB SPN, 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S&F MCB TPN, 63 Amps 415 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in repair Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- (i)Two lengths of 4 Sqmm cable, one length of 4 Sqmm cable and one length of PVC conduit will be measured as one length. (ii) Cost of taking down existing submain wiring including all accessories is included in this item and nothing will be paid extra on this account
All as per item No 106.00 (here-in-before) but cable drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
Supply and fix in repair round blank PVC ceiling outlet wall plate covers for 4 inch dia electrical box with necessary plastic clamp and screws complete all as specified and directed by Engg-in-charge.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 3 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 4 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 6 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed. Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 8module deep sunk in wall including making good distrubed surfaces complete all as specified and directed. Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
Supply and fixing in repairs modular type switch 1 way 6Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 1 way 16Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 2 way 6amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type bell push , 5 Amp 240 Volts
Supply and fixing in repairs modular type socket 6Amp - 2/3 pin combined 2 modle 230 volts AC complete all as specified and directed
Supply and fixing in repairs modular type socket 6Amp/16 Amp - 2/3 pin combined 2 modle 230 volts AC complete all as specified and directed
Supply and fix modular lamp holder, insluated body, with modular straight back plate suitable for batten fittings & complete all as specified & directed
S&F modular type Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down existing u/s earthing all as specified & as directed. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
Supply and fixing LED lights fitting 1x 40W, 220V,AC wall mounted LED batten with aluminium extruded polycarbonate housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED lights fitting 1x 10W, 220V,AC wall mounted LED batten with aluminium extruded polycarbonate housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder, Aluminium housing connecting up with three core flexible copper conductor cable of suitable size. Make:Surya/Havells/Jaquar/Crompton
S&F sheet metal enclosure Single pole and neutral with a two pin and earth plug and socket complete with and including one 20 Amp SPN MCB 'C' curve complete all as specified. Make :- Legrand / L&T / Havells / C&S/indoasian/anchor
Supply and fixing in repairs decorative wall light, stainless steel rust free fixture with white glass diffuser including 20 watt capacity minimum LED filament lamp complete all as specified and directed. Make : Havells Voila wall Light or equivalent of makes
Supply and fixing in repairs round / square surface mounting 12watt minimum capacity LED panel in PDC housing and high translucent frosted plastic diffuser with 100lm/ w efficiency complete all as specified and directed. Make : Havells - EDGESURFACERDDLR12WLED 8575 & Crompton - LC DSP LN-R12CDL & WIPRO LDD6151XXX-57MG1/Jaquar LNRO02R012SC/Surya ATHENA SLE DLS 12WXXRD or equivalent of makes
Supply only metal clad plug Socket 20 Amp (enclosure type) suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.Make:-Havells/HPL/Benlo
Supply only metal clad plug top 20A (enclosure type) suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.Make:-Havells/HPL/Benlo
S&F sheet metal enclosure distribution board VTP&N, 4 way, double door, powder coated, protection class IP-43, suitable for mounting MCCB up to capacity 125 Amps, DBs conforming to IS-13032, IS-8632, BS-5484 with min 200 Amps rating copper bus bar and isolator neutral bar, complete all as specified and directed.
S&F MCCB TPN, 63 Amps 415 Volts, Type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed by Engineer-in-Charge. Note: Make of MCCB shall be same of the DB
S&F in repair sub main wiring with two single core cable PVC insulated unsheathed of copper multi standard conductor FRLS cable of size 6 sqmm, 1100 volts grade drawing through and including concelaed conduit 25mm dia medium duty including acessories such as Tee, bend, flbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistandard FRLS copper cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in Cm (1:3) and finishing the surface to match with exisitng surface etc complete all as specified and directed by Engineer-in-Charge including taking down old unserviceable submain wiring. Note. (i) Two lengths of 6 sqmm cable, one length of 6 sqmm cable and one length of PVC conduit will be measured as one length. (ii) cost of taking down exisitng submain wiring including all accessories is included in this ttem and nothing will be paid extra on this account.
All as per item 132.00 above (here-in-before) but cable drawn through existing surface.concealed conduit including taking down existing unserviceable sub main wiring.
Supply & fix dummy modular type blank plate for modular switches all as specified and directed by Engineer-in-Charge.
S&F in repair modular metal flush box alongwith modular white cover plate frame for mounting switch, sockets, fan regulator etc of 2 module deep sunk in wall including making good disturbed surfaces complete all as sepcified and directed. Note: The cost of cutting chasing of wall, if required and making good disturbed surface in Cm (1:3) and finishing the surface to match existing surface, etc complete all as specified and directed by Engineer-in-Charge including down old unserviceable box is included in this item and nothing will be paid extra on this account.
moti construction company
M/s Rao Constructions, 1173 Urban Estate-II, Hisar
Balaji Construction Co.
NAVIN KUMAR
SHRI HARI BUILDERS
M/S RR ENGINEERING CO
malik constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .