| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹20.5 L+₹1.3 L (6.73%)Rejected-Finance | L2 | Rejected-Finance Not Lowest. | |
| 3 | L3₹20.5 L+₹1.3 L (6.97%)Rejected-Finance | L3 | Rejected-Finance Not Lowest. | |
| 4 | L4₹21.0 L+₹1.9 L (9.66%)Rejected-Finance | L4 | Rejected-Finance Not Lowest. | |
| 5 | M/S J.A CHAWHAN L5₹24.8 L+₹5.6 L (29.3%)Rejected-Finance | L5 | Rejected-Finance Not Lowest. |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
23 Sept 2021, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Kamptee Cantt - 441 001
REPAIR, CLEANING AND MAINT OF SEWAGE LINE, SEPTIC TANK, SOAK PITS AND SANITARY FITTINGS, PLUMBING WORKS AND REPAIR TO OTHER RELATED WORKS IN AREA-I UNDER GE KAMPTEE
2021_MES_463657_2
8309/E8
Open Tender
Civil Works
Item Rate
270 days
Kamptee
Class E, Cat a (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹40,000
Yes
23 Oct 2021
3 Sept 2021
25 Sept 2021
3 Sept 2021
23 Sept 2021
11 Sept 2021
Amount
Demolition of brickwork built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work with fly ash bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4) complete all as specified and directed.
Blocking up the inlet of septic tank for 1000 users and pumping out effluent dirty liquid and sludge from sludge chambers / septic tank including settling tank and intercepting chamber etc up to bottom and collecting sludge and dirty liquid in to closed container and cleaning the septic tank with fresh water. Afterwards opening the inlet of septic tank for re-use and lifting the sludge to out side MD land complete all as specified and directed. (The rates quoted are deemed to be inclusive of transport required.)
All as per item No 3 above but septic tank for 500 users complete all as specified and directed.
All as per item No 3 above but septic tank for 200 users complete all as specified and directed.
All as per item No 3 above but septic tank for 100 users complete all as specified and directed.
All as per item No 3 above but septic tank for 50 users complete all as specified and directed.
All as per item No 3 above but septic tank for 25 users complete all as specified and directed.
All as per item No 3 above but septic tank for 05 users complete all as specified and directed.
Blocking up the inlet of soakage well for 2000 users and removing of bricks bat out effluent dirty sludge from soakage well including settling tank and intercepting chamber etc up to bottom and collecting sludge and bricks bat in to closed container and cleaning the soakage well with fresh water. Afterwards opening the inlet of septic tank for re-use and lifting the sludge to out side MD land complete all as specified and directed. (The rates quoted are deemed to be inclusive of transport required) Note:- Re filling of brick bats in Soakage well to be measured separately.
All as per item No 10 above but soakage well for 1000 users complete all as specified and directed.
All as per item No 10 above but soakage well for 500 users complete all as specified and directed.
Taking out sludge including removing blockage and cleaning the sewage line by using bamboos sticks, MS rod or other sticks and revolving the rope inside the sewer between the two man holes for 150 mm dia of sewar and cleaning the same by fresh water complete all as specified and directed.
All as per item No 13 above but 200 mm dia complete all as specified and directed.
Taking out sludge including blockage and cleaning of the MH of any size, description, depth not exc 1.50m each and collecting the sludge in closed container and cleaning the man holes with fresh water and re-openning of manholes complete all as specified and directed. Note:- Sludge be lifted and taken to out sides of MoD land as directed by Engr-in-Charge and be inclusive of transport.
All as per item No 15 above but depth exc 1.50m and not exc 3.00m each complete all as specified and directed.
Cleaning of WC/ GT/ NT and similar kind of blockage including all tools required and making smooth flow of waste water complete all as specified and directed.
S&F in repair perforated PVC (SWR) pipes 150mm dia single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L for loose filling with broken bricks/ brick bats of gauge 40 to 80mm as in soakage pits, soakage well, sockage PVC pipes in trenches etc complete all as specified and directed.
Excavation in trenches not exc 1.5m deep and not exc 1.5m wide in soft/loose soil etc complete all as specified and directed.
All as per item No 20 above but depth exceeding 1.5m and not exc 3.0 m depth complete all as specified and directed.
Excavation over areas not exc 1.50m deep and getting out in soft/loose soil complete all as specified and directed.
All as per item No 22 above but exc. 1.5m depth and not exc 3m depth complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil complete all as specified and directed.
Removing excavated material (soil) not exc 50m and deposited where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required for 150mm internal dia of pipe complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required for 200mm internal dia of pipe complete all as specified and directed.
Demolition and breaking up of 150mm dia drain pipes (salt glazed ware, AC or RCC Pipes) set in cement mortar complete all as specified and directed.
All as per item No 28 above but 200mm dia complete all as specified and directed.
All as per item No 28 above but 300mm dia complete all as specified and directed.
M&L for concrete bed in PCC (1:3:6) type C2 (using 40mm graded stone aggregated) to drain pipes including packing under and haunching against the sides of the pipes after laying & testing for 150mm dia of pipes complete all as specified and directed.
All as per item No 31 above but 200mm dia complete all as specified and directed.
All as per item No 31 above but 300mm dia complete all as specified and directed.
M&L for SGSW (Grade 'A') drain pipes confirming to IS size 150mm laid in trenches and jointed in CM 1:2 complete all as specified and directed.
M&L for reinforced concrete pipes, class NP2, laid and jointed complete with collar for the 200mm internal dia of pipes complete all as specified and directed.
All as per item No 35 above but 300mm dia complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling, mass concrete complete all as specified and directed.
M&L for providing cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping benching, bed plates and the similar including, weathering, slightly rounded or chamfered edges and throating complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
Demolition of reinforced cement concrete any description not exc 15 cm thick complete all as specified and directed.
M&L for precast RCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in manholes covers, perforated drain cover slabs and similar work including form work etc complete all as specified and directed.
M&L for RCC type A1, (1:1.5:3), (using 20mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies etc complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia cut to lengths bent to shape as required including cranking, bending spirally for hooking and binding with MS wire (annealed) not less than 0.9 mm dia etc including handles for MH covers etc complete all as specified and directed.
M&L for TMT bars 10mm dia and over cut to lengths bent to shape as required including cranking, bending spirally for hooking and binding with MS wire (annealed) not less than 0.9 mm dia etc including handles for MH covers etc complete all as specified and directed.
Dismantling of 100mm dia cast iron pipe jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. Note:- Rate quoted is deemed to include earthwork excavation.
S&F in repair cast iron soil, waste and vent pipes, 100mm dia in any length with or without ears with cement joints, fixed to walls complete all as specified and directed.
S&F fitting for cast iron pipes bends of 100mm bore diminishing pieces or trapes (larger bore measured) complete all as specified and directed.
S&F fitting for cast iron pipes branch pieces 100mm bore, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F fitting for cast iron pipes sockets (double), collars of 100mm bore complete all as specified and directed.
Taking down of PVC, pipes of any size or pattern including all fittings etc complete all as specified and directed.
S&F in repair PVC (SWR) pipes 150mm dia, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair PVC (SWR) pipes 110mm dia, single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S&F in repair PVC (SWR) pipes 75mm dia complete all as specified and directed.
S&F in repair PVC (SWR) bends with access door any radius, 110mm dia complete all as specified and directed.
S&F in repair PVC (SWR) bends with access door any radius, 75mm dia complete all as specified and directed.
S&F in repair PVC (SWR) branch piece, double (double Y) equal or unequal with access door, 110mm dia complete all as specified and directed.
S&F in repair PVC (SWR) branch piece, double (double Y) equal or unequal with access door, 75mm dia complete all as specified and directed.
S&F in repair PVC (SWR) junction double, (double T), equal or unequal with access door, 110mm dia complete all as specified and directed.
S&F stack clamp made out of 50x5 mm flat iron for 75mm dia of pipe complete all as specified and directed.
S&F stack clamp made out of 50x5 mm flat iron for 100mm dia of pipe complete all as specified and directed.
S&F in repairs PVC (SWR) nahani trap 75mm dia with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair vitreous china squatting pan "Orissa pattern" size 630x450mm white with integral foot rests including connection to trap and to flushing pipe anti-syphonage pipe (excluding flushing cistern and flush pipe) etc including provn of lime concrete bedding and making good to floor complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including PVC cover complete all as specified and directed.
S&F in repair vitreous china wash basin, white, flat back, size 450x550 mm excluding taps, waste,chain and plug and porcelain stopper but including brackets and fixing of flush pipe, waste fitting, PVC connection and pillar tap complete all as specified and directed.
S&F in repair health faucet with 1 mtr tube & hook (braded Tube) complete all as specified and directed. Make:- Prayag Cat No BEA 81 or equivalent.
S&F in repair jet spray (Butterfly) with 1 mtr tube complete all as specified and directed. Make:- Prayag Cat No BEA-17 or equivalent.
Dismantling floor, hearth or wall tiles including cement mortar bedding, but not backing, removing serviceable tiles and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile not exceeding 0.11sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM (1:4) finished fair and even for laying floor finishes/ tiles etc complete all as specified and directed.
M&L for glazed ceramic coloured tiles (300mm x 450mm, Make as approved by GE) on vertical surface such as skirtings/ dados, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick backing coat in CM (1:3) finished even and fair complete all as specified and directed.
Taking up or down steel tubing and connection of 15mm bore complete all as specified and directed.
Taking up or down steel tubing and connection of 20mm bore complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10cm girth complete all as specified and directed.
S&F GI tubing 15mm bore medium grade with all fittings and fixed to wall complete all as specified and directed.
S&F GI tubing 20mm bore medium grade with all fittings and fixed to wall complete all as specified and directed.
S&F in repair vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
S&F CP brass urinal spreader for fixing with 15mm dia pipe complete all as specified and as directed.
S&F plastic water closet seat white, closed pattern with flat bottom and cover and mild steel C.P or aluminium hinging device complete all as specified and directed.
S&F in repair 10 ltr PVC valveless, syphonic action type, flushing cistern,low level, white, with inlet,ball valve, float and handle including brackets and Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
S&F flush pipe of polythene of low or high density 32mm PVC for low level flushing cistern complete all as specified and directed.
S&F low density PVC pipe 32mm dia as in waste pipe to sink complete all as specified and directed.
S&F in repair 15mm bore bib tap cast copper alloy with crutch or butterfly handels screwed down for iron pipes or for brass ferrule complete all as specified and directed.
S&F in repair stop valve/angle valve 15mm dia, cast copper alloy, chromium plated, fancy type, high pressure with crutch or butter fly handle screwd for iron pipe or union and fixed complete all as specified and directed.
S&F in repair 15mm bore pillar taps cast copper alloy fancy type chromium plated screwed down high pressure with or without lattered HOT or COLD with long screwed shanks and fly nuts screwed for iron pipes complete all as specified and directed.
S&F low density PVC pipe 40mm dia as in waste pipe to sink complete all as specified and directed.
S&F low density PVC pipe 50mm dia as in waste pipe to sink complete all as specified and directed.
S&F in repair 15mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 20mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 25mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
M&L for 100mm thick cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and no pigment finished with coloured rubber finish on top finished over sand dust cushion of 30mm thick complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20mm thick for laying floor finishes in cement mortar (1:6) complete all as specified and directed.
M&L for chequered tiles 300 x 300 x 25mm thick, rubber finished, set jointed and pointed in neat and cement slurry in floors with grey cement and pigment complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed .
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished fair and even all as specified and directed.
M&L for form work to soffits of suspended slabs, such as roof slabs and similar work; not exc. 200 mm thick for flat rough finish surfaces.
Disconnectiong existing tanks of capacity exc 250 & not exc 500 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position including cleaning and removing all the scale and dirt, etc from tank and from mouths of circulating pipes etc and writing the date as "TANK CLEANED ON 22 AUG 2021" white or black thick synthetic enamel paint complete all as specified and directed.
Disconnectiong existing tanks of capacity exc 500 & not exc 1000 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position including cleaning and removing all the scale and dirt, etc from tank and from mouths of circulating pipes etc and writing the date as "TANK CLEANED ON 22 AUG 2021" white or black thick synthetic enamel paint complete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.14,965.00]
Meet Road Lines
M/s Jagdish Staioners and General Stores
M/s DS Khekde
M/S J.A CHAWHAN
Bidder Name
Meet Road Lines
M/S J.A CHAWHAN
Shri Mohan Brother
M/s DS Khekde
M/s Jagdish Staioners and General Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .