| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹12.9 L+₹2,306 (0.18%)Rejected-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-AOC Other than the lowest bidder | |
| 3 | L3₹13.7 L+₹83,097 (6.47%)Rejected-AOC | L3 | Rejected-AOC Other than the lowest bidder | |
| 4 | L4₹13.9 L+₹1.0 L (8.00%)Rejected-AOC | L4 | Rejected-AOC Other than the lowest bidder | |
| 5 | L5₹18.2 L+₹5.3 L (41.6%)Rejected-AOC H NO 816 NEAR GANDHI CHOWK KALKA 133302 HARYANA | KALKA | PANCHKULA | HARYANA | 133302 | L5 | Rejected-AOC Other than the lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
23 Jul 2024, 6:00 pmClosed
GE (I) JUTOGH
GE (I) JUTOGH, JUTOGH CANTT SHIMLA (HP) - 171008
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION, DISTRIBUTION BOXES WITH ALLIED WORKS IN MD/ OTM ACCN AND SERVICES OF DG SETS, LT PANELS AND CONNECTED MISC ITEMS AT MIL STN KALKA UNDER GE (I) JUTOGH
2024_MES_662309_1
GE(I)/JUT-14 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
KALKA
CLASS E CATEGORY b (i)
7 documents required · 7 mandatory
₹500
GE (I) JUTOGH
₹40,000
Yes
8 Oct 2024
26 Jun 2024
25 Jul 2024
26 Jun 2024
23 Jul 2024
9 Jul 2024
26 Jun 2024 - 2 Jul 2024
Amount
Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose , pendant holder, fitting and fixtures , MCB, Main switches, call bell etc and making good to disturbed surface to wall ,floor etc to match with existing surface either by using same colour distemper or white colour wash, complete all as specified and directed.
Taking down carefully unserviceable main switches and distribution boards (single phase or three phase) of any capacity with Isolators/ MCBs/ MCCBs, complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring and making good disturbed surfaces and matching with existing complete all as specified and directed.
M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated (FRLS-H) and unsheathed size 1.5 sqmm with concealed conduit PVC Medium grade not less than 20 mm dia with fixing accessories, to be fixed , for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly, colour code of wires as per specification, complete all as specified and directed.
All as per srl item No 4.00 above but for one 5 pin 5/6 Amp socket on the same board, complete all as specified and directed.
All as per srl item No 4.00 above but for one 5 pin 5/6 Amp socket on independent board, complete all as specified and directed.
All as per srl item No 4.00 above but for one 3 pin 15 Amp socket independent but with 2.5 q mm PVC insulated unsheathed copper stranded conductor and earth wire with 2.5 Sqmm, complete all as specified and directed.
S & F switch piano type 240 V, 5 Amp , Single pole one way flush type complete all as specified and directed.
S & F bell push 240 V, 5 Amp , Single pole one way flush type complete all as specified and directed.
S&F Socket 5 pins, 6 Amp, flush type piano (multi purpose) , complete all as specified and directed.
S&F Socket 15 Amps flush type 230 Volts , AC complete all as specified and directed.
S&F Switch 15 Amps flush type 230 Volts , AC complete all as specified and directed.
M&L for Step type Fan regulator Electronic type 240 Volt single phase one module suitable for ceiling fan complete all as specified and directed.
S&F ceiling rose polycarbonate body, 65 x 20 mm three terminal complete all as specified and directed.
S&F for lamp holder pvc body with back plate complete all as specified and directed.
S&F VTPN MCCB distribution board 4 way fabricated out of thick high quality CRCA sheet, DBs shall be totally enclosed, suitable for 240V/415V, having polyurethane (PU) foam gasket to ensure IP-43 degree of protection for Indoor application as pre IEC 61439-3:2012 (CI. 10.3)/IEC 60529.DB shall be robust with tested for impact resistance IK09as per IEC 61439-3:2012(CI.No. 10.2.6).DBs shall be provided with prefitted cement Guard. DB Door shall have detachable gland plates provided with proper knockout holes of 26mm/35mm diameter for intsertion of cable /conduits. Distribution Boards shall bre provided with wire set of copper along with the insulated fork type bus bars. DB shall heve reversible hinged doors and possibility to allow door opening from left to right or right to left for convenience on site. DB shall have type test reports as per IEC 61439-3 from ERDA or NABL laboratery complete all as specified and directed.
S&F TPN Distribution board 4 way fabricated out of thick high quality CRCA sheet, DBs shall be totally enclosed, suitable for 240V/415V, having polyurethane (PU) foam gasket to ensure IP-43 degree of protection for Indoor application as pre IEC 61439-3:2012 (CI. 10.3)/IEC 60529.DB shall be robust with tested for impact resistance IK09as per IEC 61439-3:2012(CI.No. 10.2.6).DBs shall be provided with prefitted cement Guard. DB Door shall have detachable gland plates provided with proper knockout holes of 26mm/35mm diameter for intsertion of cable /conduits. Distribution Boards shall bre provided with wire set of copper along with the insulated fork type bus bars. DB shall heve reversible hinged doors and possibility to allow door opening from left to right or right to left for convenience on site. DB shall have type test reports as per IEC 61439-3 from ERDA or NABL laboratery complete all as specified and directed.
S&F sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for MCB SPN as incomer complete all as specified and directed.
S&F sheet metal enclosures for MCB distribution board SPN 4 way double door type with 200 amp rated bus bar and suitable for MCB SPN as incomer complete all as specified and directed.
S&F MCCB thermal based release adjustable type 4 pole 100 Amps 50 Hz 415 Volts with rupturing capacity 16 KA min including testing, complete all as specified and as directed.
S&F MCB Single pole 6A to 32A rating, 240/415V, having short circuit breaking capacity icn = 10kA, " B" curve characterstics, suitable for resistive & inductive load. MCB shall have true position indicator on the front facia. MCB shall have bi-connect arrangement on top & bottom for simultaneous connection of cable and busbar. MCB shall have line load reversibility. MCB shall have ISI marking with latest type test reports as per IS/ IEC 60898/IEC 60947-2 standard, complete all as specified and directed.
All as per ser item No 21.00 above but for MCB SPN 40 Amps, complete all as specified and directed.
All as per ser item No 21.00 above but for MCB TPN 63 Amps, complete all as specified and directed.
M&L for replacement of call bell electric (ding dong type), 240 Volt, single pole, complete all as specified and directed.
M&L for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS-H cable drawn and PVC rigid conduit min 20 mm dia with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 6 Sqmm as earth wire (green in colour) run through PVC rigid conduit and connected to common earth dolly, complete all as specified and directed. Note:- Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 20 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified including all earth work excavation, returning filling and disposal of surplus soil and testing on completion, complete all as specified and directed.
S & F LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F 20W, 6500K, 4 feet LED tube light fitting, energy efficient, 240 volts, fixed on wall/ ceiling etc incl. connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
S&F LED tube light along with fixture, 1x 10 watt, (2 Feet) wall mounted LED battern (mirror light), extrudedd PVC, heat sink provided for efficient heat dissipation & integrated electronic driver, optics diffussed, complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings and all fixing arrangements complete all as specified and directed.
S&F LED bulb of 9 watt, B-22 base, 6500K, complete all as specified and directed.
S&F in repair LED Post top 20 watt decorative type,made of cast aluminium with decoratice opal polycarbonate diffusar with IP-65 protection including fixing with suitable size GI pipe as required on the top of gate pillar including all fixing accessories complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size ccomplete all as specified and directed.
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
S&F in repair Capacitor (ISI Marked) 2.5 mfd complete all as specified and directed.
S & F in repair modular Switch one way 6 A, 1 module complete all as specified and directed.
S & F in repair Modular Switch one way 16 A, 1 module complete all as specified and directed.
S & F in repair Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
S & F in repair Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all asper specified and directed.
M&L for servicing of storage type water heater (Geysers) 50/25 ltr capacity any make by disconnecting electrically and mechanically from all existing lines, opening of bottom and top for inspection complete incl base plate, heating element and copper tank , cable, PVC pipe etc, cleaning carefully and reassembling after necessary repair/ replacement as specified here-in-after and replacement of old unserviceable nut/bolts and fixing in the same position complete all as specified and directed. Note :- Spare parts shall be measured and paid separately.
Supply only heating element 1500 watts push type with gasket ISI marked triangular type complete all as specified and directed.
Supply only thermostatic switch suitable for Gysers of any make/ type with temperature range adjustable type 25 to 80 degree centigrade superior quality 20 Amps 220 Volts AC Supply complete all as specified and directed.
Supply only Incoloy Heating Element 111884 -EV for Geyser complete all as specified and directed.
Supply only syphon assembly suitable for 25 Ltrs capacity Geysers of any type having 6/9 hole, complete all as specified and directed.
Supply only PVC connection of 450 mm long & 15 mm dia with brass nut at both end suitable for Geysers complete all as specified and directed
S&F in replacement LED indicator lamp red & green as per existing shape and size, 230V etc complete all as specified and directed.
S&F in replacement 3 pin Bakellite Top of 16 Amp capacity, 240V only for repalcement of burn/ unsv top for geyser, complete all as specified and directed.
M&L for Servicing of DG Set (Make: Ashok Layland) of capacity 30 kVA ,checking entire system as per manufacturer's catalogue such as checking all parts for serviceability, taking down defective parts such as fuel filter assembly, by pass filter assembly, lube oil filter assembly, air cleaner assembly etc and replacing the same with same size, make and capacity of parts, Cleaning all the serviceable filters and draining out the old used engine oil from the oil sump and cleaning oil sump,and refilling new engine oil of required grade up to required level and including checking of control panel, tightening of loose connections and testing to DG Set to the entire satisfaction of the Engineer-in-Charge. Note : (i) Minor items like nut, bolts, lugs , cloths , cotton etc are incl in quoted rates. (ii) Spare parts/Engine oil / filters shall be measured and paid for separately under successive items here-in-after. However, labour charge are deemed to be included in item rate above.
Air filter in
Air filter out
Lub oil filter
Fuel filter element
M&L for Servicing of DG Set (Make: Mahindra) of capacity 100 kVA ,checking entire system as per manufacturer's catalogue such as checking all parts for serviceability, taking down defective parts such as fuel filter assembly, by pass filter assembly, lube oil filter assembly, air cleaner assembly etc and replacing the same with same size, make and capacity of parts, Cleaning all the serviceable filters and draining out the old used engine oil from the oil sump and cleaning oil sump,and refilling new engine oil of required grade up to required level and including checking of control panel, tightening of loose connections and testing to DG Set, complete all as specified and directed. Note : (i) Minor items like nut, bolts, lugs , cloths , cotton etc are incl in quoted rates. (ii) Spare parts/Engine oil / filters shall be measured and paid for separately under successive items here-in-after. However, labour charge are deemed to be included in item rate above.
Air filter
Lub oil filter
Fuel filter element
M&L for Servicing of DG Set (Make: Mahindra) of capacity 200 kVA, checking entire system as per manufacturer's catalogue such as checking all parts for serviceability, taking down defective parts such as fuel filter assembly, by pass filter assembly, lube oil filter assembly, air cleaner assembly etc and replacing the same with same size, make and capacity of parts, Cleaning all the serviceable filters and draining out the old used engine oil from the oil sump and cleaning oil sump,and refilling new engine oil of required grade up to required level and including checking of control panel, tightening of loose connections and testing to DG Set complete all as specified and directed. Note : (i) Minor items like nut, bolts, lugs , cloths , cotton etc are incl in quoted rates. (ii) Spare parts/Engine oil / filters shall be measured and paid for separately under successive items here-in-after. However, labour charge are deemed to be included in item rate above.
Air filter in
Air filter out
Lub oil filter
Fuel filter element
Fan belt for water pump
Fan belt for alternator dynamo
S&F in replacement maintenance free battery 12V 150 AH, incl dismantling and taking down old unser batteries, complete all as specified and directed.
Supply and filling of sealed coolant for DG Sets complete all as specified and directed.
Supply & filling Sealed engine oil 15W 40 in DG sets including Drain out the old engine oil, clean the oil sump complete all as specified and directed.
S&F Battery Terminals Copper.(Positive & Negative) complete all as specified and directed.
Supply & fixing Battery Copper cable Red/Black with plug complete (1 Mtr Length), complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 mm thick CRCA/ MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) with Synthetic enemal Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS-H cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate comprising of following:-
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth means of GI Strip 32X6 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through GI pipe for protection of earth lead wire incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing earthing complete all as specified and directed. Note: Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead up to 7.5 mtr .
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 25KVA-250 KVA, comprising of following jobs complete all as specified and as directed:- (a) Free maintenance and repair of Normal accessories (Spare Parts), Servo Voltage Stabilizer/ Servo Voltage Regulator. (b) Dismantling and removing of defective voltage stabilizer, checking of Main MCCB in over to avoid tripping on main supply, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making internal wire connection serviceable and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load. (c) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (d) Attending all complaints within 24 working hours. Note:- (i) Replacement of defective spares for making the Voltage Stabilizer units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only'. These shall be identical to those specified by the original manufacturer. (ii) Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate.
S&F in replacement of Trigger Transformer (18V) complete all as specified and directed.
S&F in replacement of Push Button/ Auto Manual Switch/ Micro Switch Potentiometer/ Limit Switch/ Lever Switch complete all as specified and directed.
S&F in replacement of Carbon bushes complete all as specified and directed.
S&F in replacement of Servo Motor 3 Kg with RC suitable for 25 KVA Voltage Stabilizer, complete all as specified and directed.
S&F in replacement of Servo Circuit Card (PCB) complete all as specified and directed.
Dehydration/ filtration of voltage stablizer oil of voltage stabilizer of any capacity upto 250 KVA by disconnecting plants electrically for recirculation existing volatge stablizer oil with trolley mounted filtration plant till dielectric strength is up to 45 KV to 50 KV in 2.5mm gap. Note- Quoted rates shall be deem to include for following :- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) Transformer oil for topping up will be measured and paid in relevant item as required.
Supply & topping up of oil for voltage stablizer up to required level for voltage stabilizers of dielectric strength 50 KV & above complete all as specified and directed.
M&L for painting of LT Panel complete with two coats of synthetic Enamel paints over a coat of red oxide and other necessary fabrication work like replacement of hinges ,locking Knobs, bending and welding work required for hinges etc as per required at site complete all as Specified and directed. Note :- Fabrication work like replacement of hinges, locking Knobs, CRCA/ MS sheet fabrication work as required at site is included in the unit rate quoted against this item.
S&F Alko sign board of size 1.80x 1.2 m made of almn frame included velvet cloth in front and white sunmica at the backside complete all as specified and directed.
S&F in replacement of Indicator Lamp (RYB) complete all as specified and directed.
M/S Sonu Traders
MANSA ENTERPRISES
CHADHA ENGINEERS
m/s jupiter builders
Dharm Singh Contractor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .