Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC | ₹47.0 L Quoted ₹49.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹49.2 L+₹26,244 (0.54%)Rejected-Finance | ₹49.2 L+₹26,244 (0.54%) | L2 | Rejected-Finance Higher bid value |
| 3 | L3₹49.9 L+₹97,718 (2.00%)Rejected-Finance | ₹49.9 L+₹97,718 (2.00%) | L3 | Rejected-Finance Higher bid value |
| 4 | L4₹50.0 L+₹1.0 L (2.07%)Rejected-Finance | ₹50.0 L+₹1.0 L (2.07%) | L4 | Rejected-Finance Higher bid value |
| 5 | L5₹50.6 L+₹1.6 L (3.27%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | ₹50.6 L+₹1.6 L (3.27%) | L5 | Rejected-Finance Higher bid value |
| Sl No | Description | Qty | Unit | SANJAY KAUSHIK L1 | GEETA CONSTRUCTION L2 | BIJAY MITTAL L3 | RAAJ BANGAR L7 | KAMLESH ENTERPRISE L6 | DHARMINDER SINGH L9 | M/S ANIL KUMAR THAKUR L4 | M/S S. S CHETTRI AND SONS L5 | MAHENDRA KHAWAS L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for construction of brick masonry valve pit of size 1200 mm x 1200 mm x 1200 mm (internal dimensions) with brick work in cement mortar (1:4) including excavation and earth work complete with 3 mm thick MS sheet cover and MS angle 40 x 40 x 6 mmwith locking arrangement, hinges and handle , rendering work, painting to all steel surfaces with two coats of synthetic enamelled paint (1st grade quality) over a coat of red oxide primer, complete as specified and as directed. | 2 | EACH | 29,350 ₹58,700 | 29,497 ₹58,994 | 29,950 ₹59,900 | 30,000 ₹60,000 | 29,750 ₹59,500 | 27,250 ₹54,500 Lowest | 29,965 ₹59,930 | 30,000 ₹60,000 | 29,990 ₹59,980 |
| 2.00 | Supply, installation, testing and commissioning of electric driven Booster Pump to deliver 900 LPM flowrate at 36 mWC head and suitable for automatic operation and consisting of following, complete with accessories all as specified and directed by the engineer-in-charge.
[i] Horizontal type, centrifugal, split-casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal, etc. conforming to IS 12469: 2019, suitable to deliver 900 LPM flowrate at 36 MWC head.
[ii] Suitable HP squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, having IE3 efficiency and suitable for operation on 3- Ph, 415 V, 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class 'F' insulation, conforming to IS 12615: 2018.
[iii] MS fabricated common base-plate, coupling, coupling guard, foundation bolts, etc. complete with accessories as required.
[iv] Suitable cement concrete foundation duly plastered with anti vibration pads | 2 | EACH | 1,50,000 ₹3,00,000 | 1,51,720 ₹3,03,440 | 1,47,000 ₹2,94,000 | 1,48,000 ₹2,96,000 | 1,50,000 ₹3,00,000 | 1,44,750 ₹2,89,500 Lowest | 1,47,000 ₹2,94,000 | 1,45,000 ₹2,90,000 | 1,46,990 ₹2,93,980 |
| 2.01NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. [v] Installation, testing and commissioning of the fire pump shall conform to IS15301: 2003 or NFPA 20. | ||||||||||||
| 3.00 | S & Fof Pressure Gauge suitable for 0-14 kg pressure range with 4" dial, die cast aluminium body with white background & black marking, 1/2" Male NPT threaded connection, suitable to work in service temp. of -20 °C to 80 °C having accuracy of ± 1 % FSD assembled with ball valve, nipple, socket, etc. for pump suction & delivery lines of fire pump sets near the flow switches all complete as specified and directed by the engineer-in-charge. | 2 | EACH | 2,500 ₹5,000 Lowest | 2,513 ₹5,026 | 2,500 ₹5,000 Lowest | 2,570 ₹5,140 | 2,610 ₹5,220 | 2,725 ₹5,450 | 2,600 ₹5,200 | 2,500 ₹5,000 Lowest | 2,560 ₹5,120 |
| 4.00 | M & L for 1.1 kV grade 3 core, 6 mm2 copper conductor, XLPE insulated armoured cable conforming to IS 7098-1: 1988, having stranded aluminium compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath,single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by the engineer-incharge. | 300 | RM | 900 ₹2,70,000 | 905 ₹2,71,500 | 915 ₹2,74,500 | 950 ₹2,85,000 | 900 ₹2,70,000 | 875 ₹2,62,500 Lowest | 975 ₹2,92,500 | 900 ₹2,70,000 | 930 ₹2,79,000 |
| 5.00 | M & L for 80mm NB (ISI marked) MS ERW Pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer,including supporting / fixing the pipe on floor / wall / ceiling with clamps, hangers,angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint (1st grade quality) complete all as specified and directed by the engineer-in-charge.
NOTES:
[i] Standard MS fittings with welded joint shall be used on the pipes.
[ii] All hangers, clamps, brackets etc. shall be of galvenized iron.
[iii] Welding of any kind on galvenised support / hanger shall not be permitted.
[iv] The pipe size 150 mm NB & below shall be MS 'C' class as per IS 1239-1:
2004 & IS 1239-2: 2011.
[v] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS 3589: 2001
[vi] Pipes of size more than 50 mm NB shall be butt welded with fittings of equal or higher thickness whereas pipes below 50 mm NB size shall be socket welded. | 220 | RM | 1,091 ₹2,40,020 Lowest | 1,096 ₹2,41,120 | 1,115 ₹2,45,300 | 1,250 ₹2,75,000 | 1,212 ₹2,66,640 | 1,250 ₹2,75,000 | 1,130 ₹2,48,600 | 1,100 ₹2,42,000 | 1,120 ₹2,46,400 |
| 6.00 | All as per item Ser No 5.00 here-in-above but 50 mm NB | 150 | RM | 770 ₹1,15,500 Lowest | 774 ₹1,16,100 | 780 ₹1,17,000 | 850 ₹1,27,500 | 788 ₹1,18,200 | 820 ₹1,23,000 | 793 ₹1,18,950 | 800 ₹1,20,000 | 800 ₹1,20,000 |
| 7.00 | All as per item Ser No 5.00 here-in-above but 25 mm NB | 120 | RM | 399 ₹47,880 Lowest | 401 ₹48,120 | 415 ₹49,800 | 425 ₹51,000 | 410 ₹49,200 | 450 ₹54,000 | 425 ₹51,000 | 400 ₹48,000 | 500 ₹60,000 |
| 8.00 | Supply and fix Valves, Sluice, flanged of class 1.6 PN ,80 mm (4”) dia | 2 | EACH | 15,200 ₹30,400 | 15,276 ₹30,552 | 15,510 ₹31,020 | 15,600 ₹31,200 | 16,000 ₹32,000 | 14,900 ₹29,800 Lowest | 15,560 ₹31,120 | 15,000 ₹30,000 | 15,600 ₹31,200 |
| 9.00 | M & L for PN 1.6 rated air vent valve having brass body, cover, adopter, disc assembly & cap, stainless steel strainer, plastic float and 25 mm screwed threaded ends suitable for maximum operating temperature 100 °C installed on all high points in the water piping system to automatically remove the trapped air with necessary accessories all complete as specified and directed by the engineer-in-charge. | 16 | EACH | 2,000 ₹32,000 Lowest | 2,010 ₹32,160 | 2,050 ₹32,800 | 2,050 ₹32,800 | 2,025 ₹32,400 | 2,350 ₹37,600 | 2,100 ₹33,600 | 2,100 ₹33,600 | 2,080 ₹33,280 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Aug 2025, 6:00 pmClosed
GE Gangtok
GE Gangtok New Mil Stn Gangtok Sikkim- 737102
REPAIR MAINT OF CERTAIN FIRE FIGHTING WORKS AT EM INSTALLATION AND SUB STATION AND AC PLANTS COOLING APPLIANCES HEATING PLANT AND COMPREHENSIVE MAINT OF VRF TYPE INCLUDING AMC AT JADC BLDG AND CONNECTED ACCESSOREIS UNDER GE GANGTOK
2025_MES_723627_1
8368/A//E8
Open Tender
Miscellaneous Works
Works
243 days
GE Gangtok New Mil Stn Gangtok Sikkim
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
₹90,000
Yes
14 Oct 2025
31 Jul 2025
23 Aug 2025
31 Jul 2025
21 Aug 2025
14 Aug 2025
Amount
M&L for construction of brick masonry valve pit of size 1200 mm x 1200 mm x 1200 mm (internal dimensions) with brick work in cement mortar (1:4) including excavation and earth work complete with 3 mm thick MS sheet cover and MS angle 40 x 40 x 6 mmwith locking arrangement, hinges and handle , rendering work, painting to all steel surfaces with two coats of synthetic enamelled paint (1st grade quality) over a coat of red oxide primer, complete as specified and as directed.
Supply, installation, testing and commissioning of electric driven Booster Pump to deliver 900 LPM flowrate at 36 mWC head and suitable for automatic operation and consisting of following, complete with accessories all as specified and directed by the engineer-in-charge. [i] Horizontal type, centrifugal, split-casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal, etc. conforming to IS 12469: 2019, suitable to deliver 900 LPM flowrate at 36 MWC head. [ii] Suitable HP squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, having IE3 efficiency and suitable for operation on 3- Ph, 415 V, 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class 'F' insulation, conforming to IS 12615: 2018. [iii] MS fabricated common base-plate, coupling, coupling guard, foundation bolts, etc. complete with accessories as required. [iv] Suitable cement concrete foundation duly plastered with anti vibration pads
NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. [v] Installation, testing and commissioning of the fire pump shall conform to IS15301: 2003 or NFPA 20.
S & Fof Pressure Gauge suitable for 0-14 kg pressure range with 4" dial, die cast aluminium body with white background & black marking, 1/2" Male NPT threaded connection, suitable to work in service temp. of -20 °C to 80 °C having accuracy of ± 1 % FSD assembled with ball valve, nipple, socket, etc. for pump suction & delivery lines of fire pump sets near the flow switches all complete as specified and directed by the engineer-in-charge.
M & L for 1.1 kV grade 3 core, 6 mm2 copper conductor, XLPE insulated armoured cable conforming to IS 7098-1: 1988, having stranded aluminium compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath,single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by the engineer-incharge.
M & L for 80mm NB (ISI marked) MS ERW Pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer,including supporting / fixing the pipe on floor / wall / ceiling with clamps, hangers,angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint (1st grade quality) complete all as specified and directed by the engineer-in-charge. NOTES: [i] Standard MS fittings with welded joint shall be used on the pipes. [ii] All hangers, clamps, brackets etc. shall be of galvenized iron. [iii] Welding of any kind on galvenised support / hanger shall not be permitted. [iv] The pipe size 150 mm NB & below shall be MS 'C' class as per IS 1239-1: 2004 & IS 1239-2: 2011. [v] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS 3589: 2001 [vi] Pipes of size more than 50 mm NB shall be butt welded with fittings of equal or higher thickness whereas pipes below 50 mm NB size shall be socket welded.
All as per item Ser No 5.00 here-in-above but 50 mm NB
All as per item Ser No 5.00 here-in-above but 25 mm NB
Supply and fix Valves, Sluice, flanged of class 1.6 PN ,80 mm (4”) dia
M & L for PN 1.6 rated air vent valve having brass body, cover, adopter, disc assembly & cap, stainless steel strainer, plastic float and 25 mm screwed threaded ends suitable for maximum operating temperature 100 °C installed on all high points in the water piping system to automatically remove the trapped air with necessary accessories all complete as specified and directed by the engineer-in-charge.
S & F swinging type 30 m long First Aid Hose Reel, conforming to IS:884-1969,having 19 mm NB thermoplastic reinforced hose reel tubing, conforming to IS 12585: 1988, 25 mm NB ball valve, stop cock, terminating with gunmetal coupling & nozzle of 6 mm NB outlet with shut-off valve, conforming to IS 8090:1976 complete with MS socket for tap-off, red colour drum, brackets (including painting) for fixing on wall with anchor fastner, bolts, nuts, etc. complete all as painting) for fixing on wall with anchor fastner, bolts, nuts, etc. complete all as specified and directed by the engineer-in-charge.
S & F 4 kg capacity dry chemical powder (ABC) type fire extinguisher,conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineerin- charge. (1 No. at entry/exit of each floor)
Refilling of 4.5 kg light-weight squeeze grip CO2 type fire extinguisher with CO2 gas filled in brand existing seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve,discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge.
S & F of 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-incharge. (In Parking Area) [i] Test Pressure: 250 kgf / Sq. cm [ii] Operating temperature : -300C to + 550C [iii] Locking pin and wire seal should be provided to indicate that the extinguisher has not been use. [iv] Every Extinguisher should be supplied with an operating manual.
S & F 9 kg capacity dry chemical powder (ABC) type fire extinguisher,conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineerin-charge. (1 No. at entry/exit of each floor)
S & F Galvanized mild steel Fire bucket (FILLED WITH DRY SAND) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket complete as specified and directed by the engineer-in-charge.
Supply and Fix but Addressable type multisensor detector with heat and smoke combination complete all as specified and as directed.
M & L for repairing of MICRO processer with Digital Display fire control Panel with Single Panel of capacity for 99 Detector & 99 Module upto 200 detector & modules fitting with autoatic battery charger including Maint free battery , including lamp with all connected accessories 4 Zone at 178 MH MI Room complete all as specified and as directed.
S & F testing & Commission of MICRO processer with Digital Display fire control Panel with Single Panel of capacity for 99 Detector & 99 Module upto 200 detector & modules fitting with autoatic battery charger including Maint free battery , including lamp with all connected accessories 4 Zone at 178 MH Patient ward block complete all as specified and as directed.
Supply and fix Fire Alarm sounders / Sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of + 5 DB for 1000 meter range complete all as specified and as directed.
Supply and fixing panel rectification programming, displace card change, battery charging card and battery 12v 7mpr complete all as specified and as directed.
S &F wiring for circuit / sub main wiring alongwith earth wire with the 2x4 sqmm size of FR PVC insulated copper conductor, single core in surface / recessed as required in MS conduite of 25mm dia including 1x4 sqmm continous PVC insulated earth conductor all asspecified.
Testing and commissioning charges for First aid fire hose reel and connected accessories complete all as specified and as directed.
M&L for Periodic maintenance & servicing of make Kirloskar and model DG set including the works as mentioned of capacity 7.5 KVA installed at 383 ASC Supply including replacement of spares complete including the following all as specified and directed by Engineer-in-Charge :-. (a) Change of Engine Oil including cleaning of engine oil chamber properly (Engine oil will be measured and paid seperately) (b) Replacement of LO filter, Fuel filter, By pass filter, O ring, Gasket sets, screws etc. (c) Lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather. (d) Change of Air cleaner evacuator valve and Check Fan hub / Idler and water pump. (e) Change of Cranckcase breather. Check Air piping and vibration damper. (f) Clean Fuel tank from inside. Draining out water from radiator assembly, clean properly and refill new after mixing with complete coolant in radiator including tightening all inlet and outlet connections. (g) Inspection of alternator and starter etc and replacement of parts as required (Parts will be measured seperately). (h) Applying grease, CRC in moving parts and and replacing minor items such as hose clamp, screws, washers etc Note: (i) If any fault/defects will be found during period of conract.Contractor will be rectified and inluded in quoted rate. (ii) Spares will be measured & paid separately under respective items here in after but fixing of the same is deemed to be included in quoted Rates.
Supply only Diesel fitter, against Item No 23.00 here-in-before.
Supply only Lub oil filter,against Item No 23.00 here-in-before.
Supply only Air filter element,against Item No 23.00 here-in-before.
Supply only Carbon brush, against Item No 23.00 here-in-before.
Supply only v belt for dynamo against Item No 23.00 here-in-before.
Supply only Fan belt,against Item No 23.00 here-in-before.
Supply only Lub oil pipe,against Item No 23.00 here-in-before.
M&L for Periodic maintenance & servicing of make Kirloskar green and model DG set includingthe works as mentioned of capacity 20 KVA installed at STP including replacement of spares complete including the following all as specified and directed by Engineer-in-Charge. (a) Change of Engine Oil including cleaning of engine oil chamber properly (Engine oil will be measured and paid seperately) (b) Replacement of LO filter, Fuel filter, By pass filter, O ring, Gasket sets, screws etc. (c) Lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather. (d) Change of Air cleaner evacuator valve and Check Fan hub / Idler and water pump. (e) Change of Cranckcase breather. Check Air piping and vibration damper. (f) Clean Fuel tank from inside. Draining out water from radiator assembly, clean properly and refill new after mixing with complete coolant in radiator including tightening all inlet and outlet connections. (g) Inspection of alternator and starter etc and replacement of parts as required (Parts will be measured seperately). (h) Applying grease, CRC in moving parts and and replacing minor items such as hose clamp, screws, washers etc Note: (i) If any fault/defects will be found during period of conract. Contractor will be rectified and inluded in quoted rate. (ii) Spares will be measured & paid separately under respective items here in after but fixing of the same is deemed to be included in quoted Rates.
Supply only Diesel fitter,against Item No 31.00 here-in-before.
Supply only Lub oil filter,against Item No 31.00 here-in-before.
Supply only Air filter element,against Item No 31.00 here-in-before.
Supply only coupling flanged type,against Item No 31.00 here-in-before.
Supply only Fan belt,against Item No 31.00 here-in-before. Make- DUNLOP/YULE/FENNER
Supply only high pressure oil pipe,against Item No 31.00 here-in-before.
Supply only Lub oil pipe,against Item No 31.00 here-in-before.
Supply only Radiator hose pipe set,against Item No 31.00 here-in-before.
Supply only LLOP Sensor,against Item No 31.00 here-in-before.
M&L for Periodic maintenance & servicing of make Koel green and model DG set including the works as mentioned of capacity 30 KVA installed at Burdong including replacement of spares complete including the following all as specified and directed by Engineer-in-Charge. (a) Change of Engine Oil including cleaning of engine oil chamber properly (Engine oil will be measured and paid seperately) (b) Replacement of LO filter, Fuel filter, By pass filter, O ring, Gasket sets, screws etc. (c) Lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather. (d) Change of Air cleaner evacuator valve and Check Fan hub / Idler and water pump. (e) Change of Cranckcase breather. Check Air piping and vibration damper. (f) Clean Fuel tank from inside. Draining out water from radiator assembly, clean properly and refill new after mixing with complete coolant in radiator including tightening all inlet and outlet connections. (g) Inspection of alternator and starter etc and replacement of parts as required (Parts will be measured seperately). (h) Applying grease, CRC in moving parts and and replacing minor items such as hose clamp, screws, washers etc Note: (i) If any fault/defects will be found during period of conract. Contractor will be rectified and inluded in quoted rate. (ii) Spares will be measured & paid separately under respective items here in after but fixing of the same is deemed to be included in quoted Rates.
Supply only Diesel fitter,against Item No 41.00 here-in-before.
Supply only Lub oil filter,against Item No 41.00 here-in-before.
Supply only Air filter element,against Item No 41.00 here-in-before.
Supply only Fan belt,against Item No 41.00 here-in-before. Make- DUNLOP/YULE/FENNER
Supply only high pressure oil pipe,against Item No 41.00 here-in-before.
Supply only Lub oil pipe,against Item No 41.00 here-in-before.
Supply only Radiator hose pipe set,against Item No 41.00 here-in-before.
M&L for Periodic maintenance & servicing of make Koel green and model DG set including the works as mentioned of capacity 40 KVA installed at Signal Centre including replacement of spares complete including the following all as specified and directed by Engineer-in-Charge. (a) Change of Engine Oil including cleaning of engine oil chamber properly (Engine oil will be measured and paid seperately) (b) Replacement of LO filter, Fuel filter, By pass filter, O ring, Gasket sets, screws etc. (c) Lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather. (d) Change of Air cleaner evacuator valve and Check Fan hub / Idler and water pump. (e) Change of Cranckcase breather. Check Air piping and vibration damper. (f) Clean Fuel tank from inside. Draining out water from radiator assembly, clean properly and refill new after mixing with complete coolant in radiator including tightening all inlet and outlet connections. (g) Inspection of alternator and starter etc and replacement of parts as required (Parts will be measured seperately). (h) Applying grease, CRC in moving parts and and replacing minor items such as hose clamp, screws, washers etc Note: (i) If any fault/defects will be found during period of conract. Contractor will be rectified and inluded in quoted rate. (ii) Spares will be measured & paid separately under respective items here in after but fixing of the same is deemed to be included in quoted Rates.
Supply only Diesel fitter,against Item No 49.00 here-in-before.
Supply only Lub oil filter,against Item No 49.00 here-in-before.
Supply only Air filter element,against Item No 49.00 here-in-before.
Supply only Fan belt,against Item No 49.00 here-in-before. Make- DUNLOP/YULE/FENNER
Supply only high pressure oil pipe,against Item No 49.00 here-in-before.
Supply only Lub oil pipe,against Item No 49.00 here-in-before.
Supply only Radiator hose pipe set,against Item No 49.00 here-in-before.
M&L for Periodic maintenance & servicing of existing make mahindra Cool & Kirloskar and model DG set including the works as mentioned of capacity 63 KVA/62.5 KVA installed at 617 EME BN/ MH oxygen plant including replacement of spares complete including the following all as specified and directed by Engineer-in-Charge. (a) Change of Engine Oil including cleaning of engine oil chamber properly (Engine oil will be measured and paid seperately) (b) Replacement of LO filter, Fuel filter, By pass filter, O ring, Gasket sets, screws etc. (c) Lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather. (d) Change of Air cleaner evacuator valve and Check Fan hub / Idler and water pump. (e) Change of Cranckcase breather. Check Air piping and vibration damper. (f) Clean Fuel tank from inside. Draining out water from radiator assembly, clean properly and refill new after mixing with complete coolant in radiator including tightening all inlet and outlet connections. (g) Inspection of alternator and starter etc and replacement of parts as required (Parts will be measured seperately). (h) Applying grease, CRC in moving parts and and replacing minor items such as hose clamp, screws, washers etc Note: (i) If any fault/defects will be found during period of conract. Contractor will be rectified and inluded in quoted rate. (ii) Spares will be measured & paid separately under respective items here in after but fixing of the same is deemed to be included in quoted Rates.
Supply only Diesel fitter,against Item No 57.00 here-in-before.
Supply only Lub oil filter,against Item No 57.00 here-in-before.
Supply only Air filter element,against Item No 57.00 here-in-before.
Supply only Carbon brush,against Item No 57.00 here-in-before.
Supply only Fan belt,against Item No 57.00 here-in-before. Make- DUNLOP/YULE/FENNER
Supply only high pressure oil pipe,against Item No 57.00 here-in-before.
Supply only Lub oil pipe,against Item No 57.00 here-in-before.
Supply only Radiator hose pipe set,against Item No 57.00 here-in-before.
M&L for Periodic maintenance & servicing of existing make mahindra Cool & Kirloskar and model DG set including the works as mentioned of capacity 100 KVA installed at Burdong Pump House including replacement of spares complete including the following all as specified and directed by Engineer-in-Charge. (a) Change of Engine Oil including cleaning of engine oil chamber properly (Engine oil will be measured and paid seperately) (b) Replacement of LO filter, Fuel filter, By pass filter, O ring, Gasket sets, screws etc. (c) Lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather. (d) Change of Air cleaner evacuator valve and Check Fan hub / Idler and water pump. (e) Change of Cranckcase breather. Check Air piping and vibration damper. (f) Clean Fuel tank from inside. Draining out water from radiator assembly, clean properly and refill new after mixing with complete coolant in radiator including tightening all inlet and outlet connections. (g) Inspection of alternator and starter etc and replacement of parts as required (Parts will be measured seperately). (h) Applying grease, CRC in moving parts and and replacing minor items such as hose clamp, screws, washers etc Note: (i) If any fault/defects will be found during period of conract. Contractor will be rectified and inluded in quoted rate. (ii) Spares will be measured & paid separately under respective items here in after but fixing of the same is deemed to be included in quoted Rates.
Supply only Diesel fitter,against Item No 66.00 here-in-before.
Supply only Lub oil filter,against Item No 66.00 here-in-before.
Supply only Air filter element,against Item No 66.00 here-in-before.
Supply only Carbon brush,against Item No 66.00 here-in-before.
Supply only Fan belt,against Item No 66.00 here-in-before. Make- DUNLOP/YULE/FENNER
Supply only high pressure oil pipe,against Item No 66.00 here-in-before.
Supply only Lub oil pipe,against Item No 66.00 here-in-before.
Supply only Radiator hose pipe set,against Item No 66.00 here-in-before.
M&L for Periodic maintenance & servicing of existing make mahindra Cool & Kirloskar and model DG set including the works as mentioned of capacity 125 KVA installed at Power House New cantt including replacement of spares complete including the following all as specified and directed by Engineer-in-Charge. (a) Change of Engine Oil including cleaning of engine oil chamber properly (Engine oil will be measured and paid seperately) (b) Replacement of LO filter, Fuel filter, By pass filter, O ring, Gasket sets, screws etc. (c) Lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather. (d) Change of Air cleaner evacuator valve and Check Fan hub / Idler and water pump. (e) Change of Cranckcase breather. Check Air piping and vibration damper. (f) Clean Fuel tank from inside. Draining out water from radiator assembly, clean properly and refill new after mixing with complete coolant in radiator including tightening all inlet and outlet connections. (g) Inspection of alternator and starter etc and replacement of parts as required (Parts will be measured seperately). (h) Applying grease, CRC in moving parts and and replacing minor items such as hose clamp, screws, washers etc Note: (i) If any fault/defects will be found during period of conract. Contractor will be rectified and inluded in quoted rate. (ii) Spares will be measured & paid separately under respective items here in after but fixing of the same is deemed to be included in quoted Rates.
Supply only Diesel fitter,against Item No 75.00 here-in-before.
Supply only Lub oil filter,against Item No 75.00 here-in-before.
Supply only Air filter element,against Item No 75.00 here-in-before.
Supply only Carbon brush,against Item No 75.00 here-in-before.
Supply only Fan belt,against Item No 75.00 here-in-before. Make- DUNLOP/YULE/FENNER
Supply only high pressure oil pipe,against Item No 75.00 here-in-before.
Supply only Lub oil pipe,against Item No 75.00 here-in-before.
Supply only Radiator hose pipe set,against Item No 75.00 here-in-before.
M&L for Periodic maintenance & servicing of make Kirloskar,Cummins, Greaves and model DG set including the works as mentioned of capacity 320 KVA installed at 178 MH, 17 MDSR & JADC including replacement of spares complete including the following all as specified and directed by Engineer-in-Charge. (a) Change of Engine Oil including cleaning of engine oil chamber properly (Engine oil will be measured and paid seperately) (b) Replacement of LO filter, Fuel filter, By pass filter, O ring, Gasket sets, screws etc. (c) Lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather. (d) Change of Air cleaner evacuator valve and Check Fan hub / Idler and water pump. (e) Change of Cranckcase breather. Check Air piping and vibration damper. (f) Clean Fuel tank from inside. Draining out water from radiator assembly, clean properly and refill new after mixing with complete coolant in radiator including tightening all inlet and outlet connections. (g) Inspection of alternator and starter etc and replacement of parts as required (Parts will be measured seperately). (h) Applying grease, CRC in moving parts and and replacing minor items such as hose clamp, screws, washers etc Note: (i) If any fault/defects will be found during period of conract. Contractor will be rectified and inluded in quoted rate. (ii) Spares will be measured & paid separately under respective items here in after but fixing of the same is deemed to be included in quoted Rates.
Supply only Diesel fitter,against Item No 84.00 here-in-before.
Supply only Lub oil filter,against Item No 84.00 here-in-before.
Supply only Air filter element,against Item No 84.00 here-in-before.
Supply only Carbon brush,against Item No 84.00 here-in-before.
Supply only coolant switch against Item No 84.00 here-in-before.
Supply only Fan belt,against Item No 84.00 here-in-before. Make- DUNLOP/YULE/FENNER
Supply only high pressure oil pipe,against Item No 84.00 here-in-before.
Supply only Lub oil pipe,against Item No 84.00 here-in-before.
Supply only Radiator hose pipe set,against Item No 84.00 here-in-before.
M&L for pumping down the gas of the Central AC plant 178 MH of various capacities pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying and sealing the leakage by gas welding/ brazing pressure, completely vaccuming the system and re-charging the system with R-22 gas or as mentioned in the AC plant system, testing and commissioningcomplete all as specified and as directed. Note- Refrigent and Nitrogen gas measured and paid seperately under respective items
M& L for servcing of monoblock centrigugal pump sets 5.0 HP capacity, 3 phase 415 volt, 50 Hz the pump sets by repalcing the worn out bushes, gland rope, gland bolts & nuts, etc including testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
M & L for dismantling pump set 5.0 HP removing scales cleaning, heating varnishing of motor winding , pump sets by repalcing the worn out bushes, gland rope, gland bolts & nuts, painting etc reassembling the complete pump set including testing and commissioning complete all as specified and as directed by Engineer - in - Charge.
Supply and fix in repair of ball bearing of 6205/6206/6207 sizes with new ball bearing formotor 1.5 kw, 3 phase complete all as specified and as directed. Make:- NBC/SKF
Supply and filling of compressor oil suitable for compressor at various installation after draining the old oil complete all as specified and as directed by Engineer - in - charge. NOTE : Empty can will be returned to contractor after consumption of Oil. The oil to be supplied in sealed can.
M & L for repairing fan motor of capacity 1.5 KW , 3 phase after disconnecting and removing it from its position and getting it repaired by copper winding the motor with copper wires of same guage and re-fixing the same and re-connecting all the electrical wiring , testing complete ass as specified and as directed.
M & L for repairing HVAC compressor, scroll type Make Danfoss, model No. SM185S4RC, 415V, 50 HZ,for R-22 after dismantling from the HVAC system, after extracting the gas completely from the system and storing it for further re-use, securing the liquid line and gass line, transporting to the work shop, and re-instating the same after rectifying the defect , charging the system with refrigerant gas and successful commisioning of the HVAC system complete all as specified and as directed by Engr-in-charge. NOTE:- Refrigent gas shall be measured and paid seperately under respective items.
M&L for cleaning, servicing including carrying out preventive maintenance of Air Cooled chilller package type AC plant 3 X 22 TR at 178 MH capacity using suitable cleaning solution, tools and minor spares viz screws, washers, insulation tapes etc. as per site requirement and as directed. cleaning of the evaporator, fins, chiller unit and cooling coils shall be done using blower/ vacuum cleaner and replacement of unserviceable spares and ensuring its serviceability by keeping the AC plant in good working condition complete all as directed by Engineer-in-Charge. NOTE:- Job under this item shall be liable for rectification of any defect occured during the preventive maintenance period of the contract. Spare parts required shall be measured as paid separately under respective items but fixing for the same shall be considered in quoted rate of this items. Make: Voltas
Supply only Heating Coil 3 KW for 1x22 TR AC Plant complete all as specified and as directed.
Supply only R-22 Gas complete all as specified and as directed by Engr-in-charge
Supply Nitrogen gas cylinder for leakage testing complete all as specified and as directed.
M & L for gas brazing of copper tubes with copper or silver or any other metal as filler material as per requirement complete all as specified and as directed. NOTE : The quoted rate also includes the job to cut and prepare the tube surfaces as required before welding as directed by Engr-in-charge
Supply and fix in drier size 5/8" of make Danfoss or its equivalent
Supply only controller single phase 230volt, 50 Hz for 1x22 Tr ac plant at 178 MH complete all as specified and as directed.
Supply and fix copper pipe 5/8 inch(hard) complete all as specified and as directed.
Supply and fix Single phase preventor L&T Cat no - ST92166OOOO & CS94824COOO or its equivalent in ABB, Siemens. for AC plant 3X22 TR at 178 MH complete all as specified and as directed.
Supply and fix display for Air Cooled chilller package type AC plant 1X 22 TR at 178 MH capacity complete all as specified and as directed.
Supply and fix voltage protection relay for Air Cooled chilller package type AC plant 1X 22 TR at 178 MH capacity complete all as specified and as directed. Make- L&T/Seimens/Schenider/ABB
Supply and fix emergency switch forAir Cooled chilller package type AC plant 1X 22 TR at 178 MH complete all as specified and as directed.
Supply and fix outdoor fan motor 3 phase 2.0 HP, 415 volt ,50 Hz capacity for Air Cooled chilller package type AC plant 1X 22 TR at 178 MH capacity complete all as specified and as directed.
Supply only expension valve of Central AC plant 1X 22 TR capacity complete all as specified and as directed. Make- danfoss/voltas/carrier/Bluestar
S&F in repairs MCB TP 32A to 40 Amp, C type complete all as specified and as directed.
S&F in repairs Power contactor AC operational current upto 415V and 9A of Siemens Cat No - 3RT1023-1A or its equivalent in ABB, L&T
S&F in repairs temperature controller of SubZero Cat No - 7510T or equivalent in Danfoss
S&F in repairs 3 Pole power contactor MNX12 AC operational current upto 415v of L&T Cat no - CS94108/CS94109 or its equivalent in ABB, Siemens.
S&F in repairs 3 Pole power contactor MNX9 AC operational current upto 415v of L&T Cat no - CS94106/CS94107 or its equivalent in ABB, Siemens.
S&F in repairs MN suitable for MNX Contactor 24-30A, 415V of L&T Cat no - SS94145OOFO or its equivalent in ABB, Siemens.
S&F in repairs electronic timer of L&T Cat no - ST80328OOOO or its equivalent in ABB, Siemens.
S&F in VAF + PF Meters, of L&T Cat no - WL411021OOOO or its equivalent in ABB, Siemens.
S&F in Voltage monitoring relay 3 phase, 3 wire, Siemens of Cat no - 7UG0818-1AA20 or its equivalent in ABB, L&TSiemens.
S&F in Temperature controlling relay 110-240V AC phase, Siemens of Cat no - 7UG0480-1IU20 or its equivalent in ABB, L&TSiemens.
M & L for descaling of the condensers tubes and other tubes as directed of 21 TR capacity by suitable chemical reagent (HCL & others) by pressure feed method by pump after disconnecting condenser water lines, and opening the end covers of both side, disconnecting electrical supply, brushing with suitable size of wire brush removing the scales and maintaining proper internal diameter and refixing all dismantled parts including replacement of 3mm thick rubber gasket set complete all as specified and as directed.
Supply & fix in repair pressure gauge of HP/LP/OP of size 4" dia of rating 0-16 Kg/cm2 or 0 - 300 PSI(lb/in2) complete all as specified and as directed. Make : Feibig / H-Guru
Supply & fix in repair temperature guage size 4"dia of rating 0 to 50 degrees complete all as specified and as directed. Make: Allied/ Altod/ Fiebig / Heibig / Scientific
Supply and fix in repair water pressure cut out valve 1 PS - 70 complete all as specified and as directed. Make : Danfoss / Indfoss/Rapid
Supply and fix in repair LP / HP cut out valves uitable for R - 407 C gas complete all as specified and as directed. Make : Danfoss / Indfoss//Rapid
Supply and fix in rapair oil pressure control switch type MP - 55 suitable for R - 407 C complete all as specified and as directed. Make : Danfoss / Indfoss
Supply and fix in repair solinoid pilot control valve type 10 with two / three coil assembly of same model complete all as specified and directed by Engineer - in - Charge
Supply and fix in repair water flow Sensor/switch WFS6000 Max Pressure 150 PSI, Max temp - 100 degree,1'' NPT,15 A,250V complete all as specified and as described. Make : Honeywell / Dansfoss / Emmerson/Rapid
S & F in repair Air filter for AHU of suitable size (min 2 feet x 2 feet) for 3X22 TR capacity central AC plant(178 MH) of tests all as per existing sample complete all as specified and as directed.
Material & Labour for carrying out the chemical servicing/deep cleaning of the Air Handling units & cooling coils by applying the non-aciditic scale removing agent to the fins area of the cooling coil, copper tubes, remove the complete scale deposit across the coil, flushing through and complete blowing out the dirt, cleaning the fan impellers, filter section, fan section and complete cleaning of filters, tightening of all bolts & nuts, renew the rusted bolts & nuts checking the alignment of the drive set and testing & commissioning the Air Handling units of AC plant complete all as specified and as directed by Eng-in-charge.
Supply & fix in repair mini plate Hepa Filter of size(610X610X75) mm(WXHXD) of existing make and model at 178 MH (ICU & OT) and diretced by Engr-in-Charge with following specification. Make- Thermadyne (i) Frame-Aliminium Extruded sections(Non Anodized) (ii) Type of Filter-Flanged Type (iii) Media- Micro fibre Glass(Imported) media protected with Al mesh (iv) Sealing of Media-By Means of Epoxy (v) Efficiency-Above 99.975 down to0.3 micron particle (vi) I.P.D.-- 16+10% mm WG (vii) F.P.D.-50 mm WG (viii) Separators-Hotmelt Glue (ix) Filter face velocity-125FPM (x) Operating Temp- Normal atmospheric Temperature (xi) Air flow direction-cassettle to flange
Supply and fix in repair PRE Filters EU4(washable Tpye) of size(610X610X50)mm (WXDXH) of existing make and model at 178 MH(ICU& OT) and as directed by Engr-in-Charge with following specifiction. Make-Thermadyne (i) frame- Aliminium Extruded sections(Non- Anodized) (ii) Type of filter-Box type (iii) Media- Non Woven Synthetic media supported by Al mesh on one side& finished with HDPE mesh on the other side. (iv) sealing of media-By means of Epoxy (v) I.P.D.- 5mm WG (vi) F.P,D.-15mm WG (vii) No of folders-11 Nos/RFT of filteration
M&L for cleaning, servicing including carrying out preventive maintenance of 3 phase 415 volt 50 Hz inverter outdoor Variable flow refrigerent type (22+22+14) 58 HP capacity using suitable cleaning solution, tools and minor spares viz screws, washers, insulation tapes etc. as per site requirement and as directed. cleaning of the scroll compressor,condenser , evaporator, fins, and cooling coils shall be done using blower/ vacuum cleaner and replacement of unserviceable spares and insuring its serviceability by keeping the AC plant in good working condition complete all as specified and as directed by Engineer-in-Charge. Make: Blue star model IVRFB-22THN/ IVRFB-22 / IVRFB-14THN NOTE:-(i) During period of contract any fault/defects obtain shall be rectified and quoted rate shall also included the same. (ii) Spare parts shall be measured and paid under respective items but fixing for the same shall be considered in quoted rate.
Supply only fan board PCB for VRF type Acs 58 HP IVRFB-22THN/ IVRFB-14THN complete all as specified and as directed.
Supply only main board PCB for VRF type Acs 58 HP IVRFB-22THN/ IVRFB-14THN complete all as specified and as directed.
Supply only BLDC motor for VRF type Acs 58 HP IVRFB-22THN/ IVRFB-14THN complete all as specified and as directed.
Supply only drive board for VRF type Acs 58 HP IVRFB-22THN/ IVRFB-14THN complete all as specified and as directed.
Supply only noise filter for VRF type Acs 58 HP IVRFB-22THN/ IVRFB-14THN complete all as specified and as directed.
Supply only R-410(A) Gas all as directed by Engr-in-charge complete all as specified and as directed.
M&L for cleaning, servicing including carrying out preventive maintenance of single phase 230 volt volt 50 Hz inverter indoor(ductable) indoor unit cassette type Variable flow refrigerent typecleaning of the coil ,filter, fan deepcleaning with jet/blower of 2.0 TR capacity, Model DSD-24 using suitable cleaning solution, tools and minor spares viz screws, washers, insulation tapes etc. as per site requirement and as directed and replacement of unserviceable spares and insuring its serviceability by keeping the AC plant in good working condition complete all as directed by Engineer-in-Charge. NOTE:-(i) During period of contract any fault/defects obtain shall be rectified and quoted rate shall also included the same. (ii) Spare parts shall be measured and paid under respective items but fixing for the same shall be considered in quoted rate.
All as per Srl item No 144.00 here-in-above but 2.5 TR capacity complete all as specified and as directed.
All as per Srl item No 144.00 here-in-above but 8.0 TR capacity complete all as specified and as directed.
All as per Srl item No 144.00 here-in-above but 1.7 TR capacity complete all as specified and as directed.
Supply only Cordless display for indoor units for VRF Acs complete all as specified and as directed.
Supply and fix in repair of 3 pole power contractor of MNX 50 Amps complete all as specified and directed.
Supply only VRF power /invertor power supplyboard for indoor unit VRF type AC Plant all complete as specified and as directed by Engr-in-charge.
Supply only outdoor unit DLT sensor for VRF type AC Plant all complete as specified and as directed by Engr-in-charge.
Supply only indoor unit PCB board for VRF type AC Plant all complete as specified and as directed by Engr-in-charge.
Supply only single phase contactor for VRF type AC Plant all complete as specified and as directed by Engr-in-charge.
Supply only indoor unit SMPS for VRF type AC Plant all complete as specified and as directed by Engr-in-charge.
Supply only indoor unit sensor(LIQ/GAS) for VRF type AC Plant all complete as specified and as directed by Engr-in-charge.
supply only indoor unit blower motor for model DSD-24 2TR ceiling mounted casette type complete all as specified and as directed.
supply only indoor unit blower motor for model DSD-30 2.5TR ceiling mounted casette type complete all as specified and as directed.
supply only indoor unit blower motor for model DSD-96 8TR ceiling mounted casette type complete all as specified and as directed.
supply only indoor unit blower motor for model VHW-20A 1.7 TR Wall mounted complete all as specified and as directed.
supply only indoor unit Dust Filter for model DSD-24/30/96/ VHW blower Units complete all as specified and as directed.
Cleaning, servicing including carrying out preventive maintenance of summer appliances viz indoor and outdoor unit of split air conditioners 2.00 Ton capacity using suitable cleaning solution, tools and minor spares viz screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. cleaning of the condenser , evaporator, fins and cooling coils shall be done using blower/ vacuum cleaner and replacement of unserviceable spares and insuring its serviceability by keeping the AC in good working condition complete all as directed by Engineer-in-Charge. Note :- (i) Spares part required will be measured and paid separately under respective item of this schedule. However for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz screws, washers, teflon seal, rubber bush, insulating tape, copper thimble, copper connecting jack, short length connecting wire, etc are deem to be included in the quoted rate.
All as per item No 161.00 above but for 1.50 Ton Capacity complete all as specified and as directed.
All as per item No 161.00 above but for 2 body freezer capacity complete all as specified and as directed.
All as per item No 161.00 above but for Refrigerator capacity Min 180 Ltrs as per site requirement complete all as specified and as directed.
All as per item No 161.00 above but for Deepfreezer capacity Min 190 Ltrs as per site requirement complete all as specified and as directed.
Taking out unserviceable Compressor of 2.00 Ton capacity AC from site and replacement of compressor with new one to match the existing make/model (R compressor ) and fixing of new sealed unit in position, charging required quantity of refrigerant gas as per existing design of AC, brazing of discharge and suction line including leak testing after vacuum testing and repair to the system including testing on load complete all as directed by Engineer-in-charge. Make :- Kirlosker / Hitachi / Copeland / Danfoss. Note :- Cost of copper capillary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
All as per item No 166.00 above but for 1.50 Ton Capacity complete all as specified and as directed.
All as per item No 166.00 above but for deepfreezer as per site requirement complete all as specified and as directed.
All as per item No 166.00 above but for Refrigerator as per site requirement complete all as specified and as directed.
M&L for gas charging with refrigerant gas suitable for Split AC of any make, model and capacity, and taking down leak testing upto 24 hrs and to achieve desired suction pressure and temperature complete all as per specified and directed.
All as per Ser Item No 170.00 above but for water cooler of any type and capacity as per site requirement as described complete all as specified and as directed.
All as per Ser Item No. 170.00 above but for refrigerator/Deep freezer of any type and capacity as per site requirement below complete all as specified and as directed.
All as per Ser Item No. 170.00 above 2 body freezer of any type and capacity as described below complete all as specified and as directed.
Supply only of PCB for split AC capacity 1.5/2 Ton capacity complete all as specified and directed.
Supply only starting capacitor 80 to 100 MFD suitable for Split type AC 1.5 / 2.0 Ton/Deepfreezer/Refrigerator of any make complete all as specified and as directed.
Supply only running capacitor 36 MFD suitable for split type A C 1.5/2.0 Ton/Deepfreezer/Refrigerato complete all as specified and as directed.
M& L for preparation of old painted surfaces of firefighting MS pipe,diesel engine,electric motor different dia above GL/Copping including cross section channels,flat iron clamps by srapping with wire brush applying one coats of red oxide paint (red paint) including pole numbering using three layer of inch on each pole using printer letter all as specified and directed. Note-:(i) Ladders scaffolding,safety belts etc required for execation of works shall be arranged by contractor & cost of the same is deemed to be included in the unit rate quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people enagaged by him & any issues(if any) arising during the work shall be dealt by the contractor& the Dept shall be no way responsibile whatever.
GEETA CONSTRUCTION (BID ID -3393661)
BIJAY MITTAL (BID ID -3397254)
M/S ANIL KUMAR THAKUR (BID ID -3399733)
M/S S. S CHETTRI AND SONS (BID ID -3399906)
KAMLESH ENTERPRISE (BID ID -3398316)
RAAJ BANGAR (BID ID -3397640)
MAHENDRA KHAWAS (BID ID -3400028)
DHARMINDER SINGH (BID ID -3399564)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .