Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-Finance | ₹15.4 L | L1 | Accepted-Finance L1 Accepted |
| 2 | L2₹15.6 L+₹13,077.63 (0.85%)Rejected-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | ₹15.6 L+₹13,077.63 (0.85%) | L2 | Rejected-Finance L2 Rejected |
| 3 | L3₹15.8 L+₹32,804.89 (2.13%)Rejected-Finance N A | ₹15.8 L+₹32,804.89 (2.13%) | L3 | Rejected-Finance L3 Rejected |
| 4 | L4₹15.9 L+₹48,764.02 (3.16%)Rejected-Finance F 1 1ST FLOOR EAST JYOTI NAGAR SHAHDARA DELHI DELHI 110093 | NORTH EAST | DELHI | 110093 | ₹15.9 L+₹48,764.02 (3.16%) | L4 | Rejected-Finance L4 Rejected |
| 5 | L5₹16.0 L+₹55,635.31 (3.60%)Rejected-Finance 0 0 0 ABABAKPUR KANPUR NAGAR UTTAR PRADESH 209203 UDYAM UP 43 0068644 | KANPUR NAGAR | UTTAR PRADESH | 209203 | ₹16.0 L+₹55,635.31 (3.60%) | L5 | Rejected-Finance L5 Rejected |
Tender Value
₹22.2 L
EMD Value
₹44,331
Closing Date
25 Aug 2026, 1:00 pmClosed
Executive Engineer (Elect)-II
OFFICE OF THE Ex. ENGINEER (ELECT)-II, SHAHDARA (N) ZONE, KeshavChowk, Delhi-110053
Provision of lighting arrangement with street light poles in MPL Park Genral DDA flates (mandir) Ashok Vatika, Satsang park,Mother dairy, shri ram park,Ahinsha park,RPS park gate 1 and 2 genral DDA flates Gate 1 and 2, 66 RPS,34 RPS, Mahila Park in w
2026_MCD_287862_1
EE(E)-II/SNZ/MCD/26-27/TC-10/2
Open Tender
Electrical Works
Percentage
90 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹44,331
3 Sept 2026
17 Aug 2026
25 Aug 2026
17 Aug 2026
25 Aug 2026
17 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. | 24 | Each | 5,958 | ₹1,42,992 |
| 2 | Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. | 1,200 | Meter | 50 | ₹60,000 |
| 3 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/ METAL pipe as required. Up to 35 sq.mm. | 1,050 | Meter | 47 | ₹49,350 |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sq.mm. | 150 | Meter | 36 | ₹5,400 |
| 5 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres lengthalong the pole for protection of under ground cable as required. | 4 | Each | 2,783 | ₹11,132 |
| 6 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal) | 1,050 | Meter | 289 | ₹3,03,450 |
| 7 | Fabrication, supply & erection of 5.0 mtr height, minimum 3 mm thick, bottom dia of 130mm & top die of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. Uc supplying and fitting of 6 mm thick laminated mounted sheet inside the window and I/c providing and welding 3 nos. Gl strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor 4 nos. & shorting links on DIN channel Uc providing and fixing DIN channel of suitable length, 6 Amp. SPMCB 'C' Curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Riveted plate on the pole. Galvanization as per relevant lS code etc es required | 64 | Each | 9,229 | ₹5,90,656 |
| 8 | Supply of XLPE insulated and PVC Sheathed Al conductor armoured cable 1.1KV grade confirming to IS-7098.
a) 2Cx10 sqmm. | 1,200 | Meter | 116 | ₹1,39,200 |
| 9 | Supply of PVC insulated and FR PVC Sheathed multicore copper conductor 1.1KV grade, conforming to grade IS 694 as required . 3*1.5 Sq.mm | 634 | Meter | 104 | ₹65,936 |
| 10 | LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66, IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 50 watt | 126 | Each | 1,782 | ₹2,24,532 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
circular.pdf
Tender Documents • 9.28 MB
GCC2024.pdf
Tender Documents • 9.36 MB
Conditions.pdf
Tender Documents • 0.11 MB
BOQ_335819.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .