Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹48.4 L+₹56,195 (1.17%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹48.6 L+₹80,825 (1.69%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹48.9 L+₹1.1 L (2.33%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹49.0 L+₹1.1 L (2.39%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
29 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Deepak Kumar
GE Kapurthala
PROVN OF CERTAIN SANCTIONED WORKS AT MIL STN BEAS AND JANDIALA GURU UNDER GE KAPURTHALA
2021_MES_488151_1
GE KPT-49/2021-22
Open Tender
Civil Works
Item Rate
270 days
Kapurthala
As per tender documents
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹97,000
Yes
19 May 2022
13 Nov 2021
1 Dec 2021
13 Nov 2021
29 Nov 2021
20 Nov 2021
60 days
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving n.exc 15cm thickness (below or above ground level) etc complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters not exceeding 1.5 sqm each (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters exc 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.Complete all as specified and directed by Engineer-in-Charge.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar.Complete all as specified and directed by Engineer-in-Charge.
Dismantling mild steel work of any description complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5 m depth for foundation & getting out all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type D2, 1:4:8(40mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan exceeding 6m mean radious built in CM 1:6 etc complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 11 above but except bricks etc complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25cm for soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Spreading, leveling, watering and well ramming in layers not exceeding 25cm for soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed of a level not exceeding 1.5m above the starting point. Complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick cement concrete type C2 1:3:6 (40mm graded stone aggregate) in sub base. Complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick PCC 1:2:4 type B-1 with 20mm graded stone aggregate as in flooring, finished even and rough to receive the topping layer, complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick PCC 1:2:4 type B-2 with 40mm graded stone aggregate as in platform for urinal, finished even and rough to receive the topping layer. Complete all as specified and directed by Engineer-in-Charge.
Supply & lay sand as filling under floors or in foundations including watering and consolidation, complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of broken bricks of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-In-Charge.
M&L for 5mm thick Rendering in CM 1:3 on brick work or concrete surfaces on ceiling finished even and smooth without using extra cement etc, Complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick Rendering in CM 1:6 on brick work or concrete surfaces finished even and fair for fixing of wall tiles etc. Complete all as specified and directed by Engineer-In-Charge.
M&L preparation of Newly plastered surfaces and applying two coats of White Wash over and including a coat of chalk whiting/priming on plastered surfaces of walls etc. Complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of chalk whiting/priming on plastered surfaces of walls, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of Newly plastered surfaces and applying three coats of White Wash on ceiling etc. Complete all as specified and directed by Engineer-in-charge.
M&L for 40 mm thick Damp proof courses to horizontal or vertical surfaces in cement concrete 1:2:4, Type B-0 including necessary formwork, complete all as specified and directed by Engineer-in-Charge.
M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick cement screed base in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, treating the surface with bees wax polish, complete all as specified and directed by Engineer-In-Charge.
M&L for kota stone slab 20-25mm thick in riser of steps, skirtings, dado and pillar, laid over and including 15mm thick cement screed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, treating the surface with bees wax polish, complete all as specified and directed by Engineer-In-Charge.
M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in plinth protection finished even and smooth (without using extra cement), complete all as specified and directed by Engineer-In-Charge.
M&L for providing cement concrete cast in situ Type B-1, 1:2:4 ( 20 mm graded stone aggregate) as in lintels upto 1.5m clear span including necessary formwork complete all as specified and directed by engr in charge.(Note : Reinforcement shall be measured and paid separately)
M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded stone aggregate) as in chajjas, complete all as specified and directed by Engineer-in-Charge.
Use and waste for formwork to chullah hoods, Chajjas, troughs and similar items including edges, complete all as specified and directed by Engineer-in-Charge.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to. Complete all as specified and directed by Engineer-In-Charge.
-Ditto- all as per item No 36 above but 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders. Complete all as specified and directed by Engineer-In-Charge.
S&F rolled sections Fe-410-W(Gde E-250) quality-A, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates . Complete all as specified and directed by Engineer-In-Charge.
S&F Roof truss/Framed works as in purlins, crane gantries, rails and fastening and heavy brackets framing Beam (of tee,angle, pipes of flat section , base plates etc) including distance pieces. Complete all as specified and directed by Engineer-in-charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer-In-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-In-Charge.
S&F Wind tie for roof including securing bolts: flat iron fillets including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe 410-0 or Fe 310-0 etc. Complete all as specified and directed by Engineer-In-Charge.
M&L for framed work as in doors or gates and chowkhats of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening conforming to GdeFe 290(Gde E-165). Complete all as specified and directed by Engineer-In-Charge.
S&F 2nd class hard wood 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer-In-Charge.
S&F 2nd class HW 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. Complete all as specified and directed by Engineer-in-charge.
S&F Mild steel pressed handles of size 150mm, oval type, stove enamelled black, complete all as specified and directed by Engineer-In-Charge.
S&F Mild steel barrel tower bolts 200mm long, stove enamelled black, with bright bolt and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F Butt hinges 100mm size, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F Mild steel sliding door bolts 250mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 250mm complete all as specified and directed by Engineer-In-Charge.
S&F MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-In-Charge.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overlength of cover plate 150mm complete all as specified and directed by Engineer-In-Charge.
S&F Aluminium anodised barrel tower bolts of extruded section of 125mm size etc complete all as specified and directed by Engineer-In-Charge.
S&F Aluminium handles, cast type anodised of size 125mm etc. Complete all as specified and directed by Engineer-in-charge.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm, 1.25 thick sheet single rebated comprises glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T-section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:2:4) type B-1 Four Nos for each window including following fitting welded to frame shutter : (a) Hold fast, 150mm long of 12mm square bar made to shape-04 Nos per window (b) Handles of z section 100mm long (c) Stopper - 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mm x 63mm welded to hinges - 01 No per leaf (e) MS Pintal hinges of size 75mm x 75mm x 12mm-02 Nos per leaf (f) (f) Grills made out of MS square bar 12mm dia welded to FI frame complete, Fabrication & fixing arrangement as per drg No CEJZ/TD-7/07 sheet 1/3 to 3/3. Note : Glass and painting shall be measured and paid separately under appropriate item etc. Complete all as specified and directed by Engineer-in-charge.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm, single rebated comprises gauzed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T-section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:3:6) type C-1 Four Nos for each window including following fitting welded to frame shutter : (a) Mild Steel Hold fast, 150mm long of 12mm square bar made to shape-04 Nos per window (b) Handles of z section 20mm x 100mm long (c) Stopper - 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mm x 63mm welded to hinges - 01 No per leaf (e) MS Pintal hinges of size 75mm x 75mm x 12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note : Wire mesh and painting shall be measured and paid separately under appropriate item etc. Complete all as specified and directed by Engineer-in-charge.
S&F Steel Ventilator 1.25mm thick Box Type fixed type prepared for fixing of gauzed and glass ( primer coated) ERW hollow P section of size 60mm x 25mm including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each vent ) including following fitting welded to frame shutter: (a) Mild Steel Hold Fast,150mm long of 12mm Square bar made to shape – 04 Nos per vent (b) Handles of Z Sec 20mm x 100mm long (c) Stay (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note: Wire mesh/glass pane and painting shall be measured and paid separately under appropriate item etc. Complete all as specified and directed by Engineer-in-charge.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples, beads to steel windows/wodden doors.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge.
All asper item No 60 above , but over and including a coat of red oxide primer. Complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new wood surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6. Complete all as specified and directed by Engineer-in-charge.
M&L for Glazed ceramic coloured tiles in vertical surface 300x200x 7 mm thick laid over and including 10mm thick screed bed in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed by engr-in-charge.
S&F 3.2/3.3mm thick linoleum sheet,plain coloured,laid dry in floors including stretching,cutting and fitting and sealed down with an approved adhesive. Complete all as specified and directed by Engineer-in-Charge.
Dismantling of Brick tiles or terracing tiles, single layer on roofs all as specified and directed by Engineer - in - Charge .
Demloition of Mud on roof , any thickness , including plastering and leeping (whether full thickness removed or a part thereof. Complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4, type B-1 (using 20 mm garded stone aggregate), padding average 75mm thick to be provided in slope including roughening surfaces of old/concrete floor by backing sweeping clean and washing down with water etc and over & including 20 mm thick screed in CM 1:4, using WPC, and APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application, over a coat of hot blown bitumen 85/25 @ 1.20 kg/Sqm and Apply two coat of alumnium paint on top of membrane surface after laying the membrane incl all cleaning complete all as specified and direced by Engineer-In-Charge.(Note:-Before taking up roof treatment ,RCC roof slab shall be tested by ponding with 25mm height of water for 72 hours).
M&L 40 mm thick brick tiles laid on mud mortar and joints grouted flush in CM 1:3 mixed with 5% of crude oil by weight of cement on mud phuska and 20 mm thick screed bed and bedding layer of CM 1:6. Complete all as specified and directed by Engineer-in-Charge.
M&L for dubbing out average 10mm thick on disturbed chajja beam portion and applying chilken wire mess over disturbed portion fixed with drilling bolting etc.after anti corrison treatment of steel bar and finaly finished with 1:3 cement plaster 10mm thick mixed with WPC @ 3%by the weight of cement. Complete all as specified and directed by Engineer-in-Charge.
S&F vitreous chaina squatting pan (Orissa pattern), size 580 x 440mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding. Complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device with recessed bottom, jet spray, etc as in repairs. Complete all as specified and directed by Engineer-in-Charge.
S&F Low Level Flushing System PVC valveless syphonic action type, 10 ltrs capacity including supply pipe & fixing brackets of M.S. angle of size (25mmx25mmx3mm), 30 cm long in PCC (1:2:4) type B-1, block of size (10cmx10cmx10cm) on walls, etc. Complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China Wash Basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or eracting stand & waste pipe, coupling etc. Complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china bowl urinal flat back, size of 465 x 355 x 265mm white with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. Complete all as specified and directed by Engineer-in-Charge.
S&F 15mm dia Chromium plated fancy type bib tap cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe and fixed to 15mm bore pipe fixed. Complete all as specified and directed by Engineer-In-Charge.
Supply only 15mm dia fancy type Pillar taps, cast copper alloy with capstan heads Chromium Plated, screwed down high pressure, with or without lettered with long screwed shanks and fly-nuts, screwed for iron pipe but fancy type etc. Complete all as specified and directed by Engineer-In-Charge. Note : fixing charges included in item No 74 above.
S&F angle stop valve of PTMT any colour pressure screwed for iron pipe and fixed (minimum weight 15mm - 90 gms). Complete all as specified and directed by Engineer-in-Charge.
S&F grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gms) etc. Complete all as specified and directed by Engineer-in-Charge.
S&F PVC connection 15mm size with PTMT nuts of length 450mm etc. Complete all as specified and directed by Engineer-In-Charge.
S&F Steel Tubes Medium Grade Bore of tube in 15mm galavanised with all fitting laid in trenches, walls, ceiling or laid in floors etc. Complete all as specified and directed by Engineer-in-Charge.
All as per item No 81 above but of size of 20mm bore. Complete all as specified and directed by Engineer-in-Charge.
S&F Rotational moulded polyethylene water storage tanks of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified including 15m dia brass float valve complete all as specified and directed by Engineer-in-charge.
S&F Rotational moulded polyethylene water storage tanks of capacity 1000 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified including 20mm dia brass float valve complete all as specified and directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors. Complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls as a vent pipe. Complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) bends any radius. Complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) bends any radius provided with access door. Complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal . Complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal provided with access door. Complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) vent cowl. Complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) P trap 100/110mm bore. Complete all as specified and directed by Engineer-in-Charge.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement. Complete all as specified and directed by Engineer-in-Charge.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to steel pipe or union, 15mm bore dia of pipe. Complete all as specified and directed by Engineer-in-Charge.
Ditto all as per item No 95 above but 20mm bore dia of pipe. Complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC Door Frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube and fixing in opening as per specification & drawing given in SSR 2020 (Part-II). Etc. Complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width & stuck inside with solvent cement for stile and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing given in SSR 2020 etc. Complete all as specified and directed by Engineer-in-Charge.
Supply & fix anodised aluminium snap grid frame work of size 605 x 605 mm with aluminium T section of size 38x25x1.5mm thick for main runner, 25x25x1.5mm thick for cross runners and angle of size 25x25x1.5mm thick along the walls suspended with & including 4mm dia galvanised mild steel wire (as in suspenders of ceiling members) for false ceiling including necessary notching & prepared holes. Complete all as specified and directed by Engineer-in-Charge.
Supply & fix 8 mm thick gypsum board laminated on both sides for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid. Complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-In-Charge.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal/sloping), fair finished surfaces concrete flat, complete all as specified and directed by Engineer-In-Charge.
M&L for PCC 1:2:4 Type B-1 ( 20 mm graded stone aggregate) as in bed blocks, coping, etc. Complete all as specified and directed by Engineer-In-Charge.
Surface excavation not exceeding 30cm deep and avg 15cm deep and getting out in hard/dense soil. Complete all as specified and directed by Engineer-In-Charge.
M&L for Machine pressed precast concrete interlocking paver block, 80mm thick, any shape and size, confirming to IS-15658-2006, M-40 Grade, with grey cement and no pigment. Complete all as specified and directed by Engineer-in-Charge.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over & including 20mm thick screed bed in cement mortar 1:6 and pointed in white or colour cement to match. Complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges. Complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type B-1, 1:2:4 (20mm graded stone aggregate as in surface channels and drains. Complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan exceeding 6m mean radious built in CM 1:4 etc complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces with liquid water proofing compound,finished even and smooth without using extra cement etc including neeru finish to plastering complete all as specified and directed by Engineer-in-Charge. (Note : Liquid water proofing compound shall be measured and paid separately).
M&L for Cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in bed to drain pipe including packing under and haunching against the sides of pipes 150mm dia (internal) after pipes are laid in trenches. Complete all as specified and directed by Engineer-in-Charge.
Supply & lay 150mm bore reinforced concrete pipes, class NP3, laid and jointed in cement joint complete with collars,complete all as specified and directed by Engineer-in-Charge.
M&L for precast cement concrete type B-1, 1:2:4 as in cover slabs over drain/manholes etc. including necessary formwork. Complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finshed drain or channel 30 cm inner girth in cement concrete, using extra cement , including forms , moulds, mitred/stopped ends etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for construction of sokage well complete including excavation, in any type of soil, foundation in PCC 1:3:6, wells of honeycombed masonary with top ring of M-25 Concrete, including intercepting chamber and screen chamber brick work in CM, RCC (with TMT 12mm dia reinforcement) cover slab in M-25/SFRC cover, interconnecting pipe of RCC/DWC complete filled with brick bats, complete of size 1.8m dia X 3m effective depth. Complete all as specified and directed by Engineer-in-Charge.
M&L for construction of soakage wells complete including excavation in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC (with TMT 12mm dia reinforcement) cover slab in M-25/ RR masonry / Filling with brick bats, complete of size 1.2 M dia X 3.0M deep. Complete all as specified and directed by Engineer-in-Charge.
On site Hume pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 as below foundation, vent shaft, connection etc. complete for 10 users, complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable carefully point wiring on casing caping/through conduit (light fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, regulators, box type tube light fittings, removing the materials from site except fittings etc which shall be reused in the work and making good the disturbed surfaces of walls/ceiling/ floors etc complete all as specified and as directed by Engineer-in-Charge
M&L for point wiring for one light or one fan point controlled by one switch or with one switch and regulator with PVC unsheathed single core multistranded copper conductor (FRLS) cable of size 1.5 Sqmm (nominal area) in and including PVC conduit 20 mm bore by cutting chases in wall by cutter and making good the surface in cm 1:3 and to the original specification and cast iron /pressed steel concealed terminal boxes including providing 3mm thick plastic laminated sheet cover (Hylem) including one run of PVC insulated copper conductor (FRLS) cable of size 1.5 sqmm with green insulation as earth wire and connected to earth dolly complete all as specified. (Switch/Socket outlet to be measured & paid for separately). Make of cable: Finolex/Anchor/Havell’s
All as per Srl item No 119 here in before but for 3 pin socket outlet 5 Amps on same board. Complete all as specified and as directed by Engineer-in-Charge.
All as per ser item 119 above but for 3 pin socket out let 5 Amps on independent board.Complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 119 here in before but for 3 pin socket outlet 15 Amps on independent board with PVC unsheathed copper conductor cable of size 2.50 Sqmm including copper earth wire of size 1.50 Sqmm and connected to common earth dolly complete all as specified. (Switch/socket to be measured & paid for separately)
Supply & fixing switch piano flush type 5 Amp single pole one way. ( Make-Anchor/SSK/Bajaj/Cona/ Kinjal). Complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing switch piano flush type 15 Amp single pole one way. Complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing socket outlet 5 pin 5 Amps flush type multipurpose. ( Make-Anchor/SSK/Bajaj/Cona/ Kinjal). Complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing socket outlet multipurpose 2 in one, 3 pin 5/15Amps flush type. Complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing ceiling rose surface bakelite 65 x 50mm three terminal complete all as specified and as directed by Engineer-in-Charge. Make – Anchor/Leader/Bajaj
Supply & fixing Angular lamp holder insulated body with back plate suitable for batten fittings including 1 x 9 W LED Lamp Make- Havells LED ADORE 9 W B22 WW 3 STAR LAMP Cat No LHLDEUEEMC8R009 or equivalent all as specified and directed by Engr in Charge.
S&F surface mounting energy saving LED tube light fitting, 1x20W, 230V , high efficiency PMMA diffuser gives soft glare free light with LED tube rode 20 W (White) complete with all accessories. Make : Crompton/Philips/Bajaj/Wipro/Surya. Complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix Metallic exhaust fan 300 mm sweep, 240 Volts Colour- Grey Make- Crompton Model Transair 6" single phase ,230/240 V,AC including making of hole on wall for passing out air and provision of flexible three core copper conductor cable of 23/0.0076 up from ceiling rose to fan and grouting 04 Nos bolts in wall. Complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix Metallic exhaust fan 450 mm sweep, 240 Volts Colour- Grey Make- Crompton Model Transair 6" single phase ,230/240 V,AC including making of hole on wall for passing out air and provision of flexible three core copper conductor cable of 23/0.0076 up from ceiling rose to fan and grouting 04 Nos bolts in wall. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Water heater storage type, electric,capacity 50 litres. BEE 5 star rated Make - Bajaj/Racold/Havells/Crompton. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing PVC connection cold water pipe 18" long, 15mm dia with brass jem nut and wahser, both side complete all as specified and directed by Engineer-in-Charge.
All as per ser item No 133 here in before but hot water pipe made of chromium plated brass flexible tubing. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB single pole 6 to 32 Amps 240 Volts. . ( Make-Havells/GE/L &T/Legrand). Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB SPN 40 Amp 240 volt, complete. ( Make-Havells/GE/L&T/Legrand). Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing MCB, 4P, 415 Volts of capacity 63 Amps, 10 KA. Complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosures DB Single Pole and Neutral 8 way with double door, detachable gland plates flush/ mounting for MCB’s fitted with bus bar, earth wire, 220 volts including taking down of existing DB at site all as specifed and directed.. Make-Havells/L&T/Legrand.
S&F sheet metal enclosures with double door, detachable gland plates flush/ mounting for MCB’s fitted with bus bar, earth wire and neutral link,SPN 12 ways, 240 volts. ( Make- Havells/Legrand). Complete all as specified and as directed by Engineer-in-Charge.
M&L of earthing complete with galvanized steel earth plate trode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level connected to GI earth wire 4mm dia by means of bolts, nuts and washers (earth plate covered with charcoal dust and common salt in alternate layers) GI earth wire protected by galvanized steel pipe light grade of 15 mm dia upto switch board and connected to main switch board, including provision of 20mm dia GI tubing light grade watering pipe with funnel and wire mesh PCC earth pit (1:3:6) type C-1 covered with CI cover hinged with frame including excavation and earth work complete all as specified and shown in electrical plate No 5 of SSR Part I including testing on completion. Complete all as specified and as directed by Engineer-in-Charge.
Earthing with copper Earth Plate Electrode 300x300x3mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Copper Earth Strip of size 25x6 mm by means of Bolts, Nuts, Check Nuts and Washers of copper and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-Charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm dia copper strip. Complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete with 1.5 sqmm single core multi stranded copper conductor FRLS PVC insulated but unsheathed cable 1100 volts grade drawn throughand including rigid steel ERW conduit of 25mm dia (external) heavy duty including necessay flame proof /weather proof conduit accessories and fitting concealed in wall/ceiling etc including sealing threaded jointsin conduit accessories with teflon tape,flame proof sunken type pressed steel terminal boxes with bakelite sheet of approved shade 3.0 mm thick including 1.5 sqmm single core FRLS PVC insulated but unsheathed multistranded copper conductor cable as in continuous earth.Wiring shall be suitable for flame proof area as per STEC-7 for the followings:-
One flame proof light / fan point controlled by one,single pole flame proof switch
Two flame proof light point controlled by one,single pole flame proof switch
All as per srl item No 143 above but for 3 pin socket outlet 15 Amps on independent board with PVC unsheathed copper conductor cable of size 2.50 Sqmm including copper earth wire of size 1.50 Sqmm and connected to common earth dolly complete all as specified. (Switch/socket to be measured & paid for separately)
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A,250V, 2P+ earth. Complete all as specified and as directed by Engineer-in-Charge.
Flame proof and weather proof rotary type switch,16 Amps,230 Volts,AC single pole, (LM-6) aluminium alloywith flame proof cable entry glands CMRS certified,ISI marked rotary type switch shall be CAT .SSPL/RI/1010 of Shyam or equivalent model of SUDHIR/FLEXPRO/BALIGA make)
Flame proof and weather proof ceiling fan, 1200 mm ,230 Volts,AC (LM-6) with flame proof cable entry glands CMRS certified,ISI marked . Make UDHIR/FLEXPRO/BALIGA make)
Supply and fix Junction box dia 120 x 70H
Sub main wiring with two runs of PVC insulated but unsheathed multistranded copper conductor FRLS cable 4 sqmm single core 1100 volts grade drawn through and including rigid steel ERW conduit of 25mm dia (external) heavy duty including necessay flame proof /weather proof conduit accessories and 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade as earth wire complete. (Note:- Two runs of cable with one run of conduict & one run of cable as earth wire shall be measured & paid for as one length for payment.)
Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size and connector block etc complete with flexible steel conduit with flame proof cable entry galands all as specified and directed.
S&F factory made flame proof distribution board TPN,4 way,440 Volts,50 Hz made of aluminium alloy LM-6,in high tensile steel CMRS approved comprising comprising of following: Make : SHYAAM/ SUDHIR/FLEXPRO/BALIGA)
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for ltaking out old cable/laying of under ground cable/foundation of poles/stays including segregation of old serviceable bricks complete all as specified and directed by Engineer-in-Charge.
Supply & Lay bricks as brick protection using old size sub class 'B' bricks, laid flat dry but adjoining to each other laid lengh wise perpendicular to the axis of cable complete all as specified and directed.
Supplying, filling in trenches spreading, leveling sand cushioning 8 cm below and 15 cm above the cable for under ground cable complete all as specified & directed . Note : 18 cm thickness after punning shall be measured, recorded & paid.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable 1100 volt grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete.
Supply and fixing LED bldg security light fitting 20 watt Powder coated pressure die cast aluminium compact LED security light including 1.5 mtr long 40 mm bore GI pipe mounting bracket made to shape for fixing on wall with 40 mm x 6 mm flat iron clamp 02 numbers with 16 mm dia bolts, nuts and washers all as specified and directed by Engineer-in-Charge.Make- Crompton, Product Code -LSTS-20-CDL-M or equivalent in Bajaj/Philips/Polycab /Havells: Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
M&L for GI Pipe 'light grade' galvanized with all fitting laid in trenches/on pole/road crossing of size 50mm
Cutting the existing 40/50mm dia GI/CI pipe line for insertion and including of suitable tee, jointing material, excavation and earth work etc.
Supply and fixing to wall and ceiling pipe galvanised medium grade 20 mm bore including fittings as directed.
Supply and lay in trenches pipe galvanised medium grade 25mm bore including fittings as directed.
Supply and fixing to wall and ceiling pipe galvanised medium grade 25 mm bore including fittings as directed.
Supply and fixing Gun-metal, globe or gate valves, 25 mm with iron wheel head, screwed both ends for iron pipe and fixed
Supply and fixing ball brass valves, high pressure, with polythene float and nut complete size 20mm .
Harbhajan electric co
KAMAL AGGARWAL
Gurjit const co
COSMO BUILDERS
Motorway Constructions
VISHWAMITRA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .