Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹30.9 L+₹1.2 L (4.03%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹39.4 L+₹9.7 L (32.6%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L3 | Rejected-AOC L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹99,920
Closing Date
20 Feb 2021, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT OF WATER SUPPLY IN DCDA, GUARD POST IN METCALFE HOUSE AND FIRE FIGHTING SYSTEM IN P-25 AND P-28, LT PANELS, LT UG CABLES AND CERTAIN ALLIED WORKS IN ZONE B AREA AT KWC AREA UNDER GE I RND DELHI
2021_MES_414767_1
GE/RND-76/DLI/2020-2021
Open Tender
Civil Works
Item Rate
180 days
DELHI
Class-D, Cat - a(ii), b(i)
2 documents required · 2 mandatory
₹500
Yes
GE I RND DELH
₹99,920
Yes
12 Mar 2021
21 Jan 2021
22 Feb 2021
21 Jan 2021
20 Feb 2021
8 Feb 2021
Amount
Excavation in trenches in loose/soft soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out complete all as specified and as directed.
All as per item No. 2 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc complete all as specified and as directed.
Returning, filling in and including spreading, levelling and watering and well ramming in layers not exceeding 25 cm to achieve desired compactness complete all as specified and as directed.
Removing surplus soil to a distance exceeding 1.5Km and depositing where directed at a level and not exceeding 5Km above the starting point complete all as specified and as directed.
M&L for brick work in CM (1:4) with sub class 'B' bricks straight or curved on plain above ground level and not exceeding 1.5mtr in height from ground level including demolition of old unserviceable brick work complete all as specified and as directed.
M&L for PCC (1:4:8) type B-1 (using 20mm graded stone aggregate) finished even and smooth without using extra cement for foundation complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) finished even and smooth without using extra cement as on brick pillars complete all as specified and as directed.
M&L for rendering 10 mm thick plaster on brick work/concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed.
Taking down/out GI pipe water mains including all fittings complete all as specified and directed sizes 15mm bore complete all as specified and directed.
Taking down/out GI pipe water mains including all fittings complete all as specified and directed sizes 20mm bore complete all as specified and directed.
Taking down/out GI pipe water mains including all fittings complete all as specified and directed sizes 25mm bore. complete all as specified and directed.
Taking down/out GI pipe water mains including all fittings complete all as specified and directed sizes 40mm bore complete all as specified and directed.
Taking down/out GI pipe water mains including all fittings complete all as specified and directed sizes 50mm bore complete all as specified and directed.
Taking down/out GI/MS pipe water mains including all fittings complete all as specified and directed sizes 80mm bore complete all as specified and directed.
Taking down/out GI/MS pipe water mains including all fittings complete all as specified and directed sizes 100mm bore complete all as specified and directed.
Taking down/out GI/DI/CI pipe water mains including all fittings complete all as specified and directed sizes 150mm bore complete all as specified and directed.
Supply and laying 15 mm bore tubing GI pipe medium grade ISI marked including all fittings in old position in trenches/wall/floor complete all as specified and directed.
Supply and laying 20mm bore tubing GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor complete all as specified and directed.
Supply and laying 25mm bore tubing GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor complete all as specified and directed.
Supply and laying 40mm bore tubing GI pipe medium grade ISI marked including all fittings in old position in trenches/wall/floor complete all as specified and directed.
Supply and laying 50mm bore tubing GI pipe medium grade ISI marked including all fittings in old position in trenches/wall/floor complete all as specified and directed.
Supply and laying 80mm bore tubing GI pipe medium grade ISI marked including all fittings in old position in trenches/wall/floor complete all as specified and directed.
Supply and laying 100mm bore tubing GI pipe medium grade ISI marked including all fittings in old position in trenches/wall/floor complete all as specified and directed.
Supplying, Laying, jointing, testing and commissioning in repair of DI Pipe of 150 mm bore size, with spigot and socketed ends centrifugally cast Class K-7 Push on joint confirming to IS 8329 laid in trenches complete all as specified and directed.
M&L DI fittings for spigot/socket pipes such as bends of any radius and angle, collars, tapers, tail pieces, Tee pieces, Caps and plugs suitable upto 150 mm bore dia all socketed or socket and spigot or side flanged complete all as specified and directed.
M&L in repair for burning out lead joint in any position including removing old lead joint and making new lead joint by using the retrieved lead and adding minimum 700 gram new lead for CI pipe of 150mm bore pipes complete all as specified.
M&L in repair for burning out lead joint in any position including removing old lead joint and making new lead joint by using the retrieved lead and adding minimum 500 gram new lead for CI pipe of 100mm bore pipes complete all as specified.
M&L in repair for burning out lead joint in any position including removing old lead joint and making new lead joint by using the retrieved lead and adding minimum 400 gram new lead for CI pipe of 80mm bore pipes complete all as specified.
M&L in repair for Rubber Gasket Joint (tyton joint) including jointing material for DI/CI pipe of size 150 mm bore dia, complete as specified.
Supplying, laying jointing testing MS pipe, of dia 80 mm Heavy duty class 'C' confirming to IS - 1239 of undermentioned sizes, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, complete all as specified and directed. (Note : Welded flanges will be measured and paid separately.)
Supplying, laying jointing testing MS pipe, of dia 100 mm Heavy duty class 'C' confirming to IS - 1239 of undermentioned sizes, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, complete all as specified and directed. (Note : Welded flanges will be measured and paid separately.)
Supply and fixing welded to flanges on ends for MS pipe of dia 80 mm, flange not less than 15mm thick, as specified and directed.
Supply and fixing welded to flanges on ends for MS pipe of dia 100 mm, flange not less than 15mm thick, as specified and directed.
M&L Joints with rubber or fibre board gasket for 80 mm bore pipe complete with nut,bolt and double washers, as specified and directed.
M&L Joints with rubber or fibre board gasket for 100 mm bore pipe complete with nut, bolt and double washers, as specified and directed.
S&F in repair of cast iron Sluice Valve of dia 50 mm ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
All as per ser item No. 36.00 above but dia 80mm.
All as per ser item No. 36.00 above but dia 100mm.
All as per ser item No. 36.00 above but dia 150mm.
S&F in repair CI Non return Valve of dia 50 mm with GM seat, PN-1.0 ISI marked, including flange joints such as packing, nut and bolts, as per IS:5312 complete all as specified and directed.
All as per ser item No. 40.00 above but dia 80mm.
All as per ser item No. 40.00 above but dia 100mm.
All as per ser item No. 40.00 above but dia 150mm.
S&F in repair CI foot valve flanged type of dia 80 mm with strainer confirming to IS:4038 with flanged ends of size complete all as specified and directed.
All as per ser item No. 44.00 above but dia 100mm.
All as per ser item No. 44.00 above but dia 150mm.
Labour only for cutting of existing CI / DI pipe of dia 80 mm for insertion of CI specials /valves etc. all as required including dewatering of leakage water complete all as specified and directed.
All as per ser item No. 47.00 above but dia 100mm.
All as per ser item No. 47.00 above but dia 150mm.
S&F in repair PVC Float valve of dia 15 mm with epoxy coated aluminium rod and high density ball including fitting ISI Marked, as per IS:12234 complete all as specified and directed.
All as per ser item No. 50.00 above but dia 20mm.
All as per ser item No. 50.00 above but dia 25mm.
All as per ser item No. 50.00 above but dia 40mm.
All as per ser item No. 50.00 above but dia 50mm.
S&F in repair Gun Metal gate valve of size 15 mm dia with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778 complete all as specified and directed.
All as per ser item No. 55.00 above but dia 20mm.
All as per ser item No. 55.00 above but dia 25mm.
All as per ser item No. 55.00 above but dia 40mm.
All as per ser item No. 55.00 above but dia 50mm.
S&F in repair flanged water meter woltman type of dia 50 mm including gasket, nut, bolt & double washer as per ISO 4064.
All as per ser item No. 60.00 above but dia 80mm.
All as per ser item No. 60.00 above but dia 100mm.
All as per ser item No. 60.00 above but dia 150mm.
S&F in repair Strainer Y type conforming to IS, size 80 mm (3”) dia.
S&F in repair Strainer Y type conforming to IS, size 100 mm (4”) dia.
S&F in repair Strainer Y type conforming to IS, size 150 mm (6”) dia.
M&L for painting with two coat of synthetic enamelled paint over a coat of red oxide primer on steel surface all as specified and directed.
M&L in repair of MS sheet/angle including cutting ,welding and make of required size including painting with synthetic enamel paint two coat over one coat of red oxide primer complete all as specified and directed.
S&F in repair of power contactor of current rating upto 60 amps and standard coil voltage 240v, 50Hz type ML-2 of aux contact (2 NO + 2 NC) including reconnection of cable & testing complete all as specified and directed.
S&F in repair of power contactor of current rating upto 60 amps and standard coil voltage 240v, 50Hz type ML-3 of aux contact (2 NO + 2 NC) including reconnection of cable & testing complete all as specified and directed.
S&F in repair of power contactor before but of current rating upto 125 Amps and standard coil voltage 240v, 50Hz type ML-4 of aux contact (2 NO + 2 NC) including reconnection of cable & testing.
M&L for bocky system under path/road to pass the GI/CI/DI Pipes upto 150 mm dia manually as directed..
M&L for laying of MS ERW pipe of bore 100 mm confirming to IS-1259 PART-2, medium grade including taking down old unserviceable pipe complete all as specified and directed.
S&F MS ERW pipe of bore 80 mm confirming to IS-1259 PART-2, medium grade including taking down old unserviceable pipe complete all as specified and directed.
S&F in repair of MS ERW pipe of bore 25 mm confirming to IS-1259 PART-2, medium grade including taking down old unserviceable pipe complete all as specified and directed.
Supply and fixing in repair sluice valve 100 mm bore class-1 ISI marked confirming to IS-14846 flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheet at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed.
Supply and fixing in repair sluice valve 80 mm bore class-1 ISI marked confirming to IS-14846 flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheet at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed.
S&F in repair of Non Return Sluice Valve PN-1.6 of dia 100 mm confirming to IS-5312 PART-2 complete all as specified and directed.
S&F in repair of gun metal gate valve PN-1.6 for High pressure line with iron wheel head screwed both ends for iron pipe, ISI marked, as per IS : 778 of sizes 25 mm bore dia complete all as specified and directed.
Supply and fixing in repair SS (Stainless Steel) double head landing valve with 80 mm N.B. flanged inlet, SS spindle (IS : 6603) controlled 63 mm dia instantaneous female outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290. Including fixing with anchor fastener and flanged tapping from wet riser complete all as specified and directed.
Supply and fixing in repair of Non-percolating rubber reinforced lined fire hose pipe (as per IS : 636) Type-A of 63 mm dia and length as described below. The hose shall be rated for burst pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound & riveted to hose pipe with aluminium rivets & 1.5 mm GI wire complete all as specified and directed.
Supply and Fixing 63 mm dia instantaneous pattern SS (Stainless Steel) Short branch pipe, 15 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete all as specified and directed.
Supply and fixing in repair of swinging type First Aid hose reel in red colour drum with 30 mts long and 20 mm dia heavy duty rubber water hose, 20 mm dia gate gun metal valve stop cock, (IS:778, class - II) terminating with SS coupling & nozzle of 6 mm outlet with shut off valve confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastener, bolts & nuts.
S&F in replacement old unserviceable of Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed.
S&F in repair of Pressure gauge 4"dial 0-14 kgs rating complete all as specified and directed.
S&F in repair of Pressure switch Universal type complete all as specified and directed.
S&F in repair of Addressable manual call point resettable type complete all as specified and directed.
M&L for Servicing to monoblock motor and pump set 7.5 HP with greasing and replacement of electrical terminal including painting all as directed.
-BLANK-
S&F in repair twisted 2 run of 1.5 sqmm shielded PVC insulated FPLR cable ISI Marked unsheathed cable copper conductor complete all as specified and directed.
S&F in repair rigid steel conduit, welded of 20mm diameter concealed/Surface in wall/Ceiling/above false ceiling and all fixing accessories/ materials complete all as specified and directed.
S&F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Supply and fixing of signage shop glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12" x 6" X 8 mm decorative transparent acrylic, including fixing arrangement all as specified and directed.
Supply and fixing fire extinguisher CO2 type (light IS:15683 weight squeeze grip type) 3 Kg Capacity
Supply and fixing fire extinguisher Dry Chemical/Dry Powder (IS:15683 Powder ABC type) 6 Kg Capacity
Supply and fixing Mechanical foam extinguisher (IS:15683 Stored pressure type) 9 ltrs Capacity
Supply, Installation, testing and Commissioning including taking down old panel of 4 loop Addressable fire alarm panel Epoxy powder coated, with loop capacity of 126 devices per loop, IP30 protection, 14 zonal LED indicators, 2 programmable sounder circuit, large graphic display, sensitive adjustment and drift compensation, variable language and character settings and supports Apollo protocols complete all as specified and directed. The panel should have an integral 240 X 64 pixel graphic LCD and built-in 220 VAC power supply with battery charger capable of charging 02 nos X 07 Ah 12 VDC batteries. The panel should support both 'A' class and 'B' class wiring with user friendly interface and should have 05 nos digital inputs for silence, reset, fault etc and daily/weekly/monthly/yearly backup facility. The panel should also have provision for graphic software with TCP/IP and provision for BMS integration over MODBUS protocol. The panel should be EN-54/LPCB/UL/VDS approved. The panel should clearly indicate the following indications: o POWER ON green LED indicator o FIRE ALARM red LED indicator o PRE-ALARM yellow LED indicator o ON TEST yellow LED indicator o BUZZER SILENCED yellow LED indicator o DELAY ACTIVE yellow LED indicator o MORE EVENTS yellow LED indicator o GENERAL DISABLEMENT yellow LED indicator o GENERAL FAULT yellow LED indicator o POWER FAULT yellow LED indicator o SYSTEM FAULT yellow LED indicator
M&L for painting of LT Panel Indoor/Outdoor type area of front face of panel exc 1.5 Sqm but n.exc 2.2 Sqm each with spray gun with two coats of synthetic enamel heat resistant grey paint including preparation of old painted surfaces/removing old faded/rust/ cemented material of surface of complete LT panel, complete all as specified and directed.
S&F in repair old unserviceable angle iron work and fixing/ fabrication of angle iron frame 40x40x5mm thick for LT Panel complete including welding work at site complete all as specified and directed.
S&F in repair LT panel of any size/make incl cutting, welding of front panel, back cover and top cover made of CRCA steel sheet of size not less than 3.15mm thick including colour, matching with existing including hinges and locking devices complete all as specified and directed.
S&F in repair of aluminium bus bar PVC insulated in RED, yellow, Blue & Black colours of rating 400 Amps complete all as specified and directed.
S&F in repair of aluminium bus bar PVC insulated in RED, yellow, Blue & Black colours of rating 800 Amps complete all as specified and directed.
S&F in repair of aluminium bus bar PVC insulated in RED, yellow, Blue & Black colours of rating 1500 Amps complete all as specified and directed.
S&F in repair of insulator of appropriate size with existing one complete all as specified and directed.
M&L taking down shutdown the LT panel and disconnecting the power cable for necessary repair and servicing of ACB 1000 Amps to 2000 Amps including testing complete all as specified and directed.
S&F in repair of 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
S&F in repair of 3 Pole MCCB, 125 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
S&F in repair of 3 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in repair of 3 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in repair of 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in repair of 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 25KA complete all as specified and directed.
Supply, laying connecting and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core including taking disconnecting & taking down old unserviceable cables complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core including taking disconnecting & taking down old unserviceable cables complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 core including taking disconnecting & taking down old unserviceable cables complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core including taking disconnecting & taking down old unserviceable cables complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) for repairing of LT pole foundation etc including filling in road cuts/hard standing etc complete all as specified and directed.
S&F in repair of APFC relay for 10 KVAR, 10 Stages complete all as specified and directed.
S&F in repair of LED type Indicating lamp type of voltage AC/DC set of RYB, as per matching to existing complete all as specified and directed.
S&F in repair of capacitor Bank MPP-H, 05 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, round type complete all as specified and directed.
S&F in repair of Capacitor Bank MPP-H, 10 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, round type complete all as specified and directed.
S&F in repair of capacitor duty, contactor MO C5 complete all as specified and directed.
S&F in repair of capacitor duty, contactor MO C 12.5 complete all as specified and directed.
S&F in repair of capacitor duty, contactor MO C 25 complete all as specified and directed.
S&F in repair of capacitor duty, contactor MO C 50 complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 Sqmm 3.5 core including taking down old unserviceable complete all as specified and directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed
M&L for sub class 'B' burnt brick flat across the cable, for protection of cable laid in trenches complete all as specified and directed
M&L for taking out and relaying of serviceable sub class 'B' burnt brick flat across the cable, for protection of cable laid in trenches complete all as specified and directed
Supply and laying in repair GI pipe light grade of 150mm dia laid in trenches for protection of UG cable complete all as specified and directed.
Supply and laying in repair GI pipe light grade of 100mm dia laid in trenches for protection of UG cable complete all as specified and directed
Supply and laying in repair GI pipe light grade of 50mm dia laid in trenches for protection of UG cable complete all as specified and directed.
S&F in repair of ARD Battery for lifts 12 Volts 7 AH all complete all as specified and directed.
S&F in repair of lift cabin light fittings as per existing fittings complete all as specified and directed.
S&F in repair of SWR Rope 13 MM dia & Existing length for lifts complete all as specified and directed.
S&F in repair of lift cabin fan as per OEM specification as per the existing fitting complete all as specified and as directed
S&F in repair of lift door sensor as per OEM specification and existing model complete all as specified and as directed
S&F in repair control wiring for lift panel with 2.5 sqmm multistranded FRLSH copper cable for the lift of existing make complete all as specified and as directed.
S&F in repair of push button with indicator as per sample and as per OEM OEM specification complete all as specified and as directed
dee een enterprises
Pradeep Bros
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .