Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC OLD SABZI MANDI PATHANKOT M S NORTHERN INDIA CONSTRUCTION CO DHANGU ROAD VILLAGE TOWN PATHANKOT CITY PATHANKOT PATHANKOT PUNJAB 145001 INDIA | PATHANKOT | PUNJAB | 145001 | ₹20.3 L Quoted ₹20.8 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹23.6 L+₹2.8 L (13.4%)Rejected-Finance | ₹23.6 L+₹2.8 L (13.4%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹24.9 L+₹4.1 L (19.9%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹24.9 L+₹4.1 L (19.9%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹29.8 L+₹9.0 L (43.2%)Rejected-Finance | ₹29.8 L+₹9.0 L (43.2%) | L4 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
14 Feb 2023, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
CERTAIN REPAIR REPLACEMENT MAINTENANCE OF LT PANEL UNDERGROUND CABLE LT POLE MISC WORK AT STATION HQ KANDRORI UNDER GE SOUTH PATHANKOT
2023_MES_573824_1
GES/PKT/T-65/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹60,000
Yes
6 Mar 2023
9 Jan 2023
16 Feb 2023
9 Jan 2023
14 Feb 2023
24 Jan 2023
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
All as per above item but exceeding depth 1.5 mtr and n exceeding 3 mtrs
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Same as per srl Item No. 7 above but of size 400 x 3.5 core
Same as per srl Item No. 7 above but of size 25 Sqmm 4 core
Same as per srl Item No. 7 above but of size 35 Sqmm 3.5 core
Same as per srl Item No. 7 above but of size 50 Sqmm 3.5 core
Same as per srl Item No. 7 above but of size 70 Sqmm 3.5 core
Same as per srl Item No. 7 above but of size 95 Sqmm 3.5 core
Same as per srl Item No. 7 above but of size 120 Sqmm 3.5 core
Same as per srl Item No. 7 above but of size 240 Sqmm 3.5 core
Supply and fixing PVC insulated copper conductor cable 16Sq mm x 3 core for main Panel to main switch/ starter,MCCB etc complete with thimbales of suitable size as required on site all including making connection all as specifed and directed by Engr-in-Charge
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 6 to 35 Sqmm 3.5/4 core with working voltage 1100 volts .
Material, labour , testing & commissioning of end jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 6 to 35 Sqmm 3.5/4 core with working voltage 1100 volts .
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like lamp, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
supply and fix in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels complete with contractor, connection strip, of capacity 63A. Make Indoashian, Legrand, HPL
Supply only the following spares suitable for LED street/Flood light fittings of
Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting
Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting
Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 90 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 70 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one.Make: Utkarsh Bansal/ National tubing Co/Jindal/Electrosteel. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
M & L for disconnecting burnt end or portion of UG Cable, removing the cable from loop including necessary excvation and earth work, relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminal for cable of cross sectional area 10 Sqmm 2 core to 95 Sqmm 3.5 core of LT cable to pole, main switch, LT Panel etc complete all as specified and as directed .
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 70 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
M & L for preparation of old painted surfaces of 09/11 m long steel poles incl removing oily/greasy sports and applying one coat of aluminium paint complete above 1.5 mtr and one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including applying a coat of white wash on pole cooping and lettering the pole details with white letters/black background etc complete all as directed
Supply & fixing in repairs of MCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc complete all as directed .
630 Amps, 4P, Adjustable type,415V MCCB, 35KA rating, with ICS =100%ICU Cat. Part No. 830391 of Indoasian or equivalent of make Schneider NSX LV432675, Legrand DPX3 422015 , All MCCB's should have Company Made Spreaders Links.
320-400 Amps, 3P, Adjustable type,415V MCCB, 35KA rating,with ICS =100%ICU Cat. Part No. 830391 of Indoasian or equivalent of make Schneider NSX LV432676, Legrand DPX3 422016 , All MCCB's should have Company Made Spreaders Links.
200-250 Amps, 3P,Adjustable type, 415 V MCCB, 25KA rating,with ICS =100%ICU Cat. Part No. 830292 of Indoasian or equivalent of make Schneider NSX LV431770, Legrand DPX3 420239 , All MCCB's should have Company Made Spreaders Links.
160-200Amps, 3P,Adjustable type, 415 V MCCB, 25KA rating, with ICS =100%ICU Cat. Part No. 830291 of Indoasian or equivalent of make Schneider NSX LV431140, Legrand DPX3 420238 , All MCCB's should have Company Made Spreaders Links.
125-160Amps, 3P,Adjustable type, 415 V MCCB, 25KA rating, with ICS =100%ICU Cat. Part No. 830290 of Indoasian or equivalent of make Schneider NSX LV430745, Legrand 420047 , All MCCB's should have Company Made Spreaders Links.
32 to 80 Amps, 3P, 415 V MCCB, 16KA rating, Cat. Part No. 830227 of Indoasian or equivalent of make Schneider NSX LV429551, Legrand 420004 , All MCCB's should have Company Made Spreaders Links.
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 35 KA, 320-400 A rated, with ICS =100%ICU Cat. Part No. 830396 of Indoasian or equivalent of make Schneider NSX LV432677, Legrand 422021 , All MCCB's should have Company Made Spreaders Links.
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 200-250 A rated, with ICS =100%ICUCat. Part No. 830297 of Indoasian or equivalent of make Schneider NSX LV431120, Legrand 420219 , All MCCB's should have Company Made Spreaders Links.
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 160-200 A rated, Cat. Part No. 830296 of Indoasian or equivalent of make Schneider NSX LV431121, Legrand 420218 , All MCCB's should have Company Made Spreaders Links.
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 125A to 160 A rated, with ICS =100%ICU Cat. Part No. 830295 of Indoasian or equivalent of make Schneider NSX LV430320, Legrand 420137 , All MCCB's should have Company Made Spreaders Links.
M & L for preparation of old painted surfaces of 09/11 m long PCC poles incl removing oily/greasy sports and applying one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including including applying a coat of white wash on pole cooping and lettering the pole details with white letters/black background etc complete all as directed
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor.
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 3 to 15 KVAR.
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 20 to 25 KVAR.
M&L in replacement of existing unserviceable cantactor of current carring range 25 A to 40 Amp (AC-3 duty) at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed .
M&L in replacement of existing unserviceable contactor current carring range 9 A to 18 Amp (AC-3 duty) at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed .Make schnieder/Havells/L&T.
M&L in replacement of existing unserviceable MCB 25-40 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed .
M&L in replacement of existing unserviceable MCB 32 - 63 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed .
Supply and fixing AC single phase 10-60A Net Meter DLMS compiance of accuracy class 1.0, 240V 50 Hz, with backlit LCD, Optical port (measures Import KWh, Export kWh, net kWh, V,I,kW, 6 month history of Energy), with Rs232 Port including dismatling of existing meter and deposting it yto MES store Yard, making all necessary input and output connection of the new energy meter. Complete ass as specified by Engr-in-charge.
Disconnecting the inlet/outlet water connections and electric connections of Storage storage type electric water heater of capacity 25 Ltrs capacity, taking down carefully from wall after unscrewing nut/bolts ,checking the outer body for any cracks and strip opening the same carefully for thorough inspection of serviceablity/functionality of parts such as internal tank, syphon assembly, thermostat switch, heating element, glass wool etc, servicing complete and re-assembling and re-fixing after repair,fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacemeny shall be measured and paid under relevant Schedule items of Sch here-in-after.
Supply only syphon assembly made out of SS of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as spd and directed for carrying out repairs under relevant item No.1.
Supply only thermostat switch ISI marked for storage type electric water heater AC 230 volt adjustable range from 0-90 degree Celsius ) for carrying out repairs under relevant item No.1
Supply only cup/triangular type storage type electric water heater element AC 230 volt, of rating 1500/2000 watt for carrying out repairs under relevant item No.1.
De-scaling of storage type electric water heater of capacity 25 ltr after taking down the storage type electric water heater from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation of storage type electric water heater complete all as directed by Engineer-in –Charge.
Replacement of spring loaded air release valve ISI marked suitable for 25 ltrs capacity storage type electric water heaters.
Replacement of safety valve / dead wt. valve ISI marked suitable for 25 Ltrs capacity storage type electric water heaters.
Supply and replace brass non return valve suitable for 25 ltr storage type electric water heater of size 15 mm.
Dismantling of Insulated hot water storage tank of capacity up to 500 Ltrs connected Solar Evacuated collectors/flat collectors and cold water tank with GI fittings & PVC pipe connection. Servicing,Testing, Commissioning & descaling of Hot water storage tank removing of corrosion/dust, replacement of UNSV PVC pipe after re-fixing the same.
Service and descaling of Solar Evacuated tube Collector/Flat collectors with sulphuric acid by forcefully injecting the hot chemical into collector for number of times to clean the Solar Solar Evacuated tube Collector/Flat Plate Collector and assembled the same.
S & F in replacement of Evacuated tube collector for Solar Water Heater of capacity Upup 500 LPD of suitabale size as per sample approved by Engineer -in-charge on the gound.
Replacement of heating element 2/3 KW suitable for stand by back up supply to solar water heater.
Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning of storage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed.(Note : Rate quoted deemds to be inclusive of anchor bolt, and pvc connetion)
Fixing only solar light with complete accessories of any size and capacity including irrection of the the pole providedf by the department into the ground up to 1 mtr detpth . The pole should be errected using pre cast cement concrete (1:4:8) type D2 using 40 mm graded stone aggregateat at depth not less than 01 mtr height with 0.5m width at the given site complete all as specified and directed by Ingr In charge. Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
Abrol construction co
M/S SATPAL & BROTHERS
M/s. Aggarwal Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .