| 1 | L1₹48.5 LAccepted-AOC | ₹48.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹48.6 L+₹8,505.34 (0.18%)Rejected-AOC | ₹48.6 L+₹8,505.34 (0.18%) | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | SRIDHAR L2 | J.Manimaran L1 |
|---|---|---|---|---|---|
| 1.001.)1.) Construction of Sub Health Centre Building at 74,Krishnapuram H/O 74,Krishnapuram Panchayat | |||||
| 2.00 | Clearing jungle including uprooting of trunk vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 72 | Sqm | 7 ₹504 | 6 ₹432 Lowest |
| 3.00 | Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation. | 167.4 | cum | 265 ₹44,361 | 263 ₹44,026.2 Lowest |
| 4.00 | Septic tank | 24.2 | cum | 265 ₹6,413 | 263 ₹6,364.6 Lowest |
| 5.00 | Paver block arrangements | 3.3 | cum | 265 ₹874.5 | 263 ₹867.9 Lowest |
| 6.00 | Supplying and Filling foundation and basement with filling Msand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification. | 20.6 | cum | 2,238.79 ₹46,119.07 | 2,238 ₹46,102.8 Lowest |
| 7.00 | Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers is not exceeding 200 mm thick, with available earth at site. | 117.1 | cum | 45.85 ₹5,369.04 Lowest | 45.85 ₹5,369.04 Lowest |
| 8.00 | Supplying and filling of good Gravel filling locally available earth transported from the outside including consolidation, leveling specified in layers of not exceeding 200 mm thick., etc. complete. | 2.2 | cum | 280.34 ₹616.75 | 280 ₹616 Lowest |
| 9.00 | Cement concrete 1 : 4 : 8 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed for foundation | 27.3 | cum | 6,127.06 ₹1,67,268.74 | 6,127 ₹1,67,267.1 Lowest |
| 10.00 | Septic tank | 2 | cum | 6,127.06 ₹12,254.12 | 6,127 ₹12,254 Lowest |
Tender Value
₹50 L
EMD Value
₹50,000
Closing Date
24 Sept 2025, 3:00 pmClosed
Block development officer
Union office Gangavalli
Construction of Sub Health Centre Building at 74,Krishnapuram H/O 74,Krishnapuram Panchayat
2025_RDTN_602551_1
Roc No1891/2025/A2
Open Tender
Civil Works
Item Wise
Bdo office Gangavalli
Construction of Sub Health Centre Building at 74,Krishnapuram H/O 74,Krishnapuram Panchayat
3 documents required · 3 mandatory
₹0
₹50,000
21 Aug 2026
11 Sept 2025
24 Sept 2025
11 Sept 2025
24 Sept 2025
11 Sept 2025
Amount
1.)1.) Construction of Sub Health Centre Building at 74,Krishnapuram H/O 74,Krishnapuram Panchayat
Clearing jungle including uprooting of trunk vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
Septic tank
Paver block arrangements
Supplying and Filling foundation and basement with filling Msand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification.
Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers is not exceeding 200 mm thick, with available earth at site.
Supplying and filling of good Gravel filling locally available earth transported from the outside including consolidation, leveling specified in layers of not exceeding 200 mm thick., etc. complete.
Cement concrete 1 : 4 : 8 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed for foundation
Septic tank
Paver block arrangements
Plain Cement Concrete 1:2:4 (one cement, two M.Sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
Supplying & Erecting centering for sides & soffiots including necessary supports for all Rcc works etc.complete Upto Basement
Septic tank
Paver block arrangements
Supplying & Erecting centering for sides & soffiots including necessary supports for all Rcc works etc.complete Ground floor
Cement concrete 1:3:6 mix using 20mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing,laying and curing etc complete
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .
