Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAccepted-AOC | ₹7.7 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹8.3 Cr+₹59.1 L (7.64%)Rejected-Finance | ₹8.3 Cr+₹59.1 L (7.64%) | L2 | Rejected-Finance Not being L1 Bidder |
| 3 | L3₹8.4 Cr+₹62.6 L (8.09%)Rejected-Finance | ₹8.4 Cr+₹62.6 L (8.09%) | L3 | Rejected-Finance Not being L1 Bidder |
Tender Value
₹8.0 Cr
EMD Value
₹7.2 L
Closing Date
25 Jul 2023, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF BOUNDARY FENCING ALONGWITH ALLIED SERVICES AT DHANSIRIPAR NAGALAND UNDER GE AF JORHAT
2023_MES_573413_2
88633/JOR/E8
Open Tender
Civil Works
Lump-sum
700 days
GE AF JORHAT
As per NIT
8 documents required · 8 mandatory
₹3,000
GE AF JORHAT
₹7.2 L
Yes
8 Jan 2024
26 Jun 2023
27 Jul 2023
26 Jun 2023
25 Jul 2023
11 Jul 2023
Amount
NOTE (Applicable for all Parts/ Items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDING / STRUCTURE) (Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.)
Construction of Single Living Accn for 1 HAV and 10 Ors (Single storey) building,RCC framed structure , complete all as specified and as shown on drawings.
Construction of Guard Rest room (Single storey) building,RCC framed structure , complete all as specified and as shown on drawings.
Construction of Single Living Accn for JCO (Single storey) building,RCC framed structure , complete all as specified and as shown on drawings.
SCHEDULE 'A' PART- II ( SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- III (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- V (ROAD, PATH AND CULVERT) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VI ( COMPOUND WALL, FENCING AND GATE ) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VII (SEWAGE DISPOSAL AND AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- VIII (RETAINING WALL) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IX (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- X ( STANDBY POWER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART -XI (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES.
INTERNAL ELECTRIC SUPPLY S&F Energy efficient five star rated ceiling fan, 1400 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan including fan hook, clamp & fan box complete in all respect all as specified and directed.
S&F silent PVC exhaust fan of size 300mm sweep, copper wound 230 volts, 50 Hz, ISI marked with and including insertion of hume pipe section 300mm dia 200mm length for opening of exhaust fan and fixing of louvers connecting with wires from ceiling rose to exhaust fan & fixing in position with suitable arrangement complete all as specified and directed.
S&F LED light fittings 1 X 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Supply and fixing LED security light fitting 1 X 25 W with integral reflector made of aluminium alloy LM6, with LED driver etc and all accessories pre wired and making connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with bracket, complete all as specified and directed.
Supply and fixing TPN DB 415Volts 4 way with 100 Amps rated MCCB as incomer, copper busbar of suitable capacity double door on wall with and including suitable flat iron clamps duly grouted/fixed flush in the wall, complete with bracket, complete all as specified and directed.
S&F MCB single pole of capacity 6 to 32 amps, C-curve, 10 KA breaking capacity and making connection complete all as specified and directed.
S&F MCB single pole and neutral of capacity 32 amps, C-curve, 10 KA breaking capacity and making connection complete all as specified and directed.
S&F MCB single pole and neutral of capacity 40 amps, C-curve, 10 KA breaking capacity and making connection complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (medium grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (light grade) testing on completion complete all as specified and directed. [Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c) Excavation/earthwork is deemed to be included in the quoted rate.]
INTERNAL WATER SUPPLY Supplying and fixing brass angle stop cock CP high pressure with capstan head long shank screwed down 15mm dia bore, complete all as specified and directed.
COMPOUND WALL, FENCING AND GATE Supply and fixing chaink link fabric fencing Made of GI wire of dia 4mm, PVC coated to achieve outer dia not less than 5mm in required colour and shade of required width in mesh size 50 X 50 mm including strengthening with 2mm dia 6 Nos wire and nuts, bolts and washers as required, including GI wire 3.55 mm dia to be threaded through chain link mesh , complete all as specified and directed
Supplying and fixing concertina coil fencing with required dia 600 mm upto 3.00m height fixed existing iron 'Y' shaped placed 2.5 or 3.00 m apart and with 9 horizontal R, B, T stud tied with GI wire staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron complete as per direction of Engineer-in-Charge with reinforced barbed tape (RBT)/spring core(2.5mm thick) wire of high tensile strength of 165KG/Sqm with tape (0.52mm thick) , complete all as specified and directed
SEWAGE DISPOSAL Construction of LLDPE septic tank of capacity 2000 LTRs, with necessary strong basement with concrete as per manufecturer's instruction, complete all as specified and directed by Engineer -in-Charge. Note:- The cost of basement shall be deemded to be inclusive in quoted rate.
Construction of soakage well for 10 to 25 user, 1.60 mtr dia with effective depth as shown on drawings complete all as specified and as shown on drawings.
EXTERNAL WATER SUPPLY Supply, fixing, installing, commissioning and testing boosting Monoblock pump set of 1 HP self priming type, 25/25 mm delivery and suction, single phase, 240V 50Hz having discharge 52 LPM at 4m head fixed on PCC foundation including necessary cable connection, complete all as specified and directed
STANDBY POWER SUPPLY S&F of cubical housing cabinet type LT panel board OUT door type, platform mounted factory made. totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (3 15mm) thick CRCA MS Sheet of overall size 750 mm (height) x 750 mm(width) 350 mm (depth) and built upon suitable size angle iron frame work having front and rear hinged doors Gl earthing strips at rear side bottom detachable gland plate complete with suitable size zinc plated and passivated nut bolts , spring and washers .The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply powder coated paint (RAL-7032) The panel should be suitable for 415 volts 5OHz, 3 pnase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and compnsing following - BUS BAR CHAMBER (a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic gr ade high conductivity TP&N solid aluminium bus bars rated 100 amps supported at required intervals sleeved with heat shrinkable PVC sleevings The bars shall be colour coded at required intervals for identification - SET OF 4 -1 Nc
Material and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using copper earth strip 20 x 3 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipment/ panel/ test point at another end, earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles including excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No 3 of SSR Part I and testing on completion complete all as specified and directed.
DG SET Supply install testing and commissioning Silent type Diesel Engine DG Set 415 Volts, 20 KVA, 3 Phase 0.8 power factor, 50 Hz, 1500 RPM self ,excited self regulated brushless AC generator installed including acoustic enclosure suitable for ambient condition at Jorhat and confirmed to condition under ISO 3046 with capacity of 10% overloading for one hour in every twelve hour duration and alternator with following. Alternator:- Standard design alternator rated at 20 KVA at 0.8 (lag) power factor AC, 3-phase 4-wire 415 volts 50 Hz, 1500 RPM, self excited self regulated with an AVR, screen protected dnp proof brushless design with winding in pole faces, insulating class ‘H’ with IP-23 protections and voltage regulation of +1% at rated voltage from no load to full load. The alternator shall be in position to generate supply with frequency regulation with in + 1% tolerance. Tthe alternator will be suitable for tropical climate and shall generally confirm to BS 2613/5000/IS-4722 Diesel Engine: Adequate capacity of Diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection cold starting 1500 RPM as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-
(ITEM NO 11.20 ... Contd.../) (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class (s) Self starter (t) Electric operated electronic governor. (u) Fuel injection pump.
(ITEM NO 11.20... Contd.../) (i) Fly wheel with housing (ii) Cooling system- Moulded radiator with fan & belts (iii) Cooling water pump- Centrifugal type belt driven (iv) Exhaust System- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade Turbo charge type Exhaust manilold Silencer Residential type (v) Fuel System: Fuel injection system with fuel injectors fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed / frequency regulation (vi) Lub oil System (vii) Governer mechanical/ electronic type. Starting System- Electric Self starter with and including battery charging alternator 12 Volts DC Batteries – Batteries of capacity as per OEM's recommendations, complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill or electrolyte all as specified.
(ITEM NO 11.20... Contd.../) Control Panel: Control panel shall be fabricated from 16/14 SWG Sheet and powder coated after seven tank treatment process (a) Micro processor based generator set monitoring and control system consists of LCD display and to monitor operator interface, fault history, alternator data. Engine date, provision for service adjustment and calibration of DG control functions Engine controls, engineer protective functions, alternative protective functions etc. (b) Instrument fuses and control wing (c) Indication lamps for Set running and load on. (d) Bus bar including suitable capacity of MCCB/MCB including CTs, cable
(ITEM NO 11.20 ... Contd.../) Notes :- (a) Pre commissioning test shall be carried out by Testing Officer nominated by Accepting officer (b) Contracts shall provide one set of open jaw and ring spanner (c) Contractor shall provide one set of dies3el and oil filter and associated spares required for each service (d) Contractor shall provide engine oil as per OEM's recommendations required for each service (e) Contractor shall provide servicing of DG set till expiry of defect liability period
Supply and laying common burnt, clay building bricks, sub class 'B' designation over the sand cushioning in trenches for protection of cables (LT) complete all as specified and directed.
SRI BABUL NATH
Jasvit Constructions Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .