| Sl No | Description | Qty | Unit | Mehar Enterprises L5 | HYDROCON ENGINEERS L4 | JAI DURGA ENGINEERS AND CONTRACORS L6 | Super System Engineers L3 | paramount systems L2 | Raj Engineering Co. L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.01 | Replacement of old damaged Sewage pump set with other allied works at GT Road Seelampur SPS including following works :-Dismantling of old damaged complete pump set from foundation by removing of coupling, valves, Cables & cutting of old rusted nut bolts with the help of man power , gas cutter etc and shifted the old material to the JE store. | 2 | Jobs | 12,400 ₹14,632 | 5,000 ₹5,900 | 14,000 ₹16,520 | 11,000 ₹12,980 | 2,000 ₹2,360 | 7,000 ₹8,260 |
| 1.02 | S/o of sewage solid handling non clog pump with SS Impeller, CI casting , SS shaft & SS sleeve, Size 125 x100mm suitable for head-m 15 mtr , Capacity :290 m3/hr coupled with 25 HP , 1450 RPM, 3 PH, TEFC Sq Cage Induction AC Motor mounted on Common Base Frame.( Only pump i/c tyre coupling). Make : Kirloskar/ M&P/Crompton / ABB/ Jyoti/ any DJB approved | 2 | Sets | 6,26,520 ₹7,39,293.6 | 6,16,000 ₹7,26,880 | 7,14,000 ₹8,42,520 | 4,48,000 ₹5,28,640 | 4,50,000 ₹5,31,000 | 3,98,000 ₹4,69,640 |
| 1.03 | Supply of insulating matt for electrical purpose of size 1 M X 2 M & 3mm thick class A voltage up to 3.3 KV -Make:- Jyoti/ National | 2 | Nos. | 3,000 ₹3,540 | 1,000 ₹1,180 | 3,100 ₹3,658 | 4,500 ₹5,310 | 10,000 ₹11,800 | 2,860 ₹3,374.8 |
| 1.04 | S/o CI/DF swing type non return valve of 125 mm size as per IS 5312 (part 1&2) PN 1.0 C I body, door/ bronze to rubber rings/ SS hinge pin. Make Kirloskar / IVC/ Djb approved make | 2 | Nos. | 34,000 ₹40,120 | 70,000 ₹82,600 | 38,000 ₹44,840 | 39,000 ₹46,020 | 40,000 ₹47,200 | 40,800 ₹48,144 |
| 1.05 | S/o 100mm CI double flanged non rising spindle sluice valve PN 1.0 CI body door /bronze to rubber ring / SS 410 shaft construction. Make : Kirloskar/IVC/Djb approved make | 2 | Nos. | 37,000 ₹43,660 | 60,000 ₹70,800 | 42,000 ₹49,560 | 27,000 ₹31,860 | 20,000 ₹23,600 | 24,800 ₹29,264 |
| 1.06 | S/o 4Pole 415 V 400 Amp. heavy duty off load change over switch with side handle in sheet enclosure. Make : Havells/Bentex/Capital/HPL/L&T | 1 | No. | 22,500 ₹26,550 | 500 ₹590 | 23,000 ₹27,140 | 38,500 ₹45,430 | 15,000 ₹17,700 | 23,000 ₹27,140 |
| 1.07 | S/o 4 pole 415V 400 amp Main swicth with side handle in sheet enclosure. Make: Havells/Bentex/Capital/HPL | 1 | No. | 22,550 ₹26,609 | 500 ₹590 | 23,650 ₹27,907 | 25,000 ₹29,500 | 15,000 ₹17,700 | 23,000 ₹27,140 |
| 1.08 | S/o 125mm dia medium class MS Pipe. Make : Jindal / TATA | 12 | Mtrs. | 13,800 ₹16,284 | 6,000 ₹7,080 | 14,040 ₹16,567.2 | 34,200 ₹40,356 | 18,000 ₹21,240 | 14,400 ₹16,992 |
| 1.09 | S/o 100mm dia medium class MS Pipe. Make : Jindal / TATA | 10 | Mtrs. | 8,800 ₹10,384 | 4,500 ₹5,310 | 8,800 ₹10,384 | 25,000 ₹29,500 | 12,000 ₹14,160 | 9,800 ₹11,564 |
| 1.10 | S/o 125mm dia flange | 8 | Nos. | 2,800 ₹3,304 | 400 ₹472 | 2,880 ₹3,398.4 | 22,400 ₹26,432 | 3,200 ₹3,776 | 3,040 ₹3,587.2 |
Tender Value
Refer Docs
EMD Value
₹25,100
Closing Date
6 Mar 2026, 11:00 amClosed
Office of the Ex. Eng. (E and M) M-2
Pocket-A, Dilshad Garden, Delhi-110095
Replacement of old damaged Seweage pump set with other allied works at GT Road Seelampur SPS.
2026_DJB_287854_23
NIT No. 30 (25-26)
Open Tender
Miscellaneous Works
30 days
GT Road Seelampur SPS.
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Ac No. 50448339804
₹25,100
12 Mar 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
Replacement of old damaged Sewage pump set with other allied works at GT Road Seelampur SPS including following works :-Dismantling of old damaged complete pump set from foundation by removing of coupling, valves, Cables & cutting of old rusted nut bolts with the help of man power , gas cutter etc and shifted the old material to the JE store.
S/o of sewage solid handling non clog pump with SS Impeller, CI casting , SS shaft & SS sleeve, Size 125 x100mm suitable for head-m 15 mtr , Capacity :290 m3/hr coupled with 25 HP , 1450 RPM, 3 PH, TEFC Sq Cage Induction AC Motor mounted on Common Base Frame.( Only pump i/c tyre coupling). Make : Kirloskar/ M&P/Crompton / ABB/ Jyoti/ any DJB approved
Supply of insulating matt for electrical purpose of size 1 M X 2 M & 3mm thick class A voltage up to 3.3 KV -Make:- Jyoti/ National
S/o CI/DF swing type non return valve of 125 mm size as per IS 5312 (part 1&2) PN 1.0 C I body, door/ bronze to rubber rings/ SS hinge pin. Make Kirloskar / IVC/ Djb approved make
S/o 100mm CI double flanged non rising spindle sluice valve PN 1.0 CI body door /bronze to rubber ring / SS 410 shaft construction. Make : Kirloskar/IVC/Djb approved make
S/o 4Pole 415 V 400 Amp. heavy duty off load change over switch with side handle in sheet enclosure. Make : Havells/Bentex/Capital/HPL/L&T
S/o 4 pole 415V 400 amp Main swicth with side handle in sheet enclosure. Make: Havells/Bentex/Capital/HPL
S/o 125mm dia medium class MS Pipe. Make : Jindal / TATA
S/o 100mm dia medium class MS Pipe. Make : Jindal / TATA
S/o 125mm dia flange
S/o 100mm dia flange
S/o 125mm dia MS Bend
S/o 100mm dia MS Bend
S/o Nut bolts and washer off sizes.
S/o rubber insertion sheet 50% synthetic. Make : Jyoti
Supply of 3.5 core x 35 Sqmm PVC insulated armored inner sheathed aluminium conductor cable for making connection of motor & starter. Make : Grandlay /Polycab/National/ Djb approved make
Making of RCC foundation of size approx 2.5 mtr X2mtr X0.9m by 1:2:4 concrete including providing fixing of foundation bolt of suitable size.
Installation of new complete pumpset, cable and other parts with the help of heavy manual labour, tools and tackles i/c thimbling of cable at both side , installation of main switch and change over with proper fixing as per site requirement & testing , commissioning of pump set on full load in the presence of Engineer in charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
BOQ_381615.xls
BOQ • 0.25 MB
NIT.pdf
Tender Documents • 0.90 MB
Download all tender documents and submit your bid