Providing and Laying of Interlocking Concrete (Surface Textured) Block Pavements having thickness 60mm and compacted over a thin bedding M.Sand layer of 25 mm thickness and joints shall be filled by fine M.Sand of specified grading as per table 1500.6 of Specification of Rural roads-2014 and Technical specification clause 1504.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement ratio with plasticizer using 20mm and down concrete structural elements under controlled water graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the depart- mental officers comple
Ground Floor
Supply & Fabrication of steel including all cost and conveyance of all materials to site and all labour charges for etc., complete.
Septic tank
Reinforced Cement Concrete 1:1.5:3 mix using 20 mm metal for all items including cost & conveyance and labour charges etc complete. Septic tank
Brickwork in CM 1:5 mix using country bicks including cost & conveyance of all materials to site and all labour charges for curing, compacting etc., complete. Foundation & Basement
Ground Floor
Septic tank
Brick partition walls of 11.50cm thickness using best quality Country bricks of size 8"3/4 x 41/4" X2 3/4" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately).
Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete
Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or chambering of corners, offsets, fin/ bands, projections, etc.
Septic tank
Paving the floor with best quality Vitrified Tiles of size 600 x 600 x 8mm of approved color, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same color pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing the walls with coloured Dadooing Ceramic tiles of size 300mm x 450mm x 8mm approved size , quality and colour set in CM 1 : 2 - 10 mm thk. And pointed with suitable cement including finishing the joint and pointing flesh with walls and tile surface in all floors at the rate of 0.40 Kg /Sqm etc. complete.
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.
Providing, fabricating and fixing M.S. grills Windows, and ventilator,gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by the Engineer.
Manufacturing,supplying and fixing of stainless steel hand rails for staircase using 50mm dia 304L grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between.The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance,electrical charges,ect.complete.
Supply and Fabrication of UPVC door including cost and conveyance of all charges etc complete.
Solid PVC door shutters Toilet door using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings.The over all size of styles shall be 50mm x 30mm.The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.
UPVC Window supplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride) windows of casement type (open) from the profile the size of outer frame 60mmx58mm and shutter profile are reinforceement with gi/1mm 125GSM and 100% corrosion free, the profiles are mlulti chamberedcv section with wall thick of 2mm.The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power points locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brownclour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action,security protective hinges,strong locking systems and as per size for arresting noise and energy loss. The connecting mechanisim between sah and outer frame that enables opening of the window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames The window should be got approved from the Executive Engineer before use on work.
UPVC VENTILATOR:Supplying and fixing UPVC (Un-PLASTICIZED Polyvinyl chloride)Louvered Ventilators of from the profile the size of outer frame 60x58mm and shutter profile the size of 60x78mm both profile size of 60x78mm both profiles are reinforced with GI/1MM 125GSM and 100% corrosion free,the profile are mulit chambered sections with wall thick of 2mm.The EPDM rubber ( black colour) covered with all over he edges of frame and shutter.The corners and joints should be welded and cleaned.Radiation pin headed glass 4mm thick should be fixed to the wall with 100% packing with screws and silicon packing all aroundthe frame.The ventilator should be got approved from the Executive Engineer before use on work.
Distempering in two coats using oil bound distemper including cost and conveyance of all materials to site and all labour charges etc complete.
Painting in two coats using exterior emulsion paint including cost and conveyance of all materials to site and all labour charges etc complete.
Painting two coats with approved quality Enamel paint over New iron work including cost & Conveyance and all labour charges etc complete.
Weathering course concrete using best quality broken brick jelly of size 20mm in pure slacked lime over the RCC roof slab in th proportion of brick jelly to lime being32:12.5 by the volume and laid over a single layer and consolidated to the required dsesign & finished thick. beating the concrete with wooden beaters of approved pattern, keeping the surface contantly wetted with sprinking lime & jaggery water as per standard specifications etc., complete as directed by the departmental officers. Rate for 10m3
Finishing the top of roof with one course of machine pressed tiles of size 20 x 20 x 2cm (100% new tiles ) of approved quality laid in CM 1:3, 12mm thick. With water proofing compound confirming to IS by 2% by weight of cement used & the joint pointed neatly to full depth of tiles with the same water proofing compound mixed with cement mortar, Red oxide etc., complete complying with standard specifications. Rate for 10m2
Providing the following thickness of Granolithic pattern floor finish with Plain Cement concrete 1 : 2 : 4 mix using 10-12mm ISS HBG metal and the top rubed smooth etc., complete complying with standard specification as directed. Rate for 10 m2
Supplying and fixing in position C.I.Manhole covers (heavy duty) mof various sizes of best approved quality and as per standard specificationsetc., complete.0.6X0.6M Size etc., complete.
Supply and Fixing of Indian Water Closet with P Trap best quality and approved including all Cost etc complete.
Supplying and fixing of Indus floor mounted white colour European water closet Parryware or equivalent, with seat cover and dual flush (3 & 6 lit) cistern having P trap with seat cover, supplying non corrosive hinges, CP bolts, nuts, washers, providing and fixing dash anchor fastners with bolts / L - brackets with anticorrosive paint cutting grooves in masonry or concrete surfaces, grouting with cement concrete 1:2:4 mix, using 20mm size stone jelly,restoring the damaged portion to their original condition using required materials,fixing the water closet to perfect level,alignment,testing etc.complete.
Providing and keeping in stores, shifting to the place of installation, fixing, testing and commissioning of white coloured vitreous china under counter Regular rectangular wash basin with brackets / G.I. rag bolts and nuts painted, 32mm dia brass C.P. waste coupling, (heavy) 32mm dia brass C.P. bottle trap, 15mm dia brass C.P. Angle stop cock with flange, 15mm dia brass C.P. cold water connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors - toilets. Wash Basin
Supply and delivery of 1000 litre HDPE tank
Supply of 20mm PVC Pipe
Supply of PVC Screw Down Tap Heavy Type 20mm dia
Supply of 20mm PVC Elbow
Supply of 20mm PVC Tee
Supply of 110mm PVC Tee
Supply of 110mm PVC Bend
Supply & delivey of ISI marked 4 KSC 110 mm PVC pipes
Supply & laying of ISI marked 4 KSC 110 mm PVC pipes
Wiring with 2x1.5 Sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5a F.T switch with continuous earth wire connection of 14 SWG TC Wire of making good of the concealed portion with suitable colour for PVC Concealed light point / Fan point (for electronic regulator) SD.25
Wiring with 2x1.5 Sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5a F.T switch with continuous earth wire connection of 14 SWG TC Wire of making good of the concealed portion with suitable colour for PVC Concealed light point / Fan point (for electronic regulator) SD.26
Wiring with 2x1.5 Sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories in flush with wall with 150mmx100mmx113mm TW Switch box with 3 mm thick Hylem Sheet cover for 5 A 3 pin non inter locking CS plug with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point SD.38
Wiring with 2x1.5 Sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories in flush with wall with 150mmx100mmx113mm TW Switch box with 3 mm thick Hylem Sheet cover for 5 A 3 pin non inter locking CS plug with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC Power plug point SD.40
Supply and fixing of 1200 mm ( 48") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mm down rod on the existing clamp. SD 106
Supply and fixing of 300mm (12") sweep (lightduty) AC exhaustfan complete with necessary wall opening and making good of the wall (SD.114)
Supply and fixing of fancy glass shade and 7W / 9W LED bulb (SD.88)
Supply and fixing of TNEB meter Board suitable for 32A single phase service connection with 32 A Fuse unit (500V) 32 A neutral link and earth ling (1"x1/8" Copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EBV Meter to fues unit (SD.128)
Supply and run of 1 of No.8 SWG GI wire for earth connection (SD.74)
Supply and run of 2 of 4 Sqmm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 v grade on 7/20 GI Bearer wire for Service connection mains (SD.66)
Provision for furniture
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
SRIDHAR (BID ID -1467040)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .