Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.1 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹17.9 L+₹1.9 L (12.2%)Rejected-AOC 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | 2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical BLOCK NO 2 FLAT NO 17 FIRST FLOOR KENDRIYA VIHAR PARUTHIPATTU AVADI CHENNAI 600 071 | CHENNAI | CHENNAI | TAMIL NADU | 600071 | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
2 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services INS Adyar Old Building Fort St George Rajaji Salai Chennai 600 009
REPAIRS OR MAINTENANCE OF HT EXTERNAL SERVICES AND ITS CONNECTED WORKS AT PARUNDU UNDER GE TIRUNELVELI
2020_MES_338011_3
81344
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
TIRUNELVELI
As per tender documents
8 documents required · 8 mandatory
₹500
GE TIRUNELVELI
₹34,000
Yes
10 Oct 2020
17 Jun 2020
3 Jul 2020
17 Jun 2020
2 Jul 2020
18 Jun 2020
60 days
Amount
De-hydration/ filtration of transformer oil by employing on line filtration plant to achieve di-electric strength not less than minimum 50 KV including following work services complete all as specified and directed :- (a) Removal of all suspended particles such as dust, rust, scales, collided Carbon oxidation sludge, etc upto < 1 micron. (b) De-hydration of transformer oil under vacuum. (c) Circulation of heated oil and filling of treated oil in transformer tank. (d) Top up the transformer oil upto the level Note : (i) Contractor shall use the vehicle mounted filtration plant with new suitable size heavy duty hose pipe. (ii) The transformer oil required for replacing/top up shall be measured and paid separately . (iii) Conducting field testing of di-electric strength of the transformer oil before and after filtration
Material and Labour for transformer oil for top up in transformer complete all as specified and directed. Note : Sealed container only will be brought at site with minimum BDV 60 KV Make : HP/Bharath Petroleum/Power oil
Disconnecting HT/LT connection of transformer, 11000/433 V, 3 Phase, 4 wire system and opening up the top cover of transformer of capacity 400 KVA for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bus rods including necessary soldering/jointing etc... and after complete repair refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections complete all as specified and directed Notes : (i) Major parts as under shall be measured and paid separately under appropriate item of this BOQ. (iii) Dehydration/ filtration of transformer oil shall be measured and paid separately under relevant item of this BOQ. (iv) T&P and minor parts will be arranged by the contractor and the cost thereof shall deemed to be included in the unit rate quoted against this item (v) Rate deemed to be inclusive of securing the cables on HT/ LT side for tension free at cable entry box.
All as per Sl item No. 3 here-in-before but capacity of 250 KVA.
All as per Sl item No. 3 here-in-before but capacity of 200 KVA.
All as per Sl item No. 3 here-in-before but capacity of 100 KVA.
Disconnecting Primary/Secondary connection of transformer, 433 V/230 V, 3 Phase, 4 wire system and opening up the top cover of transformer of capacity 50 KVA for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bus rods including necessary soldering/jointing etc and after complete repair refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections complete all as specified and directed. Notes : (i) Major parts as under shall be measured and paid separately under appropriate item of this BOQ (iii) Dehydration/ filtration of transformer oil shall be measured and paid separately under relevant item of this BOQ’ (iv) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item (v) Rate deemed to be inclusive of securing the cables on HT/ LT side for tension free at cable entry box.
Disconnecting Primary/Secondary connection of transformer, 22000/11000 V, 3 Phase system and opening up the top cover of transformer of capacity 400 KVA for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bus rods including necessary soldering/jointing etc and after complete repair refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections complete all as specified and directed. Notes : (i) Major parts as under shall be measured and paid separately under appropriate item of this BOQ (iii) Dehydration/ filtration of transformer oil shall be measured and paid separately under relevant item of this BOQ’ (iv) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item (v) Rate deemed to be inclusive of securing the cables on Primary/ Secondary side for tension free at cable entry box.
Material and Labour for Replacement of HT bushing of transformer 11/0.433 KV of capacity 400 KVA complete all as specified and directed
All as per Sl item No. 9 here-in-before but capacity of 250 KVA.
All as per Sl item No. 9 here-in-before but capacity of 200 KVA.
All as per Sl item No. 9 here-in-before but capacity of 100 KVA.
Material and Labour Replacement of LT bushing of transformer 11/0.433 KV of capacity 400 KVA complete all as specified and directed.
All as per Sl item No. 13 here-in-before but capacity of 250 KVA.
All as per Sl item No. 13 here-in-before but capacity of 200 KVA.
All as per Sl item No. 13 here-in-before but capacity of 100 KVA.
Material and Labour for Replacement of HT bushing of transformer 22 / 11 KV of capacity 400 KVA complete all as specified and directed.
Material and Labour for Replacement of LT bushing of transformer 22 / 11 KV of capacity 400 KVA complete all as specified and directed.
Material and Labour for Replacement of silica gel breather of 22/11 KV Out door type transformer capacity 400 KVA complete all as specified and directed.
Material and Labour for Replacement of silica gel breather of 11000/433 V transformer of capacity 400 KVA complete all as specified and directed.
All as per Sl item No. 20 here-in-before but capacity of 100 to 250 KVA.
Material and Labour for Replacement of silica gel breather of 433/230 V transformer of capacity 50 KVA complete all as specified and directed.
Material and Labour for Replacement of silica gel standard type complete all as specified and directed.
Supply and fixing in repairs Dial type Temperature gauge 0 to 100 oC range complete with suitable to any make type and capacity of transformer complete all as specified and directed.
Supply and fixing Gun metal gate valve of 25 mm dia, ISI Marked suitable for oil inlet/outlet valves of transformer including taking down old one complete all as specified and directed.
Supply and fixing Gun metal gate valve of 40 mm dia, ISI Marked suitable for oil inlet/outlet valves of transformer including taking down old one complete all as specified and directed.
Taking down the defective unserviceable transformer, step down, 22000/11000 V, 3 phase system, out door type, 400 KVA from the PCC foundation inside the fencing with the help of man power & chain pully block or by crane etc including disconnecting all electrical and mechanical connections from the site and carrying to work shop for repair and replacement of old burnt unserviceabe items and taking back to the site after complete tesing including cost of transportation to and fro complete including meggaring, re- connecting HT cable end joint at Primary and Secondary side of the transformer and testing on no load and full load all as specified and directed. Notes : (i) Major parts as under shall be measured and paid separately under appropriate item of this BOQ (ii) Dehydration/ filtration of transformer oil shall be measured and paid separately under relevant item of this BOQ’ (iii) T&P including loading & unloading and minor parts like gasket kits etc... will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item (iv) Rate deemed to be inclusive of securing the cables on Primary/Secondary side for tension free at cable entry box
All as per Sl item No. 27 here-in-before but 11000/433 V, 3 phase, 4 wire system, out door type transformer, capacity from 400 to 100 KVA.
Material and Labour for winding HT coil with DPC or enamelled copper wire of existing size & guage winding wire for winding the transformer HT coil including insulating material complete all as specified and directed.
Material and Labour for LT coil winding with DPC or enamelled copper wire strip of existing size & guage winding for winding the transformer coil LT coil all as specified and directed.
Material and Labour for painting of transformer 22000/11000 V, 3 Phase system of capacity 400 KVA with two coats with synthetic enamel grey colour paint applied with spray gun complete including surface preparation complete all as specified and directed
Material and Labour for painting of transformer 11000/433 V, 3 Phase, 4 wire system of capacity 400 KVA with two coats with synthetic enamel grey colour paint applied with spray gun complete including surface preparation complete all as specified and directed
All as per Sl item No. 32 here-in-before but capacity of 100 to 250 KVA.
Material and Labour for painting of transformer 433/230 V, 3 Phase, 4 wire system capacity 50 KVA with two coats with synthetic enamel grey colour paint applied with spray gun complete including surface preparation complete all as specified and directed.
Material and Labour for outdoor type gang operated air break switch triple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with GI pipe medium grade, for current rating upto 400 Amps suitable for vertical mounting fixed type complete with 09 Nos HT insulators suitable for HT 22 KV including taking out old one complete all as specified and directed. Make: Jaipuria/Pactil/Atlas/BHEL/HEI/ELPRO/Southern Switchgear as approved by GE
Material and Labour for outdoor type gang operated air break switch triple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with GI pipe medium grade, for current rating upto 400 Amps suitable for vertical mounting fixed type complete with 09 Nos HT insulators suitable for HT 11 KV including taking out old one complete all as specified and directed. Make: Jaipuria/Pactil/Atlas/BHEL/HEI/ELPRO/Southern Switchgear as approved by GE
Material and Labour in repairs for HT Drop out fuse assembly of 22 KV current rating of 50 Amps with 2 post insulator per phase, double stack channel type including steel base mounting frame, MS nuts and bolts complete all as specified and directed.
Material and Labour in repairs for HT Drop out fuse assembly of 11 KV current rating of 50 Amps with 2 post insulator per phase, double stack channel type including steel base mounting frame, MS nuts and bolts complete all as specified and directed.
Material and Labour in repair for Single disc insulator, 22 KV with hardware fittings etc. complete all as specified and directed. Make: Jaipuria/Pactil/BHEL/MEI/Modern Insulators/Southern Insulators/Jayshree as approved by GE
Material and Labour for single disc type insulator, porcelain, vitreous, brown or white to suit HT 11 KV working pressure of size 145 mm height, 255 mm dia, ball and socket type including one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete including dismantling existing old insulator from position all as specified and directed. Make: Jaipuria/Pactil/BHEL/MEI/Modern Insulators/Southern Insulators/Jayshree as approved by GE
Material and Labour for pin type insulator, porcelain, vitreous, brown or white to suit HT 11 KV working pressure of size 150 mm height, 150 mm dia, including one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete including dismantling existing old insulator from position all as specified and directed. Make: Jaipuria/Pactil/BHEL/MEI/Modern Insulators/Southern Insulators/Jayshree as approved by GE
Supply and Fixing in repairs 22 KV/33 KV Lightning Arresters expulsion type complete with all fittings, transmission class discharge capacity 65 kilo Amps etc as required testing and commissioning complete all as directed Engineer-in-Charge. Make: Oblum/BHEL/Crompton & Greaves/Atlas/Jaipuria/GEC-ELPRO/AREVA T&D as approved by GE
Supply and Fixing in repairs 11 KV Lightning Arresters expulsion type complete with all fittings, transmission class discharge capacity 65 kilo Amps etc as required testing and commissioning complete all as specified and directed. Make: Oblum/BHEL/Crompton & Greaves/Atlas/Jaipuria/GEC-ELPRO/AREVA T&D as approved by GE
Material and Labour in repair for ACSR Conductor of weasel type for HT connection complete all as specified and directed. Make: ICC/NICCO/Bharat Conductors/Indian Aluminium Co/All-Ind as approved by GE
Material and labour for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT, 250 x 200 mm complete all as specified and directed.
Material and labour for preparation of old cement coated surface, cleaning the surface of the RCC HT pole above the ground level including coping area with two coats of acrylic exterior emulsion paint over a coat of cement primer after preparation of surface including 120 mm Navy blue synthetic enamel paint around the pole all as directed.
Material and labour for preparation of old painted surfaces of HT 2 pole structure, channels and clamps, section size up to 100 x 50 mm, clamps etc... and applying one coat of zinc chromium primer and two coats of aluminium paint for cross arms any numbers of each pole including clamps etc... all as specified and directed.
Material and labour for preparation of old painted surfaces of HT 4 pole structure, channels and clamps, section size up to 100 x 50 mm, clamps etc... and applying one coat of zinc chromium primer and two coats of aluminium paint for cross arms any numbers of each pole including clamps etc... all as specified and directed.
Material and labour for servicing of HT 11 KV VCB along with CTs/PTs of current rating upto 400 A, rupturing capacity 250/200 MVA of any make and type by drawing out breaker assembly from panel and carry out the following work complete all as specidfied and directed:- (i) Cleaning/ decarburizing of all fixed and moving contacts, levers, springs using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc, (ii) Adjust the trolley in and out mechanism , (iii) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, automatic shuttering system, necessary brazing, turning, polishing of main and auxiliary contact, demoisturing of insulators, etc to be done (iv) Testing of tripping performance of HT VCB by secondary current injection and testing of CT ratio and polarity, (v) Checking of tripping relay including interlocking if an25ements of the mechanical clearances of the operating mechanism, internal wiring circuit etc, tightening of all connections, replacement of HRC fuse, fuse carrier base (if any found u/s) including removing moisture deposit inside the VCB.
(vi) Checking all end terminals, Tighting the nut bolt and washers, replace the unserviceable nut, bolt & washers, draw-in the breaker, put in position, engage the VCB with the supply system and testing for smooth functioning. Notes : (i) The cost of cleaning materials, HT Tape, thinner, cotton waste, steel nut, bolt with double washers, HRC fuses, , fuse carrier base, shall deemed to be included in the quoted rate. (ii) Contractor shall isolate and earth the breaker before starting the work.
Supply and fixing, Closing Coil Assembly ( 24V/30V DC) as per existing size, type and suitable for 11 KV VCB including taking down old item complete all as specified and directed.
Supply and fixing ,of Tripping Coil Assembly ( 24V/30V DC) as per existing size, type and suitable for 11 KV VCB including taking down old item complete all as specified and directed.
Supply and fixing,of LED indicator of RED/GREEN/YELLOW/AMBER including taking down old materials ,complete all as specified and directed. Make : L&T / Siemens/AE/BCH/Vaishnav/C&S/ Kayce as approved by GE
Supply and fixing,of push button RED/GREEN/YELLOW/BLACK including taking down old materials complete all as specified and directed. Make : L&T / Siemens/AE/BCH/Vaishnav/C&S/ Kayce as approved by GE
Supply and fixing in repair of Digital Volt Meter of approximate size 96 x 96 mm in square shape, capacity 0 to 500 Volts complete all as specified and as directed. Make : L&T / Automatic Electric/Enercon/ Secure Meter/Legrand as approved by GE
Supply and fixing in repair of Digital Ammeter of approximate size 96 x 96 mm in square shape, capacity as per existing complete all as specified and as directed. Make : L&T / Automatic Electric/Enercon/ Secure Meter/Legrand as approved by GE
Material and labour for Calibration of protective relays both 02 Nos. over current and 01 No earth fault relay of IDMT or any other type by using relay injection kit including necessary adjustment of over current / earth fault / earth leakage by secondary current injection test along with testing and calibration of pickup current, time setting multiplier, tripping delay time, auto resetting of time, etc for successful operation at the time of fault occurrence as required according to the connected load and all as specified and directed.
Material and Labour for painting of the HT VCB of any make and type including PT enclosure, doors, etc... with synthetic enamel paint by spray painting system till the desired finish is obtained, after cleaning and preparation of old surface from dust, oil, rust and make the surface ready for painting all as directed. Note : (i) The rent of air compressor, T&P etc.. shall deemed to be included in the quoted rate. (ii) Contractor shall ensure the safety of the Painter/Electrician/Supervisor/Engineer while working on HT electric system at his own risk.
Excavation in trenches not exceeding 1.5 Meters wide and not exceeding 1.5 Meters deep in hard /dense soil for laying underground cables, laying pipes etc. complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in hard/ dense soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 metre and depositing at a level not exceeding 1.5 metre above the starting point all as specified and directed.
Supply and spread fine river sand in trenches for cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. Note: (i) Only punned thickness of river sand shall be measured (ii) Riddled earth shall be used in lieu of river sand after obtaining written permission from GE
Supply and lay burnt clay bricks, sub class "B", Designation 75, keeping the width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and laying unreinforced precast concrete cable covers, class HV, type- II flat size 300 x 180 x 40 mm complete all as specified and directed.
Taking down old burnout cable and Supply and laying, testing and commissioning of new HT 11KV XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), cable of size 3 core 185 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing including brass cable glands complete all as specified and directed.
All as per Sl item No. 64 here-in-before but of size 3 core 150 sqmm
Supply and fixing cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 185 sqmm x 3 core including taking down old item, complete all as specified and directed. Make: Birla 3M/ M-seal / Raychem / Denson / Yamuna Gases & Chemicals as approved by GE
Supply and fixing , cable jointing kit for 11 KV (Earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 185 sqmm x 3 core including taking down old item, complete all as specified and directed. Make: Birla 3M/ M-seal / Raychem / Denson / Yamuna Gases & Chemicals as approved by GE
Supply and fixing , cable jointing kit for 22 KV (Earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 185 sqmm x 3 core including taking down old item, complete all as specified and directed by Engr-in-charge. Make: Birla 3M/ M-seal / Raychem / Denson / Yamuna Gases & Chemicals as approved by GE
Taking out old earthing and Material and Labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically, earth pit not less than 2.25 meter deep below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including galvanised strip 25 x 4mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 5 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:3:6 type C1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary testing on completion all as specified and as directed. Note : (i) The unit rate shall also include for excavation, earth work in any type of soil,removal of surplus soil, PCC (1:3:6) type C1 for earth pit cover 6 Nos of 8mm dia CTD bar , RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete. (ii) Rate quoted is deemed to include for Earth continuity conductor and GI protection pipe upto7.5 meters.
Supply and fix in repairs, 11 kV/110 V Potential transformer Class 0.5 , Burden 100 VA , resin cast type with suitable mounting as per existing item in the site complete all as specified and directed.
Supply, fix and testing in repair of Power bank 230 V/24V DC with pack of minimum 15 numbers sealed maintenance free UPST100 VRLA batteries, neatly arranged in a rack and providing necessary connection for getting charged from line connected PT and to provide DC supply connected loads for operating close/trip coils and other essential loads such as auxillary supply to protection relays etc... complete all as specified and directed. Make: Exide/Amaron or equivalent as approved by GE
Supply and fix in repairs, high voltage insulating mats made of Elastomer conforming to IS - 15652-2006, of Size 3000 X 2000 X 3 mm thick (Class "C") complete all as specified and directed.
S KUMARAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .