| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAdmitted-Finance | ₹41.8 L | L1 | Admitted-Finance |
| 2 | L2₹45.5 LAdmitted-Finance 127 102 JUHI KANPUR | KANPUR | KANPUR | UTTAR PRADESH | ₹45.5 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VIBHU ENTERPRISES L2 | SANA ELECTRICALS L1 |
|---|---|---|---|---|---|
| 1.00Safe carriage, loading and unloading of following material from ESC DaliganjLucknow in work site J.E. dump store | |||||
| 2.00 | Line Material | 15 | Qtl | 220 ₹3,300 | 220 ₹3,300 |
| 3.00 | PCC Pole 8.5/9 Mtr long. | 150 | Nos | 510 ₹76,500 | 495 ₹74,250 |
| 4.00 | S.T.P. Pole 9/11 Mtr. Long | 50 | Nos | 550 ₹27,500 | 550 ₹27,500 |
| 5.00 | Repairing of damage/Rusted Steel Tubular Pole by digging of pit up to2 for proper position, Putting 3 Nos. Angle From of size 35x35x6 mm, 3 Long properly welding on 3 circle with pole than Grouting and Plinthing 300 mm Above level with cement concrete and sand and bricks ballast, (All material, labour and T&P will be provided by the Contractor) | 50 | Nos | 3,500 ₹1.8 L | 3,500 ₹1.8 L |
| 6.00 | Opening and dismantling of all the wire and accessories from tilted pole and digging the pit for Strengthening of existing tilted support of HT/LT lines after strengthening of tilted pole fixing of all accessories and re-stringing of old HT/LT line with help of T&P. | 50 | Nos | 2,500 ₹1.3 L | 2,000 ₹1 L |
| 7.00 | Dragging of ST/PCC Pole to pit site, digging of pit erection and grouting (As per RESPO Norms) of 11 KV line with fixing of necessary item, such as V-type X-arm, F-bracket, 11 KV Pin insulator, Guarding angle (1.8 mm 65x65x6) with Nut & bolts its ramming as per RESSPO Specification. Only Pole and insulator will be Provided by the Department. | 50 | Nos. | 4,000 ₹2 L | 3,800 ₹1.9 L |
| 8.00 | Dragging of ST/PCC Pole from Dump Store to pit site, digging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification. Only Pole will be Provided by the Department. | 150 | Nos | 3,500 ₹5.3 L | 3,000 ₹4.5 L |
| 9.00 | Well type earthing of with 60 Fit Deep boring and providing GI Pipe 1.5" dia ("B" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor. | 20 | Nos | 10,500 ₹2.1 L | 10,500 ₹2.1 L |
| 10.00 | Wiremess fencing of 11/0.4 KV S/S shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I. All Material provided by contractor. | 15 | Nos | 26,000 ₹3.9 L | 26,000 ₹3.9 L |
Tender Value
Refer Docs
EMD Value
₹45,500
Closing Date
18 Apr 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER, (TECHNICAL), AMAUSI ZONE
Sec-5, D, Vrindavan, Amausi Zone, Lucknow
48/SE(T)AMAUSI ZONE/2025-26
2026_MVVNL_1116162_2
48/SE(T)AMAUSI ZONE/2025-26
Open Tender
Electrical Works
365 days
LUCKNOW
As per Tender Document
2 documents required · 2 mandatory
₹3,540
E.E., EDD, CESS-Ist, LESA, Lucknow
₹45,500
23 Apr 2026
13 Apr 2026
18 Apr 2026
13 Apr 2026
18 Apr 2026
13 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Safe carriage, loading and unloading of following material from ESC DaliganjLucknow in work site J.E. dump store | - | - | - | - |
| 2 | Line Material | 15 | Qtl | - | - |
| 3 | PCC Pole 8.5/9 Mtr long. | 150 | Nos | - | - |
| 4 | S.T.P. Pole 9/11 Mtr. Long | 50 | Nos | - | - |
| 5 | Repairing of damage/Rusted Steel Tubular Pole by digging of pit up to2 for proper position, Putting 3 Nos. Angle From of size 35x35x6 mm, 3 Long properly welding on 3 circle with pole than Grouting and Plinthing 300 mm Above level with cement concrete and sand and bricks ballast, (All material, labour and T&P will be provided by the Contractor) | 50 | Nos | - | - |
| 6 | Opening and dismantling of all the wire and accessories from tilted pole and digging the pit for Strengthening of existing tilted support of HT/LT lines after strengthening of tilted pole fixing of all accessories and re-stringing of old HT/LT line with help of T&P. | 50 | Nos | - | - |
| 7 | Dragging of ST/PCC Pole to pit site, digging of pit erection and grouting (As per RESPO Norms) of 11 KV line with fixing of necessary item, such as V-type X-arm, F-bracket, 11 KV Pin insulator, Guarding angle (1.8 mm 65x65x6) with Nut & bolts its ramming as per RESSPO Specification. Only Pole and insulator will be Provided by the Department. | 50 | Nos. | - | - |
| 8 | Dragging of ST/PCC Pole from Dump Store to pit site, digging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification. Only Pole will be Provided by the Department. | 150 | Nos | - | - |
| 9 | Well type earthing of with 60 Fit Deep boring and providing GI Pipe 1.5" dia ("B" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor. | 20 | Nos | - | - |
| 10 | Wiremess fencing of 11/0.4 KV S/S shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I. All Material provided by contractor. | 15 | Nos | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.94 MB
BOQ_2121791.xls
BOQ • 0.30 MB
T48FORMM.pdf
Tender Documents • 1.60 MB
Download all tender documents and submit your bid